Instrumentation and Solutions
Instrumentation and Solutions
  • 29
  • 222 777
Neles Positioner
Positioner internal parts
zhlédnutí: 1 825

Video

Electric Actuator, NIBSCO- NA1200XTNA
zhlédnutí 344Před rokem
Electric actuator basic parameters
Krohne magnetic flow convertor
zhlédnutí 4,7KPřed rokem
basic parameters
Solenoid valve (different types)
zhlédnutí 1,9KPřed rokem
Different types of solenoid Valves and it's applications
Rexroth Proportional valve (3DREPE)
zhlédnutí 2,4KPřed rokem
Valve electronic card function checking
Fisher DVC 6000 Positioner Internal Parts
zhlédnutí 2KPřed rokem
Fisher DVC 6000 Positioner Internal Parts
Fisher DVC-6200 manual calibration
zhlédnutí 9KPřed 2 lety
Manual calibration, Analog calibration, Digital Calibration
Siemens Positioner PS2 Internal parts
zhlédnutí 5KPřed 2 lety
positioner Internal parts ..
Operating Control valve with SOV
zhlédnutí 631Před 2 lety
Operating Control valve with external PID controller, 5/2 SOV, and LVDT.....
Fisher DVC6200
zhlédnutí 5KPřed 2 lety
Auto calibration and some basic information...
PNP and NPN sensors
zhlédnutí 287Před 2 lety
basic difference between NPN and PNP sensors ......
Temperature controller (Omron -E5CC)
zhlédnutí 16KPřed 2 lety
basic parameters configuration, controller checking .
Metso ND-9000 Positioner basic settings
zhlédnutí 10KPřed 2 lety
Metso ND-9000 positioner basic settings
Troubleshooting of Metso Positioner, ND-9000 series
zhlédnutí 6KPřed 2 lety
Spool Jammed error, Removing spool block, checking and cleaning.
Magnetic flow tube
zhlédnutí 616Před 3 lety
Troubleshooting of mag flow tube.
ABB TZIDC Positioner I/P adjustment
zhlédnutí 2KPřed 3 lety
ABB TZIDC Positioner I/P adjustment
ABB TZIDC Positioner Troubleshooting
zhlédnutí 8KPřed 3 lety
ABB TZIDC Positioner Troubleshooting
ABB TZIDC Calibration
zhlédnutí 10KPřed 3 lety
ABB TZIDC Calibration
Concept of Digital Inputs Contacts (NO-NC)
zhlédnutí 477Před 3 lety
Concept of Digital Inputs Contacts (NO-NC)
Making of mA Source - 4 to 20mA
zhlédnutí 1,4KPřed 5 lety
Making of mA Source - 4 to 20mA
Temperature Transmitter Compensation CJC, Cold junction compensation of thermocouple
zhlédnutí 6KPřed 5 lety
Temperature Transmitter Compensation CJC, Cold junction compensation of thermocouple
2wire vs 3wire RTD,
zhlédnutí 1,4KPřed 5 lety
2wire vs 3wire RTD,
Transmitter Calibration (D/A Trim)
zhlédnutí 25KPřed 6 lety
Transmitter Calibration (D/A Trim)
YOKOGAWA Oxygen Analyzer ZR402G
zhlédnutí 23KPřed 7 lety
YOKOGAWA Oxygen Analyzer ZR402G
Metso's Neles ND9000 Smart Positioner Calibration
zhlédnutí 24KPřed 7 lety
Metso's Neles ND9000 Smart Positioner Calibration
Fisher DVC 2000 Calibration
zhlédnutí 23KPřed 7 lety
Fisher DVC 2000 Calibration
Siemens smart positioner PS2
zhlédnutí 1,4KPřed 7 lety
Siemens smart positioner PS2
Siemens PS2 Smart Positioner used as Remote Positioner
zhlédnutí 5KPřed 7 lety
Siemens PS2 Smart Positioner used as Remote Positioner
SMC Smart Positioner Calibration
zhlédnutí 25KPřed 7 lety
SMC Smart Positioner Calibration

