Before and after cleaning the filter and how much it effects how hard/fast the inverter compressor runs. The easy way to check this is by using a clamp amp meter and looking at the current draw of the system, then look at the rated current draw on the name plate/brochure.
zhlédnutí: 120

Video

Shitbox rally prep, will the $1 Pulsar make it ?
zhlédnutí 210Před měsícem
Getting the Pulsar ready for its 4500Km outback adventure, we paint the car, get it sign written, go over it mechanically, install a UHF Radio, stereo, driving lights, backup battery, loud speaker and police sirens.
How To Set LG Deluxe schedule timer
zhlédnutí 101Před 2 měsíci
With so many different air conditioner brands on the market and each having their own different spin on timers, it's difficult to get your head around them, especially once you have mastered your old A/C controller. And then you get a new A/C with a different controller. In this video, I go through how to setup the timer on an LG Deluxe Wired Wall Controller, which is necessary when you live in...
Yep, in 2024 we’re doing the Shitbox Rally to raise money for the Cancer Council 
zhlédnutí 246Před 7 měsíci
This winter we will be taking part in the Shitbox Rally, driving a shitbox (old car) through some of the roughest terrain in outback Australia. The rally starts in Melbourne and we will then zig zag our way through four different States and Territories, finishing in Alice Springs and racking up over 3,000km. This is all to raise money for the Cancer Council and we don’t think there’s anyone out...
30 November 2023
zhlédnutí 140Před 8 měsíci
30 November 2023
H9 fault on a Daikin split system, outdoor air thermistor fault
zhlédnutí 3,3KPřed rokem
Daikin H9 fault, faulty $15.00 sensor, but another repair company said “the inverter pc board is faulty and not worth repairing” tried to sell them a new 3.5K-4K system 😳
5 top tips to stop your air conditioner smelling
zhlédnutí 106KPřed rokem
I have put together my 5 top tips to help you keep your air conditioning from smelling. its based on the wall mounted split type air conditioning system but this can be applied to many types of air conditioning systems
How to clean your filter on your split system
zhlédnutí 69KPřed rokem
How to clean your filter on your split system
How to fault find a Daikin air conditioner, troubleshoot split system ductless, green light flashing
zhlédnutí 85KPřed 2 lety
How to fault find a Daikin air conditioner, troubleshoot split system ductless, green light flashing
Daikin zone controller set up BRC24Z4, BRC24Z8, BRC230Z4 and BRC230Z8.
zhlédnutí 34KPřed 2 lety
Daikin zone controller set up BRC24Z4, BRC24Z8, BRC230Z4 and BRC230Z8.
Daikin VRV IV-S commission procedures
zhlédnutí 17KPřed 2 lety
Daikin VRV IV-S commission procedures
Services call out to Daikin not working, C4 fault how to check with old controller
zhlédnutí 20KPřed 2 lety
Services call out to Daikin not working, C4 fault how to check with old controller
Daikin ducted not heating, no fault code ??
zhlédnutí 21KPřed 2 lety
Daikin ducted not heating, no fault code ??
Daikin VRV bulkhead units, G building project Yass, Designer home Air conditioning solution
zhlédnutí 2,1KPřed 3 lety
Daikin VRV bulkhead units, G building project Yass, Designer home Air conditioning solution
Defrost on a Daikin, what happens and why ??
zhlédnutí 14KPřed 3 lety
Defrost on a Daikin, what happens and why ??
Has Daikin stuffed up ?? US7 (Urura Sarah) what makes it so good
zhlédnutí 8KPřed 3 lety
Has Daikin stuffed up ?? US7 (Urura Sarah) what makes it so good
Weekend Sunrise tips on looking after your split system, how to fix bad smells from your A/C
zhlédnutí 1,1KPřed 3 lety
Weekend Sunrise tips on looking after your split system, how to fix bad smells from your A/C
How to strip down/clean your Daikin air conditioning indoor unit properly
zhlédnutí 288KPřed 3 lety
How to strip down/clean your Daikin air conditioning indoor unit properly
LG "PREMTA000" colour touchscreen controller, setting 7 day timer
zhlédnutí 2,9KPřed 4 lety
LG "PREMTA000" colour touchscreen controller, setting 7 day timer
Daikin BRC1E63 controller set up field settings cycle fan off, activate sensor in wall controller
zhlédnutí 179KPřed 4 lety
Daikin BRC1E63 controller set up field settings cycle fan off, activate sensor in wall controller
Roof space too small for air conditioning, we have the solution
zhlédnutí 11KPřed 4 lety
Roof space too small for air conditioning, we have the solution
built-in bulkhead system, air conditioning system, daikin FDX, salt filter change
zhlédnutí 46KPřed 4 lety
built-in bulkhead system, air conditioning system, daikin FDX, salt filter change
How to replace filter media to your ducted air conditioned or gas heater panel filter
zhlédnutí 32KPřed 4 lety
How to replace filter media to your ducted air conditioned or gas heater panel filter
No. 1 AC Fix! - How to properly clean AC filters, cleaning filter daikin ducted
zhlédnutí 68KPřed 4 lety
No. 1 AC Fix! - How to properly clean AC filters, cleaning filter daikin ducted
LG colour touchscreen controller set up PREMTB100
zhlédnutí 26KPřed 5 lety
LG colour touchscreen controller set up PREMTB100
Fully airconditioned
zhlédnutí 1,6KPřed 7 lety
Fully airconditioned
How to set timer & time on LG touchscreen controller PDRCUDC0
zhlédnutí 13KPřed 7 lety
How to set timer & time on LG touchscreen controller PDRCUDC0
How to fault find a Daikin Air Conditioner, troubleshoot split system, green flashing light.MOV
zhlédnutí 900KPřed 12 lety
How to fault find a Daikin Air Conditioner, troubleshoot split system, green flashing light.MOV

