What a TXV Does (and why techs need to stop replacing them with a piston)

Sdílet
Vložit
  • čas přidán 12. 02. 2021
  • Why techs need to stop replacing them with a piston? What a TXV Does? Craig from AC Service tech joins us and shares some of his knowledge on thermal expansion valves and shares his concern about techs replacing a TXV with a piston.
    Visit AC Service Tech website at: www.acservicetech.com/
    Find Craig's channel here: @acservicetech
    Read all the tech tips, take the quizzes
    and find our handy calculators at www.hvacrschool.com

Komentáře • 317

  • @wiggie8860
    @wiggie8860 Před 3 lety +62

    It’s awesome to see the only two HVAC channels I watch collaborate and really helps to trust the information on either one

  • @acservicetechchannel
    @acservicetechchannel Před 3 lety +54

    I had a ton of fun teaching and joking with Bryan! Thanks for inviting me down for the collab!

    • @MaMa-qh4dy
      @MaMa-qh4dy Před 3 lety +1

      Craig, it is so obvious that you totally enjoy what you are doing. Congrats!!!!

    • @megalomani4k
      @megalomani4k Před 3 lety

      Great info for a newbie tech

    • @Livingcomfortinc
      @Livingcomfortinc Před 2 lety

      Ac service tech is still my favourite channel out there ! 100%

    • @jashua2089
      @jashua2089 Před 2 lety

      Thank you for everything, we love your channel and Bryans.

  • @TonyWadkins
    @TonyWadkins Před 3 lety +6

    Without a doubt these two guys are changing the course of modern HVACR technician quality learning & development and away from old school beer can troubleshooting and repair.

  • @mehdibourha180
    @mehdibourha180 Před 3 lety +10

    Top 2 guys in the HVAC industry i learned a lot from you thank you for everything
    RESPECT

  • @seroxide
    @seroxide Před 3 lety +71

    I see bad TXV's all the time here in Texas. I've yet to find a bad piston.

    • @agx012
      @agx012 Před 3 lety +19

      Say it louder for the people taking notes

    • @gregorymalchuk272
      @gregorymalchuk272 Před 3 lety +5

      How does the reliability of the electronic expansion valve compare to thermal bulb expansion valves? It seems to me that the mechanical advantage of a stepper motor screwing the expansion valve in and out would be a lot better and more reliable (less likely to jamb) than a thermal expansion valve using refrigerant bulb to push the valve.

    • @redneckrebuilds777
      @redneckrebuilds777 Před 3 lety +9

      @@gregorymalchuk272
      EEVs break a lot. Better have a spare at the store. Also failed EEVs will burn up the control board and can send crazy voltage on your com.

    • @MrGarcon98
      @MrGarcon98 Před 3 lety +1

      you said it buddy ,,,,right on

    • @Jakeofalltrades777
      @Jakeofalltrades777 Před 3 lety +6

      You’re not lying bro, replaced my first clogged piston a couple days ago, I been doing hvac in Texas for a few years. I have replaced multiple TXV’s.

  • @SKaKies2228
    @SKaKies2228 Před 3 lety +4

    Love this! When I started in this trade I watched all of acservicethech’s videos and hvacr school’s videos. Really enjoyed this collaboration between you guys!

  • @timrob0420
    @timrob0420 Před 3 lety +13

    Go tell John Israel that he has a whole video on why he thinks pistons are better. You guys rock

    • @lordjaashin
      @lordjaashin Před 3 lety +1

      this isn't the video about which is better? txv or piston?? this video is about why shouldn't change a TXV system to piston.

    • @timrob0420
      @timrob0420 Před 3 lety

      @@lordjaashin isn’t that the same thing? John Israel was converting failed txv evaporators to pistons. I’m not knocking on him either, I have mad respect for him too. Just saying.

    • @lordjaashin
      @lordjaashin Před 3 lety

      @@timrob0420 if he's changing TXV based systems to piston based system then he shouldn't be doing it

    • @timrob0420
      @timrob0420 Před 3 lety

      @@lordjaashin I agree with that unless I’d customer is in a bind money wise.

