Plumbing Code Violations (Part 1)

Sdílet
Vložit
  • čas přidán 19. 11. 2021
  • I'm back at it again with more Code Violations. This time I delve into the wonderful world of Plumbing. Watch, listen, and learn as I take you on a Plumbing Code Violation Voyage.
    amzn.to/3XRat2H (2018 International Plumbing Code)

Komentáře • 519

  • @nobleroofinggeneralcontrac7961

    I learned a lot of new codes I was unware of. Great how you scroll the IPC up on the screen. Very thorough thank you.

    • @PPG1967
      @PPG1967  Před rokem

      I appreciate your feedback, and thanks for watching.

  • @veronicaolsen4292
    @veronicaolsen4292 Před rokem +4

    You seriously have taught me so much. And probably saved me thousands. Thank you!

    • @PPG1967
      @PPG1967  Před rokem +1

      I appreciate you saying that...thanks for watching!!

  • @randyriggs5463
    @randyriggs5463 Před rokem +8

    I just found your channel. Glad to see an instructor who really cares about code. Thank you. More videos please!

    • @PPG1967
      @PPG1967  Před rokem +3

      More to come!...I appreciate you watching.

    • @randyriggs5463
      @randyriggs5463 Před rokem +1

      @@PPG1967 I really enjoy applying code on my job. It's refreshing to hear someone actually using it. Thank you!

    • @jogme
      @jogme Před 5 měsíci

      Like any rule or law there are always exceptions and doesn’t mean a real problem

  • @markbosnick8006
    @markbosnick8006 Před 3 měsíci +3

    On the first tankless water heater, you can vent less than 2’ with a particular cap on the outside. The way they have it is wrong because the intake would be sucking in the exhaust. On the water piping in the basement, that’s the worst plumbing job I’ve ever seen. Those lines should be either ran in an area where there may be a bulkhead or up in the joists. Suppose the homeowner wants to finish that basement at some point. Now on the sump pump, I’ve never heard of venting a sump pump crock, only a sewage ejector crock. Loved the video.

    • @PPG1967
      @PPG1967  Před 3 měsíci

      Where are you located?…what code book are you referencing?

  • @scottzeiger459
    @scottzeiger459 Před 2 lety +1

    Excellent videos, and excellent addition of the pictures showing the proper device that could be installed the resolved issue.

    • @PPG1967
      @PPG1967  Před 2 lety +1

      I appreciate your feedback... thanks for watching!!!

  • @ellkir1521
    @ellkir1521 Před 8 měsíci +10

    Outstanding job. Thank you. Washington State just put me out of business as a small General Contractor since I can-not by law sub-contract my Plumbing or Electrical. I didn't even know about the law as no else did either since they passed it while the shut downs. I received a 1500.00 fine just for having lighting and plumbing in my keywords (not my service directory-just key words off internet to bring people to the website). I used to do bathrooms and kitchens but now I'll have to switch to spec homes. The only contractors that can afford a Administrative plumber and Electritian are the big box and unions. Legislatures go with whoever has the money-nothing new in Wa.

    • @PPG1967
      @PPG1967  Před 8 měsíci +2

      Wow...interesting. I hope everything works out.

    • @PPG1967
      @PPG1967  Před 8 měsíci +1

      I appreciate your feedback.

    • @Californians_go_home
      @Californians_go_home Před 8 měsíci +8

      Please clarify what you mean by you can not sub contract your plumbing and electrical. General contractors hire sub contractors. You must mean, you were doing plumbing and electrical yourself, or your keywords led people to believe you were licensed to do it.

    • @antman7431
      @antman7431 Před 5 měsíci +1

      ​@@Californians_go_home exactly what I was thinking lol. I'm an employee of a general contractor for remodeling in western NY, and normally people choose general contractors because they act as the intermediary for all of the different trades that need to come in to do work

  • @tonybrown4716
    @tonybrown4716 Před 2 lety +17

    2 minutes in already, paused just to say thank you and i appreciate what your doing, Im the type of person who really learns from others mistakes. I really want to my builds to be quality and per code specifications. 'Pure Heat your dropping.
    Manners and Respect

    • @PPG1967
      @PPG1967  Před 2 lety +1

      I appreciate your feedback. I got a lot of videos coming, I just need to find the time to edit them...thanks for watching!!

