Kamloops Fire Rescue Training Division
Kamloops Fire Rescue Training Division
  • 36
  • 27 308
6 Full Car Teardown Explanation & Demo
This is part instructional and a demo of a full car teardown (double dash displacement) Due to time, the roof flap forward is not part of this video.
zhlédnutí: 142

Video

CPE #6
zhlédnutí 161Před dnem
This evolution uses one Engine Company and four members, an aerial apparatus with four members, an elevated master stream appliance and supply line. This timed evolution begins when the aerial apparatus stops at the designated fire area, airbrake applied. The Engine joins the evolution immediately. Standard requirements:  The aerial apparatus stops at the designated fire area and prepares the ...
Emergency Blow
zhlédnutí 474Před 5 měsíci
When the patient needs to come out quickly, but we need the space, the "emergency blow" is an efficient means to do it.
KFR Post Fire Decontamination
zhlédnutí 43Před 5 měsíci
It goes without saying that structural firefighting is a dangerous occupation and the necessity to properly decon after an incident is just as important as after a hazmat incident....correctly stated it is a hazmat incident. The KFR approach to Post incident Decon.
Vehicle on it's Side - Strut Stabilization (2 Options)
zhlédnutí 220Před 5 měsíci
This video goes through two options for stabilizing a vehicle on its side using paratech struts. Option 1 is the 2 point stabilization and option 2 is the push pull.
Vehicle on its Wheels - Door Removal
zhlédnutí 174Před 5 měsíci
KFR Training "Plan A" door removal process. Music from Pixabay. Audio File Title: Stylish Rock Beat Trailer Audio File ID: 116346 Audio File Title: Cool Sport Rock Beat Audio File ID: 95429
100ft 1 3/4" Apartment Bundle
zhlédnutí 87Před 5 měsíci
This video demonstrates the optimal apartment bundle build from the knee. This version gives crews many options for deployments in various situations.
Tying a Halyard
zhlédnutí 304Před 6 měsíci
Tying a Halyard quickly and efficiently. Also known as the double clove.
6 Line Deployment and Entry Procedures
zhlédnutí 370Před 8 měsíci
6. Deploying 1 ¾ preconnect - The firefighter will deploy a 1 ¾ preconnect for the purpose of door entry and making fire attack. a. FF will be standing in full PPE and SCBA awaiting instruction from Training Officer. b. Upon instruction, FF will deploy appropriate 1 ¾ preconnect for the purpose of door entry. c. FF will demonstrate correct deployment of preconnect taking care to deploy to corre...
4 Deploy 35' Ground Ladder Part 2
zhlédnutí 406Před 8 měsíci
4. Deploy 35’ ground ladder - The Firefighter with another firefighter will deploy 35’ ladder to be used as a ground ladder. Multiple ladders will be deployed in a variety of ways to perform different tasks as instructed. IE: deployed on the beam, deployed flat, deployed for ventilation, deployed for rescue etc… a. FF will be standing in full PPE and SCBA awaiting instruction from Training Offi...
4 Deploy 35' Ground Ladder Part 1
zhlédnutí 496Před 8 měsíci
4. Deploy 35’ ground ladder - The Firefighter with another firefighter will deploy 35’ ladder to be used as a ground ladder. Multiple ladders will be deployed in a variety of ways to perform different tasks as instructed. IE: deployed on the beam, deployed flat, deployed for ventilation, deployed for rescue etc… a. FF will be standing in full PPE and SCBA awaiting instruction from Training Offi...
3 Deploy Single Fly Ground Ladder
zhlédnutí 444Před 8 měsíci
3. Deploy Single Fly Ground Ladder - The Firefighter will deploy a single fly “roof ladder” to be used as a ground ladder. a. FF will be standing in full PPE and SCBA awaiting instruction from Training Officer. b. FF will deploy a single fly ladder for use on the ground. c. FF will deploy ladder by themselves. d. FF will audibly verbalize the hazards they are looking for while deploying ladder....
2 Extended Attack
zhlédnutí 866Před 8 měsíci
2. Deploy 2 1/2 Preconnect - The Firefighter will deploy the 2 ½ preconnect and demonstrate correct “Exterior Water Application” technique. a. FF will be standing in full PPE and SCBA awaiting instruction from Training Officer. b. FF will deploy 2 ½ preconnect correctly according to T.O.’s instruction. c. FF will demonstrate correct Exterior Water Application technique. d. FF will then be instr...
5 Tying Tools for Hoisting
zhlédnutí 286Před 8 měsíci
5. Tying tools for hoisting - The Firefighter will tie a variety of tools for the purpose of hoisting. Tools included will be pike pole, axe, uncharged hose line, charged hose line, chainsaw, and roof ladder. a. FF will be standing in full PPE and SCBA awaiting instruction from Training Officer. b. Upon instruction, FF will tie the designated tools for the purpose of hoisting. c. FF will take c...
1 Catch a Hydrant
zhlédnutí 3,7KPřed 8 měsíci
1. The Firefighter will don appropriate PPE and will “catch” the hydrant. a. FF will be seated in the apparatus with appropriate PPE. b. The signal will be made for the FF to disembark the apparatus and catch the hydrant. c. FF will follow the correct sequence to establish a water supply and will charge the supply hose when instructed. d. FF will follow the supply hose back to the apparatus che...
CPE #5 Monitor Tank supply to Hydrant
zhlédnutí 134Před rokem
CPE #5 Monitor Tank supply to Hydrant
CPE #4 Tender Dump and Bladder Draft
zhlédnutí 357Před rokem
CPE #4 Tender Dump and Bladder Draft
CPE #3 Extended Attack
zhlédnutí 169Před rokem
CPE #3 Extended Attack
100' Hosepack & Coil Deployment
zhlédnutí 212Před rokem
100' Hosepack & Coil Deployment
CPE #1 Tank Supply to Hydrant Pump Transfer
zhlédnutí 290Před rokem
CPE #1 Tank Supply to Hydrant Pump Transfer
CPE #2 Relay Pumping
zhlédnutí 303Před rokem
CPE #2 Relay Pumping
High Rise - KFR First-In Engine Company
zhlédnutí 917Před rokem
High Rise - KFR First-In Engine Company
Single to Two-Rescuer Steep Slope
zhlédnutí 2KPřed rokem
Single to Two-Rescuer Steep Slope
Two-Rescuer Steep Slope Setup
zhlédnutí 10KPřed rokem
Two-Rescuer Steep Slope Setup
Rope Truck Loadout
zhlédnutí 526Před rokem
Rope Truck Loadout
KFR Cul-de-Sac Pack
zhlédnutí 278Před 2 lety
KFR Cul-de-Sac Pack
Triple Layer Load - The Straight Pull
zhlédnutí 2KPřed 2 lety
Triple Layer Load - The Straight Pull
Triple Layer Load -Shouldering it
zhlédnutí 238Před 2 lety
Triple Layer Load -Shouldering it
Triple Layer Load - Two-Person Split Deployment
zhlédnutí 277Před 2 lety
Triple Layer Load - Two-Person Split Deployment
Roof Removal
zhlédnutí 93Před 2 lety
Roof Removal

