TXV Replacement on Ruud Air Handler!

Sdílet
Vložit
  • čas přidán 28. 08. 2024
  • In this video I return to the system I was at yesterday to replace the TXV! #hvacguy #hvaclife #hvactechnician #airconditioner #hvactrainingvideos #hvac #heatpump #furnace #hvactroubleshooting #hvacinstall #txv
    Merch Store : hvac-guy-2.cre...
    HVAC LIFE FB Group: / 521086622906115
    Here are links to the tools I use, And it costs you nothing extra to buy from this list:
    Appion AV760: amzn.to/3OkrwHC
    Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
    Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
    Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
    Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
    Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
    Fieldpiece Bluetooth Scale: amzn.to/3Gzveab
    Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
    Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
    Milwaukee M12 Impact Driver: amzn.to/37xXkqk
    DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
    Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
    Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
    Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
    Klein Knee Pad: amzn.to/3cy6FB0
    Klein 7in1 Flip Socket: amzn.to/3bpabwG
    Klein Journeyman Pliers: amzn.to/3tvB60w
    Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
    Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
    Milwaukee Tool Box: amzn.to/322iyK9
    Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
    Milwaukee Hook Blade Knife: amzn.to/33F3m5T
    Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
    Western Nitrogen Regulator: amzn.to/3rmdKrx
    Klein Canvas Bucket: amzn.to/3FyzKVf
    Flag Velcro Patch Kit: amzn.to/3K8Eswx
    Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
    Milwaukee Magnetic Light: amzn.to/3FulCfF
    Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
    SS2 Float Switch: amzn.to/3K7LJMW
    3-Amp Breaker: amzn.to/3nxaSXJ
    Appion Valve Core Removal Tool: amzn.to/33CFArw
    Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
    Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
    Similar Small Tubing Bender: amzn.to/3fJsziJ
    Fluke Twist Guard Test Leads: amzn.to/3216R6j
    Fluke 975 Air Meter: amzn.to/3GwD9oM
    Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
    Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
    SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
    Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
    Quick Check Acid Test: amzn.to/3GA2XAy
    Aims Power Inverter: amzn.to/3qOSc87
    Wiha Torqe Screwdriver : amzn.to/3u1swH6
    Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
    American Flag Gator : amzn.to/3rKBl5u
    Compressor Tote: amzn.to/3H8xHst
    Inspection Mirror: amzn.to/3r9PERV
    Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
    1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Komentáře • 67

  • @kens.3729
    @kens.3729 Před 5 měsíci +13

    These Free Videos are Much Better than Pay TV. 🤔😬👍🙏

    • @HVACGUY
      @HVACGUY  Před 5 měsíci +3

      Glad you like them

    • @mplewis5388
      @mplewis5388 Před 5 měsíci +1

      You are 100 percent correct

  • @warenmann1042
    @warenmann1042 Před 5 měsíci +3

    Good job, Watching you reinforces what I had planned to do to mine and gives me the confidence to tackle mine tomorrow AM. Good video. Thank You...

  • @key-sendo
    @key-sendo Před 5 měsíci +6

    The OCD tech in me is telling me that there is something wrong with the existing refrigerant in there, that charge did not seem correct to me. the fact that the subcooling wasn't really changing and the superheat was low after running for a while is giving me mixed thoughts. Still a job well done though, Curtis.

    • @famousdude1239
      @famousdude1239 Před 5 měsíci

      70F indoor air in heat mode and 366 is high? I stopped playing with refrigerant charge 15 years ago. Weight it IN.

  • @thwompalot5000
    @thwompalot5000 Před 5 měsíci +5

    Wouldn't be a real HVAC video without a broken mirror.

  • @u2b4every1
    @u2b4every1 Před 5 měsíci +1

    i would consider and then title this video as a masterclass of pulling deepest vaccume and balancing pressures on "heatpump" units - "deep pumpin"!

  • @user-su5ft8lc9q
    @user-su5ft8lc9q Před 5 měsíci

    Oh yea Curtis is the Guru of Hvac in Georgia. He's the BESTEST od the Best.!!!!!

  • @robalexander7348
    @robalexander7348 Před 5 měsíci +4

    Well done job Curtis, and a nice clear quality vid 👍 Au

  • @DevinHVACInc
    @DevinHVACInc Před 5 měsíci +2

    Another happy client.

  • @TomLawson05
    @TomLawson05 Před 5 měsíci +5

    Good job Curtis on the repair enjoyed it thanks for the video

    • @HVACGUY
      @HVACGUY  Před 5 měsíci +1

      Glad you enjoyed it.

  • @stephenbullock-yn3vh
    @stephenbullock-yn3vh Před 5 měsíci +6

    Great job Curtis

  • @stevencossaboon3237
    @stevencossaboon3237 Před 5 měsíci +2

    Great job Curtis.

  • @davidca96
    @davidca96 Před 5 měsíci +3

    Excellent work Curtis

    • @HVACGUY
      @HVACGUY  Před 5 měsíci +3

      Thanks

    • @kennyjohnson4411
      @kennyjohnson4411 Před 5 měsíci +2

      Nice job Curtis! I have the exact same wrenches. They work great

  • @kg4muc
    @kg4muc Před 5 měsíci +2

    Good job as always!! Btw. Like that red shirt it really stands out with your logo. Sort of a comfortable method of free advertising 😅. Take care of that hand!

