REFRIGERATION PUMP DOWN AND HOW TO CHANGEOVER COMPRESSOR?

Sdílet
Vložit
  • čas přidán 14. 07. 2022
  • Here is the step by step procedure on how to pump down the provision refrigeration system onboard as well as the correct way on how to changeover the compressor.
    #reefer #refrigeration #refrigerationcycle #refrigerationequipment #seafarer #seaman #airconditioner #hvac #refrigerationandairconditioning #leckyjake #electrician #electric

Komentáře • 82

  • @mahmoodhassan4537
    @mahmoodhassan4537 Před 6 dny

    The best ETO on the planet 👌

  • @arielcunanan4994
    @arielcunanan4994 Před rokem

    Excellent tutorials

  • @eduardcalong796
    @eduardcalong796 Před rokem

    Thank you for this knowledge master lecky jake.. I had learn a lot.

  • @scorpiomarine-electrocutio7460

    Goodjob.this is very informative sir lecky.

  • @akarl6578
    @akarl6578 Před rokem

    You are the best. Thank you from Greece

  • @pedrojardim1163
    @pedrojardim1163 Před 2 lety

    Thanks for the very helpful and very good explanation 👍

  • @BernieQuinia-fl3ed
    @BernieQuinia-fl3ed Před 3 měsíci

    T.y sir to gud explaination.gud bless

  • @dennisabad7862
    @dennisabad7862 Před rokem

    full of information
    thank you sir for the free knowledge.

  • @princefernandes5789
    @princefernandes5789 Před 2 lety

    Excellent job 👏👏👏🛠🔧🛠🔨🔧 good explanation 😎😎😎😎

  • @dennisdumale5599
    @dennisdumale5599 Před rokem +1

    Thank you so much sir jake for these video. More power sir. And keep safe always. God bless to u & to ur famly🙏

  • @LinkWrayisGod
    @LinkWrayisGod Před 2 lety

    Nice one Lecky! Greetings from Spain.

  • @Winstly
    @Winstly Před rokem

    husay sir!!!

  • @antonioreyes7476
    @antonioreyes7476 Před rokem

    Another learning from my favorite CZcams channel. Mabuhay po kayo leckyjake.

  • @edwardjackson8183
    @edwardjackson8183 Před rokem

    😱🤯.. you blew my mind

  • @markvillaspin6643
    @markvillaspin6643 Před 8 měsíci

    Thank you Lect God Bless

  • @kiageungwirengrana5374

    Many thanks my bro

  • @aaronjettroehidalgo534
    @aaronjettroehidalgo534 Před 11 měsíci

    Thank you sir!

  • @babaolowo35
    @babaolowo35 Před rokem

    Thanks 👍

  • @judebrosas4663
    @judebrosas4663 Před 10 měsíci

    Thank you sir this is a big help to me...thank you❤

  • @mahboobKhan-uy7sm
    @mahboobKhan-uy7sm Před měsícem

    ❤❤❤❤❤

  • @Tutorial_Ref_Aircon_more
    @Tutorial_Ref_Aircon_more Před 2 lety +1

    Thank u for sharing sir

  • @fenflyer
    @fenflyer Před rokem +1

    Thanks for great videos 👍
    Good video on twin compressor pump down 👍can you do video on inverter scroll refrigeration compressors , please 👍
    I only worked on old twin 120 KW Sabroe piston compressors systems Amonia and R22 etc 😑
    Thanks for great videos 👍

  • @paologringoescalante6916

    Maraming salamat po. ❤

  • @akarshanilkumar3461
    @akarshanilkumar3461 Před 2 měsíci

  • @syedbasheer8210
    @syedbasheer8210 Před 2 lety +1

    👍👍👍

  • @joseenricoaguila5218
    @joseenricoaguila5218 Před 2 lety +1

    thank you

  • @markpaulofacun
    @markpaulofacun Před rokem

    👍

  • @dhruvrajchauhan4126
    @dhruvrajchauhan4126 Před rokem

    Thank you

  • @yousefhaeiri360
    @yousefhaeiri360 Před 2 lety +2

    Hi Lecky,thanks a lot please make an introduction video about the Boilers

  • @man15h
    @man15h Před 2 lety +3

    Hello sir can you please suggest a book for understanding single line diagram and learn about switch gear and Power systems protection, relay setting and fault current calculation

  • @bt9604
    @bt9604 Před 2 lety

    Sir, plz do a video on insulated neutral system in ship 🙏🏻

  • @rb1m426
    @rb1m426 Před 2 lety +1

    Present mr. Secretary 😊 about sa plc naman Sec.