    • @MrGarcon98
      @MrGarcon98 Před 2 lety +1

      @@timrob0420 the less moving parts the less the problems period i am 67 retired back in millwright aprentice school we where told that very early and now that i turned wrenches ,welded and did all the above i would agree with you for that reason ,,,,stay safe people

  • @williamgildea8348
    @williamgildea8348 Před 3 lety +2

    Wow, you guys make a great teaching team. Great training video. Thank you , looking forward to seeing more in the future.

  • @acrepairnearme
    @acrepairnearme Před 3 lety +5

    Great, great collaboration. Properly!

  • @bravoactual5807
    @bravoactual5807 Před 3 lety +1

    Currently in HVAC school right now and this channel has been an excellent resource for me. Thank you for making these videos.

  • @coldfinger459sub0
    @coldfinger459sub0 Před 3 lety +1

    Two of HVAC’s greatest educating mine combined to bring even more to our industry in higher education.
    I’ve always wanted to be an HVAC instructor College trade schools when I retire.
    By the time I get there you make my job easy I just have to refer to your videos and your books that you produce and just guide and instruct. Your content is so thorough and broad spectrum covering in detailed I cannot possibly do better. 👍👍👍

  • @mitchellbarnow1709
    @mitchellbarnow1709 Před 2 lety

    Craig is awesome 👏! Thank you so much for sharing him on your channel.

  • @Aevodude
    @Aevodude Před rokem +3

    The reason I intend to replace my txt with a piston is the inherent low mtbf txvs have - pistons may be a little less efficient but they rarely if ever fail and that is far more comforting period

  • @isaiahsgametube2321
    @isaiahsgametube2321 Před 2 lety

    both of you guys are amazing, learned alot from you both. KNOWLEDGE IS POWER

  • @gonzalomadero9848
    @gonzalomadero9848 Před 3 lety

    Greatest crossover so far this year!!

  • @resurgensix
    @resurgensix Před 3 lety

    Love to learn from SoCool Wizards. You guys are a great team. Thanks for all your mentoring.

  • @eduardoacosta2315
    @eduardoacosta2315 Před 3 lety

    Thank you so much 2 Masters HV-AC SOLUTIONS 🙏
    God bless you all Thank you again and for your Video

  • @Stuart68505
    @Stuart68505 Před 3 lety

    Many helpful techniques and explanations. Thank you.

  • @ericharrison7545
    @ericharrison7545 Před 3 lety

    The only two channels I trust. Awesome !!!

  • @jashua2089
    @jashua2089 Před 2 lety +1

    Two masters together :D best video ever, please make more like this.

  • @johnjonz2472
    @johnjonz2472 Před 3 lety +2

    First Bosnian Bill with The Lock Picking Lawyer. Now this. Awesome!

  • @SSS-xq1lg
    @SSS-xq1lg Před 4 měsíci

    Working together is fantastic; two heads are better than one. Among the finest

  • @phillipjoy8191
    @phillipjoy8191 Před 3 lety

    You got to love these 2 guys.Great videos 😜

  • @Gameboy_Steve
    @Gameboy_Steve Před 3 lety

    Awesome video thanks again. Will share with the new guys at the shop

  • @renecuevas4128
    @renecuevas4128 Před 2 lety

    Great svc to our industry....well explain by both of you....tnk u 👦

  • @u2ooberboober
    @u2ooberboober Před 3 lety

    Great team up!

  • @ssb2865
    @ssb2865 Před 9 měsíci

    Very nice. Learned a few key things. Thank you guys.

  • @mohamedroomy1985
    @mohamedroomy1985 Před rokem

    It's great lesson. Very informative. Thank you sir

  • @paulrozinski1488
    @paulrozinski1488 Před 3 lety

    Another fine / informative joint video. 👍. Thanks guys .

  • @superd0fad0
    @superd0fad0 Před 3 lety +5

    Encouraging to see that 2 AC masters instead of competing to see who is better than the other. They are pooling their knowledge to help others.

  • @shine-cg9uf
    @shine-cg9uf Před 3 lety

    Great video and very informative 👍. Thankyou n keep sharing knowledge much appreciated 👍

  • @josephpuchel6497
    @josephpuchel6497 Před 2 lety

    Hello Your videos are very nicely structured tutorial A Plus rating. Im new at HVAC. Even though I diagnose home issues Im looking into installing a TXV into vehicles. Im experimenting right now It’s more a hobby.

