Daikin VRV IV-S commission procedures

Sdílet
Vložit
  • čas přidán 25. 08. 2024

Komentáře • 15

  • @m.haslam8495
    @m.haslam8495 Před rokem +1

    Fitted quite a few of the Daikin Mini VRV's. Extremely reliable. Never had a problem with any of them. 🇬🇧

  • @SirgalDelRchannel
    @SirgalDelRchannel Před rokem +1

    WOW! You did a fantastic job in showing this procedure.
    Big like for a wonderful work!

  • @SatnamSingh-us8kw
    @SatnamSingh-us8kw Před 2 lety

    Good commission great work 👍

  • @WickedComfortableVRF
    @WickedComfortableVRF Před 2 lety

    Awesome video

  • @kcomfortsystemshvac7060
    @kcomfortsystemshvac7060 Před 2 lety +1

    Nice Video,,,,,some size the air conditioning don’t need commissioning straits to cooling ,,,what size and capacity the air conditioning,,need to commissioning? From 24,000 BTU ? Up .?

    • @FullyAirconditioned
      @FullyAirconditioned  Před 2 lety

      Hi,
      If the indoor units are connected to the outdoor unit with a coms cable (f1, F2 connections) then it will need commissioning like in this video. The smallest capacity outdoor unit is 9.0kw or about 34,000 BTU. If the pipe work from each indoor unit is connected directly to the outdoor unit services valves than its a multi head and dose not need commissioning. The multi head outdoor units range in size from 5.0kw or 18,000 BTU to 10kw or 36,000 BTU.

  • @iwanrizkyanto6508
    @iwanrizkyanto6508 Před rokem +1

    Hii sir can you please answer my question ,i have VRV 4 inverter with 2 indoor ,so when i try to put test run,,starting running compressor 5 second after that cut off ,any idea ?thanks

  • @aus_aircon_ref_mech6671

    Great video. Thanks for all the information. 👍

  • @manidudematapitiya
    @manidudematapitiya Před 2 lety +1

    Can you tell me why is only one fan is working in my RXMQ6AVE air conditioner.
    Both fans work when I replace the circuit. Why is that ? What’s wrong with my previous card?

    • @FullyAirconditioned
      @FullyAirconditioned  Před 2 lety

      May be dew to load on the outdoor unit, this is a vrv outdoor unit with multiple indoor units, if the heat load of the indoor units is low, the load on the outdoor unit is also low. The outdoor may cycle off a fan so it dose not over condense (cool the liquid gas to much) in cooling mode. In heating the outdoor unit coil area is larger than the indoor coil and the amount of heat the outdoor coil can absorbs from outside air is greater that the heat it can off load at the indoor unit. In heating mode if its picking up to much heat from the outside air, it will super heat the Vapour gas returning to the compressor, reducing the ability to remove the electrical heat from the compressor motor, so it will cycle the fan to control the suction super heat.

  • @Indra_Ninja
    @Indra_Ninja Před rokem

    Do you have a video to clean one of these inverter units? I have a 4MXS80LVMA would be curious to how to clean one.

  • @sergeshevchuk1679
    @sergeshevchuk1679 Před 2 lety

    noise operation.

    • @FullyAirconditioned
      @FullyAirconditioned  Před 2 lety

      yes it has a reduced noise setting that can be set from the outdoor unit