    Join me for an afternoon of testing and inspection on an unoccupied 1 bedroom flat.
    The following ADVERTS help our channel to survive:
    Products Used in this video:
    CK 3.5mm Rethreading Tool: amzn.to/373iwQb
    Wera VDE Screwdriver Set: amzn.to/2XUhPVj
    Fluke 1664FC: amzn.to/3g6tyID
    Long Wander Lead: amzn.to/2LH4Y37
    Kewtech Kewprove Kit: amzn.to/36ajlWU
    Kewtech Voltage Tester: amzn.to/2WLJjNw
    🏷️ DISCOUNT BUSINESS SUPPLIES 👇
    ➤ www.amazon.co.uk/tryAB/?tag=a...
    -----TRADES INSURANCE DISCOUNT-----
    If you need to renew your public liability insurance or need tools in van insurance, I recommend Rhino Trade Insurance, I've just renewed my insurance with them.
    🏷️ Use My Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
    ➤ www.rhinotradeinsurance.com/quote
    📞 or call 01162437904.
    CAUTION: Never work on live electrical installations. If in doubt always seek the advice of a qualified electrician. This video is for entertainment purposes only please do not attempt to copy or recreate. Do so at your own risk.
    ✅ Check Out All Our Favourite Tools Here 👇
    ➤ www.amazon.co.uk/shop/artisan...
    🔔 Subscribe to TOOLS4SPARKS CZcams Channel 👇
    I Also Have A Dedicated CZcams Channel About Tools:
    ➤ / tools4sparks
    -----TESLA REFERRAL CODE-----
    🚀 You Can Use My Referral Link To Get 1,000 Free Supercharger Miles On A New Tesla 👇
    ➤ ts.la/andrew24855
    🏷️😱 MY ENERGY PROVIDER:
    Bulb - Use this referral link and we will both receive £50! www.bulb.me/andrew8530
    DRIVE ELECTRIC:
    If you're thinking of getting an electric car and going with leasing, contact Francesca at Drive Electric, if you tell her you came from Artisan Electrics she will look after you.
    www.drive-electric.co.uk or email: francesca.decozar@drive-electric.co.uk
    Use my referral code if you get a Tesla: andrew24855
    CHECKATRADE:
    🏷️😱 Get a £50 voucher when you join Checkatrade quoting our Member ID: 505219
    join.checkatrade.com/friend
    FREE STOCK SHARE worth up to £⁠100:
    Create a Trading 212 Invest account using this link www.trading212.com/invite/FAtr and we both get a free share!
    AMAZON DEALS:
    Amazon Prime FREE for 30 Days:
    www.amazon.co.uk/tryprimefree?...
    FREE 30 day Membership to Amazon Prime Video is available here:
    www.amazon.co.uk/gp/video/prim...
    FREE Amazon Music UNLIMITED for 30 days here:
    www.amazon.co.uk/gp/dmusic/pro...
    FREE 30 Days Audible subscription here:
    www.amazon.co.uk/Audible-Membe...
    📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
    📸 Artisan Electrics Instagram Account 👇
    ➤ / artisanelectrics
    🐦 Artisan Electrics Twitter Account 👇
    ➤ / artelectrics
    📓 Artisan Electrics Facebook Account 👇
    ➤ / artisanelectrics
    This video is for entertainment purposes only please do not attempt to copy or recreate it. Do so at your own risk.
    #ElectricianLife #ElectricalTesting #ArtisanElectrics
  • Věda a technologie

Komentáře • 235

  • @dlewis129
    @dlewis129 Před 4 lety +30

    Always do both sides of a double socket as you can sometimes get a dodgy one with damaged internals or loose pins

  • @neilcoult8843
    @neilcoult8843 Před 4 lety +7

    I got my self a r2 wandering lead kewtech version, after i saw you using yours, love it answers so many questions already found my first metal light with no earth on it within one day. Thanks for the content.

  • @paultipton743
    @paultipton743 Před 4 lety +27

    Switched fused connection unit high up in the kitchen would of been for another down flow heater most commonly found in 80's 90's houses with storage heaters

    • @bobbybiggs4348
      @bobbybiggs4348 Před 3 lety +1

      Would never have worked that out. I was born in the late 80s so before my time really.

  • @jonahs4521
    @jonahs4521 Před 4 lety +17

    I'm 27 and training to become an electrician, watch your videos all the time, learning a lot from them. especially with the college shut due to the virus, it means i am still able to learn bits.

    • @artisanelectrics
      @artisanelectrics  Před 4 lety +4

      Thanks that’s great to hear!

    • @TheChipmunk2008
      @TheChipmunk2008 Před 4 lety +6

      Jonah, you could do a lot worse than watch Jordan's videos. I'm a grumpy old git who was trained to the 16th edition by people who were trained to the 14th... His common sense approach is a breath of fresh air in this world

    • @luluboxingtv2880
      @luluboxingtv2880 Před 2 lety

      @@TheChipmunk2008 we’re you one of them old boys that used to talk to apprentices like shit then?