Komentáře

  • @thomascupello3199
    @thomascupello3199 Před 12 dny

    Great work guys

  • @jasonb3907
    @jasonb3907 Před 5 měsíci

    That was pretty cool to watch. I appreciate everything you guys do out there, and God Bless 👊😎

  • @dawolf7784
    @dawolf7784 Před 8 měsíci

    He didn’t wrap the hydrant with the hose . Could have gotten seriously hurt if the truck went to fast and the hose snapped around on him - LT on the FD

    • @kamloopsfirerescuetraining5089
      @kamloopsfirerescuetraining5089 Před 8 měsíci

      No, that can’t happen as he folds the coupling back on itself so if the hose gets caught somewhere, it just takes off without hurting him. That’s how we teach hydrants. We feel wrapping is unnecessary.

    • @dawolf7784
      @dawolf7784 Před 8 měsíci

      @@kamloopsfirerescuetraining5089 fair enough I guess , I know in our dept if you fail to wrap it’s a fail . Thxs .

  • @itisjambo
    @itisjambo Před 8 měsíci

    Flush the hydrant!

  • @christianendt296
    @christianendt296 Před 8 měsíci

    Why he did not flush the Hydrant? Nobody wants this brown Water Soup in the Tank.

    • @kamloopsfirerescuetraining5089
      @kamloopsfirerescuetraining5089 Před 8 měsíci

      We flow test all hydrants here every year and our water system is surprisingly clean...flushing has been determined unnecessary.

  • @marks79luv
    @marks79luv Před 8 měsíci

    LOL

  • @ryanhobbs3362
    @ryanhobbs3362 Před 8 měsíci

    Overall very well done. Everyone has that kind of oops from time to time. :)

  • @ShariahThomas
    @ShariahThomas Před 11 měsíci

    People keep being mean to me what should I do 0:10

  • @jont6556
    @jont6556 Před rokem

    Awesome video

  • @Hot.firefighters
    @Hot.firefighters Před rokem

    ❤️❤️

  • @mikekollross8810
    @mikekollross8810 Před rokem

    I’m curious about a couple of things. Not arm chair quarter backing just curious about your setup Why have the rescuers on the pick off straps when using the rigged prusiks gives you easier adjustability? Or does it? The tails of both lines could be secured to the foot of the basket. Or have you excluded that idea based on something? Good video with some ideas to compare to our setup. Thanks

    • @kamloopsfirerescuetraining5089
      @kamloopsfirerescuetraining5089 Před rokem

      The tails can be attached if you are worried about dragging on the ground. The reason for two is when packaging, both rescuers are independent and are not pulling each other back and forth. This is something that our department does a lot of and this just seems to work the best. The pickoff straps are for adjusting up and down and a a second point of contact which also keeps the basket front off the ground. Where we rescue is not always just a slope, there may be flat areas etc. The more adjustability we find the better. Makes for a bit more complicated system, but much of this is pre built and ready to go on our trucks. Thanks for the comment.

    • @ShariahThomas
      @ShariahThomas Před 11 měsíci

      @@kamloopsfirerescuetraining5089people keep being mean to me what should I do