CONTAINER REFRIGERATION TROUBLESHOOTING, COMMON TROUBLES IN STARCOOL REEFER

Sdílet
Vložit
  • čas přidán 30. 07. 2024
  • What are the common troubles you will be facing in a Starcool Reefer? Here are my most common troubles I always faced in this Starcool unit.
    #reefer #refrigeration #refrigerationcycle #refrigerationequipment #seafarer ##airconditioner #hvac #seaman #refrigerationandairconditioning

Komentáře • 67

  • @ChandanaPriyantha-pq3uv
    @ChandanaPriyantha-pq3uv Před měsícem

    Thank you sir lesson of trouble shooting of containers of reefers

  • @janettelanuiki
    @janettelanuiki Před 2 lety +2

    17 years here at the Port of Tacoma as a “reefer mechanic” real good to see /hear from “like minded individuals”

  • @corinthiansfrancis9408
    @corinthiansfrancis9408 Před 10 měsíci

    You're the most complete technician on yt love from Pakistan ❤

  • @ShipAhoyVlogs
    @ShipAhoyVlogs Před 2 lety

    Great videos. Keep vlogging. I am fan of electrical matters. Thank you!

  • @slicksloth3586
    @slicksloth3586 Před 2 lety +3

    love you lecky im glad i found your page this is awesome work, im a commercial air conditioning technician so i love watching your hvac/r related vids especially !

  • @sanjaykrishnakrishna-jr4bc

    Sir your great very helpful video new person and me also I am working in trailer reefer container thanks lot

  • @stephenshepherd6854
    @stephenshepherd6854 Před 2 lety +1

    You are so knowledgeable and intelligent. Wish I was someone like you. Too old now. Did work onshore ships when I was young. The Jealousy 😆

    • @leckyjake
      @leckyjake  Před 2 lety

      thank you for your wonderful comment

  • @megabibidanuni2339
    @megabibidanuni2339 Před 2 lety +2

    I’ve had evap motors where they forget to install a spacer washer for the fan blade. Most common problems I see with starcool are the contactors coming off the rail and interlocks missing. 👌

  • @ozzynichols5026
    @ozzynichols5026 Před 2 lety

    Thank you. I ran out of spare Starcool evaporator fan motors on my last ship and I was wondering about how to run them with just one fan.

  • @aungkowinkyi8549
    @aungkowinkyi8549 Před rokem

    Thanks you very much indeed.

  • @pedrojardim1163
    @pedrojardim1163 Před rokem

    We had a few containers the place I use to work
    But troubleshooting it's was little confusing for mi
    Especial on the control board
    The u doing makes life easier

  • @alexandrodey4174
    @alexandrodey4174 Před 2 lety

    Thank you so much sir, i'm ETO from indonesia

  • @tomdary1993
    @tomdary1993 Před 2 lety +4

    I sailed once as an assistant electrician aboard a container ship. I was surprised at the number of containers that fail while in transit. They came to the ship limping on their last leg only to die aboard the ship. Not too clear on how the ship compensated for spare parts. I was told that it costs the ship too much to have spare parts at the ready, so we didn't have many. Contactors seem to be a common repair too.

  • @rb1m426
    @rb1m426 Před 2 lety

    Mr. Secretary isa kang henyo ☺

  • @Kishore.96
    @Kishore.96 Před rokem

    Love from India ❤

  • @JoelectricalTV
    @JoelectricalTV Před rokem

    Sana po magkaroon din kayo ng vlog about CA reefers. Godbless sir leckyjake.

  • @vinaymaddu7567
    @vinaymaddu7567 Před rokem

    Hai sir Nice information for us if u don’t mind Will you please Tell the using of reefer tools names please sir

  • @abdoubouz8951
    @abdoubouz8951 Před 2 lety

    In most cases you can reconnect the evaporator motor after it has cooled down and it will work fine (if it is not defective of course).

    • @walters24051
      @walters24051 Před 9 měsíci

      so just disconnect and give it 15 mins or so to cool down and it should be ok if not defective?

  • @osmankaya9664
    @osmankaya9664 Před 2 lety

    👍👍👍

  • @ratheeshkumar7765
    @ratheeshkumar7765 Před 2 lety

    Liquid sight glass is full SMV is good when temperatures reach - 10 and then going up and compressor keeps running

  • @trone32
    @trone32 Před 2 lety +1

    Hi Jake another great Video. Can you tell me what would have happened if the second motor had also failed, as you would not have access to repair due to the beam being across the access panels

    • @leckyjake
      @leckyjake  Před 2 lety

      either we discharge the unit on the next port (if sched is just near) or need to cut the beam as our main goal is zero damage cargo. this is the commitment for the customers

    • @trone32
      @trone32 Před 2 lety

      @@leckyjake wow cutting the beam is drastic but I can understand.

  • @r.4169
    @r.4169 Před rokem

    💯

  • @Bruisermac13
    @Bruisermac13 Před 2 lety +1

    You could have just jumped 25/26 at the main controller connector. And because the product temp is already at temp there’s no reason to block any airflow. If anything blocking the airflow will cause low suction pressure readings. The controller will get confused and Then the EEV will overfeed and possible slug your compressor.

    • @leckyjake
      @leckyjake  Před 2 lety +2

      If you will not remove the connections in the motor then once contactor activates you are still supplying the bad moto4 with 440Volts with the protection bypassed in the controller., that would be unsafe.