    • @TheChipmunk2008
      @TheChipmunk2008 Před 2 lety +1

      @@luluboxingtv2880 totally the opposite, i was one of the apprentices. LOL

    • @TheChipmunk2008
      @TheChipmunk2008 Před 2 lety +1

      Although to be fair, the work environment i trained in was not toxic to trainees, so i didn't see any of the bullying, which is good.

  • @dynaman1600
    @dynaman1600 Před 4 lety +1

    Fine liked watching the way you tested the ring main never got my head round that 2391 17th on the cross connection testing. I always remember PEIR . Polarity. Earthing Insulation Ring Main Continuity . Always thought they made the testing more time consuming so you would ditch Ring Mains for Radials. Also would use my side cutters with the 3.5 threaded hole to cut the screws down thanks Jordan.

  • @oobaseki
    @oobaseki Před 3 lety +5

    I was quite impressed with your very detailed and thorough approach to testing. Also very transparent. I would have thought the proposed time scale for the next inspection would be 6 months instead of 1 year (I stand to be corrected), with regards to a follow up on the recommended remedial action.
    But all the same very well done.. I look forward to seeing more of your video clips.

  • @imtrue2132
    @imtrue2132 Před 3 lety +10

    Did I just see sparks at 19:01 from the CU? Seconds after you moved your eyes to the 'megger'.

    • @bazwell1846
      @bazwell1846 Před 3 lety +1

      That’s why you pay the big bucks for his EICR

  • @fionamstacey
    @fionamstacey Před 3 lety

    Thank you for this video. It was very helpful as my tenants wanted to know if every socket had to be accessible but I didn't know as it's the first time getting it done for me.
    My property looks the same age and very similar wiring to this so now I'm panicking mine will fail on something too.

  • @stephengreen909
    @stephengreen909 Před 4 lety

    Love these kind of videos.
    Very educational.
    🌟🌟🌟🌟🌟

  • @belightltd
    @belightltd Před 3 lety +1

    After using my fluke for around 3 years and manually pressing test button I found out (thanks to your videos) that I can use the probe button (never used that red probe). Thanks.

  • @SouthwestIndustrialElectric

    The details in this video are great! Thanks for sharing.

  • @waithereivegonetogethelp3240

    I find it's worth testing both sides of a double socket when going around doing the zs's, if nothing else it flags issues like internal connections becoming loose, unable to get the plug to in due to damage, wear and tear, foreign bodies stuck in etc.. I find lots of doubles where one side is fine and the other is unusable.

  • @faisalhussain589
    @faisalhussain589 Před 4 lety +2

    Jordon well done mate, clear and concise video.

  • @williamcross3904
    @williamcross3904 Před 4 lety +2

    Your reference to bad smells...I worked in a house last year and there was dog turds on the carpet and the house smelt unpleasant everywhere luckily I only had to fault find an alarm system. I've been in house before where theres dead bones in the loft and maggots yeah I get all the good jobs 😬. Enjoyed your video, interesting content.

    • @artisanelectrics
      @artisanelectrics  Před 4 lety +1

      Wow that’s awful

    • @zedzed1046
      @zedzed1046 Před 2 lety

      Is that in relation to live bones, found plenty of dead birds in flues.🤔🤔🤔

  • @jamesdyas542
    @jamesdyas542 Před 4 lety +1

    One of the night store points may have gone to the blank plate in the airing cupboard for an off peak immersion. Excellent videos thanks.

  • @mohammedawais8821
    @mohammedawais8821 Před 4 lety

    Great work Jordan keep the videos coming 👍🏽

  • @av8r.007
    @av8r.007 Před 3 lety

    All looks good, thorough job

  • @ibrahimabdullah4430
    @ibrahimabdullah4430 Před 4 lety +1

    Thanks 😊
    😎 another great video like always.

  • @skyfsa
    @skyfsa Před 4 lety +2

    I think your judgment was sound and the job a good one.

  • @eamonnohalloran2254
    @eamonnohalloran2254 Před 3 lety +2

    Hi Jordan. New to your channel. I am concerned that you continue to ware your wedding ring while working in live panels . its day one advice to apprentices.
    I have been an electrician for 26 years here in the states . Enjoy your vlogs and your attention detail. its interesting to see how methods are done in the UK. There seems to be cowboys everywhere.

  • @nickpalmer7939
    @nickpalmer7939 Před 4 lety +2

    Hi Jordan, really enjoyed your video and agree with your conclusions/coding. I personally use a draper CT4 to shorten the m3.5 screws (very cheap tool) but gives a reasonably clean cut end. It can also be used to cut m4 & m5, but I’ve never tried those sizes. Keep up the good work!

  • @jesseoconnell4369
    @jesseoconnell4369 Před 3 lety

    Awesome video thanks Jordan. It really helps to be able to see an EICR in practice for a learner like me! Nice shoes too! Do you have a link for them?

  • @neil6438
    @neil6438 Před 4 lety +2

    C2 for bathroom light if live connections outside of enclosure.

  • @RuchOporuElektryk
    @RuchOporuElektryk Před 4 lety +3

    At 22:18 - IP rating of the light - as you said - it is outside of zones. Re: screws - Screwfix has mid length (40mm)?