Komentáře

  • @jirist4196
    @jirist4196 Před 22 hodinami

    master piece AC

  • @madebyjovan
    @madebyjovan Před 2 dny

    Just cleaned my Mitsubishi AC this 3 weeks back and it started to have those foul smell. It's weird because it has never happen before :/ The pipe is connected to our bathroom where the water will drip and flow to our drainage (at a distance). Also question, for the Tea tree oil method, how often should we spray it?

    • @FullyAirconditioned
      @FullyAirconditioned Před 2 dny

      @@madebyjovan you can use the tea tree oil as often as needed, I would try disconnecting the drain from the point and see if it has any effect

    • @madebyjovan
      @madebyjovan Před 2 dny

      @@FullyAirconditioned would love to try disconnecting the drain but the pipe is covered with PVC case. Might need to call in the AC guy to do it 🥲 will give the tea tree oil method a try first. But how many drop should I drip into a cup of water to dilute it?

  • @potentialhvac6074
    @potentialhvac6074 Před 5 dny

    Fujitsu way easier to deal with

  • @jasonmcroberts7994
    @jasonmcroberts7994 Před 12 dny

    Can each individual room be temperature set differently? Just moved into a 6-7 year old house with this unit and we're struggling a bit with it. We're going to want 21-22 deg in a month or two whereas the kids won't need it as cold. It also doesn't seem to flow ANY air at all currently unless its set at 20 deg or under. A bit of research to be done clearly. Thanks

    • @FullyAirconditioned
      @FullyAirconditioned Před 12 dny

      @@jasonmcroberts7994 no it doesn’t control temp in different zones, it’s just on off zoning. Additional sensors can be fitted but that just changes the temp sensing location.

    • @jasonmcroberts7994
      @jasonmcroberts7994 Před 12 dny

      @@FullyAirconditioned thank you very much, appreciate the info so promptly. Cheers

  • @cristianmaier7886
    @cristianmaier7886 Před 14 dny

    Hello! Can you help me with field settings for a cassette type indoor unit, daikin fcag71aveb. I can't make the fan rotate with more than 590rpms. Thank you!

    • @FullyAirconditioned
      @FullyAirconditioned Před 14 dny

      @@cristianmaier7886 we don’t have that model here in Australia but the setting for out systems for high static fan is 23-6-02

    • @cristianmaier7886
      @cristianmaier7886 Před 14 dny

      @@FullyAirconditioned Thanks for the answer! 23-6- is - -, unavailable.

