Intermittent Low Voltage Short Hiding In Plain Sight!

Sdílet
Vložit
  • čas přidán 22. 02. 2024
  • In this video I visit a vacant house that had no heat and found a blown low voltage fuse! #hvacguy #hvaclife #hvactechnician #airconditioner #hvac #hvactrainingvideos #furnace #heatpump #hvacinstall #hvactroubleshooting #lowvoltage #lowvoltagenation
    Merch Store : hvac-guy-2.creator-spring.com
    HVAC LIFE FB Group: / 521086622906115
    Here are links to the tools I use, And it costs you nothing extra to buy from this list:
    Appion AV760: amzn.to/3OkrwHC
    Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
    Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
    Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
    Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
    Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
    Fieldpiece Bluetooth Scale: amzn.to/3Gzveab
    Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
    Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
    Milwaukee M12 Impact Driver: amzn.to/37xXkqk
    DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
    Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
    Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
    Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
    Klein Knee Pad: amzn.to/3cy6FB0
    Klein 7in1 Flip Socket: amzn.to/3bpabwG
    Klein Journeyman Pliers: amzn.to/3tvB60w
    Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
    Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
    Milwaukee Tool Box: amzn.to/322iyK9
    Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
    Milwaukee Hook Blade Knife: amzn.to/33F3m5T
    Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
    Western Nitrogen Regulator: amzn.to/3rmdKrx
    Klein Canvas Bucket: amzn.to/3FyzKVf
    Flag Velcro Patch Kit: amzn.to/3K8Eswx
    Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
    Milwaukee Magnetic Light: amzn.to/3FulCfF
    Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
    SS2 Float Switch: amzn.to/3K7LJMW
    3-Amp Breaker: amzn.to/3nxaSXJ
    Appion Valve Core Removal Tool: amzn.to/33CFArw
    Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
    Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
    Similar Small Tubing Bender: amzn.to/3fJsziJ
    Fluke Twist Guard Test Leads: amzn.to/3216R6j
    Fluke 975 Air Meter: amzn.to/3GwD9oM
    Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
    Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
    SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
    Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
    Quick Check Acid Test: amzn.to/3GA2XAy
    Aims Power Inverter: amzn.to/3qOSc87
    Wiha Torqe Screwdriver : amzn.to/3u1swH6
    Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
    American Flag Gator : amzn.to/3rKBl5u
    Compressor Tote: amzn.to/3H8xHst
    Inspection Mirror: amzn.to/3r9PERV
    Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
    1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Komentáře • 119

  • @Cmart270
    @Cmart270 Před 4 měsíci +29

    Been doing this for 18 years strong...... and Ohhhhhh goodness!!! Intermittent low voltage is always hard to track down, and alllllll kinds of strange things with the equipment, can occur!!! Pride you on your persistence!!!❤😅

  • @Zeviticus
    @Zeviticus Před měsícem

    These hard to find sources of fault are the best videos, especially low voltage. Thanks for posting!

  • @brianwaldo2642
    @brianwaldo2642 Před 4 měsíci +15

    What a Payne in the butt😂. Your dogged determination is appreciated.

  • @jthonn
    @jthonn Před 4 měsíci +7

    You finally got it. I thought a new wire was coming.

    • @zack9912000
      @zack9912000 Před 4 měsíci

      I have done thar a few times and it isnt always a bad thing. When the wire look like crap from sun damaged and hacks installs.

  • @cjeffcoat2
    @cjeffcoat2 Před 4 měsíci +9

    I’m sure these types of calls are very frustrating, but I do like the more in-depth videos.

  • @Bob.W.
    @Bob.W. Před 4 měsíci +8

    It's a Payne! :) Thanks.

  • @dfirth224
    @dfirth224 Před 4 měsíci +5

    I'm surprised to see that propane tank sitting next to the house. In CA they need to be at least 10', 25', or 50' from buildings, depending on the size of the tank.

  • @jimharmon3404
    @jimharmon3404 Před 4 měsíci +6

    It's like peeling a rotten onion. Layer by layer you find more rot but finally resolve it. Great job Curtis!

  • @jaymartin5095
    @jaymartin5095 Před 4 měsíci +7

    You are a man of exemplary patience. Good work getting that operational again. Thank you for posting.

  • @tedhicks5431
    @tedhicks5431 Před 4 měsíci +5

    At least you spotted the short its the one's you fix and never pin point the short fun ain't it

  • @kens.3729
    @kens.3729 Před 4 měsíci +5

    It would be Horrible to go up in the Attic especially in your Hot and Humid Georgia Summers. 🤪👎

  • @myfastcars
    @myfastcars Před 4 měsíci +9

    Have you ever opened up a panel and found an animal or insect surprise?? Love the channel and enjoy when you pop up in my feeds!!