  • @davidmullaney8844
    @davidmullaney8844 Před 3 lety +1

    That shadow really brings out ur complexion 😁

  • @almerdiahmed3160
    @almerdiahmed3160 Před 6 měsíci

    Nice job Thanks ❤❤❤❤🎉🎉🎉🎉Happy new year.

  • @rod9311
    @rod9311 Před 4 lety +4

    R2 Test in parallel and why disconnect main bond at gas pipe and not at met / cu bond point?

  • @johnwaby4321
    @johnwaby4321 Před 3 lety +4

    If you keep putting C3 code for most items then the installation will never get updated to the current regulations. .and if the client wants you to change or redo the lights in the bathroom then you will have to fit rccd protection . So how can you go back to the Client to tell him you have to replace the consumer unit . When you have already passed it with codes C3..
    You will have to state that the installation requires to be updated to the current regulations to cover yourself. .

  • @jeffmoye
    @jeffmoye Před 4 lety +2

    No RCD protection means supplementary bonding is required as per current and previous regs. Might have been what that 2.5mm2 earth cable was in the bathroom... The bathroom / kitchen fitters might not have re-instated the bonding thinking that it’s not required under 18th regs, forgetting that that is only the case if rcd’s are fitted.

  • @Mickodb
    @Mickodb Před 3 lety

    The niceic says you don’t need both r2 and r1+r2. If you choose to test r2 you then still need to measure r1+r2 to establish your Zs . The Niceic have said not to carry out live Zs testing, as do many large employers, you should add ze to your r1+r2 to get zs.
    I would agree with the r2 on metal cased fittings though , or just r1+r2 at any that are metal as well as the end of line .
    Socket outlets in domestic properties without rcd protection are an instant c2 IMO, lights c3

  • @Thelectrical
    @Thelectrical Před 4 lety +1

    I always keep a bag of M3.5 x 35mm screws in the van. Comes in very handy

    • @artisanelectrics
      @artisanelectrics  Před 4 lety

      Nice tip!

    • @findmelightsdotcom9280
      @findmelightsdotcom9280 Před 3 lety

      I met an old electrician once who never knew you could cut them down. Went through his whole career and never knew 🤣🤣🙃

  • @johnflower8648
    @johnflower8648 Před 4 lety +8

    Regarding tapped holes in back boxes, if it's old it is probably 4BA and not 3.5mm.

    • @stevethomas5849
      @stevethomas5849 Před 2 lety

      I have a set of BA sockets in 1/4 inch, old school gauge days none of this metric

    • @bambam-cm8we
      @bambam-cm8we Před 8 měsíci

      😂 the difference is ever so slight, but it makes ALL the difference. Took me far too long to figure that one out, fun times

  • @hawk_ness
    @hawk_ness Před 4 lety +5

    19:00 Sparkie by name, sparkie by nature ;)

  • @simonmatthewwright1221
    @simonmatthewwright1221 Před 7 měsíci

    The high Fused Spur in the kitchen could be for the Gas Hob Ignition behind the Oven

  • @GreenHawkConstructionltd
    @GreenHawkConstructionltd Před 4 lety +1

    Another great video mate just watched it as I am waiting for mine to upload onto CZcams. Keep up the good work 👍

  • @nigelcharteris
    @nigelcharteris Před 3 lety +10

    Hi Jordan, Great Video. A couple of tips! You can buy 40mm long 3.5mm screws which seem to be the most useful length. Cutting them with side cutters is often the cause of damage to threads in the back boxes; better to use a 'shear' tool to shorten the screws if you have to. Insulation resistance, I always do Line to Neutral at 250V first to see if there is any load connected because 500Volts between Line and CPC can damage components within appliances. I don't think you did a figure 8 R1+R2 test on the sockets; do you think R2 with the wander lead is adequate for all circuits including sockets? Thanks

    • @galaxion62
      @galaxion62 Před rokem +1

      Shear tools are not the perfect solution either, a small chamfer applied with a small file, or an emery block is best in order to create a lead in for the thread to start correctly without becoming cross threaded, which is the cause of this issue.

    • @nigelcharteris
      @nigelcharteris Před rokem +2

      @@galaxion62 Hi Jordan agreed shear tool not perfect...actually when you think 3.5m screws have been used since....40's?...long before?.... the real solution probably lies in a different modern universally accepted fixing and termination screws standardised so you don't have to carry 8, 9 10 screw drivers around all the time, dream-on! - re-threading during EICRs and repairs enough to do your head in........

    • @Danhamer1988
      @Danhamer1988 Před 2 měsíci

      It doesn’t prove polarity on sockets so I don’t think it is

  • @stevethomas5849
    @stevethomas5849 Před 2 lety

    my 3.5 rethreather has been snapped off for a long time and its still working fine.

