Full Off Grid install 6kw Inverter and 15kw Battery - Big Battery Rhino 2

Sdílet
Vložit
  • čas přidán 1. 08. 2024
  • The Rhino 2 Big Battery is great for use as an off grid power system in my shop. This install has a 15kwh lifepo4 self heating battery with 6000w pure sine wave inverter. A small shop like the one I have can run from this system with ease. 2000w of solar power feeds this system so that it can stay off grid.
    bigbattery.com/?ref=273
    Buy a Ram Pump at the Land To House Store:
    landtohousestore.com/
    Ram Pumps available on AMAZON
    amzn.to/2EWrQHN
    Help Support land To House by Paypal:
    paypal.me/landtohouse
    Send Mail to Land To House:
    Land To House llc
    P.O. Box 323
    Micaville, NC 28755
    See whats coming up before it hits CZcams on my Facebook Page:
    / landtohouse
    Land To House is a participant in the Amazon Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com

Komentáře • 26

  • @GavinStoneDIY
    @GavinStoneDIY Před 3 měsíci +4

    The inverter only needs one of the battery cables each. Even that is over kill. Since those cables are 2/0 and you really only need around 1awg cable. So you could install some lugs on there and remove 2 of those. Love these 6kw units. They are solid

  • @jllaine
    @jllaine Před 3 měsíci

    Your power projects have been ambitious and impressive. It's amazing how much they are gifting you in gear for all this.

    • @LandtoHouse
      @LandtoHouse  Před 3 měsíci

      Thank you. Yes. It's surprising how fast companies will send power equipment when you start making videos.

  • @AHMEDGAIUSROME
    @AHMEDGAIUSROME Před 3 měsíci

    THATS A BIG BABY !

  • @randya9143
    @randya9143 Před 3 měsíci

    I was glad to see that you put all the cables in connectors going into the inverter, bare cables going into metal cases worry me !
    These batteries come with two cables for both positive and negative for the larger inverters like the 18k, you only need one for the 6000. No worries until you want to add an additional battery, and then the angle of the connectors on the battery will be a problem for the parallel connection cables.
    Just FYI, that big battery is exactly like the EG4 brand that is sold by Signature Solar and Current Connected.
    One more note is that the battery is a 14.3kw, not a 15kw.

  • @cowboy777120031
    @cowboy777120031 Před 3 měsíci

    First one keep up the good work love seeing your videos

    • @LandtoHouse
      @LandtoHouse  Před 3 měsíci +1

      Thank you. This system has worked very well in the shop.

  • @toughguy1999
    @toughguy1999 Před 3 měsíci

    Did I miss the links you described at the beginning of the video?

  • @bradmesserle999
    @bradmesserle999 Před 3 měsíci +1

    I would have opened the other hole for the negative. Putting both in the one conduit seems shady.. yea these systems are getting pretty darn good.

    • @LandtoHouse
      @LandtoHouse  Před 3 měsíci +1

      That is a valid point. Opening up the other battery cable hole is a good idea. This system has been running over a month with zero problems. I have not dropped the battery below 85% full.

    • @bradmesserle999
      @bradmesserle999 Před 3 měsíci

      That is sweet. Besides money it is really homeowner friendly now.

  • @ChatterontheWire
    @ChatterontheWire Před 3 měsíci

    no groments for the battery up into your wire box for the positive and negative? Seems sketchy having those feed up through those cut outs long term if they shift and rub against the metal of the box to potentially cut them long term. With that said though, nice setup overall.

  • @tomduncan3547
    @tomduncan3547 Před 3 měsíci

    Did you have proper isolation with the positive and negative leads going through the metal box of the inverter.

    • @LandtoHouse
      @LandtoHouse  Před 3 měsíci +1

      You make a good point. I will separate the battery cables so that they go into separate holes in the inverter.

  • @alan72688
    @alan72688 Před 3 měsíci

    Are you switching the neutral and ground? Should you be?

  • @turnerhayes5303
    @turnerhayes5303 Před 3 měsíci +1

    need a ferrule for that stranded wire

    • @LandtoHouse
      @LandtoHouse  Před 3 měsíci

      Those are not standard in the USA.

  • @edc1569
    @edc1569 Před 27 dny

    How much energy can your 15kW battery store?

  • @Foxfried
    @Foxfried Před měsícem

    I thought EG4 made this battery? Is it really made by lux power and EG4 and BigBattery rebrand it?

    • @LandtoHouse
      @LandtoHouse  Před měsícem

      The inverter is a lux power. Eg4 rebrands it and ads some breakers.
      The battery is the same. Bigbattery and eg4 both have a model.

  • @chojthoj08
    @chojthoj08 Před 3 měsíci

    What is the max voltage per 1 mppt? Is it 385v or 480v per 1 mppt or is it half between the 2 mppt???

    • @randya9143
      @randya9143 Před 3 měsíci +1

      On the 6000xp, each pv input is 460v. I used ten of the 400w/37v panels on each input on my inverter.

    • @chojthoj08
      @chojthoj08 Před 3 měsíci

      ​@@randya9143I see. Thank you 👍🏼

  • @bullithedjames937
    @bullithedjames937 Před 3 měsíci

    Conduat box no spaghetti box