Instrumentation and Solutions
India
Registrace 12. 11. 2016
Instrumentation and Control
Video
Solenoid valve (different types)
zhlédnutí 1,9KPřed rokem
Different types of solenoid Valves and it's applications
Fisher DVC 6000 Positioner Internal Parts
zhlédnutí 2KPřed rokem
Fisher DVC 6000 Positioner Internal Parts
Fisher DVC-6200 manual calibration
zhlédnutí 9KPřed 2 lety
Manual calibration, Analog calibration, Digital Calibration
Operating Control valve with SOV
zhlédnutí 631Před 2 lety
Operating Control valve with external PID controller, 5/2 SOV, and LVDT.....
Temperature controller (Omron -E5CC)
zhlédnutí 16KPřed 2 lety
basic parameters configuration, controller checking .
Metso ND-9000 Positioner basic settings
zhlédnutí 10KPřed 2 lety
Metso ND-9000 positioner basic settings
Troubleshooting of Metso Positioner, ND-9000 series
zhlédnutí 6KPřed 2 lety
Spool Jammed error, Removing spool block, checking and cleaning.
Concept of Digital Inputs Contacts (NO-NC)
zhlédnutí 477Před 3 lety
Concept of Digital Inputs Contacts (NO-NC)
Temperature Transmitter Compensation CJC, Cold junction compensation of thermocouple
zhlédnutí 6KPřed 5 lety
Temperature Transmitter Compensation CJC, Cold junction compensation of thermocouple
Metso's Neles ND9000 Smart Positioner Calibration
zhlédnutí 24KPřed 7 lety
Metso's Neles ND9000 Smart Positioner Calibration
Siemens PS2 Smart Positioner used as Remote Positioner
zhlédnutí 5KPřed 7 lety
Siemens PS2 Smart Positioner used as Remote Positioner
How to reverse the feedback of dvc 6200 positionet
Sorry, I never done ... and right now, I didn't have that positioner to check ..
How reverse the feedback of 6200 positionet
Acha hei…
Electro pneumatic volve video pl upload sir
Useful video
Useful video
Thanks bro, your videos helped us
Good
Dear how i can adjust fork lever bcz when i calibrated it error came 0002
Best practices are to give external air supply to actuator and open 50% and at that time, the positioner feedback link should be (horizontal -----------------)
Spool block se continue air passing ho raha hai wo kaise thik karege please btaye
If double acting actuator then check actuator passing and remove spool clean it and refix it....check the gasket once
Auto calibration option is not showing after going CAL option what is problem
If there is any error, you need to rectify that 1st ...
Facing an issue not powering up even after connecting power
Check the polarity once and remove one wire and check voltage in series, then you will know any problem with PCB ....
Looks like a very informative video. Too bad I don’t understand the language. Do you want to make the same video in English?
I will try ...thq u
Adjustment kaise karte hai.Agar scale me error aata hai to. Q k pneumatic me error aata hai to zero or span se adjust kar lete hain. Smart me kaise karte hain. Please reply.
Only you can adjust realy in 6200, other smart positioner having different options for little adjustments...ABB I/P can be adjusted... need to go through those instruments..
SOV & Volume booster ke work me kya difference hai.
Both are totally different 1. Volume booster used for large actuator for quick response or speed operation. (can be used in the control valve as well as in on/off valves ) 2. SOV are used for operating on/off valves and in some applications used to block the path (safety interlock)
BAHUT ASSA GURU JI
Thq you
Positioner is not taking Setpoint/ demand from remote DCS... Able to operate locally... What can be the issue
Keep positioner operating mode to 1.1 .. Check the feedback cable and current mA cable once ... Sometimes cable can be interchanged ...
@@instrumentationandsolution5013 checked in 1.1 it's working fine and also able to operate in local mode. Only in remote mode it's not operating. ps. it's a profibus PA device
Check the address in the positioner ..
What is sigma 1 & sigma 2? Is it like different totalizer readings? Is it same like trip A & trip B in cars?
I never used and zero sigma values are used for uneven/bad installation, vibration, air/gas bubbles in flow tube...
क्या कोई बता सकता है, दिल्ली की हवा में कितने प्रतिशत आक्सिजन है ?
Multi gas analyzer lagana hai Bhai ... Wo bohut costly hai... Pollution is going to increase everywhere 😔😔😔😔....
Output bias means???
Positioner output is not accurate as per a given signal ... So the controller checks given signal vs output or outcome of the signal ...
Trex communicator se lowercase letter kaise type karna hota hai specially unit change karne ke liye please btaye
The unit can be changed in basic setup or detailed setup,
sir i ues auto adjust and run 20 outlet no have any air come out how to do ?? can repair or no??