  • @LChristou-n4j
    @LChristou-n4j Před 14 dny

    Thank you very much for the detailed video. I don’t seem to have the Room Temp option in the Display Item options. Is there a setting to ensure this is available in Display Items? FYI, I have the BRC1E63 with FDYAN125AV1 Indoor unit and RZA125C2V1 Outdoor unit.

    • @FullyAirconditioned
      @FullyAirconditioned Před 14 dny

      @@LChristou-n4j it should be the same as what I have set, configuration, display, display item = room.

    • @LChristou-n4j
      @LChristou-n4j Před 14 dny

      @@FullyAirconditioned I only have three options, None, System and Outside Air Temperature. Any ideas why Room Temp is not an option; thought it might be a field settings issue but can’t find a master file that explains every field setting… Really appreciate your help.

    • @FullyAirconditioned
      @FullyAirconditioned Před 14 dny

      @@LChristou-n4j check felid setting 1c - 0 - 02 this allows room temp to be displayed in “detailed settings”. It’s set to this from factory so someone must have changed too 1c -0 - 01, “not displayed”.

    • @LChristou-n4j
      @LChristou-n4j Před 14 dny

      @@FullyAirconditionedThank you so much, that worked. Looks like my room temperature is not accurate - reporting 23 when it is closer to 19. I have implemented your other settings so it should be reading the wall unit temp. Any suggestions why this could be inaccurate and are there any fixes you’re aware of? Thanks so much again, really appreciate your time.

    • @FullyAirconditioned
      @FullyAirconditioned Před 14 dny

      @@LChristou-n4j there is no calibration for the sensor readings, if this sensor is active as the control it what controlling the system.

  • @CamBaniasadi
    @CamBaniasadi Před 15 dny

    Very helpful video. Is there a cheat sheet to summarise all those modes, switches and positions along with their descriptions?

    • @FullyAirconditioned
      @FullyAirconditioned Před 14 dny

      @@CamBaniasadi yes there is, it’s in the insulation manual, you should be able to search on line or the Daikin’s web site

    • @CamBaniasadi
      @CamBaniasadi Před 2 dny

      @@FullyAirconditioned Thanks heaps. And I assume that you consider the maximum airflow value not the nominal one, is that a correct assumption? I reckon for a 12.5kW Daikin system, the maximum airflow value is 840 while the nominal one is 755.

  • @Lore_tta
    @Lore_tta Před 18 dny

    Hello, could you please tell me if you know of course... The bottom Filter of the midea all easy pro, there are 3 different pieces of cleaning the air i think. The technicians didn't put them at installation, and i don't really know how to put them right. Also i can't find a distraction. Thanks a lot!!!

    • @FullyAirconditioned
      @FullyAirconditioned Před 18 dny

      @@Lore_tta sorry I am not familiar with that model, don’t believe it sold here in Australia. Have you tried the Midea website or contacting them directly?

  • @LaGerrand
    @LaGerrand Před 20 dny

    This helped me out immensely and saved us some $$. Thank you☺👍🏻

  • @tharimudiyanselage4018

    Imma save this video for future. Cheers mate, nicely done ❤

  • @MyBallzGotShocked
    @MyBallzGotShocked Před 21 dnem

    would be a shame if a single mouse found a way into that attic

  • @spooderman64
    @spooderman64 Před 23 dny

    You saved me approx $770 usd. I wasnt confident enough in taking the whole unit apart. Instead i used a hand pump water sprayer and an air compressor. Im totally satisfied.

  • @RomaaPlays
    @RomaaPlays Před 23 dny

    Have you looked into using Grapeseed oil as a non smelling alternative? or mixing the oil with a low concentrate of hydrogen peroxide and or baking soda?

    • @FullyAirconditioned
      @FullyAirconditioned Před 23 dny

      @@RomaaPlays no, if the smell keeps coming back we strip down the indoor unit and clean all components.