  • @sergiodjf
    @sergiodjf Před 3 lety +2

    Great video! The explanation couldn’t be better 💯👏. Since the contact area between the TXV sensing bulb & coil outlet line is not optimal (because both are round-shaped), I think adding thermal paste could improve heat transfer for better temperature sensing. Kind of what happens with temp sensor probes & thermowells.

  • @edgar20109
    @edgar20109 Před 3 lety

    Great video!!! Thanks for teaching

  • @NorCal-refrigeration
    @NorCal-refrigeration Před 3 lety +9

    Refrigeration guys know TXV is way better than a piston or cap tube.
    Great video, Craig dose an awesome job.

    • @newkidontheblockism
      @newkidontheblockism Před 2 lety

      For refrigeration yes, for residential AC it’s not necessary. I’ve done both for 15 years

    • @NorCal-refrigeration
      @NorCal-refrigeration Před 2 lety

      @@newkidontheblockism agree as far as ease of use and less breakdown. But the TXV is there for efficiency ratings. Going green and no longer making enough electricity ⚡️ has utilities scrambling to get the overall load on the grid lower. We are devolving as a nation on stuff that used to be basically available to everyone.

    • @newkidontheblockism
      @newkidontheblockism Před 2 lety

      @@NorCal-refrigeration funny, I was reading your comment thinking this guy must be from California then I read you name 😁

    • @NorCal-refrigeration
      @NorCal-refrigeration Před 2 lety

      @@newkidontheblockism yep

    • @newkidontheblockism
      @newkidontheblockism Před 2 lety +1

      I personally present it to my customers like this, “are you concerned with efficiency because you want a greener earth or do you want to save money?” If money is there concern, which it almost always is, then I let them know it’s more economical to purchase a base line model which will cool your house the same and have fewer repairs because the little bit of money you may save over the lifetime of your AC will be whipped out and then some by the cost of repairs.

  • @armandorodriguez6447
    @armandorodriguez6447 Před 2 lety

    Very seldom do I get an opportunity to listen to Two of the most knowledgeable HVAC instructor. Thank you

  • @williamfabiano543
    @williamfabiano543 Před 3 lety

    Thanks for the knowledge

  • @glorygloryhallelujah
    @glorygloryhallelujah Před 3 lety

    Great lesson.

  • @v65sabreking
    @v65sabreking Před 3 lety

    Awesome job guys ..

  • @DisEnchantedPersons
    @DisEnchantedPersons Před 3 lety +1

    Well done !!

  • @mattluongo7763
    @mattluongo7763 Před 2 lety

    I've done it multiple ways. Replaced TXVs with pistons and vsversa. All comes down to the situation. I've also cleaned clogged strianers when other techs condemned the valve.

  • @scottbarnett5729
    @scottbarnett5729 Před 3 lety +5

    pistons save service calls he just said it when a txv fails when did you see the last piston fail?

    • @zack9912000
      @zack9912000 Před 3 lety +2

      agrees love pistons. Never had one fail, had new TXVs be bad out of the box or system oils react with seals in a txv killing them.

  • @kennethnapier131
    @kennethnapier131 Před 2 lety +1

    I had a customer that had a 16-seer 2-stage split system that I was called to for poor cooling. It was a 5-ton system and one of the past service company removed the TXV and put in a piston. And still without using the science of refrigeration the root problem had not been found. When this house was built, the system was somehow contaminated; likely no nitrogen used when braising. I determined the filter/dryer inside the condensing unit was plugged with an 8-degree temperature drop. I removed the filter in the condenser, and installed a new filter dryer at evaporator, installed a new TXV, recharged and tuned the system. The customer was extremely thankful since this was the first time since they owned the house to be able to keep it comfortably cool.

    • @ericvelasquez1282
      @ericvelasquez1282 Před 10 měsíci

      Is this novel all about how you are such a super-duper AC tech?

  • @user-nc9nz2om4m
    @user-nc9nz2om4m Před 3 měsíci

    Good info from 2 knowledge techs.

  • @ed6837
    @ed6837 Před 3 lety

    Excellent video

  • @donnierobertson3088
    @donnierobertson3088 Před 2 lety

    Great job and video like always

  • @brianmcdermott1718
    @brianmcdermott1718 Před 3 lety

    Great tech. Tips. Thanks .