    • @HVACGUY
      @HVACGUY  Před 4 měsíci +4

      Definitely

    • @bige859
      @bige859 Před 4 měsíci +2

      Service techs find animals all the time. I found a fried frog that’s leg was touching the common on the capacitor the other day😂

    • @gtpforever
      @gtpforever Před 4 měsíci +1

      I seem to find mice, bats, birds, and insects galore, nuts of all sorts, rats, the occasional opossum or raccoon

    • @jackdonovan2270
      @jackdonovan2270 Před měsícem

      Years ago I was replacing and old r22 janitrol condenser, threw the condenser up in my truck, (I was young) there was a 2’ baby rattler, right there⚡️⚡️
      Lucky I guess

  • @timothygingras6939
    @timothygingras6939 Před 4 měsíci +6

    Excellent work, Curtis. I admire your tenacity.

    • @HVACGUY
      @HVACGUY  Před 4 měsíci +2

      Thank you kindly!

  • @throttlebottle5906
    @throttlebottle5906 Před 4 měsíci +2

    the T-stat wires pinched through the cover caught my eye right away, now I'll finish watching to see if that was all or others things.
    **edit: the spot pinched under the disconnect I missed, but that will sure do it!
    well, that turned into an real time consuming sheet show! 😬 found in the end though, it's very hard to find sometimes.

  • @ErickHernandez93
    @ErickHernandez93 Před 4 měsíci +2

    Haha once i saw that vibration from the blower i figured it’d be in the man 😂😂

  • @mattliebenau9083
    @mattliebenau9083 Před 4 měsíci +3

    Intermittent low voltage problems stink. I was very happy when I discovered those Poppers and didn’t have to carry around 50 fuses. Good on ya for being persistent and I hope you got paid!

  • @5DangerRanger0
    @5DangerRanger0 Před 4 měsíci +4

    Carry some 40/40 connectors with you so when you find wires entering a metal enclosure without one you can throw one in.

  • @optionstraderman
    @optionstraderman Před 2 měsíci

    Great Video, love the troubleshooting part that most tech's never show.

  • @derek10w
    @derek10w Před 4 měsíci +4

    What a coincidence. A few weeks ago I went on a service call with a coworker who spent the previous day searching for a short. Thanks to a previous post on the HVAC reddit, one of the first things I did was look inside the heat pump and I found a pressure switch wire that was rubbing against a pipe and shorting out.

    • @charlespaine987
      @charlespaine987 Před 4 měsíci

      Why don’t the manufactures put in screw terminals in air handlers to land thermostat and condenser wires instead of the rats nest . Simplify installation make trouble shooting simpler with easy visual verification. A set of indicator led lights would be instant verification of function commands

    • @derek10w
      @derek10w Před 4 měsíci +1

      @@charlespaine987 add some float switches and condensate pumps to the mix 🤪

    • @charlespaine987
      @charlespaine987 Před 4 měsíci

      @@derek10w yes a terminal strip to land them on would save a lot of field chasing in the spaghetti of lose wires. There is no absolute cure for insulation errors but we could make it a lot easier for those that follow up in field work . I have worked in the field for years.

  • @kg4muc
    @kg4muc Před 4 měsíci +2

    Low voltage shorts for some reason seem to always be intermittent. Good job sticking with it! Have a nice weekend 😅

  • @Azzen234
    @Azzen234 Před 4 měsíci +2

    this is why, when i personally install a new hvac system, i always install THREE wire to the outdoor condenser if its a cool only, and an 8 wire if heat pump because if these issues... and an 8 wire indside ALWAYS

  • @josefmerritt1849
    @josefmerritt1849 Před 4 měsíci +3

    Thanks for the video, I enjoy watching how the thought process progresses when looking for these shorts

    • @HVACGUY
      @HVACGUY  Před 4 měsíci +1

      Glad you enjoyed!

  • @gregsidel3557
    @gregsidel3557 Před měsícem

    You done a damn good job you had several problems and you kept chasing it and you finally found it all of them plus you had to change out the dirty filter thank you for the video

  • @stevencossaboon3237
    @stevencossaboon3237 Před 4 měsíci +4

    Excellent troubleshooting and work Curtis.