  • @jon4455
    @jon4455 Před 5 měsíci

    Nice new bag Curtis you should do a tour video of it and your thoughts on the bag so far.

  • @donrummerfield2903
    @donrummerfield2903 Před 5 měsíci +3

    Nice new bag❤

  • @kennymayo4578
    @kennymayo4578 Před 5 měsíci +2

    Your mak8ng want to purchase one of those vacuum pumps, it really does a good job

  • @coldiez1464
    @coldiez1464 Před 5 měsíci

    Curtis. Thank you for your videos. Excellent content, I watch them with my sons. Keep making them please!

  • @Hvac-dude
    @Hvac-dude Před 5 měsíci +2

    Good job my friend 😊

    • @HVACGUY
      @HVACGUY  Před 5 měsíci +2

      Thanks 😄

    • @Hvac-dude
      @Hvac-dude Před 5 měsíci +1

      @@HVACGUY anytime 😊 I juat got a acutlene torch no oxygene just acytelene I like it better 😊😊 got a btank !!

  • @Electric-Air-Service
    @Electric-Air-Service Před 5 měsíci

    Another great video...

  • @jthonn
    @jthonn Před 5 měsíci +2

    Nice job!

  • @scottmaz4063
    @scottmaz4063 Před 5 měsíci +2

    Job well done Curtis

    • @HVACGUY
      @HVACGUY  Před 5 měsíci +1

      Thanks

    • @Empty7775
      @Empty7775 Před 5 měsíci +2

      Wonder why the subcooling was so low in cool mode? Was it because of the outdoor temp being 70?

    • @HVACGUY
      @HVACGUY  Před 5 měsíci +2

      @@Empty7775maybe. I’ve seen it many a time before system can settle out, or with no load

  • @Jaylenn.
    @Jaylenn. Před 5 měsíci +1

    Okay I think I’m getting it now. When doing a pump down if pressures not changing or if pressures not dropping at all The TXV Faulty or Plugged.

  • @harrydickson4575
    @harrydickson4575 Před 5 měsíci +2

    👍👍👍

  • @iraregister7589
    @iraregister7589 Před 5 měsíci +2

    Will they approve all new refrigerant when replacing an expansion valve?

  • @garypoplin4599
    @garypoplin4599 Před 5 měsíci

    28:44 - Wow! Your probe shot from 189.0 to 241.5 in one update?!o

  • @seanbaker2946
    @seanbaker2946 Před 3 měsíci

    Sounds like a SpaceX rocket, brazing.

  • @adrianstanton2652
    @adrianstanton2652 Před 5 měsíci +2

    Hello Curtis
    My question is what was the fluid dripping from the lower connection on the TXV removal? Condensation? Oil?

  • @mainj54
    @mainj54 Před 5 měsíci +1

    I thought those refrigerant tanks have check valves so as not to allow flow into tank.

    • @HVACGUY
      @HVACGUY  Před 5 měsíci +1

      They do. Sometimes they’ll allow a little to bleed by

  • @meridianline7291
    @meridianline7291 Před 5 měsíci +2

    Most liked micron gauge?

  • @mplewis5388
    @mplewis5388 Před 5 měsíci +2

    What causes the white discoloration on the copper ??

    • @HVACGUY
      @HVACGUY  Před 5 měsíci +3

      That was an aluminum coil

    • @mplewis5388
      @mplewis5388 Před 5 měsíci +1

      @HVACGUY wow! Here I only thought they had copper with aluminum learned something new again. Hope your finger is getting better.

  • @kennymayo4578
    @kennymayo4578 Před 5 měsíci +3

    Shouldnt the sensing bulb be horizontal at 10:00 or 2:00 position on Rheem/Ruud?

  • @UsaHickTown
    @UsaHickTown Před 5 měsíci

    If this was a drain down and vacuum where is the recovery tank for the Freon and the vacuum pump? Perhaps I blink when watching. Someone please let me know what was the timeline when he talked about that or shared about that. Thks

  • @markcotter2355
    @markcotter2355 Před 5 měsíci +1

    seems to be an air flow issue also.

  • @lip_ripper9231
    @lip_ripper9231 Před 3 měsíci

    Shouldn't the bulb be horizontal, not vertical?

  • @UrenaDomingo
    @UrenaDomingo Před 5 měsíci +1

    Where is the link for the Hispanic chanel?

    • @HVACGUY
      @HVACGUY  Před 5 měsíci

      At the end the picture of me in a hat is a clickable link to it

  • @anthonybuonagurio-gl9bg
    @anthonybuonagurio-gl9bg Před 5 měsíci +2

    You need to use open end wrenches instead of the adjustable

  • @seanbaker2946
    @seanbaker2946 Před 3 měsíci

    Bro props. That's a shitty fuckin spot

  • @billmooney6459
    @billmooney6459 Před 5 měsíci +3

    stop with the adjustable wrenchs .try a slighty bigger bag with the proper wrenchs .you will save time and damage to fittings .they should ban adjustables coming from mechanic since 1976 .they should be used only needed