  • @Umski
    @Umski Před 4 lety +1

    Graham Barber - that's a familiar name - turns out he did the entire fit out in our place in Soham (previous owners built the house around 2000/2001) - the stuff he did looks sound, some of the add-ons that have were put in after him (I suspect) look decidedly ropey :s

  • @johnwaby4321
    @johnwaby4321 Před 3 lety

    Don't forget cables concealed in the walls. Why did you not switch off the boiler spur to carry out the insulation resistance test on this circuit. .. Nice bit of testing .

  • @paultipton743
    @paultipton743 Před 4 lety

    I just brought the ck 3.5 rethreader as well as I lost mine( I'll probably find it in the van again).
    Heaters in houses in the 80s were usually Storage heaters downstairs and Panel heaters in the bedrooms, your generous on the one year of c2s I've given Just one month before lol

    • @artisanelectrics
      @artisanelectrics  Před 4 lety

      Yeah I’ve already fitted a new Hager RCBO board there, that video will come next.

    • @paultipton743
      @paultipton743 Před 4 lety

      @@artisanelectrics sorry I deleted the comment about the consumer unit as you mentioned it later in the video

    • @SME_Ste
      @SME_Ste Před 4 lety +2

      Should try the armeg rethreader, longer than the CK and can rethread through the socket hole

  • @jacala71
    @jacala71 Před 4 lety +1

    Hi Jordan. Like you we are being asked to do plenty of EICRs for landlords.Please don’t take it as a criticism as anything to make them quicker all for the better. I assume that I’m over egging the pudding it as I include R1+R2 readings, as you are doing R2 will that be enough on the cert at the end. ?

  • @gd-bq7em
    @gd-bq7em Před 3 lety +1

    Hi do you just fill the r2 column on cert or do you also do you r1 and r2 readings as well

  • @grahammchardy9249
    @grahammchardy9249 Před 4 lety +1

    Like the idea of doing end to ends done at the socket. I live in a house with everything twisted together😫

  • @alantorrance6153
    @alantorrance6153 Před 3 lety +1

    All very well giving them 1 year to make improvements, but do the regs require the installation to be updated? It can be that an existing installation, if it has no faults under the regs it was installed under, can continue. Be careful you do not get yourself a bad name for unnecessary changes.

  • @davidclarke2513
    @davidclarke2513 Před 8 měsíci

    The best cutting tool for cutting 3.5mm socket outlet screws are the very old crimping tools which have pre threaded hole in their handles which allows you to screw the 3.5 screws into it to get a clean cut,I beleive you can still purchase those

  • @findmelightsdotcom9280

    Hi Jordan
    On a test, do you charge a price for the board plus circuits or just your hourly rate?
    Also how long does the average test take for you eg. This flat?
    Cheers!

  • @jamesfollon
    @jamesfollon Před 3 lety

    I would be wary of untwisting those cpcs , copper work hardens and becomes brittle. If one of those cpcs snapped it would cause an awkward situation to resolve. In general you don't want create additional damage.

  • @franciscoafonsoferro5568

    one grat OK because of the Shadow :-D, good job!

  • @electricery
    @electricery Před 4 lety +2

    20:50 did you check the other end of the gas bond on the inside wall to see if it is in the same sealed tube as the gas pipe and and if it not then mention the gas bond passing through the back of the meter box and through the cavity (thus potentially allowing leaking gas to drop into the cavity )

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t Před 2 lety

      Good point but which a squirt of intumescent sealant would take care of in a jiffy

  • @SME_Ste
    @SME_Ste Před 4 lety

    Test a the socket and note Jordan, life’s to short for messing in those old consumer units. Worst case you’ll get a lower than expected r2 but prove the ring is complete with no rings of the ring and get your R1R2. Jobs a goodun

  • @stevecraft00
    @stevecraft00 Před 4 lety +1

    Stopcock. Never surprises me these days where they are. Did a flat in a small council block. Single storey flats ground floor and then duplex flats on the first and second floors. We were doing a duplex upstairs. Asked the tenant where the stop cock was. She said it was in the bathroom (on the second floor). I insisted it couldn't be. Went to look and yes, there it was. Very odd. 🤔

  • @robertmason8554
    @robertmason8554 Před 11 měsíci

    Hi just watched this video and found it very informative. as i'm just trying to get started with EICR testing it would be good to know what he readings should be for the various tests and what settings the meter needs to on. I am a fully qualified electrician but only up too 16th addition do i need to get any other qualification to allow me too do EICR reports?
    thanks
    Bob

  • @lewishumphries2893
    @lewishumphries2893 Před 9 měsíci

    Great video as always. Just a question, if the cover came of the isolater at the DB could you not do the Ze from there? Looks like the main earth would of came out. Or am i missing something? To risky?

  • @royhorn9412
    @royhorn9412 Před 2 měsíci

    You probs should check both sides of the doubles if you are doing every socket.

  • @henrybartlett1986
    @henrybartlett1986 Před 3 lety

    Excellent.

  • @mattk5020
    @mattk5020 Před 2 měsíci

    I've got a test coming up this week in my flat which is owned by a housing company. I've unplugged my soundbar and sub and speakers from the extension lead. Should I be concerned with a test?