    • @RomaaPlays
      @RomaaPlays Před 23 dny

      @@FullyAirconditioned I have a unit that's only a few months old and I clean it constantly and it smells on fan mode sometimes still, even after I opened it and cleaned the internal components, I think it has to do with the fan wheel. I've sprayed it with different mold killers but smell always comes back... probably will disassemble and soak the fan in bleach 🤷

    • @FullyAirconditioned
      @FullyAirconditioned Před 23 dny

      @@RomaaPlays is the smell coming from the drain ?? On a split system a small amount of air gets drawn up the drain pipe, if some one has connect it to the sewer you could be getting smells from the drain.

    • @RomaaPlays
      @RomaaPlays Před 23 dny

      @@FullyAirconditioned it's a u shaped window ac from Midea, I clean the outside unit every couple weeks or so. I was also suspecting it since the drain is connected to the outdoor pan. some have advised to drill a drain hole but that would make it slightly less effective since the fan throws the pooled water

    • @FullyAirconditioned
      @FullyAirconditioned Před 23 dny

      @@RomaaPlays we don’t have those units in Australia, they don’t meet minimum energy efficiency standards. Basically all units in Australia have inverter compressors, you can get window units but they only very small capacity 2.0kw or 7000btu, any thing above this just doesn’t pass the standard. It’s a very small market for window units in Australia. Split type units with an inverter compressor is the most common and efficient.

  • @Zeviticus
    @Zeviticus Před 27 dny

    This has to be the most ridiculous way of finding a fault code. Who are the clowns who design this nonsense?

  • @HL-ng4bh
    @HL-ng4bh Před 29 dny

    Hi there! I'm using this controller in my duplex apartment. The vent in the upstairs living room is working just fine. However, the vent downstairs has its own wireless remote and receiver, but only the fan mode is working. When I try to switch it to cooling or heating, the receiver's light just blinks, and nothing happens. Any idea what's going on?

    • @FullyAirconditioned
      @FullyAirconditioned Před 29 dny

      @@HL-ng4bh it’s probably a VRV or multi head system with only one outdoor unit, change the mode at the upstairs unit to the mode you want down stairs. Then check the unit down stairs, it should go into the same mode. The up stairs unit is the master and dictates what mode the system is in, give it a try.

    • @HL-ng4bh
      @HL-ng4bh Před 17 dny

      @@FullyAirconditioned Thanks for the tip! I've made sure that both the upstairs and downstairs units are on the same mode, but the downstairs vent still isn’t working. Could this be something to do with the field settings? Looking forward to your further advice. Thanks!

  • @joel-pv1gr
    @joel-pv1gr Před 29 dny

    Hello, would you happen to know what a ua-02 error on a daikin ducted aircon is?

    • @FullyAirconditioned
      @FullyAirconditioned Před 29 dny

      @@joel-pv1gr Mismatching of indoor & outdoor Field setting of outdoor PCB not done after PCB replacement. Faulty indoor or outdoor PCB. Check F1/F2 transmission wiring. *For VRV excessive number of indoor units.

    • @joel-pv1gr
      @joel-pv1gr Před 29 dny

      @@FullyAirconditioned thank you, I appreciate your reply

  • @bradroesler7072
    @bradroesler7072 Před 29 dny

    Off topic, but why does Daikin do a preheat cycle on the startup sequence in heat mode?

    • @FullyAirconditioned
      @FullyAirconditioned Před 29 dny

      It does that so its not blowing cool air on start up, the coil heats up to a set temp, then the fan cycles on. As the coil maintains a rising temp the fan keeps stepping up in speed until it reaches its set speed.

  • @boomchancre
    @boomchancre Před měsícem

    Stuck in German in hotel… how do I change language settings plz

    • @FullyAirconditioned
      @FullyAirconditioned Před měsícem

      @@boomchancre push the middle buttons, that will take you into the menu, scroll all the way down to the bottom (this is language) push middle button again and it should have all the different languages 👍🏻😜

  • @alexandru7145
    @alexandru7145 Před měsícem

    👏👏👏👏👏👏👏👏👏👏

  • @vicenteherrera2751
    @vicenteherrera2751 Před měsícem

    Thank you sir

  • @che59v
    @che59v Před měsícem

    Looks like this equipment have to be avoided, way too Mach complexity.