Komentáře

  • @SunilKumar-t6g
    @SunilKumar-t6g Před 9 dny

    How to reverse the feedback of dvc 6200 positionet

  • @SunilKumar-t6g
    @SunilKumar-t6g Před 9 dny

    How reverse the feedback of 6200 positionet

  • @2008sindus
    @2008sindus Před 29 dny

    Acha hei…

  • @saishiva8957
    @saishiva8957 Před měsícem

    Electro pneumatic volve video pl upload sir

  • @mohsinraza9944
    @mohsinraza9944 Před 2 měsíci

    Useful video

  • @mohsinraza9944
    @mohsinraza9944 Před 2 měsíci

    Useful video

  • @ARaghavaReddy-tw1tm
    @ARaghavaReddy-tw1tm Před 2 měsíci

    Thanks bro, your videos helped us

  • @mohsinraza9944
    @mohsinraza9944 Před 2 měsíci

    Good

  • @nanakdev6488
    @nanakdev6488 Před 2 měsíci

    Dear how i can adjust fork lever bcz when i calibrated it error came 0002

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 2 měsíci

      Best practices are to give external air supply to actuator and open 50% and at that time, the positioner feedback link should be (horizontal -----------------)

  • @maruttripathi3268
    @maruttripathi3268 Před 2 měsíci

    Spool block se continue air passing ho raha hai wo kaise thik karege please btaye

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 2 měsíci

      If double acting actuator then check actuator passing and remove spool clean it and refix it....check the gasket once

  • @bhaveshpanchal6619
    @bhaveshpanchal6619 Před 2 měsíci

    Auto calibration option is not showing after going CAL option what is problem

  • @majidismaeil2785
    @majidismaeil2785 Před 2 měsíci

    Facing an issue not powering up even after connecting power

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 2 měsíci

      Check the polarity once and remove one wire and check voltage in series, then you will know any problem with PCB ....

  • @alejandrocervantes4981
    @alejandrocervantes4981 Před 2 měsíci

    Looks like a very informative video. Too bad I don’t understand the language. Do you want to make the same video in English?

  • @saquibkhan1230
    @saquibkhan1230 Před 2 měsíci

    Adjustment kaise karte hai.Agar scale me error aata hai to. Q k pneumatic me error aata hai to zero or span se adjust kar lete hain. Smart me kaise karte hain. Please reply.

    • @AnilKumar-xo7ot
      @AnilKumar-xo7ot Před 2 měsíci

      Only you can adjust realy in 6200, other smart positioner having different options for little adjustments...ABB I/P can be adjusted... need to go through those instruments..

  • @saquibkhan1230
    @saquibkhan1230 Před 2 měsíci

    SOV & Volume booster ke work me kya difference hai.

    • @AnilKumar-xo7ot
      @AnilKumar-xo7ot Před 2 měsíci

      Both are totally different 1. Volume booster used for large actuator for quick response or speed operation. (can be used in the control valve as well as in on/off valves ) 2. SOV are used for operating on/off valves and in some applications used to block the path (safety interlock)

  • @worldinstrumentationengineer

    BAHUT ASSA GURU JI

  • @udayachaithanyanath
    @udayachaithanyanath Před 4 měsíci

    Positioner is not taking Setpoint/ demand from remote DCS... Able to operate locally... What can be the issue

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 4 měsíci

      Keep positioner operating mode to 1.1 .. Check the feedback cable and current mA cable once ... Sometimes cable can be interchanged ...

    • @udayachaithanyanath
      @udayachaithanyanath Před 4 měsíci

      @@instrumentationandsolution5013 checked in 1.1 it's working fine and also able to operate in local mode. Only in remote mode it's not operating. ps. it's a profibus PA device

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 4 měsíci

      Check the address in the positioner ..

  • @feyziwithnosurname7011
    @feyziwithnosurname7011 Před 5 měsíci

    What is sigma 1 & sigma 2? Is it like different totalizer readings? Is it same like trip A & trip B in cars?

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 4 měsíci

      I never used and zero sigma values are used for uneven/bad installation, vibration, air/gas bubbles in flow tube...