  • @ThePaulmj85
    @ThePaulmj85 Před 23 dny

    The spur in the kitchen at high level would be for a down flow heater mate

  • @natashamcevoy6368
    @natashamcevoy6368 Před 2 lety

    If a tenant is still living in a property while a test is done do you have to move white goods to get to the sockets?

  • @TheChipmunk2008
    @TheChipmunk2008 Před 4 lety +7

    C3 for no rcd on the sockets... it was fine when installed. Supp bonding everything including your fly zip is a 16th edition thing, what date did that take over from 15th?

  • @lansdorf
    @lansdorf Před 4 lety

    If the single earth tag on the boiler fuse spur lined up with the non fixed lug on the metal back box then would you put a link to the metal back box as it's not connected to a fixed lug. Enjoyed the video.

    • @artisanelectrics
      @artisanelectrics  Před 4 lety +1

      Good question! John ward just made a video about this, you should check it out!

  • @ivansimpson8397
    @ivansimpson8397 Před rokem +1

    Why don’t you check for back bonding on eicr

  • @xylo66
    @xylo66 Před 4 lety +2

    For the sake of a few extra seconds, I prefer threading the 3.5mm pattress machine screws thru a combi cutter which shears them off nice and square and never have issues with cross threading. Takes a few seconds longer but neater.

    • @artisanelectrics
      @artisanelectrics  Před 4 lety

      Which combi cutter do you use?

    • @SME_Ste
      @SME_Ste Před 4 lety +1

      My NWS pliers have this function too, brilliant no crossed threads

    • @davemorgan7695
      @davemorgan7695 Před 4 lety

      I use the KNIP CRIMPING PLIER 240MM, also makes a nice clean cut.

  • @johnburke8713
    @johnburke8713 Před 3 lety +1

    Was that 1g socket box earthed?

  • @joshthespark8394
    @joshthespark8394 Před 4 lety +10

    Careful of shadows Jordan lol 😝

  • @steve11211
    @steve11211 Před 4 lety +8

    For the Ze you could have just removed the bonding conductors at the clamp side which would have isolated them from the main earth? Also when doing R2 you should really remove the bonding to avoid any parallel paths (Though not likely to be an issue). Although I totally agree a new RCBO or dual RCD board is by far the better option, another alternative to becoming compliant would be to change the downstairs socket to a socket with combined RCD and FCU with RCD for the heater in the bathroom as that would then comply.
    Are you seeing more work for EICR with the changes to landlord legislation requiring EICR's?

    • @Thelectrical
      @Thelectrical Před 4 lety +1

      I’ve said the same about parallel paths in a couple of previous videos.

    • @WesOufc
      @WesOufc Před rokem

      Was always told do your bond test then leave disconnected do your r1+r2 or r2then re connect prior to IR tests

  • @davidmarsden8868
    @davidmarsden8868 Před 4 lety

    Still waiting for the in depth review of your fluke 1664fc

  • @bagelsfury8971
    @bagelsfury8971 Před 3 lety

    Hi I’m a young spark and have not a lot of experience in EICR’s what I do know was either self taught via books or CZcams. Was wondering if you checked every point (dropped a switch or socket forward) and tested from every point or is it just more like test majority of points and if anything suspect is found you’ll check every point? Thanks love your videos

    • @JamesLawlor
      @JamesLawlor Před 3 lety +1

      Test 10% on larger properties, if there is a lot if issues found initially, then it is worth testing more if not everything. As this was a small property, it made sense to test everything.

  • @johnway2039
    @johnway2039 Před 4 lety

    the 2.5mm cable attached to the main water bonding was probably a supplementary bonding cable. do you not need to test for that since there is no rcd ? would be great to see that in the video

    • @Mainly_Electrical
      @Mainly_Electrical Před 4 lety

      Should be verifying supplementary bonding in the bathroom if no additional protection on all ccts within otherwise it’s a c2 ,

  • @johnholkham2420
    @johnholkham2420 Před 11 měsíci

    Can you have an electric heater in the bathroom is the a restriction that they should be a something 44 rated which I’m sure that heater is not.

  • @AceRimmer_
    @AceRimmer_ Před 3 lety

    Do you not check inside the RCD?

  • @alexkearney2720
    @alexkearney2720 Před 2 lety +2

    I didn't see any R1+R2 testing? Only a Zs... How was you calculating R1+R2 as I was always told subtracting Ze from Zs was a naughty way of doing it. Is that correct?

  • @interstat2222
    @interstat2222 Před 3 lety

    How is anyone supposed to use a living room of that size? And where's the Fridge supposed to go?
    Who designs/builds these things?

  • @scott1506
    @scott1506 Před 3 lety

    so why did this fail and need a new rcbo fusebox?

  • @ryanallen3704
    @ryanallen3704 Před 3 lety

    How was that light end of line at 10.22 ? It simply had a neutral and a switch line. (Meaning a junction box in the attick/loft)

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t Před 2 lety

      It looked end of line to me whether power fed from the switch or fed from the ceiling. Last in the run as no loop out. why would you need a junction box with a pendant ?