  • @damprojectsolutions5777
    @damprojectsolutions5777 Před měsícem

    Awesome video, you are a legend. Short, sweet and straight to the point. Immense thanks.

  • @julianapatrick7451
    @julianapatrick7451 Před měsícem

    Oh you saved my life and I bless you SO much! Best advice ever!! Why didn't I think of that lol. I didn't know you could put oil in the mini split. Not just plain oil I know but it will wear off eventually and in the meantime it sticks to keep working! God's little cheap miracles! Thank you thank you thank you 🙏🙏❤

  • @FuelTim
    @FuelTim Před měsícem

    Huge help - thank you!

  • @isharathore9825
    @isharathore9825 Před měsícem

    Would you know why my thermostat keeps switching off after 3 hours (exactly 3). I have no timer on, nothing. Is there a field setting to disconnect the wall motion sensor?? I think my rented house might have a motion sensor that’s why it shuts off

    • @FullyAirconditioned
      @FullyAirconditioned Před měsícem

      @@isharathore9825 check the energy saving options, sounds like someone has set a push button time for 3 hours operation. Push menu, energy saving options, energy saving list and check that that they are all turned off, that should fix it.

  • @janetcarney953
    @janetcarney953 Před měsícem

    Hi, thank you for posting this clip, its been a life saver. I only have one question, my room temperature is 21, my set temperature is 20 which I increase to 27. It will run at that and warm the house for half hour or so, then stop and the set temperature is back to 20. How do I keep the 27 permanently displayed as the desired room temperature? Is there another mode number to set?

    • @FullyAirconditioned
      @FullyAirconditioned Před měsícem

      @@janetcarney953 you have set point auto reset active on your controller, go into menu, energy savings options, then go to energy saving list. Here it will let you know what energy saving are turned on, turn them all off.

  • @janetcarney953
    @janetcarney953 Před měsícem

    I cant find how to keep the set room temperarure on. It goes straight back to 20.. its winter and i set it to 28. How do I keep it on 28?

  • @timothybroga1704
    @timothybroga1704 Před měsícem

    Excellent video. I didn't notice if you did spray through and clean the coil maybe I missed it but anyways good content I install a lot of dakin units but I have never disassembled to this degree except for repair. Definitely Will do one in my house for practice

  • @GrimShizuri
    @GrimShizuri Před měsícem

    Letting the fan run did the trick for me. Thank you! EDIT: Never mind, the smell is back after 30 minutes.

  • @ferryboat866
    @ferryboat866 Před měsícem

    Can we turn it off for a specific room??

  • @alanv91
    @alanv91 Před měsícem

    Thank u so much my air was barely cooling and once i cleaned filter was like a brand new Ac !

  • @CKLee-rs4kl
    @CKLee-rs4kl Před měsícem

    Thank you so much! You just saved me $400.00 for the installer's electrician to come out and scratch his head and look at me like I'm simple minded. I put some potted boxwoods a foot in front of the fan and I'll try moving them to see if that solves the issue. I printed the codes -- which I couldn't find anywhere in the Daikin info I got after the install OR online. You're the best!

  • @godsbluehills
    @godsbluehills Před měsícem

    How would you go about cleaning a package system with tea tree oil?

    • @FullyAirconditioned
      @FullyAirconditioned Před měsícem

      @@godsbluehills a package unit as in a large roof mounted unit often used in commercial buildings?? you could do it just up scale to a pump up spray bottle and you would need to remove some panels to get to the coil.

  • @johnkoval8053
    @johnkoval8053 Před měsícem

    Ac shrine

  • @ahmedalsufachi3307
    @ahmedalsufachi3307 Před měsícem

    Can i fix the drain by myself!? Is that easy ??