  • @dashcamandy2242
    @dashcamandy2242 Před 4 měsíci +2

    22:30 - Would you say that you "still haven't found what you're looking for?" 🎶

  • @markcotter2355
    @markcotter2355 Před 4 měsíci +4

    wow that one gave you some trouble. good job.

  • @woody95124
    @woody95124 Před 4 měsíci +3

    Your very good bud....You know lot on this stuff.....

  • @AaronPowellvox
    @AaronPowellvox Před 4 měsíci +3

    Been there so many times. I found a fried caterpillar today trying to short high voltage. Poor dude didn’t stand a chance.

  • @deanmartin1966
    @deanmartin1966 Před 4 měsíci +4

    I enjoy the more in depth videos. Good video

  • @tylerdonley9130
    @tylerdonley9130 Před 4 měsíci +2

    I love how long it took to find this short. Who would have thank to look inside the condenser for rubs.

  • @wendelfears1027
    @wendelfears1027 Před 4 měsíci +3

    Smashed our faces into the insulation twice. We'll be inching the rest of the night.

  • @TomLawson05
    @TomLawson05 Před 4 měsíci +2

    Curtis that Payne was a pain glad you figured it out great job thanks for the video

  • @glenmartin2437
    @glenmartin2437 Před 4 měsíci +2

    Thank you.
    Intermittant problems are a challenge. Thanks for getting it running.

  • @caru3257
    @caru3257 Před 4 měsíci +3

    I had one where the homeowner replaced the thermostat and it burned it. The contactor was stuck open but the system did not blow the fuse at the transformer.

  • @robalexander7348
    @robalexander7348 Před 4 měsíci +3

    You done well Curtis with that annoying fault, i hope your next job is a more easy job to finish off with. 🤔 Au

  • @jonathanbrantley8406
    @jonathanbrantley8406 Před 9 dny

    Need to carry you around a 2'x3' -3/4" ply so you can have a plank to stand on over access holes and if you like you can screw it down so it doesn't move until done a lot better feeling than that sudden stop !

  • @user-ov9kd7uh3v
    @user-ov9kd7uh3v Před 4 měsíci +1

    Low voltage problems are always my personal hell. Great job!

  • @robavis4906
    @robavis4906 Před 4 měsíci +1

    Good job Curtis

  • @stevea6722
    @stevea6722 Před 4 měsíci +4

    Just wondering if some of that (thermostat, fuse, contactor) could have been caused by a lightning strike nearby that ran in on it.

  • @Emerickocsis
    @Emerickocsis Před 4 měsíci +3

    Excellent work i enjoy all your videos

    • @HVACGUY
      @HVACGUY  Před 4 měsíci +1

      Thank you very much!

    • @Emerickocsis
      @Emerickocsis Před 4 měsíci +1

      Do you work on any oil fired equipment down in Georgia

  • @Wade6242
    @Wade6242 Před 4 měsíci +4

    you,ll have dreams about that one

  • @Atchapa
    @Atchapa Před 4 měsíci

    Love your videos! Hvac’n out of Texas!

  • @Bjornar_Gjostol
    @Bjornar_Gjostol Před 4 měsíci +1

    Another good video, love the troubleshooting videos, have a great weekend. Greetings from Norway

  • @fairinwhite7694
    @fairinwhite7694 Před 3 měsíci

    I like th new camera and getting educated

  • @MrMultitool
    @MrMultitool Před 4 měsíci +1

    You did a great job.

  • @petersteffen9228
    @petersteffen9228 Před 4 měsíci

    In a severed case, sometimes a complete replacement of ALL the wires in the system starting from scratch, might bring good results.

  • @rickcrain8685
    @rickcrain8685 Před 4 měsíci

    Great job!!

  • @andys5203
    @andys5203 Před měsícem

    Thank you, sir. Awsome determination 😊

  • @chuckstillwell9549
    @chuckstillwell9549 Před 4 měsíci

    Good catch

  • @TheKawasakiBros
    @TheKawasakiBros Před 3 měsíci

    every time you put your hand on that suction line that boy goes crazy i think it might be there tbh but ill keep watching

  • @fernandobazan829
    @fernandobazan829 Před 4 měsíci +3

    Wow what a nightmare T/S but you did it great video fyi if you ring the wires you could have found it faster maybe?

  • @rafaelandreano
    @rafaelandreano Před 3 měsíci

    Quite a journey only to find out the pressures are low wow.

  • @KevinKinder-ey9gv
    @KevinKinder-ey9gv Před 4 měsíci +4

    Propane tank probably for stove or fireplace gas logs

    • @KenKen-ui4ny
      @KenKen-ui4ny Před 4 měsíci +1

      It could be also for a tankless water heater. There a few houses in my area too, that are set up with gas hot water, but the central heating is electric.