  • @cjmillsnun
    @cjmillsnun Před 4 lety +8

    Anything correctly wired to previous versions of the regs cannot be coded to anything other than C3 (unless you've got something obviously dangerous like VIR cables or wooden back CUs) So the lack of RCD protection (normal for a property of that age) is a C3.

    • @paulmccann4171
      @paulmccann4171 Před 4 lety +4

      Nope. External sockets and bathrooms with out sub bonding require an RCD

    • @fightdisciple9192
      @fightdisciple9192 Před 4 lety +3

      Wrong. No RCD protection for sockets AND Lighting is a c2 . I really wish people would stop thinking old wiring regs is a pass it’s absolutely ridiculous

    • @wazharrison186
      @wazharrison186 Před 3 lety

      The problem arises because Guidance Note 3 says No RCD protection is a C3 which is what is taught on 2391 (I teach it for a living) However I have always tested to latest regs so Sockets no RCD for use outside should be a C2, No RCD in bathroom with no Supp Bonding is a C2 as per Best Practice Guide 4 and the Napit Codebreakers book.

  • @bazza4u
    @bazza4u Před 2 lety

    Hi there, I’ve recently bought a property in london which has an ancient fuse panel … looks like it’s from the war! I’m concerned that this is only the harbinger of things to be uncovered when I get an eicr done … I’ve been impressed by the work you have done in your videos and you sound very sensible and fair … possibly a bit of a tough question but are there any electricians you would recommend in london who are as thorough and ethical as you are? I don’t want to engage a cowboy who quotes low and then piles on the costs …

    • @carlmarquardt994
      @carlmarquardt994 Před 2 lety

      Check out Thomas Nargy. He has clips on here and works in London.

  • @johninhono7
    @johninhono7 Před 4 lety

    How are you proving polarity before re-energising the circuits when you only use the R2 method for proving continuity of earth at accessories?

    • @SME_Ste
      @SME_Ste Před 4 lety

      John MacLean bare in mind this isn’t initial verification

    • @artisanelectrics
      @artisanelectrics  Před 4 lety +3

      Polarity is done when doing Zs test

  • @Mainly_Electrical
    @Mainly_Electrical Před 4 lety +9

    Supplementary bonding in bathrooms ? , another c2 on the list if not installed

    • @SME_Ste
      @SME_Ste Před 4 lety +3

      This is missed by sooo many ‘electrical inspectirs’

    • @TheChipmunk2008
      @TheChipmunk2008 Před 4 lety

      @@SME_Ste I look for it, (trained in 1989 but no current quals except for 18th ed)... my colleague (who did 2391) doesn't ever pick it up lol
      But I am still way more competent (and so is he!) than any of these 'ooo i need part pee' course people. Bitter? yes

  • @royhorn9412
    @royhorn9412 Před 2 měsíci

    Did you ever check that the light was class 2 - it looked like one of the modern class 2 lights. No earh required.

  • @alanjmasters
    @alanjmasters Před 3 lety

    Hi will an eicr test pick up a loose wire connection in a socket outlet? Thanks

  • @joey06051988
    @joey06051988 Před 4 lety

    Hi All,
    My comment is not really related to the video.
    There was a previous company who did an EICR on a bus station and for some reasons all the circuits in the DB in the office has been marked as "Unable to locate". I have been assigned for remedial work to locate these circuits. What type of certificate do I use and why?
    Thank you

    • @joey06051988
      @joey06051988 Před 4 lety

      PS this job has already been completed and I have used the EICR for it. However my supervisor does not totally agree with this despite all the reasons I gave, which is why I am asking for second opinions.

  • @garybarraclough305
    @garybarraclough305 Před 10 měsíci

    Hmmm testing 500 volt at first with vulnerable circuits ie boiler and cooker pcr board in line with cooker control unit in on position hmmm I like you tested all earths at all switches a sure fire miss with a lot of testers obviously if dry lining box won’t show up but good practise

  • @mfjbrennan
    @mfjbrennan Před 3 lety

    Another good video Jordan. Am assuming the new LED light fitting in the kitchen was a class 2 as you skip that in the video ?

  • @RWATraineeElectrician
    @RWATraineeElectrician Před 4 lety +4

    Your shadow looks like one of those statues on Easter Island 😆😆😆

  • @SPARKY400T
    @SPARKY400T Před 4 lety +1

    When testing bonding conductors disconnect at consumer unit and test between there and the pipe the bonding clamp is connected to that way it makes sure the bonding clamp connection onto the pipework is good thats how I do it anyway

  • @enriquedmu1
    @enriquedmu1 Před 4 lety

    is there a reason why you wouldn't make right the light polarity, while your there? I'm not criticising, as we all have slightly different ideas and ways of doing things, just interested in your stance on it. Is it to save on time, as you may of given a fixed price which does not account for remedial work during inspection? Either way, the customer is getting a proper job there, and were getting a good video to watch.

    • @artisanelectrics
      @artisanelectrics  Před 4 lety

      Thanks I could have done it I guess but just didn’t see the need.