  • @ying0129
    @ying0129 Před 3 lety

    Hey brother!
    Thank you!

  • @b-2466
    @b-2466 Před 3 lety +2

    These are the two best hvac channels together in one. Love to know what these two do.

  • @ed6837
    @ed6837 Před 3 lety

    Patching a small tube we used to put a piece of 1/4" OD over the tubing your patching male the 1/4" tubing long enough to staw away from the open ends. Heat the 1/4" on both ends and pinch it down and braze the ends

  • @nolannsautodetail5468
    @nolannsautodetail5468 Před 3 lety

    Thank you so much for these great videos. Would love to see a video on how to install a un light hardwire. It correctly , thank you in advance

  • @garikharutyunyan163
    @garikharutyunyan163 Před 3 lety

    Thanks Guys

  • @Stuart68505
    @Stuart68505 Před 3 lety +6

    Re: the sensing bulb & proper heat transfer - in electronic applications they had & may still use a white paste to ensure good heat transfer between a metal enclosed semi conductor device like a power transistor and a heat sink device.
    That type of paste could help transfer heat from the copper tubing to the txv’s sensing bulb body.

    • @tmst2199
      @tmst2199 Před 3 lety

      You could see a bunch of light between the bulb and the line in this video. I wondered if that was considered acceptable.

  • @ryanbrown5334
    @ryanbrown5334 Před rokem +1

    TXVs help prevent refrigerant migration and flooding of the compressor when the system is off because of hard shut off and pressures not equalizing. This is why a hard start is recommended with TXVs especially in long line applications.

    • @rodgraff1782
      @rodgraff1782 Před rokem

      Exactly. Three phase systems do not require the hard start kit though. Proper refrigerant control on the off cycle has saved many a compressor from flooded starts.

    • @georgekolos5255
      @georgekolos5255 Před 10 měsíci

      Very true, but does not explain how many non TXV systems are still operating that have surpassed 40 years of doing already and are still going strong even through 100 degree days

  • @scottkasper6378
    @scottkasper6378 Před 3 lety +1

    Great video! The other thing that makes Txv superior to a piston is that it can open more during hot conditions to let in more refrigerant than a fixed orifice could.

  • @dcl97
    @dcl97 Před 3 lety +7

    The problem I have with them is that their theoretical effeciency improvements don't line up with reality. I replaced the TXV in my own system with a piston, and comparing before and after runtime data on days of the same temperature I'm seeing a 2-5 percent loss in efficiency. Considering what I spend on cooling here in southern Michigan that's $15 a year. One service call on a TXV and any cost savings it gives the customer over the life of the equipment is gone. Not worth it. Now if I was in Florida or Arizona and I'm running my ac all day, all year I could see the advantage, but for people in the Northeast, Midwest... doesn't make sense.

    • @consaka1
      @consaka1 Před 2 lety

      I didn't see them give any efficiency specs comparing the two. I'll have to go back and watch again.

    • @cantor7723
      @cantor7723 Před rokem +1

      @@consaka1 That's the main point of them. Old systems from like the 90's had pistons. TXVs provide greater efficiency by controlling the flow of refrigerant. No doubt replacing a TXV with a piston uses more power, but in a low cooling area, the difference is minimal. For older clients on a fixed budget who normally get cold anyway, I recommend throwing in a piston instead of a txv replacement. It's cheaper to replace with a piston and more reliable. Sure it will use more power, but they don't use the AC much anyway - some keep the AC on 78 degrees.

  • @tntheatingandairllc
    @tntheatingandairllc Před 3 lety

    Awesome video guy’s 👍👍

    • @henrybonilla9651
      @henrybonilla9651 Před 3 lety

      Nice video
      Question
      About to make a hole on a refrigerant line.
      If I put nitrogen 50 psi and then drill a hole
      Will push out all the copper debris?
      Wearing PPE.

  • @jamesbianchini4718
    @jamesbianchini4718 Před 3 lety +1

    This is awesome. I have been watching you 2 for some years keep it up. 💯

  • @jashua2089
    @jashua2089 Před 2 lety

    Thanks!

  • @PaulHVAC1
    @PaulHVAC1 Před 2 lety

    Excellent

  • @DM-kb3bi
    @DM-kb3bi Před 3 lety

    WOW 2 Juggernauts of the Rap, i mean Hvac game! Love to see this collab. Very nice. I follow 2 of u guys.
    Nice man!