    • @KevinKinder-ey9gv
      @KevinKinder-ey9gv Před 4 měsíci +2

      Never thought of that

  • @AutomationDnD
    @AutomationDnD Před 4 měsíci +3

    That was a GOOD one (Not Easy)
    You were like a Hound sniffing a trail, & you keep circling & circling & eventually find the problem. Most of us who don't know HVAC would not even GET CLOSE to finding the issues , IF we even tried.
    & that looked like a fairly decent installation too---- aside from those basic wiring / shorting issues.

  • @bobgallo3775
    @bobgallo3775 Před 4 měsíci

    I used to find the low voltage wire shorted to the copper tubing in many Goodman/Amana units. After wrapping the wire, I would put a short piece of Armorflex on the tubing and wire tie so that it could not happen again. Hope you were able to recover most of the cost of this job, Curtis.

  • @clivejoyce9437
    @clivejoyce9437 Před 4 měsíci +1

    That disconnect probably controls all the street lights too 😂

  • @DJV94022
    @DJV94022 Před 4 měsíci +2

    With that dirty air filter im sure it made the unit quit running making the attic tenant (rat) go chew on the wire in hopes of making the unit kick on 😂

  • @josephtramutola592
    @josephtramutola592 Před 4 měsíci

    Sometimes you get a thing that I was told years ago they called faint voltage even though you see voltage it’s not necessarily true voltage so what I would take a contactor and if it can’t pull contact in, it’s not true voltage.

  • @m9ovich785
    @m9ovich785 Před 4 měsíci

    I'm surprised You didn't inspect the T-stat wire right at the corner of the cabinet and the cable under the Disconnect Box. 1st before anything else.. In the Tele, Satellite and sound Bizz, I had a knack to spot stuff like that and be suspicious and check it out..
    Thanks..
    Mike M.

  • @RedWhiteNBlade
    @RedWhiteNBlade Před 4 měsíci +2

    Hi Curtis, wanted to know if you encountered any probs on the M18 Vac Pump post-decay test (Lesson Learned is to purge hose/ zero out to ambient pressure from tee and hard reset) hope this helps. Dont condemn the battery

  • @MrMoon275
    @MrMoon275 Před 4 měsíci

    Wow you definitely earned your money on that service call alot of techs would probably leave it for the next person!

  • @myfastcars
    @myfastcars Před 4 měsíci +5

    LOL!! The way that inside unit was jumping around, That Fan is D I R T Y !! Man, that filter was NASTY!

  • @cafemolido5459
    @cafemolido5459 Před 4 měsíci

    Instead of having to walk outside to just see if the compressor kicks on, best use a baby monitor to monitor from inside.

  • @emptech
    @emptech Před 4 měsíci +2

    I didn't go to the end of the video, I ran out of time. Before you completed the job, did you install either a bushing, grommet, or "alligator teeth" in the hole of the junction box where the low voltage wires passed through? Also noticed where the stat wires follow the refrigerant lines as they passed under some sheet metal, did you tie the wires off so they can't rub out? I'm asking, what is going to prevent this problem from happening again? Jim

  • @Ogtonyg
    @Ogtonyg Před 4 měsíci +1

    Have they been quoted for replacement? That thing has definitely lived way past its design life. I wouldn't dump hardly any money into that system at this point but the customer wants what they want.

  • @harrydickson4575
    @harrydickson4575 Před 4 měsíci +4

    👍👍👍

  • @fairinwhite7694
    @fairinwhite7694 Před 3 měsíci

    Sounds better also

  • @4thlinegooner582
    @4thlinegooner582 Před 4 měsíci

    Yep, the outdoor unit definitely has that Carrier family rattle.

  • @chrissmith513
    @chrissmith513 Před 4 měsíci +2

    That's Dangerous in the Stairwell

  • @cyclingfan2010
    @cyclingfan2010 Před 4 měsíci

    Learned something so thank you. What light are you using?

  • @natepeterson7145
    @natepeterson7145 Před 4 měsíci

    I think we need to start being rude or saying something different to customers about how important regular filter changes are. I've been to many customers houses that I've documented that I was there because a severely dirty filter causes an issue or the issue. We need to explain it longer or just simply say if you want to loose over $300 or more because you saved $100 worth of filters and risk damaging your $7000 plus investment than don't get mad. Especially if I charge double the price for the filter and a service fee for 10 minutes of work. If im busy and a furnace is going off on limit im replacing or removing the filter, checking temp rise and leaving. Of course this is a different issue but could easily be blamed on the filter. Filter causing the blower to work harder causing it to vibrate and causing the rub outs. Thanks for the business.