    • @enriquedmu1
      @enriquedmu1 Před 4 lety

      @@artisanelectrics fair enough. I suppose the client gets the service they pay for, just watched your video when you explain that the timings are tight due to how much your being payed. If they pay just for the inspection and tesing, then its a fair one, if they give a fair price where you can spend a bit more time, then you can help them out. Cheers Jordon for getting back. Little interactions like these help me learn.

  • @randyvalantino6850
    @randyvalantino6850 Před 2 lety

    The fine for a landlord for not having a test is £200 . You have to wat up if it's worth getting done . Just pay the fine if found out

  • @Clarke789
    @Clarke789 Před 2 lety

    No RCD protection for the lighting neither!

  • @Marco-mg9tv
    @Marco-mg9tv Před 4 lety +6

    Still don’t understand why you do r2 then zs when you could just do r1+r2 dead and no need for chopsticks live zs testing on the lights

    • @TheChipmunk2008
      @TheChipmunk2008 Před 4 lety

      more tests are better. This whole crap about 'ooo there's a possibility of contact with a live conductor' using GS38 compliant probes.... is just H&S BS. he's being conscientious

    • @Gymreview84
      @Gymreview84 Před 2 lety

      If you do R1 +R2 you don't need to do zs? Do you then calculate zs by adding ze and r1 and R2 ?

    • @Marco-mg9tv
      @Marco-mg9tv Před 2 lety

      @@Gymreview84 correct

    • @Gymreview84
      @Gymreview84 Před 2 lety

      @@Marco-mg9tv thanks buddy . I passed my test and inspect in 2014 but I've done no testing since at all so I'm reading up on it

  • @TWOKDOK1
    @TWOKDOK1 Před 3 lety +1

    I think you need to look under loft insulation to see if cables are underneath (incorrect). Also what what is the 2.5 cable at stopcock used for? CUs too high . Socket under unit should not be fixed to carcass / rear hardboard.

  • @rssteve16
    @rssteve16 Před 3 lety

    Exactly 19:00 sparks fly

  • @rowles13
    @rowles13 Před 4 lety +3

    C2 on the bathroom light

  • @iainmccubbin1353
    @iainmccubbin1353 Před 4 lety +1

    Isn't there supposed to be mains fire alarm in a rental property?

    • @paulmccann4171
      @paulmccann4171 Před 4 lety +1

      Doesnt come under EICRs
      Plus that's only council in private rentals batteries are fine

    • @wazharrison186
      @wazharrison186 Před 3 lety +1

      Hi Paul sadly you are wrong about the fire alarm there is a requirement under The Domestic Fire Alarm Regulations [BS 5839 Part 6 - 2019] that by no later than 01/04/2021 ALL rental properties in England and Wales must have a minimum of a Grade D LD2 smoke alarm system which means Mains Powered and interlinked Smoke in Entrance Hall and Landing within 7.5 meters of every bedroom, 1 in any living rooms and a heat alarm in the kitchen. The only use of Battery allowed now is if they are 10 year non removable lithium ion batteries but they still need to be interlinked via radio link if necessary. I appreciate this video was shot before that but this date has been set in stone for over 2 years now.

    • @pshelectrical1286
      @pshelectrical1286 Před 2 lety

      @@wazharrison186 not in wales standard battery ones still are ok regulations haven’t changed yet unless the property was built after 1992 .it’s really poor and they still haven’t enforced eicrs only good landlords have them done .

  • @user-mb4uz6lk3l
    @user-mb4uz6lk3l Před rokem

    are smart meters bad for human health ?

  • @MrLarryc73
    @MrLarryc73 Před 3 lety

    Can someone please answer me if RCBO’s are a legal requirement these days on a kitchen ring in a tenanted property ?
    As I think the sparks who’s recently tested is giving me false information. It’s a safety certificate after all and surly this should only be an improvement.

    • @artisanelectrics
      @artisanelectrics  Před 3 lety

      If you currently have RCD protection for your sockets then you should have, and RCBO is a good way of doing it.

    • @MrLarryc73
      @MrLarryc73 Před 3 lety

      Thank you for replying.
      RCD protection was only on up and down rings but not on the kitchen and oven circuits. The test was failed for that reason. I was told any circuits 32amp or above need to be protected.
      Was the electrician correct in saying this regarding the 18th Edition regulations.
      This is for a rental property.

  • @georgemacwan2434
    @georgemacwan2434 Před 3 lety

    IR test with line and neutral with 500vDc ?????

    • @JamesLawlor
      @JamesLawlor Před 3 lety

      He switched to 250v for L+N test. Only one the redundant board with nothing connected, he retested at 500v

  • @TheUkjedi
    @TheUkjedi Před 2 lety

    Can't hear it

  • @wlondoner
    @wlondoner Před 4 lety +18

    Why would you render the installation deemed to be potentially dangerous while it was perfectly legal at the time of the installation???Was the 16th edition and its amendments dangerous at the time of the installation not implementing an ADS. I am sure we all know RCDs were around away before the 16th edition and Mr BS 7671 didn’t feel like to put them in the regs or perhaps he forgot!!!
    The regs were genuinely designed to keep the consumer safe. How do we know, what you are doing will be perfectly legal in 5years time or so, when 19th or 20th edition comes along.
    c2 and c1 codes are for a potential danger, ie live conductors are clearly exposed causing an imminent and immediate danger. Deterioration of the installation, risk of fire, alarming reading..... Omission of an RCD in a new installation I would agree but in an old house it is clearly a c3 or perhaps if you want to be an orthodox suggest an RCD SOCKET close to the main door.