  • @dysfunctionalgamingveteran7753

    I normally do not replace a TXV with a piston. One of the few time was when I had 3 brand new TXV fail after replacing a evap coil. It was late and the supply house was closes.

    • @haroldbottom3474
      @haroldbottom3474 Před 2 lety

      Three brand new that failed TXVs or improper brazing methods.

  • @edwinjewell5359
    @edwinjewell5359 Před 3 lety

    2 Great Havac Techs

  • @stan-r
    @stan-r Před rokem

    Hi, I maintain over 100 Rheem package units at our resort. The other day, I responded to a call where water was leaking into the ceiling. When I arrived, the evaporator coil and compressor were covered in ice.
    There is a lot of debate around the shop as to why this happened. Airflow was okay. The coil was clean and after thawing everything out, the blower motor didn’t have any problems pulling the filter panel closed on it’s own.
    Some of the technicians believe that the doors to the room below were the cause because they were open to the4 hallway, even though the hallway was being cooled by another package unit.
    The high side gauge was only about 10 degrees above ambient (104 / 115), and the low side gauge was around 42 degrees. I’m accustom to seeing the high side gauge around 30 degrees above ambient. The compressor was pulling 15amps on all three legs and the condenser coil was clean.
    I moved the TXV bulb outside the unit, and nothing changed with the low side press/temp which made me pause. Adding refrigerant didn't change anything either. There was 6 degrees superheat and almost 0 degrees of sub cooling, but package units are difficult to make accurate measurements because all the components are tucked away in the cabinet.
    I think something is wrong with the TXV, but I don't know how to make a positive diagnosis with a package unit. The other technicians believe, that the coil can still freeze even with 75 degree air is flowing through it. Any thoughts?

  • @Holler_Rat
    @Holler_Rat Před rokem +1

    Installed a new "Premium" packaged unit one year ago. Replaced the indoor txv today due to it failing. They're junk. I'd take a piston any day of the week.

  • @MJ-iy4fb
    @MJ-iy4fb Před 2 lety

    Good video, Brian you have a great voice for this stuff. I am a little confused, your title say "and why techs need to stop replacing them with a piston" but at 15-18 sec you said "and why you may not want to replace a piston with a TXV" did I miss something in the video or was that a mistake?

  • @forcebewhithyou94
    @forcebewhithyou94 Před 10 měsíci

    very good

  • @user-hz6qp1it2n
    @user-hz6qp1it2n Před 10 měsíci +1

    Got a 4 ton system installed in my home this year in the Dallas, Tx area. Told the tech, don't even think about installing an evap coil with txv. When it's 106 degrees outside like it is today, I don't give a rats ass about efficiency.

  • @wilfredovega577
    @wilfredovega577 Před 2 lety

    Thank you. Question? What is the allowable temperature drop across the inlet of txv and the outlet of it

  • @charlesjackson9602
    @charlesjackson9602 Před rokem

    I use to replace TXV...with pistons all the time.....realiabity more important that effciency.....and you will probably have to replace a TXV...in 10 years....and just one change...will pay what little bit of energy saving you get with a TXV...salute to Goodman...for trying to keep Pistons in majority of there units...

    • @georgekolos5255
      @georgekolos5255 Před 10 měsíci

      Government is making TXVs mandatory on all new AC systems :(

    • @charlesjackson9602
      @charlesjackson9602 Před 10 měsíci

      @@georgekolos5255 Show me where its required to have a TXV...

  • @jbaker8871
    @jbaker8871 Před 2 lety

    Never heard of this problem. Only complaint i have is difficulty finding amount of superheat required. 10° when in doubt has served well.

  • @rodgraff1782
    @rodgraff1782 Před rokem

    You also have a pressure drop in that line set, which is different than the pressure at the TXV bulb. To measure superheat accurately, there should be a tap at the bulb location, and the pressure and temperature should be taken there. That is what the valve is seeing. Bulb should never be mounted at the bottom of the pipe. Temperature will be affected by oil. Great video.

    • @georgekolos5255
      @georgekolos5255 Před 10 měsíci

      Add in allowance for depending where your checking superheat on system

  • @GonzoDonzo
    @GonzoDonzo Před 2 lety

    Im in california and in 17 years i only replaced a handful of txv's. Most times it wasnt installed properly and i just had to strap them in the proper position.