  • @TheKawasakiBros
    @TheKawasakiBros Před 3 měsíci

    low voltage cam be a payne lol couldn't pass up the chance

  • @JAWmankato
    @JAWmankato Před 4 měsíci +2

    What brand of light are you using?

  • @waltdembeck4634
    @waltdembeck4634 Před 4 měsíci +2

    why in the world do they put the inside unit where you either cant get to it or like this one can't hardly work on it, must be the same people who make cars.

  • @bruceorourke5432
    @bruceorourke5432 Před 4 měsíci

    How do you like using those Fieldpiece transducers and vacuum gauge hoseless or Wireless whatever you want to say

  • @jeanlawson9133
    @jeanlawson9133 Před 4 měsíci

    Someone should make a wood insert for the ladder hole 😮

  • @tedlahm5740
    @tedlahm5740 Před 4 měsíci +2

    no light up in the attic?

  • @TheKawasakiBros
    @TheKawasakiBros Před 3 měsíci

    so if you getting high ohms on 24 volt your grounding some where? whats the regular ohms on it if its working properly?

  • @topher8634
    @topher8634 Před 4 měsíci +1

    That looks like a 3 phase 100 amp disco

  • @butlerstouchHVAC
    @butlerstouchHVAC Před 4 měsíci

    can someone explain to me why he 9:43 was checking megahohms to ground and what should his reading been?

  • @user-sn2gd5dn8q
    @user-sn2gd5dn8q Před 4 měsíci +2

    How much did you end up charging for that

  • @otisgregory5939
    @otisgregory5939 Před 4 měsíci

    Drives me crazy when guys twist wire nuts so tight that it starts to braid the 2 wires . You're creating a weak point , twist until snugg never braid your 2 wires together

  • @fairinwhite7694
    @fairinwhite7694 Před 3 měsíci

    Sounds like the draft fan is out of balance and vibrating

  • @karellodewijks4971
    @karellodewijks4971 Před 4 měsíci

    👍👍😊😊

  • @n.harper2652
    @n.harper2652 Před 4 měsíci +2

    Was the blower out of balance?

    • @nikkid4798
      @nikkid4798 Před 4 měsíci

      It was running rough wasn't it. I thought for sure the disconnect rubbed a hot spot. 😅

  • @AdamCraig-ir6yl
    @AdamCraig-ir6yl Před 8 dny

    See curtis, this is what we want to see. We dont wanna see dirty units or bad caps. We wanna see the sloppy stuff. Other people post same ez stuff all the time

  • @woodystokes1543
    @woodystokes1543 Před 4 měsíci

    Ginormous 😮

  • @robertlamey7612
    @robertlamey7612 Před 3 měsíci

    Couple of hundred for 2 hours is way to cheap

  • @andrewclarke3622
    @andrewclarke3622 Před 4 měsíci +3

    Is this a dual-fuel system? I noticed the small propane tank.

    • @HVACGUY
      @HVACGUY  Před 4 měsíci +2

      No, just a heat pump

  • @stevedavidson8802
    @stevedavidson8802 Před 4 měsíci +2

    Are your customers cool with you making CZcams videos on their dime? I surely wouldn’t can’t do that in California it’s for sure.

    • @derek10w
      @derek10w Před 4 měsíci

      What do you mean on their dime? Are you setting a timer and charging by the minute?

    • @nikkid4798
      @nikkid4798 Před 4 měsíci

      I thought Cali was laid back? When you work for yourself, you do what you want. That wasn't a couple of hundred dollar job either. 3 hours, a contactor, thermostat and freon.. sheet man that's at least $750.

  • @arturofromtucson6262
    @arturofromtucson6262 Před 4 měsíci

    I would’ve caught that in the first 15 minutes of being there

  • @rkochair
    @rkochair Před 4 měsíci

    Well, I have to say Curtis you have "It" all right. You either have "It" or you don't have "It". Patience that is. It's like an electrician that spends 4 hrs trouble shooting an issue only to find a loose neutral somewhere that caused the entire problem and of course many customers are like "Ok, this must be cheap because it was just a loose (shorted) wire right?" You pay for experience and the "It" factor.......well done sir. On a different note - LP tanks can be placed right next to a home there? Asking because here in Calif. it's 10' min. Maybe an earthquake thing.