Senville Leto Mini-Split Installation

Sdílet
Vložit
  • čas přidán 26. 08. 2024
  • In this video, we install a Senville Leto 18,00 BTU mini-split heat pump in my 2 car garage
    Products used:
    Mini-split: amzn.to/47hbLbj
    Electrical whip: amzn.to/3MoTpNJ
    10/2 wire: amzn.to/3shsxZ2
    Lineset cover: amzn.to/3Mr4hut
    Wall mount kit: amzn.to/3Ms5amA
    Hole saw: amzn.to/3Mqac2I
    Disconnect box: amzn.to/47gHpG1
    Tools used:
    Fieldpiece probe set: amzn.to/3QHL61R
    Compound manifold (cheaper alternative): amzn.to/40mqKhW
    Service wrench: amzn.to/3QmlC8T (bit: amzn.to/3QmlExx)
    Vacuum/micron gauge: amzn.to/3QFPeiW
    5/16 core removal tool: amzn.to/3SrUxnE
    Vacuum hose + 1/4 core removal tool: amzn.to/3s8rV8g
    Vacuum pump (one shown in video not currently available): amzn.to/3QGweB0
    Nitrogen regulator: amzn.to/3QlQfvq
    Rotary/chipping hammer: amzn.to/46US09D

Komentáře • 40

  • @Taino871
    @Taino871 Před 5 dny

    Ok Here comes another THANK YOU I have an elderly neighbor, He has multiple sclerosis and has survived 68 years. He thought HE could stall this… he told me “ Well ya know in theory it’s easy” I chased his butt back into his house… watched your video… and my Buddy has A/C in his living room bedroom. Seriously Thank you.

  • @billsimpson1085
    @billsimpson1085 Před 2 měsíci +2

    Just finished installing this unit myself, saving $1000 over having someone else install it. Your video gave me the confidence to get the job done. Thanks!!!

  • @Tim_Gravy
    @Tim_Gravy Před 2 měsíci +2

    Great Vid, you prob sold 100s of these for senville, i hope they send u a thank you

  • @jond1965
    @jond1965 Před 7 měsíci

    This is what i was looking for! Putting same unit in my cottage soon and this is direct and to the the point!

    • @bq6162
      @bq6162 Před dnem

      Installing one this week in my cottage. How are you liking yours? Any issues?

  • @user-ql2bz8on7m
    @user-ql2bz8on7m Před 2 měsíci +1

    Good job really very professionally done😊

  • @elmeromero1794
    @elmeromero1794 Před 3 měsíci

    I installed one of these but in 9000 btu for my buddy. Works like a charm!!!

  • @Gyppor
    @Gyppor Před měsícem

    Thank you for this video. Were I live contractors will not touch anything they don't sell, and they will sell you a single room 12K unit for anywhere from $5K to $9K Canadian or about $4-7K USD. It's a complete rip-off, the mark-up on the install is unreal. I'm hoping to install one of these Senville units in our bedroom and videos like yours are very useful!

  • @mathewpen
    @mathewpen Před 9 měsíci +1

    Nice install Joe!

  • @ThePopularCult7
    @ThePopularCult7 Před měsícem

    Thanks for all the info.

  • @invisiblestacker
    @invisiblestacker Před 3 měsíci +1

    Looking to install a mini split in bedroom. Could i mount the compressor unit in a garage? Hoa requires compressor to be hidden, a 35 ft freon line run.

    • @JoesGarageProductionsLLC
      @JoesGarageProductionsLLC  Před 3 měsíci

      It would not be a good idea to mount the condensing unit inside of any enclosed room or building. It needs a good supply of air to condense The vapor refrigerant back into a liquid

  • @trieunguyen-ry7sf
    @trieunguyen-ry7sf Před 17 dny

    Hi..earlier in the begining of the video you mention to drain opening is a missing closing cap. How did you close it after all? Thanks

    • @JoesGarageProductionsLLC
      @JoesGarageProductionsLLC  Před 7 dny

      Great question! The instructions were wrong. I emailed Senville and they confirmed it is capped at the factory and the manual is wrong.

  • @enviedminer6084
    @enviedminer6084 Před 14 dny

    So I just purchased a 24k BTU ductlessaire unit and wanted to ask if doing the 30amp disconnect and dual 30amp in the breaker panel is correct? The manual doesn't tell you what size to use for fusing at all.

    • @JoesGarageProductionsLLC
      @JoesGarageProductionsLLC  Před 7 dny

      You should see a "min fuse" rating in the manual or on the unit. Off the top of my head, 30 A is probably fine for a 24k but unit though, but definitely verify

  • @gregmiller2494
    @gregmiller2494 Před 6 dny

    Did the mounting brackets come with the unit?

  • @juancarlosm2033
    @juancarlosm2033 Před měsícem

    Hello, I just bought that unit yesterday, but I think I made a bad connection or something. and when I turned it on after an hour it started leaking inside 😩 any recommendations? Thank you..