  • @michaelstonebridge8741
    @michaelstonebridge8741 Před 2 lety +3

    Thank you for these videos, they are very informative and as an apprentice plumber very helpful

    • @PPG1967
      @PPG1967  Před 2 lety +1

      I appreciate your feedback... thanks for watching!!

  • @richardhoner7842
    @richardhoner7842 Před 8 měsíci +1

    As always, very instructive. I love to learn!

    • @PPG1967
      @PPG1967  Před 8 měsíci

      I appreciate your feedback, and thanks for watching!!

  • @kevinritchie9227
    @kevinritchie9227 Před 2 lety +28

    Just found your channel. As an electrician, I know a lot of those type violations. As for the building/construction/plumbing ones, I never thought there are so many rules. I learned a lot. I can see the tradesman see you walk up to a new building thinking..."oh noooo it's Renaldo...were in trouble." lol

    • @PPG1967
      @PPG1967  Před 2 lety +2

      I appreciate your feedback... thanks for watching!!

    • @djhead2421
      @djhead2421 Před rokem +1

      @Kernica1 Then why can't we use Romex?

    • @str8dollarsigns
      @str8dollarsigns Před rokem

      and he responds, "Yup violations everywhere already...its in your face"

  • @larrytheplumber9851
    @larrytheplumber9851 Před 2 lety

    Love it can't get enough of these heaters

  • @PNWNature
    @PNWNature Před 2 lety

    Hey thank you for the post. Especially appreciated the part about having water hammer arresters for washing machines that is something I didn't know.

    • @PPG1967
      @PPG1967  Před 2 lety +1

      I appreciate your feedback...thanks for watching!!

  • @diep821
    @diep821 Před rokem

    Just came across your post, I love it.

    • @PPG1967
      @PPG1967  Před rokem

      I appreciate your feedback.

  • @javiervazquez9472
    @javiervazquez9472 Před rokem +4

    Plumber here in California. We use the CPC or California Plumbing Code 2019. It's just the UPC (Uniform Plumbing Code) but with its own little twists on things.
    UPC requires strapping for expansion tank (608.3), earthquake straps (507.2), smitty pan (507.5), and the pex cannot tie into the water heater for the first 18 inches. Needs to be copper (604.13). Also, the piping for the water heater's t&p needs to go to an approved location. Can be outside or to a floor sink. Just cant drain to the floor and cause damages. Same thing with the smitty pan (608.5).
    If I remember correctly, tankless can draw air from the inside, but it needs to have enough room. Its figured out using a formula found in the book (506.2.2). It is important to check the manufacturer's install instructions cause depending on the location, you may need to get air from the outside anyways or purchase a special filter made for those applications.
    Also, PEX is the only plastic allowed to be tested by air due to how well it expands. PVC will shatter with air (it's not pretty, I've seen it.) (609.4) PEX is in the exceptions below the code.
    UPC is the only code that allows the vents to be level at minimum (905.1) (unless it is below the flood level (6" above the highest plumbing fixture)) at which case it is treated as a drain until its above that level. (905.3)
    Im not 100% sure you can use pex as the dischaege piping for the relief valve.
    Both of our codes share the fact the hot water needs to be insulated (609.11) and a few others.
    Dishwasher drain hose needs to connect into an air gap befor discharging into drain. (807.3)
    Lastly, our code doesnt allow air admittance valves. So cant comment on the last part, looks interesting, Though.
    Here is a online version of our book.
    epubs.iapmo.org/2018/UPCITM/#p=1

    • @PPG1967
      @PPG1967  Před rokem

      I appreciate the info, and thanks for watching!!

  • @user-zo9rx1bb3v
    @user-zo9rx1bb3v Před 3 měsíci

    You really a sharp plumbing inspector, good up the excellent job you're doing. Lot of plumber's today just don't care about work manship.

