    One Control Valve hunting Example if open 75 % then we find CV hunting as like 74.90 to 74.25 then how to trouble shoot..
    Plz explain.....

    • @instrumentationandsolution5013
      @instrumentationandsolution5013  Před rokem

      1. Check any air leakage near fittings
      2. Check valve actuator passing
      If above both are ok then
      3. Put CV in manual mode then oper around 50 or 60%, then check position of valve if slowly closing or opening then u need to adjust I/P accordingly..

    • @UmeshSingh-rg1qs
      @UmeshSingh-rg1qs Před rokem

      @@instrumentationandsolution5013 @ Thanks a lot Sir.....

  • @cv8035
    @cv8035 Před 3 lety

    Next video sir

  • @HaungAdam
    @HaungAdam Před 6 měsíci +1

    sir i ues auto adjust and run 20 outlet no have any air come out how to do ?? can repair or no??

    • @instrumentationandsolution5013
      @instrumentationandsolution5013  Před 6 měsíci

      May I/P having issues... Check and Calibrate I/P... U can check my I/P checking and calibration Video once ...

    • @HaungAdam
      @HaungAdam Před 6 měsíci

      @@instrumentationandsolution5013 I try use reset, still can not use . Always run 20 outlet no have any air come out

  • @shaikhusman5987
    @shaikhusman5987 Před 9 měsíci +1

    Sir Mera abb ka positioner me output feedback nhi aa raha hai

  • @29Avik.bishnoi
    @29Avik.bishnoi Před 11 měsíci +1

    Auto calibration jab krte hai tb 20% tak jata hai ...uske bad spane error likha hua ata hai screen par.....spane error ku ata hai.....plz help

    • @instrumentationandsolution5013
      @instrumentationandsolution5013  Před 11 měsíci

      Check angle once.. at 50% valve opening angle should be 0.... so u can adjust feedback angle with POT. Then again go for auto cal

  • @surajgharge5737
    @surajgharge5737 Před 3 lety

    Sir for 4 mA i need cylinder close and for 20 mA full open
    Which port (out 1 or out 2) connected to front side of cylinder

    • @instrumentationandsolution5013
      @instrumentationandsolution5013  Před 3 lety

      Hii, just give 4mA to positioner and check from which port pneumatic output coming, connect that port with close port of the actuator. It depends on valve opening, some valves open in clockwise and some counter clockwise, so u can connect accordingly, note - u have to select parameters according to valve opening and actuator in positioner to avoid unwanted problems.