  • @normls8615
    @normls8615 Před měsícem

    The concept is to buy a SH!T BOX, Not make one. FW!75

    • @FullyAirconditioned
      @FullyAirconditioned Před měsícem

      It all about raising money for charity and having fun while you do it. Spent less than $1500.00 on a car and drive it over 4000 km through some of Australia's most rugged off the beaten track roads and hope it makes it. Shitbox rally minimum requirement is UHF, Spare wheels and jerry can. They recommend getting the car checked out for basic mechanical repairs, car has to be road worthy, a bash guard is also highly recommended. We did all the recommended and painted the car, I would say 80% of the cars on the rally had been painted in some way. Car = $1, Paint ect = $95, stereo = $99.00, bash guard = $190.00, UHF = donated, handpiece cable for uhf ebay = $22, Car services free labour( filters, oil, air, cabin, wiper blades, light bulb = $114.00) , light bar = $39, (siren, loud speaker, battery, backup) = donated, singwrighting = donated, spare wheels = donated. All up we have spent less than $600.00, We raised $9,360.00, the 2024 winter Shitbox Rally event raised over 2.4 million for the Cancer council. A very successful event that we are proud to be part of.

  • @morpmorpt4746
    @morpmorpt4746 Před měsícem

    How do you reset a Daikon RZQ71LV1, Cant see an obvious reset button.

    • @FullyAirconditioned
      @FullyAirconditioned Před měsícem

      @@morpmorpt4746 what controller do you have ?

    • @morpmorpt4746
      @morpmorpt4746 Před měsícem

      @@FullyAirconditioned one on wall

    • @FullyAirconditioned
      @FullyAirconditioned Před měsícem

      @@morpmorpt4746 will that really helps, find the controller model, search for the manual on line, read manual and you should find it in there how to reset the filter.

  • @Lazyspaceout
    @Lazyspaceout Před měsícem

    Question I have smell that comes and goes with the AC, do you know the problem?

    • @FullyAirconditioned
      @FullyAirconditioned Před měsícem

      I am pretty good with air con, but not that good 🤪, try the tea tree oil it will kill any bacteria on the coil, when this bacteria gets wet it can smell

  • @SilverGreen93
    @SilverGreen93 Před měsícem

    Excellent and very helpful video! I cleaned my AC and now it doesn't smell anymore.

  • @sn.5755
    @sn.5755 Před měsícem

    I have a ducted system and a separate system for family room. The family I can go and adjust esp fan speeds. In ducted I change the speeds but it doesn’t change anything when running. The downstairs is very cold. Trying to increase fan speeds. Help would be appreciated

  • @tirx51
    @tirx51 Před měsícem

    Hi. Is there field setting to turn off defective gas sensor on FNA model? Thanks!

  • @ViserysTheFirst
    @ViserysTheFirst Před 2 měsíci

    Thank you vary much

  • @foxsports99
    @foxsports99 Před 2 měsíci

    Mate you’re a legend will see how I go. Issue I have is that the bedrooms have no power whatsoever but the living room heats up in my apartment. Is there a way you can change the power distribution across the different zones? Followed your instructions so let’s see. Also what does the S symbol mean? I did change the energy saving % is that it?

  • @Productofgodz
    @Productofgodz Před 2 měsíci

    Mine is flashing but I tried all the error codes none long beep only the heat mode opens the vents

  • @suthakarsenthooran1384
    @suthakarsenthooran1384 Před 2 měsíci

    New ac smell what problem

    • @FullyAirconditioned
      @FullyAirconditioned Před 2 měsíci

      @@suthakarsenthooran1384 how new ?? Have you checked all the points in the video ??

  • @Faisal_al_shammari
    @Faisal_al_shammari Před 2 měsíci

    Can i use mixer of IPA and water and will it be harmful is the futur

  • @chriskeo392
    @chriskeo392 Před 2 měsíci

    Preventative measures The folks who has one that smells already needs deep cleany

  • @hollycolotta9859
    @hollycolotta9859 Před 2 měsíci

    Great video! To the point and great tips. going to try! TY

  • @monacomulisha3928
    @monacomulisha3928 Před 2 měsíci

    Wow thank you! Way to make this system come alive! 4 bedroom house with like 7 vents. Turned it up to 10. What a major difference all this info made

  • @coolgomsy89
    @coolgomsy89 Před 2 měsíci

    How to come out of this error code mode. Cancel is keep giving the error codes in loop

    • @FullyAirconditioned
      @FullyAirconditioned Před 2 měsíci

      It should just time out, if all else fails pull the batteries out.