  • @seroxide
    @seroxide Před 2 lety +1

    Don't get me wrong. I understand that a correctly working TXV is better than a piston. My problem is I see a lot of TXV's that are poorly performing but not bad enough to justify the cost of replacing. A few years ago I went to a rent house with a 4 year old Payne unit with electric heat. It was a insufficient cooling call. Had high subcooling and superheat. I replaced the TXV after driving across town and waiting in line at the Carrier dealer. About 6 months later I get a insufficient cooling call from the property owner. Same condition as before. Replaced TXV under warranty this time I eat the labor, etc. Less than a year later, same damn thing. This time it got a piston conversion and I haven't been back since. Now when I replace a TXV I make it abundantly clear that the labor warranty last until my tire makes the first revolution. I always flow nitrogen when brazing and use good a evacuation process.

    • @rodgraff1782
      @rodgraff1782 Před rokem

      I would not blame that on TXVs in general. Must have been a design problem with the valves, or you just had plain bad luck. It wasn’t your fault. I always used Sporlan or Alco valves, and never had a repeat problem in 45 years. Maybe you were using valves that were sold domestically, but were made in China.

  • @isaiahsgametube2321
    @isaiahsgametube2321 Před 2 lety

    the dream team on deck

  • @joshuawolfer9903
    @joshuawolfer9903 Před 3 lety +1

    Good explanation. One thing not mentioned, almost all systems are rated with a txv. If someone tries to cover poor install practices by installing a piston then the system isn't even rated and won't perform as intended. I've never had an issue with a txv on a system I installed. I have seen a 5 ton unit only provide 4 tons of cooling with a piston instead of a txv. Installers swapped it out instead of the factory installed txv. They are there on purpose. Thanks for the content.

    • @tmst2199
      @tmst2199 Před 3 lety

      Good man.

    • @consaka1
      @consaka1 Před 2 lety +1

      I'm guessing they used the wrong size. That's a very big difference.

    • @rodgraff1782
      @rodgraff1782 Před rokem

      @@consaka1 A piston is no better than a capillary tube. It’s OK for systems that run at a fixed heat load. They can’t maintain superheat, or meter the proper amount of refrigerant according to the heat load. That’s the reason they are called a fixed restriction refrigerant control.

  • @TheFoxygrandpa69
    @TheFoxygrandpa69 Před 11 měsíci

    Most guys i know swap to piston cuz its "easier", and charge the same price as a txv repair. But ive seen undersized pistons get installed and single sided pistons get put on heat pumps. Just replace the TXV. Its super easy, less trouble, and if the system is 10yrs or older you'll know it wasn't debris clogging it. So the new one should last.

  • @toddhollman5674
    @toddhollman5674 Před rokem

    LL driers should be installed just in front of the metering device anyway, per manufacturers instructions. Part of the job of the dryer is filtration to protect the TXV and is you install it out at the condenser you have all that line before the metering device.

  • @djchefw3553
    @djchefw3553 Před 3 lety

    Wow what a crossover episode

  • @georgekolos5255
    @georgekolos5255 Před 10 měsíci +1

    Regarding TXV bulb mountings. Put the little tailpiece so that any liquid refrigerant that may be in the buld doesn't settle in the little tailpiece section/ bend it upwards/ don't mount bulb vertically with that little tailpiece on the bottom??
    At least I always am mindful about such

  • @ezchoicelab9904
    @ezchoicelab9904 Před 3 lety +7

    Do you think it might be a good idea to use thermal paste on bulb. To make sure it transfers heat.

    • @tmst2199
      @tmst2199 Před 3 lety +1

      Yeah. Did you check out all the light coming through that interface?

    • @consaka1
      @consaka1 Před 2 lety

      That's what I was thinking. Honestly surprised that's not a standard practice.

  • @ericharrison7545
    @ericharrison7545 Před 3 lety

    Love the callab.

  • @grantbrown2432
    @grantbrown2432 Před 2 lety

    Pistons never fail but TXV‘s or more soothing to the system

  • @monroekunz2070
    @monroekunz2070 Před 2 lety +1

    Had 1 txv fail that I put in, in 40 years but have seen installers from different companies purge lines with freon and not use vac pump when installing new equipment.