  • @kileonamanzano7024
    @kileonamanzano7024 Před rokem +2

    I'm a commercial plumbing apprentice. 3rd yr. Plumbing for 6. On and off union 32 and 26. I find residential, having workrd it in the past, a totally different world. Not just the wood studs

    • @PPG1967
      @PPG1967  Před rokem

      Ok, I appreciate your commenting.

  • @dannmann17
    @dannmann17 Před rokem

    I just subscribed to your channel. I can learn a lot from you, stuff I never knew
    👍🏻🇺🇸

    • @PPG1967
      @PPG1967  Před rokem

      I appreciate your feedback. Welcome aboard.

  • @leftylou6070
    @leftylou6070 Před 6 měsíci

    Hey man! You only need to know three things to be a plumber. They are 1. Poop don't flow up hill. 2. Friday is payday. 3. The boss is a SOB! Learn it, love it, and use it!

    • @PPG1967
      @PPG1967  Před 6 měsíci

      I appreciate your feedback, and thanks for watching!!

  • @johnnichols2710
    @johnnichols2710 Před rokem

    Great video. Keep them coming

    • @PPG1967
      @PPG1967  Před rokem

      I appreciate your feedback.

  • @waltercortese9946
    @waltercortese9946 Před 2 lety +3

    Good video!! I assume part 2 is going to be released soon. How common are violations dealing with drilling studs and joists in your area?

    • @PPG1967
      @PPG1967  Před 2 lety +2

      I deal with those type of violations all of the time...thanks for watching!!

  • @brandothemando7140
    @brandothemando7140 Před 2 lety +11

    In the Oregon plumbing specialty code you're allowed to "flat vent" vent lines per 905.1

    • @PPG1967
      @PPG1967  Před 2 lety +1

      Oh ok...what Plumbing Code are you using??

    • @brandothemando7140
      @brandothemando7140 Před 2 lety +3

      @@PPG1967 it's basically the UPC

    • @ventrue33
      @ventrue33 Před 2 lety +6

      Here in NC, venting for gas tankless water heaters must be no less than 12” apart. You can utilize internal air as long as you have the correct cubic sq ft for the btu. Also the thermal expansion tank can be mounted on “rigid” pipe, such as copper.

    • @hardworkingamericanplumbin1182
      @hardworkingamericanplumbin1182 Před 11 měsíci

      God I want a plumbe in New York it’s basically the exact same as San Francisco Plumbing well how it used to be like anyways now they’re starting to use plastics and things of that nature that it was all cast-iron and it was all real Plumbing and everything was tight in right God I want a Plumbing New York

    • @zerovalue5106
      @zerovalue5106 Před 11 měsíci

      They also prop up pipes on loose wood chocks with plastic band iron straps. 😂

  • @CharlieT-vf7lu
    @CharlieT-vf7lu Před 5 měsíci

    Excellent eye, spot on, good video.

    • @PPG1967
      @PPG1967  Před 5 měsíci

      I appreciate your feedback, and thanks for watching.

  • @thunderds
    @thunderds Před 2 lety

    Thanks, great job, very informative.

    • @PPG1967
      @PPG1967  Před rokem

      I appreciate your feedback...thanks for watching!!

  • @RH-cv1rg
    @RH-cv1rg Před 5 měsíci +1

    I think the water hammer arrester might vary by State/Local depending on if they adopted the entire Plumbing Code.
    I just looked up the plumbing code for California and it doesn't look like they require arresters, I'm not an expert so you should check with your local building department. Here is the CA Code:
    609.10 Water Hammer
    [Not adopted by HCD] Building water supply systems where quick-acting valves are installed shall be provided with water hammer arrester(s) to absorb high pressures resulting from the quick closing of these valves. Water hammer arresters shall be approved mechanical devices in accordance with ASSE 1010 or PDIWH 201 and shall be installed as close as possible to quick-acting valves. HCD is Housing and Community Development.

    • @sdrtech
      @sdrtech Před 5 měsíci

      You are correct in most states the expansion tank is sufficient

  • @Herrooooooorara
    @Herrooooooorara Před rokem

    Glad I came across this!

    • @PPG1967
      @PPG1967  Před rokem

      Welcome... I appreciate you watching!!