  • @user-po9dn3ot5c
    @user-po9dn3ot5c Před 5 měsíci

    क्या कोई बता सकता है, दिल्ली की हवा में कितने प्रतिशत आक्सिजन है ?

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 5 měsíci

      Multi gas analyzer lagana hai Bhai ... Wo bohut costly hai... Pollution is going to increase everywhere 😔😔😔😔....

  • @patelravi131
    @patelravi131 Před 5 měsíci

    Output bias means???

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 5 měsíci

      Positioner output is not accurate as per a given signal ... So the controller checks given signal vs output or outcome of the signal ...

  • @maruttripathi3268
    @maruttripathi3268 Před 5 měsíci

    Trex communicator se lowercase letter kaise type karna hota hai specially unit change karne ke liye please btaye

  • @HaungAdam
    @HaungAdam Před 5 měsíci

    sir i ues auto adjust and run 20 outlet no have any air come out how to do ?? can repair or no??

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 5 měsíci

      May I/P having issues... Check and Calibrate I/P... U can check my I/P checking and calibration Video once ...

    • @HaungAdam
      @HaungAdam Před 5 měsíci

      @@instrumentationandsolution5013 I try use reset, still can not use . Always run 20 outlet no have any air come out

  • @HaungAdam
    @HaungAdam Před 5 měsíci

    sir i ues auto adjust and run 20 outlet no have any air come out how to do ?? can repair or no??

  • @ilanila2022
    @ilanila2022 Před 6 měsíci

    Sir, The meter keeps running when the pump is in off position can you please solve this

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 5 měsíci

      If the flow tube is empty then sometimes the flow transmitter shows values.. earthing.. and external induction... Or flow converter/ transmitter having issue

    • @ilanila2022
      @ilanila2022 Před 5 měsíci

      Thank you sir for your valuable information 👍👍👍👍👍❤️❤️❤️

  • @AnilKumar-vf1ym
    @AnilKumar-vf1ym Před 6 měsíci

    S N kaise change hoga?

  • @vinaysane5435
    @vinaysane5435 Před 6 měsíci

    Very Good Video.

  • @zahidahmad7028
    @zahidahmad7028 Před 7 měsíci

    Sir your video is jabardast hai

  • @zahidahmad7028
    @zahidahmad7028 Před 7 měsíci

    Hello dear friend there is one resion in abb positinor that when we give comand 0 to 100 then going 0 to 50 direct

    • @zahidahmad7028
      @zahidahmad7028 Před 7 měsíci

      Not going 25 percentage going 0 to 50 ,75,100. And 100 to 75,50 ,and when giving 25 not going 50 to direct come 0

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 7 měsíci

      Check Parameter -3.0 minimum range should be zero% and maximum should be 100%, and what is the parameter selection of 2.0 and 2.2 ... If possible update me 2.0, 2.2 and 3.0 parameter...

  • @harikrishnan2223
    @harikrishnan2223 Před 7 měsíci

    Can I simulate 0 to 100% traveling by using TREX. Because before I already try. The % value we can send,but valve haven't move. Similar another positioner value we can send by using TREX, or another option in that positioner. So Pls clarify this.

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 7 měsíci

      U can do a manual stroke check with the local buttons ... It's very easy... Through hart also u can simulation.. if the positioner has any issue then it will not operate ...

  • @ambikeshgiri2284
    @ambikeshgiri2284 Před 8 měsíci

    Isko zero kaise kare

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 7 měsíci

      Check the zero trimming option, before doing zero ensure the outlet valve should close properly and the flow tube should be filled with process fluid...

  • @maqboolvahora9925
    @maqboolvahora9925 Před 8 měsíci

    Thanks, pls explain dead angle linearization, and one point calibration, Also service of ND3000 series spool assembly

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 7 měsíci

      If Spool is having issues, u will get an error then you can clean the spool, dead angle linearization never done .. need to check once ..