    • @fightdisciple9192
      @fightdisciple9192 Před 4 lety +14

      On your thinking you’d have rewireable fuses , non fire rated downlights & vulcanised rubber cable down as a pass. Times change, things move on and get safer. Properties need to be up to the most up to date regulations. Poor Mr Smith got an electric shock & died, such a shame he didn’t get told to put RCD protection on his electrics - still , at least it was safe at the time of install.

    • @steverobinson8170
      @steverobinson8170 Před 4 lety +8

      Wlondoner is correct, the installation met regulations and still does meet the regulations for when it was installed. New regulations do not mean an automatic fail of old circuits , following your thinking all properties more than 20 years old need to be bulldozed because they fail to meet the latest standards , which is plain silly . This is why we have codes which deem what is and is not a failure . Yes by all means advise the client the electrical system isnt up to todays regulations , this doesnt automatically mean its unsafe .

    • @fightdisciple9192
      @fightdisciple9192 Před 4 lety +4

      steve robinson no - following my thinking we would replace consumer units where necessary and rectify any faults. This is the issue , overhyping the extent of works, it’s usually a days rectification if that.

    • @rrenvrrenv8014
      @rrenvrrenv8014 Před 4 lety +7

      The coding is at the discretion of the inspector,there are 2 main issues
      1. Inspectors giving c1 and c2 codes when they should only be c3 improvement recommended
      And
      2. Inspectors who have only been on a 5 week course and have no experience or knowledge of electrical installations so they code 2 everything to be on the safe side

    • @TheChipmunk2008
      @TheChipmunk2008 Před 4 lety +6

      @@fightdisciple9192 Absolutely correct. None of those would be a anything more than a C3 provided the rubber cable was in good condition (it rarely is)
      C3 allows you to add recommendations in a separate field. Rubber cable would be a 'STRONGLY RECOMMENDED THE CUSTOMER HAS THE PROPERTY REWIRED' (IN ALL CAPS) but it is absolutely NOT a fail if it was fine when installed and still complies to THOSE standards.
      One of the few cases where i'd agree with you is neutral fusing. That is demonstrably dangerous with a single fault. That would be a C2
      Edit: on thought, rubber wiring would be a FI.. you'd need to take off every accessory and find every JB to ensure it was compliant. But I am still angry at your kind of thinking where every house in the entire country needs rewiring for every amendment. As a person in an owner occupied property... I say 'screw that'

  • @davidclarke2513
    @davidclarke2513 Před 8 měsíci

    As a recently retired industrial JIB GOLD CARD APPROVED Electrician of 50 years I would like your opinion,not what the so called regs bible says but what's your opinion on them saying that there is no need (not requirement) for a cpc to be wired to a non metallic light fitting,because in my whole career starting as a young apprentice I had it drummed into me that unless it's a extra low voltage source that you are wiring then as good electrical practice,which by the way I have never heard used on your podcasts or several others I've been on ever mentioned that word ,I was taught that the need for a cpc was that even though the source didn't require an earthwire we 100% of the time and I'm going back to 1970 when I started I was told the need for a cpc being run in a twin and earth cable or a flex is to afford some sort of protection for that cable or for somebody who may accidently penertrate that cable there would be at least a chance that the earthwire may be penertrated along with the line cable thus tripping the circuit and not killing the person,I know that in modern up to date consumer units have technically superb protective devices in place,but all I see you do is to go into properties that don't have them thus telling me my argument about always running a cpc in twin and earth and flexs holds water

  • @dlewis129
    @dlewis129 Před 4 lety

    Thought if you give an unsatisfactory result then they only get 28 days to arrange corrective measures ??

    • @alexkane07
      @alexkane07 Před 4 lety

      Which piece of literature says this? I've been trying to find it for ages.

    • @dlewis129
      @dlewis129 Před 4 lety

      Alex Kane I saw it on one of the recent webinars but can’t for the life of me remember which one

    • @johnbarrett7561
      @johnbarrett7561 Před 4 lety +3

      The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020

    • @Ghbarl
      @Ghbarl Před 4 lety

      Point 7.... www.gov.uk/government/publications/electrical-safety-standards-in-the-private-rented-sector-guidance-for-landlords-tenants-and-local-authorities/guide-for-landlords-electrical-safety-standards-in-the-private-rented-sector

    • @steverobinson8170
      @steverobinson8170 Před 4 lety +2

      @@Ghbarl Doesnt mean all the wiring has to meet 18th regs , if you read the piece of legislation it states (a clip from the regs) Existing installations that have been installed in accordance with earlier editions of the Wiring Regulations may not comply with the 18th edition in every respect. This does not necessarily mean that they are unsafe for continued use or require upgrading. Any works that are code 3 do not require to be performed its at landlord's descretion