Ox Box Washer Hookup | Laundry Room
Vložit
- čas přidán 14. 09. 2020
- Showing you install for one of the laundry rooms in this build. We will end up with 3 hookups- canning kitchen, master closet, + second floor. Pretty easy install, let me know in the comments if you have questions!
Check out our Amazon store for items mentioned in this video:
www.amazon.com/shop/marshallr...
Daily Updates
Instagram / marshallremodel
Facebook / marshallremodel
Email | Website
info@marshallremodel.com
www.marshallremodel.com
Watch Next
• Plumbing
Music Licensing through Soundstripe
soundstripe.com?fpr=marshall10
Use code Marshall10 for 10% off your subscription!
#postframe #selfbuild #plumbing
You made a double trap (against code)by glueing the trap straight onto the venting joint. You MUST install a straight pipe between the trap and the venting pipe ( pipe length: atleast twice the diameter of the trap.)
I really like that split box system. Makes for a much cleaner look.
Looking forward to seeing the washer and dryer installed, thanks for sharing! 😊👍💕💕💕
Hey Paul, you know, it might be worth explaining to people what the purpose of plumbing vents are. Most people think it's to 'vent' the stink of the pipe contents and don't know that it's to aid the flow of fluids within the pipes. I once used a drinking straw to demonstrate to my wife - dip it in water and block end with your thumb and the contents won't flow but as soon as you open up the other end of the straw and provide the 'vent' the contents run out. You'd be surprised how many people don't know this.
Thank you for sharing and explaining your logic and insights.
Great coverage of mounting.
Great job fixing to do this to my house. Your right lots more room in a 2x6 wall
HI Paul, I found your channel over the weekend while looking up info on under-slab plumbing, and it was so informative and so well done I went back and watched the whole playlist from episode 1 to present. Looking forward to following along with your build! God bless!
Stand pipe must be 2’ minimum
Install some metal drywall flat plates to protect your piping from drywall nails and baseboard trim nails. It becomes a nightmare if you get a nail through your piping and develop a slow leak. Great job!
After watching your video, I realized that it is not going to work for me (LOL), having all the PVC pipes between two 16 O.C. studs. FL requires a little distance (a short PVC piece, 2x the pipe diameter) between the p-trap and the sanitary-T.
Great video. So simple with pex. They use hidrobronce here in Argentina, soldered with silver bar
I know Marshall that you will give us a smile one day: LOL
Enjoying the show
Something I've seen people do to address water-hammer, even in high end homes, is to just loop the PEX on itself in the wall, but leave the loop unsecured so that it can flex and absorb the shock. No extra parts or connections, just 3 extra feet of PEX.
I was hoping you take a outside shot 😊so we can see how the grass is doing.
36 from the ground thanks needed that info
Great work
This creates a S trap and can cause siphon. It's required to have some space between trap and san T. Space depending on the size and there is a table. I also have limited space between studs and I'm trying to find a solution.
The framer framed it wrong 😂