  • @djlazzie
    @djlazzie Před 2 lety

    Thank you and keep up the great videos

    • @PPG1967
      @PPG1967  Před 2 lety +1

      I appreciate that... stay tuned, more to come.

  • @plumbbuild6517
    @plumbbuild6517 Před 2 lety +5

    I noticed that the dish washer that hooked up to the garbage disposal didn't have a high loop either 😅
    Thanks for sharing this video and please keep them coming.

    • @PPG1967
      @PPG1967  Před 2 lety +2

      I appreciate your feedback, thanks for watching!!

    • @BlueDart1971
      @BlueDart1971 Před rokem

      Dishwashers have a high loop installed on the side of the dishwasher so the one under the sink is not really necessary but I always looped them up just to keep as much stagnant water out of the line as possible. Realistically there should be an air gap on top of the sink but that’s one code that most inspectors realize is stupid.

    • @plumbbuild6517
      @plumbbuild6517 Před rokem +1

      @@BlueDart1971 your right there’s a high loop on the side of the dishwasher, inspectors in my county will fail one every time if you don’t have a secondary high loop. But you are right my friend. Have a good work week.

    • @BlueDart1971
      @BlueDart1971 Před rokem

      @@plumbbuild6517 my work week doesn’t involve plumbing very often anymore. It involves renters paying me:) After 30+ years of plumbing my body is shot. To all of you that work your butt off every day make sure you take care of your body.

    • @thomasbonse
      @thomasbonse Před 9 měsíci

      Hmm, where I'm located, you'd need an air-gap, not just a high-loop. Though I do understand that not every AHJ has implemented or enforces this requirement.

  • @andrewfarran1
    @andrewfarran1 Před rokem +3

    1:36 Think you missed a violation here. PEX piping cannot be directly tied into a water heater, 18" minimum. This is why they make flexible water heater supplies at 18" long

    • @PPG1967
      @PPG1967  Před rokem

      It's in the video sir... all code references are out of the 2018 IPC, International Plumbing Code. Not the Uniform Plumbing Code (UPC)...two different code books.

    • @PPG1967
      @PPG1967  Před rokem

      I appreciate your comment.

  • @jeremygibbs8659
    @jeremygibbs8659 Před rokem +1

    thank you for taking the time to make these videos, I have really enjoyed them. I have one question. In the 2018 IPC on page ix under effective use of the international plumbing code it states, The IPC is a model code that regulates the design and the installation of plumbing systems including the plumbing fixtures in all types of buildings except for detached one and two-family dwellings and town houses that are not more than 3 stories above grade in height. In the videos you reference the IPC so is the unit you're inspecting multi-family? I'm just trying to make sure I am referencing the right code book for the right application. thank you.

    • @PPG1967
      @PPG1967  Před rokem +2

      The codes in the IRC are straight out of the IPC. For example, in the video, I referenced section 409.4 in the IPC, which is in the IRC at P2717.2. I also referenced section 312.5 in the video, which is in the IRC at P2503.7.

    • @jeremygibbs8659
      @jeremygibbs8659 Před rokem

      @@PPG1967 thank you for clarifying that.

  • @salvatoremaniaci230
    @salvatoremaniaci230 Před rokem +1

    For the insulation of the hot water pipes if they were ram through the joists with the insulation that’s existing would that make code or regardless you have to insulate the pipe

    • @PPG1967
      @PPG1967  Před rokem

      Ok, I appreciate your feedback

  • @jacksami777
    @jacksami777 Před 4 měsíci

    As much I hate the codes same time I appreciate your help and explanation

  • @AbouTto_
    @AbouTto_ Před rokem +1

    Great video.

    • @PPG1967
      @PPG1967  Před rokem +1

      I appreciate your feedback.

  • @sunman4291
    @sunman4291 Před 4 měsíci

    Great job 👍🏿

    • @PPG1967
      @PPG1967  Před 3 měsíci +1

      I appreciate you watching!!

  • @ignacioanaya3403
    @ignacioanaya3403 Před 6 měsíci

    Great video, thank you for share

    • @PPG1967
      @PPG1967  Před 6 měsíci

      I appreciate you watching!!