  • @erwinhutapea2091
    @erwinhutapea2091 Před rokem

    Thank you so much sir .. sir I will ask about high pressure. if vegetable ekspnsi V/v open high pressure more up until 1.8 and then direct trip .. iwhat problem sir?

  • @studywithssr338
    @studywithssr338 Před 2 lety

    Sir please video on circuit diagram reading

  • @manzillegal1
    @manzillegal1 Před 10 měsíci

    Leckyjake hello leck could you also make video of procedure of vaccum of the system too weather Aircon or reefer thanku you ver much in advance🙏

  • @jishnur9770
    @jishnur9770 Před 2 lety +1

    Hi Lecky, Frst of all thank you for your wonderful easy explanation on each of your video. Im having a trouble on my ushio ref system, which is no 1 compressor is getting frosted if i let the system run. Now i changed over to no:2 not pumping down , but by charging no 2.
    What may be the probable reasons for the frosting, no fluctuation in suction and discharge pressure. R417A was charged on no:1 last week.

    • @leckyjake
      @leckyjake  Před 2 lety +1

      i always depend on the pressures. but most of the times if you have frost in the suction you might have an overcharged of refrigerant

    • @jishnur9770
      @jishnur9770 Před 2 lety

      Thank you and hats off for the dedication towards sharing your experience. Always waiting for your videos.

    • @stonecold1553
      @stonecold1553 Před rokem +1

      Hi just want to share my insight. The trouble is your compressor is getting frosted. One main reason, the refrigerant on the suction line all the way to the compressor is not in vapor/gas form. A lot of reason way this happened, most notorious one is overcharge, malfunctioning expansion device, dirty/clogged evaporator coil, and etc. But base on the scenario you have stated it is more likely overcharge.

  • @kuldeepsingh8486
    @kuldeepsingh8486 Před 2 lety +1

    Thank you sir can you make video for same A.C change over . And can make video on main engine course in simple way.

  • @torohdelapan8352
    @torohdelapan8352 Před rokem

    Please give education how to change oil the provision ref machine..thx

  • @amoscolod1519
    @amoscolod1519 Před rokem

    a very good explanation sir. you said that we need to run the compressor two times so if during the first time the low pressure switch activates how can we restart again the compressor or how will the compressor start again? will the pressure increase itself due to remaining refrigerant on the system?

    • @ivanfmartinezm
      @ivanfmartinezm Před rokem

      You can force to start pushing manualy the main contactor from the compressor about 3 or 5 seconds.

  • @rafaelhijara9534
    @rafaelhijara9534 Před rokem

    So the switch of compressor is off already before the closing the service valve? Am i right?

  • @thantzinaung6650
    @thantzinaung6650 Před 11 měsíci

    Sir, When you were pumping down the condenser of unit 1, the unit 1 was running in auto mode ?

  • @Tech-NO-City
    @Tech-NO-City Před 2 lety

    Next time please add "What not to do" I learn more by learning from others mistakes.

  • @jrahul8136
    @jrahul8136 Před 2 lety +2

    Please share how to trace electrical wiring diagrams...for example motor and starters circuit

    • @leckyjake
      @leckyjake  Před 2 lety

      I normally include the tracing on my troubleshooting videos

  • @antenehberhanu4467
    @antenehberhanu4467 Před 4 měsíci

    My dear what is the problem of freezer room start and stop again and again even if refrigrant gas is infe amount in the system

  • @freemind6231
    @freemind6231 Před rokem

    sir. acceptable npoba yung negative 17 s meat storage? gusto kc nila negative 20 medyo naggalangan ako galawin . tnx

  • @JerinMathew-rr6qs
    @JerinMathew-rr6qs Před rokem

    Why crack open for suction side valve ??