    • @consaka1
      @consaka1 Před 2 lety

      They need to get in a different line of work where there sloppiness and lack of detail doesn't end up screwing over the customer.

    • @monroekunz2070
      @monroekunz2070 Před 2 lety

      @@consaka1 you know when you find a 8 year old compressor with a hole rotted through the can. It was never pumped down. Builder model in new construction at time of manufacture had 5 year parts warranty. Instslled by one of the largest company's in area.

  • @donjohnson5172
    @donjohnson5172 Před 2 lety

    I’ve heard so many guys argue about the part at 10:00 where you say the tail needs to be mounted up in a vertical position. Why is that? What does it do?

  • @u2ooberboober
    @u2ooberboober Před 9 měsíci

    Could some sort of heat sink grease be use at the sensing bulb interface to promote better heat sensing?

  • @Pennconst101
    @Pennconst101 Před 2 lety

    General question. What issues if any would be created the TXV installed upside down?

  • @supanovahpodcast3511
    @supanovahpodcast3511 Před 2 lety

    y'all the best

  • @billbowles2380
    @billbowles2380 Před 3 lety

    Another argument against zip tie is that they won't conduct. Although minuscule a metal/copper clamp will help conduct temp into the txv bulb

  • @sheldonlionel8694
    @sheldonlionel8694 Před 2 lety

    I have seen the txv bulb mounted outside of the handler. Is that recommended?

  • @adamspears3819
    @adamspears3819 Před 3 lety

    When you say "CW" & "CCW" is that looking directly at the bottom of the TXV....or is that looking down at the head of the TXV?

  • @jascam1
    @jascam1 Před 2 lety

    My newly installed Gman 3.5 H/P sweats on the A/H housing and a lot of water pool under the condenser. The tech replaced my TXV with piston in the attempt to rectify. The H/P works fine otherwise, what's with the extra water??

  • @andreeriner811
    @andreeriner811 Před 2 lety +2

    I have to tell these guys I get what they are saying, but I’ve been know to use a piston in place of a junk txv. As long as you use the rite piston and the system is working within peramiters it’s fine to do that. I don’t do this on newer systems, in a pinch I’ve done it on old systems that it really didn’t matter especially when you have a customer who is cheap. I carry all sizes of pistons,

  • @jimbola77
    @jimbola77 Před 3 lety

    man Craig bleeds a/c!!!! he is awesome!!!!.

  • @Xaerorazor0
    @Xaerorazor0 Před 2 lety

    Just happened by your channel (Thanks YT), I have a question in RE to the Bulb not making the best contact, would a thermal grease/patch, like what is used on CPU heat sinks, be a way to better improve contact between less than straight surfaces?

    • @Kevin-ib4gv
      @Kevin-ib4gv Před 2 lety

      Personally I would not use it. It could eventually dry out and cause some type of insulation between the two. Scotch Brite both bulb and suction line completely clean and shiny, and mount the bulb at 11:00 or 2:00 position or whatever the TXV manufacturer recommends and you're good to go.

  • @boywhohadatiger
    @boywhohadatiger Před rokem

    Why does daikan/Goodman/Amana recommend adjusting the superheat? I think it’s odd I only see that you should adjust them for those units. But I’ve never adjusted one to see what would happen. And I’d that can fix a problem with the txv

  • @thealeons3179
    @thealeons3179 Před 2 lety

    Does anyone know of a electronic expansion valve where the controller will allow you to run the suction pressure into a vacuum without faulting? Also the Sporlan controller I was using would fault out below -59F. I had to run the controller in manual mode so it wouldn't fault out then I had excellent control metering the refrigerant into the evaporator. At -85 degrees I can be running a suction pressure 25 in of Mercury. Single stage ultra low temperature chiller with subcooler

  • @mikefreedom5612
    @mikefreedom5612 Před 3 lety +1

    TXV is simply superheat controller device + expansion metering device at the same time

  • @uncleb9294
    @uncleb9294 Před 3 lety

    🔥🔥

  • @SovereignTroll
    @SovereignTroll Před 3 lety +2

    The industry doesn't braze with N2, a reality many places. I saw it. Pistons are less sensitive so... Now I use N2 but I am sent to do electrical, too slow in others opinion.