AIRCONDITION & PROVISION REFRIGERATION TROUBLESHOOTING, SHIP'S HVAC

Sdílet
Vložit
  • čas přidán 10. 07. 2024
  • This is our onboard Provision and Aircondition Set up.
    #reefer #refrigeration ##refrigerationcycle #refrigerationequipment #seafarer #seaman #hvac #airconditioner

Komentáře • 43

  • @olegshulga4122
    @olegshulga4122 Před 2 lety

    Thanks for such usefull video! Respect

  • @Anabai15
    @Anabai15 Před 2 lety

    napakahusay malinaw madaling intindihin at tamang tama lang ang boses sir maraming salamat at laging ingat sir. More power.

  • @walter1007
    @walter1007 Před rokem

    awesomem, i’m korean and apparentice engineer. keep up the good work bro.

  • @Tutorial_Ref_Aircon_more

    Ganda naman ng mga ginagawa mo sir

  • @JCTechtips
    @JCTechtips Před 2 lety

    Thank you for the usefull video sir

  • @kc0eks
    @kc0eks Před 2 lety

    Very nice video thanks!

  • @johnalbertmamaril4496
    @johnalbertmamaril4496 Před 2 lety

    nice

  • @rb1m426
    @rb1m426 Před 2 lety

    Mr. Secretary grabi ka banggi itan sa technical ba.. recommend ko dha beh 😊😁😁

  • @mithileshramteke3882
    @mithileshramteke3882 Před rokem

    Thank you sir

  • @sriparameshwariharvestersu8148

    👌👍👍💯

  • @sharpjayavarmanjayavarman2475

    Sir ..plz discuss about refrigeration back pressure valve and unloader valve

  • @sportsroad4375
    @sportsroad4375 Před 2 lety

    Hello hvac technician din ako same lang tayo ng binabantayan child water

  • @SaravanaKumar-px9rh
    @SaravanaKumar-px9rh Před 2 lety

    Pls make video for charging gas in reefer container

  • @engineinstructorkirbydadol5736

    Continuation, pls.

  • @pranayborker7498
    @pranayborker7498 Před rokem

    Sir can you please make video on how to do transformer changeover onboard. ??

  • @rhodeislandred359
    @rhodeislandred359 Před 11 měsíci

    Sir lecky,, ano po ang nag pa trigger ng compressor para umandar? Salamat

  • @jestinv9768
    @jestinv9768 Před 2 lety +1

    Actually the accumulator is located after the condenser right and it's purpose is use to store excess liquid refrigerant...so then y the accumulator connection is given after the evaporator and at the outlet of the evaporator it will be vapour right??

    • @leckyjake
      @leckyjake  Před 2 lety

      it is for the compressor oil that gets to the system

    • @akshayloverboy
      @akshayloverboy Před rokem

      After condenser is liquid reciver usually used fo storing refrigerant during pump down and during normal cycle it lets refrigerant in liquid state to pass to dryer. On suction before compressor Is accumulator it only let's refrigerant in vapor state enter into compressor, to prevent any damages to compressor.

    • @RAJASEKAR-jb9to
      @RAJASEKAR-jb9to Před rokem

      The accumulator placed before the compressor, suction side of the compressor is connected to the accumulator , and it helps in two ways ,
      1. excess oil won't come to compressor
      2.cooled liquid won't come to the compressor, if it is directly connected the compressor would die

  • @xyronjamesbardinas2508
    @xyronjamesbardinas2508 Před rokem +1

    Hello boss, what is the reason our provision freezer breaker always trip? Just we finish clean this freezer cooler yesterday

    • @leckyjake
      @leckyjake  Před rokem

      you better do an insulation and continuity test on your compressor and evap fan motor

    • @noelfraga2999
      @noelfraga2999 Před rokem

      Kung electrical ka check mo compressor gumamit ka meager tester kung meron ka.. Pati fan motor evaporator tester mo kung grounded..

  • @romeltero9309
    @romeltero9309 Před rokem

    sir paano po yung pag umandar po meron freon sa condenser tapos kapag pumara na or pump down wala po nakocollect na freon po?

  • @chicodgreat2194
    @chicodgreat2194 Před rokem

    good day sir...
    anu kaya probable cause n nwala ung oil at refregerant s AC nmin onboard..we already check the possible leak pro wala kmi makita..any suggestion guys..salamat

  • @lokeshlokeshkumar2107
    @lokeshlokeshkumar2107 Před 2 lety

    Hai

  • @DaryllBizares
    @DaryllBizares Před 9 měsíci

    sir mechanical enguneer ka po ba ?

  • @wilsonmarvel8737
    @wilsonmarvel8737 Před rokem

    Leckyjake you too much

  • @antonyzairaz7627
    @antonyzairaz7627 Před 11 měsíci

    Fish room temp. Not reaching up to -18dig. Only up to -13dig. Please advise

  • @randomvideoschannel5977

    Sir Saan pwde kumuha ng training na ito

  • @prinardadventures3791
    @prinardadventures3791 Před rokem +1

    Sir hnd bumababa temp ng meat at fish kulang sa lamig pero ang veg ok nmn tpos wlang ice build up sa evaporator ung refrigerant is half level is it txv replace or adjust?? Or what other causes bkt d lumalamig ok nmn watertight doors sealed

    • @leckyjake
      @leckyjake  Před rokem

      Ilan temp

    • @prinardadventures3791
      @prinardadventures3791 Před rokem +1

      @@leckyjake -12 fish -9 meat then hanggang jan lng po

    • @prinardadventures3791
      @prinardadventures3791 Před rokem

      @@leckyjake bale nung nalaman ko na d nag low temp ang reading at -2 at -3 lng ang meat at fish nag ice kunti ang evaporator then binanlawan ko mbuti aun hanggang -9 at -12 lng nag bago nmn kht kunti tpos pumapara na ung sa meat pag na reach nya ung -9 nkita ko pumara solenoid then again hanggang -9 pa din after

    • @prinardadventures3791
      @prinardadventures3791 Před rokem

      @@leckyjake nagsimula sya nung nag provision kmi 5 hours un nkapara ang pinara ko lng is liquid solenoid valve switch hnd ko na pinump down kc gnun dn nmn gngawa ko before ok nmn

    • @leckyjake
      @leckyjake  Před rokem

      Baka naman naka set ka ng ganyan sa thermostat mo na - 9? Pm mo pictures sa leckyjake fb page.

  • @jonathancayabyab5074
    @jonathancayabyab5074 Před 2 lety

    sir baka pwde proper procedure ng pag pump down.
    salamat

  • @faiyazpmkvy788
    @faiyazpmkvy788 Před rokem

    How to apply?

  • @Tutorial_Ref_Aircon_more

    Hindi ako naka subok ng mga ganyan