  • @cck1496
    @cck1496 Před rokem +1

    Thanks but why do we need the system to be pumped down? Why we can't keep one compressor off (rather than isolating it)?
    Thanks.

    • @leckyjake
      @leckyjake  Před rokem

      normally the changeover is being done every month, you do not want any refrigerant in the line for the non running compressos as in will condense in the latter.you do not want liquid state refrierant to enter into your compressor.

  • @elecbaskogpogi2086
    @elecbaskogpogi2086 Před 2 lety +1

    Good day lec. I have a question I experience during pumping down discharge pressure is increasing until high pressure trip activated and suction pressure is not decreasing hard to activate the low pressure switch. What is the cause?
    For that reason I cannot properly pump down and changeover to another one compressor.
    Hope it will answer Thank you in advance.

    • @leckyjake
      @leckyjake  Před 2 lety +1

      first, the cooling should still be present during pump down.
      you can adjust the setting of your discharge pressure switch as per your manual max limit.
      3rd. check for leak test on your suction side. the pressures you may be getting is the air that is goibg through your system

    • @elecbaskogpogi2086
      @elecbaskogpogi2086 Před 2 lety

      @@leckyjake thank you. Have a good day ahead.

  • @joalpsengineman4717
    @joalpsengineman4717 Před 2 lety

    Sir asan maganda .mag training sa pilipinas about electrical and reefer dto ako sa US as a Merchant Marine sa APL mahal ang training dto nasa $20k per training ng reefer at electrician and it takes 6 months

  • @bhongtorbs5685
    @bhongtorbs5685 Před rokem

    Crack open lng ba talaga yan sir yong suction normaly? Or i full open mo rin yan.

  • @teslapower220
    @teslapower220 Před rokem

    Haven't reefer containers made these systems obsolete?

  • @davidosei9560
    @davidosei9560 Před 2 lety +1

    Hello sir , I’m having a bachelors degree in Electrical and Electronic engineering and I will like to work on board .
    What are the steps I to go through before getting a seagoing job

    • @leckyjake
      @leckyjake  Před 2 lety

      It actually depends on your country if you are asking about requirements

    • @yaswanthsri2524
      @yaswanthsri2524 Před 2 lety

      u can do course called ETO

  • @nelsonramirez7586
    @nelsonramirez7586 Před 2 lety +1

    Hello sir.. i just ask if you need to deactivate first or set some setting in the control to not activate the pressure switches while doing pump down??? Thank you in advance

    • @leckyjake
      @leckyjake  Před 2 lety

      good question, if the suction pressure switch is more than zero bar/MPa then adjust it to zero.

    • @nelsonramirez7586
      @nelsonramirez7586 Před 2 lety

      @@leckyjake Thank you sir.. God bless you always and takecare... one of your subscriber here 😊

  • @royceroneilramos
    @royceroneilramos Před rokem

    Ano po yung dahilan bakit need munang naka crack open lang ang service valve ng suction side sa compressor 2? Thank you idol 🙂

  • @ninogonzales4621
    @ninogonzales4621 Před 10 měsíci

    Sir leckyjake patulong naman yong fish room namin ayaw mag reach sa -18 ,hanggan-13 lang sya. Palaging nakabukas yong expansion valve kaya nag ice na yong evaporator. Kahit nag depros na kami ayaw pa din talaga tumaas . Patulong po. Salamat idol

  • @adepojuadewale1567
    @adepojuadewale1567 Před 14 dny

    please can u send this unit diagram

  • @asifraza1663
    @asifraza1663 Před 5 měsíci

    I want to join criuse line i have 5 year experience in Dubai can you help me

  • @kaden2985
    @kaden2985 Před rokem

    ρгό𝔪σŞm

  • @randygalang4994
    @randygalang4994 Před rokem

    Chinese ka sir?