    • @Bruisermac13
      @Bruisermac13 Před 2 lety +1

      @@leckyjake agreed you have to disconnect the motor connection. But it’s easier to jump out the controller imo. I’ve fixed hundreds of these issues once they get unloaded off the ship. I have alot of respect for you guys at sea. No repair parts or training. These vids are great. I’m a CTC/ Daikin /SC/TK factory trained tech of 25 years. If your even at the Port of Vancouver hit me up!

    • @joebagadonuts-j4y
      @joebagadonuts-j4y Před 9 měsíci

      hi aaron. i need a little reefer help. would you be willing to spare me a few minutes? thanks

  • @arnelcolinares130
    @arnelcolinares130 Před 3 měsíci

    Sir me topic po ba kayo pano mdaling masusundan electrical diagram of carrier multi temp unit transport reefer po

  • @robertagomo-o-ly4uo
    @robertagomo-o-ly4uo Před rokem

    Kaya ako pag ganyan ang trouble, ina isolate ko nalang ang evaporator motor na may problema. Bypass mo lang yung connection sa controller at disconnect connection sa evap motor tapos lagyan lang ng cardboard ang sa fan blade para ma avoid ang short cycle.

  • @harishsingh9961
    @harishsingh9961 Před 11 měsíci

    Iam hvac/reefer container technician sir need to more information about reefer container

  • @r.4169
    @r.4169 Před rokem

    👍🏽

  • @rb1m426
    @rb1m426 Před 2 lety

    Mr. Secretary PLC naman for instrumentation

  • @ashoribaroka2768
    @ashoribaroka2768 Před rokem

    I have done what you did, but still my container is not running?

  • @mahboobKhan-uy7sm
    @mahboobKhan-uy7sm Před 7 měsíci

    ❤❤❤❤❤❤❤❤❤❤

  • @michaelerestain4634
    @michaelerestain4634 Před rokem

    Mayi know if they have a tagging No. Of wire ,because all wire is black,may i know if they Numbering wire from 1 to 8 and Ground,Thank you And Godbless

  • @rudrabahadurthapa9631

    How to fix the fuel pump problem in mtrcs

  • @HappyFlowerBouquet-tu9on

    Please kindly help ran refrigerated containers yard facility in inland Boankra port in Ghana

  • @emmaa427
    @emmaa427 Před 2 lety +2

    Does the refrigerated container have its own power supply or is it connected to the ship's electrical grid ?

    • @leckyjake
      @leckyjake  Před 2 lety +1

      they are connected to the ship's Switchboard

  • @ratheeshkumar7765
    @ratheeshkumar7765 Před 2 lety

    I have a problem in my carrier Transicold cotatainer not reaching temperature set point is - 20 there is no alarm pressure high is 200 psi low is 5 psi temp coming up to - 10 only do you have any solution

    • @leckyjake
      @leckyjake  Před 2 lety +1

      Is the - 10 the supply or the return

  • @garryboy4941
    @garryboy4941 Před 2 lety +1

    Shout out lecky

  • @navadaspencer7252
    @navadaspencer7252 Před 2 lety

    Hi I am having a problem with my carrier unit I have alarm codes from one to 16 and the compressor won’t come in everything else work but the compressor won’t come in

    • @leckyjake
      @leckyjake  Před 2 lety

      Check the terminal connections on your controller

  • @lanceevans7356
    @lanceevans7356 Před rokem

    I've got a problem with a reefer container carrier thinline transicold model # 69NT40-541-008. It is showing these alarm (AL52)&when display the alarm stack its show(AL01,AL02,AL03..TO AL16)and these alarm codes not found in manual How can I solve that

    • @lanceevans7356
      @lanceevans7356 Před rokem +1

      Any assistance would be greatly appreciated thanks.

    • @leckyjake
      @leckyjake  Před rokem

      first check your terminal connections in your controller. if you have batches of alarms most probably you have a loose connections in your controller

    • @lanceevans7356
      @lanceevans7356 Před rokem

      @@leckyjake they are all gud

  • @rinak5932
    @rinak5932 Před 2 lety +1

    Kuya Lecky...what might have caused F.C. to go kaput? Would fixing the contactor/auxillary/interlock/circuit breaker/r&r access panel affecting the FC?

    • @leckyjake
      @leckyjake  Před 2 lety

      there are a lot of reasons why the FC will get faulty but in general it is just because it is a running machinery that reached its limit

    • @rinak5932
      @rinak5932 Před 2 lety

      I see...thanks Kuya Lecky

  • @llunardflorida597
    @llunardflorida597 Před 2 lety

    Boss

  • @propesyonalstambay2613
    @propesyonalstambay2613 Před rokem +1

    sir ano po mdalas sanhi pag nag titrip ang breaker? thermoking po

    • @leckyjake
      @leckyjake  Před rokem

      short circuit or overloading. tingnan mo kung anong component ang nag ON bago mag trip, like if compressor ba, condenser motor, evap or immediately nag ttrip nasa cabling

    • @propesyonalstambay2613
      @propesyonalstambay2613 Před rokem

      @@leckyjake mraming slamat po sir jake

  • @ratheeshkumar7765
    @ratheeshkumar7765 Před 2 lety

    Return

  • @hasnaendaila5244
    @hasnaendaila5244 Před rokem

    Sir magtagalog ka nalang po medyo di rin masyado clear kapag sa english po. salamat sir

  • @rinak5932
    @rinak5932 Před 2 lety

    Kuya Lecky....how can i reach u via email? I have tons of questions regarding reefer mechanical...daikin n starcool always gives me problems *sigh*

  • @user-sl5js8rw7j
    @user-sl5js8rw7j Před rokem

    Lecky I have a carrier reefer container 69nt40 511 309 Evap motor number 2 overheat. What causes the Evap motor to overheat.