  • @shaikhusman5987
    @shaikhusman5987 Před 8 měsíci

    Sir Mera abb ka positioner me output feedback nhi aa raha hai

  • @user-ho3ru6uo4t
    @user-ho3ru6uo4t Před 9 měsíci

    What we can do if position is already out of range

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 7 měsíci

      Out of range means ? .. positioner pot having issues or positioner mounting issue... Need to find out the exact issue..

  • @user-wr4un7wq9b
    @user-wr4un7wq9b Před 9 měsíci

    Can you help me ?

  • @nirajkumar2388
    @nirajkumar2388 Před 9 měsíci

    plz show the connection of the wire. we need urgent . can we replace this by the simple directional valve

  • @Sultankhan-pk1qh
    @Sultankhan-pk1qh Před 10 měsíci

    Nice video sir ji....isi tarah aur bhi video banaye...

  • @sushantgaikwad8973
    @sushantgaikwad8973 Před 10 měsíci

    Suppose valve is closed and positioner displays 100% then what we can do to display 0%

  • @Rohit-zc2ew
    @Rohit-zc2ew Před 10 měsíci

    Thanks u sir

    • @Rohit-zc2ew
      @Rohit-zc2ew Před 6 měsíci

      Sir aap density transmitter par video banaye na please

  • @29Avik.bishnoi
    @29Avik.bishnoi Před 10 měsíci

    Auto calibration jab krte hai tb 20% tak jata hai ...uske bad spane error likha hua ata hai screen par.....spane error ku ata hai.....plz help

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 10 měsíci

      Check angle once.. at 50% valve opening angle should be 0.... so u can adjust feedback angle with POT. Then again go for auto cal

  • @devarajann5368
    @devarajann5368 Před 11 měsíci

    Service password

  • @NagendraVlogs7485
    @NagendraVlogs7485 Před 11 měsíci

    Bhai ise stroke chek kaise karenge by trex

  • @17_sarkar
    @17_sarkar Před 11 měsíci

    How to check the servo valve mechanically

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před 11 měsíci

      You need to check in the field..remove installed one and fix the repair one .. this is general practice.. some companies can provide a test bench for troubleshooting ...

  • @sumeshkm98
    @sumeshkm98 Před rokem

    Pulse kasise chenge karega

  • @sanojkumar-ty3rf
    @sanojkumar-ty3rf Před rokem

    स्मार्ट पोजीशनर है जो ऑटो में सही काम कर रहा है पर मैनुअल में डालते ही या तो ओपन या क्लोज हो जाता है ,कैसे सॉल्व करे कुछ सेटिंग में हो

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před rokem

      You need to do the I/P adjustment.. check my I/P adjustment video.

    • @sanojkumar-ty3rf
      @sanojkumar-ty3rf Před rokem

      @@instrumentationandsolution5013 कोई प्रोग्राम में दिक्कत तो नही है ना

    • @sanojkumar-ty3rf
      @sanojkumar-ty3rf Před rokem

      I/p कही खराब ना हो जाए

    • @AnilKumar-xo7ot
      @AnilKumar-xo7ot Před rokem

      @@sanojkumar-ty3rf may be .. but in manual mode if it is opening or closing them hunting will be there while operating, so in parameters 7 u can increase dead band..

  • @razzaqulhaider440
    @razzaqulhaider440 Před rokem

    Dear sir, you not clear, what is the value set at decode board. Can I used veritable resistor alternat decode board

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před rokem

      PT1000 RTD used for cold junction compensation, u need to put atmospheric temperature ( the resistance value around 1110 to 1120 ohms)

  • @industrial-techno8984

    We are facing issue in positioners,that after calibration it gets automatically forgets its position after 3-4hours..then we need to recalibrate again

    • @instrumentationandsolution5013
      @instrumentationandsolution5013 Před rokem

      Did you checked feedback adapter tightness and POT resistance, issue may in feedback part....check properly once again ...

  • @SonuKumar-gb8yz
    @SonuKumar-gb8yz Před rokem

    Please help me sir

  • @reshmisivagayathri3472

    Super sir

  • @reshmisivagayathri3472

    Amazing sir

  • @instrumentation4u531

    Sir any video on samson positioner repair