May I/P having issues... Check and Calibrate I/P... U can check my I/P checking and calibration Video once ...
@@instrumentationandsolution5013 I try use reset, still can not use . Always run 20 outlet no have any air come out
sir i ues auto adjust and run 20 outlet no have any air come out how to do ?? can repair or no??
U can adjust I/P... Plz check my I/P adjustment video...
Sir, The meter keeps running when the pump is in off position can you please solve this
If the flow tube is empty then sometimes the flow transmitter shows values.. earthing.. and external induction... Or flow converter/ transmitter having issue
Thank you sir for your valuable information 👍👍👍👍👍❤️❤️❤️
S N kaise change hoga?
What do you mean by S N..?
Serial Number kaise Change hoga pls sir
Very Good Video.
Sir your video is jabardast hai
Hello dear friend there is one resion in abb positinor that when we give comand 0 to 100 then going 0 to 50 direct
Not going 25 percentage going 0 to 50 ,75,100. And 100 to 75,50 ,and when giving 25 not going 50 to direct come 0
Check Parameter -3.0 minimum range should be zero% and maximum should be 100%, and what is the parameter selection of 2.0 and 2.2 ... If possible update me 2.0, 2.2 and 3.0 parameter...
Can I simulate 0 to 100% traveling by using TREX. Because before I already try. The % value we can send,but valve haven't move. Similar another positioner value we can send by using TREX, or another option in that positioner. So Pls clarify this.
U can do a manual stroke check with the local buttons ... It's very easy... Through hart also u can simulation.. if the positioner has any issue then it will not operate ...
Isko zero kaise kare
Check the zero trimming option, before doing zero ensure the outlet valve should close properly and the flow tube should be filled with process fluid...
Thanks, pls explain dead angle linearization, and one point calibration, Also service of ND3000 series spool assembly
If Spool is having issues, u will get an error then you can clean the spool, dead angle linearization never done .. need to check once ..
Sir Mera abb ka positioner me output feedback nhi aa raha hai
AO feedback?
What we can do if position is already out of range
Out of range means ? .. positioner pot having issues or positioner mounting issue... Need to find out the exact issue..
Can you help me ?
What is the problem..
Working manual but not working with 4-20ma.
plz show the connection of the wire. we need urgent . can we replace this by the simple directional valve
U can't replace it with normal DCV ...I left that company, unable to show you wiring connection,
Nice video sir ji....isi tarah aur bhi video banaye...
Suppose valve is closed and positioner displays 100% then what we can do to display 0%
While installing a new positioner or maintenance problem or you want to change it
Thanks u sir
Sir aap density transmitter par video banaye na please
Auto calibration jab krte hai tb 20% tak jata hai ...uske bad spane error likha hua ata hai screen par.....spane error ku ata hai.....plz help
Check angle once.. at 50% valve opening angle should be 0.... so u can adjust feedback angle with POT. Then again go for auto cal
Service password
Four zeros... 0000.. normal password for quick setup ...
Bhai ise stroke chek kaise karenge by trex
Hart type
I never did with hart ... If it's communicating then u can start the simulation with changing DIP switch position according to positioner model ...
How to check the servo valve mechanically
You need to check in the field..remove installed one and fix the repair one .. this is general practice.. some companies can provide a test bench for troubleshooting ...
Pulse kasise chenge karega
I never did that .. but exactly what you want to do ...
কোন পাল্স এর কথা বলছেন
स्मार्ट पोजीशनर है जो ऑटो में सही काम कर रहा है पर मैनुअल में डालते ही या तो ओपन या क्लोज हो जाता है ,कैसे सॉल्व करे कुछ सेटिंग में हो
You need to do the I/P adjustment.. check my I/P adjustment video.
@@instrumentationandsolution5013 कोई प्रोग्राम में दिक्कत तो नही है ना
I/p कही खराब ना हो जाए
@@sanojkumar-ty3rf may be .. but in manual mode if it is opening or closing them hunting will be there while operating, so in parameters 7 u can increase dead band..
Dear sir, you not clear, what is the value set at decode board. Can I used veritable resistor alternat decode board
PT1000 RTD used for cold junction compensation, u need to put atmospheric temperature ( the resistance value around 1110 to 1120 ohms)
We are facing issue in positioners,that after calibration it gets automatically forgets its position after 3-4hours..then we need to recalibrate again
Did you checked feedback adapter tightness and POT resistance, issue may in feedback part....check properly once again ...
Please help me sir
How can I help you...
Super sir
Amazing sir
Sir any video on samson positioner repair