  • @williamquigley5836
    @williamquigley5836 Před 7 měsíci

    very informative. Thank you.

    • @PPG1967
      @PPG1967  Před 7 měsíci

      I appreciate your feedback, and thanks for watching.

  • @ifixditpd6391
    @ifixditpd6391 Před 2 lety

    Good job on making this video.👍

    • @PPG1967
      @PPG1967  Před 2 lety

      I appreciate you saying that... thanks for watching!!

  • @BigfootGoforth
    @BigfootGoforth Před 5 měsíci

    Thank you for the useful information

    • @PPG1967
      @PPG1967  Před 5 měsíci

      I appreciate your feedback, and thanks for watching.

    • @BigfootGoforth
      @BigfootGoforth Před 5 měsíci

      @@PPG1967 I was a handyman for about 15 years. You cannot imagine the amount of fuckery the 20 years of homeowners doing plumbing repairs and electrical repairs under a sink can lead to lol.
      Yeah switch out the faucet should be you know half an hour 45 minutes tops. 6 hours in with a Dremel tool ...
      Save the sink!!!.
      Are having a six-way gang box with six extension cords under the sink holes drilled into the cabinet bases to run the extension cords to the outside through a cat door and to the inside because it was an old house..." I don't know why it keeps popping but I'm tired of it...

  • @waynegomillion4976
    @waynegomillion4976 Před 2 lety +1

    Appreciate it. How are violations handled? Does work have to stop are there fines given?

    • @PPG1967
      @PPG1967  Před 2 lety +3

      The violations must be corrected before they can schedule a re-inspection. Typically the jurisdiction will charge a fee ($50) that must be paid before they can rescheduled.

  • @danieldawson222
    @danieldawson222 Před rokem +2

    As a plumber with over 40yrs of hands on
    Experience and a fair hand at most of the other trades, my experience with most inspectors is the first thing they will look at the cleanliness and quality of your work, and a clean job site doesn't hurt either.

    • @PPG1967
      @PPG1967  Před rokem +1

      Ok, I appreciate your comment.

  • @masterp12010
    @masterp12010 Před 2 měsíci

    On the end of the video regarding the sump pump that’s tied into the drainage system here in Colorado that’s illegal. Where are you located? Also, but at some pump here in Colorado event is not required only on a sewage ejection.

    • @PPG1967
      @PPG1967  Před 2 měsíci

      I'm in Georgia. We use the IPC (International Plumbing Code)

  • @richardblake8153
    @richardblake8153 Před 2 lety

    Thanks for this video

    • @PPG1967
      @PPG1967  Před 2 lety

      I appreciate your feedback. Thanks for watching!!

  • @781coolmind
    @781coolmind Před 5 měsíci +1

    Good video.

  • @pmgolf5305
    @pmgolf5305 Před rokem

    Very informative Video , Does this apply to all states , or The state your current located , If so whitch state ?

    • @PPG1967
      @PPG1967  Před rokem

      So, it's whatever state has adopted the 2018 IPC (International Plumbing Code)

  • @robchurchill1368
    @robchurchill1368 Před 11 měsíci

    great channel and content. thanks!!!!!! SUBSCRIBED!

    • @PPG1967
      @PPG1967  Před 11 měsíci

      Thanks for the sub!

  • @MacMilly707
    @MacMilly707 Před rokem +1

    Jus found your channel. Great contact 👍

    • @PPG1967
      @PPG1967  Před rokem

      I appreciate your feedback...thanks for watching!!

  • @jackalbatross9486
    @jackalbatross9486 Před 5 měsíci

    great video

    • @PPG1967
      @PPG1967  Před 5 měsíci +1

      I appreciate you watching!!

  • @ptech88
    @ptech88 Před 6 měsíci

    You are half right on some thing, venting of tankless water heaters need to be approved exhaust pipe. Pvc is not allowed for exhaust. Pex pipe has to be 24 inches from top of heater. Intake air can come from basement as long as there is enough square feet per btu. Never heard of water test for pex water lines, if it holds air it will hold water.

    • @PPG1967
      @PPG1967  Před 6 měsíci

      What code book are you referencing???...my videos based on the IRC or IPC.