    • @JoesGarageProductionsLLC
      @JoesGarageProductionsLLC  Před měsícem

      I assume you mean leaking water, correct? Make sure the drain line is sloped properly since water only flows downhill. I could see the joint in the drain line leaking if not properly sealed as well. If I recall I think I ran a lot of electrical tape around the joint on mine

  • @dbc105
    @dbc105 Před 6 měsíci

    Nice job, I have a few questions, where did you get nitrogen? is it expensive? Also, why did you go with Senville? I'm looking at a 12k BTU Leto for my bedroom and just wanted to hear other people's reasons for picking Senville. Thanks.

    • @JoesGarageProductionsLLC
      @JoesGarageProductionsLLC  Před 5 měsíci

      I got my nitrogen bottle from a local welding gas supply house. You should be able to get it anywhere they sell compressed gases. This unit was on sale when I purchased it and it appears to be made by Midea, like most of the other units in this class. It has proved to be a solid unit so far - no issues other than the remote control not playing nice with Wi-Fi/Alexa control. I am getting more and more fed up with Alexa anyway so I just use the remote.

  • @thomasmastrocinque7132
    @thomasmastrocinque7132 Před 2 měsíci

    Hi. Great Video. I have a small 1.5 car garage (~400 sq ft) I'd love to cool. Can you recommend a unit that is super-easy to install that runs on a 110 v AC outlet (instead of being hard-wired)? My budget is $1500.00 but I'd love to be closer to $1000.00 or less.

    • @JoesGarageProductionsLLC
      @JoesGarageProductionsLLC  Před 8 hodinami

      I don't know of any mini-split units that simply plug into a wall outlet. You might be better off with a permanently installed wall unit (installs into opening in wall, instead of a window).

  • @alejandrocarrillo373
    @alejandrocarrillo373 Před měsícem

    How many sq.ft is your garage.
    I have a 21x20 garage. Not sure what size to get. 12k or 18k. During the summer it always gets above 100f.
    Size wise it says 12k, but if I bring in a hot car, or garage opens. I’ll let the extra size to get back down to temp.

    • @JoesGarageProductionsLLC
      @JoesGarageProductionsLLC  Před 8 hodinami

      I would definitely suggest a 1.5 or 2 ton. Keep in mind your garage is probably poorly insulated and may, as you pointed out, contain hot equipment. My 1.5 ton / 18k BTU will bring my ~500 sq ft garage in south Florida from the high 80s/low 90s into the 70s in about 15 mins or so. I've gotten the garage as cold as 68 degrees in July/August, but that is on "turbo" mode.

  • @WoodWize54
    @WoodWize54 Před měsícem

    Joe, I have a simple question. Watched the video yesterday. I had a 24,000 BTU installed this spring in my workshop. Works great, except I can't figure out why the air handler never shuts off? Is it supposed to run constantly. I can't find a setting for that in the manual. I'm old so maybe doing something wrong LOL
    Thanks in advance

    • @JoesGarageProductionsLLC
      @JoesGarageProductionsLLC  Před měsícem

      It's funny you say that. I noticed the same thing with mine but have not tried to look into it. It is kind of annoying I agree

    • @WoodWize54
      @WoodWize54 Před 26 dny

      @@JoesGarageProductionsLLC I've looked thru the manual, but may have missed something about it. Thanks, If you find it first let me know.

    • @yaxlu
      @yaxlu Před 14 dny

      @@WoodWize54 Yes, these things are designed to run continuously with variable speed inverter motors. Just let to do its thing and once the set temperature is reached, it just tops off the recirculated air. As long as you don't stick your head at the exit of airhandler, it shouldn't matter at all. I have MrCool and that thing is so quiet, I have to check several times when I installed if that thing is even working but now after 1yr, I frown at friends houses when their central AC turns with blowers.

    • @WoodWize54
      @WoodWize54 Před 13 dny

      @@yaxlu Thanks for the reply. Yes very quiet. I put a pc of painters tape on it to see if it's running.

  • @jimbo8743
    @jimbo8743 Před 2 měsíci

    How is your electric bill after you have installed this mini split?

    • @JoesGarageProductionsLLC
      @JoesGarageProductionsLLC  Před 8 hodinami +1

      Honestly have not noticed it go up at all. Installing a hybrid water heater dropped the bill by so much, I don't even notice this mini split on the bill

  • @SolarPV.
    @SolarPV. Před 9 měsíci

    What happened to your heat pump stuff ? - I think it was you ...

    • @JoesGarageProductionsLLC
      @JoesGarageProductionsLLC  Před 9 měsíci

      Sorry, probably not me - not much need for heat in South Florida :)

    • @SolarPV.
      @SolarPV. Před 9 měsíci

      I just remembered someone messing with heat pumps in a garage. I think it was air to water for hot water. @@JoesGarageProductionsLLC

    • @JoesGarageProductionsLLC
      @JoesGarageProductionsLLC  Před 9 měsíci +1

      @@SolarPV. Ah ok gotcha. Yeah that wasn't me. I did do a video of a heat pump water heater a while back.