  • @lynnetteb4784
    @lynnetteb4784 Před 6 měsíci

    I think you are adorable and I love listening to you talk code violations ❤

    • @PPG1967
      @PPG1967  Před 6 měsíci

      I appreciate you saying that....thanks for watching!!

  • @robertemoryjr6
    @robertemoryjr6 Před 4 měsíci

    I believed fresh air Intake doesn’t have to be outside if there is enough combustible air in the room installed? Is that not true it does actually list it in the manual for Navien Tankless units. But if that code changed that would be huge to know for sure?

  • @andrewengland971
    @andrewengland971 Před 2 lety +2

    Was the relief drain on that water heater in 1 inch pex? By code the relief has to be 1 inch pex or 3/4 copper.

    • @PPG1967
      @PPG1967  Před 2 lety

      I think was 3/4"...I think code says it must be 3/4"

    • @PPG1967
      @PPG1967  Před 2 lety

      I appreciate your comment..thanks for watching!!

  • @Alphasig336
    @Alphasig336 Před rokem +1

    Air will leak before water would leak. Air molecules are much smaller than water molecules. Do what code says for your area, but physics says if it hold air at pressure X it will not leak with water

    • @PPG1967
      @PPG1967  Před rokem +1

      Well, it's easier to determine where a leak is coming from with water.

    • @PPG1967
      @PPG1967  Před rokem +1

      I appreciate your feedback, and thanks for watching!!

    • @mrcryptozoic817
      @mrcryptozoic817 Před 5 měsíci

      (Not a plumber) but a slow air leak is harder to detect than a seep. Gauges just aren't that accurate. (IMO)

  • @carmenalmanzar2205
    @carmenalmanzar2205 Před 2 lety +2

    Hi. I am new to your channel. Is this applicable nationally. I would think. I always thought that municipality are to protect the consumer but I don’t know where to go any more.

    • @PPG1967
      @PPG1967  Před 2 lety

      So, my videos are based on ICC Code Books. That video references the 2018 IPC (International Plumbing Code). Check to see if your city or state has adopted this Code Book.

    • @PPG1967
      @PPG1967  Před 2 lety +1

      Remember Code is Law!!

    • @PPG1967
      @PPG1967  Před 2 lety

      Thanks for watching!!

  • @minimonkeyplay
    @minimonkeyplay Před 5 měsíci

    according to the UPC Exception: For PEX piping systems, testing with a compressed gas shall be an alternative to hydrostatic testing where compressed air or other gas pressure testing is specifically authorized by the manufacturer’s instructions for the PEX pipe and fittings products installed at the time the system is being tested, and compressed air or other gas testing is not otherwise prohibited by applicable codes, laws or regulations outside of this code. UPC and IPC are fighting each other on this code.

    • @PPG1967
      @PPG1967  Před 5 měsíci

      I appreciate your feedback, and thanks for watching.

  • @JEFFREYHAUGAN
    @JEFFREYHAUGAN Před 4 měsíci

    Just a reminder, these codes are either statewide or city wide. What is a violation here may well not be a violation someplace else. you have to know what the jurisdiction you are in requires, and sometimes that even goes by individual inspectors which is really a pain!

    • @PPG1967
      @PPG1967  Před 4 měsíci

      It's about what codes your state has adopted. This video may not apply to every area.

  • @mikebarbieri4151
    @mikebarbieri4151 Před 5 měsíci

    In my area air gap is required and flat vent is ok 6 in above the flood rim.

    • @PPG1967
      @PPG1967  Před 5 měsíci

      Let me guess, the UPC???

  • @joshuacassino7297
    @joshuacassino7297 Před 2 lety +1

    Two questions. Does the trade have to be there for the inspection also do you tell them exactly what needs to be done?

    • @PPG1967
      @PPG1967  Před 2 lety +2

      No, the trade does not have to be there. It's to their advantage to be present at the inspection, so they can fully understand any violations. I normally email the results.

    • @joshuacassino7297
      @joshuacassino7297 Před 2 lety +1

      @@PPG1967 in your emailing or any inspectors, do they say exactly what’s wrong and what to satisfy?

    • @PPG1967
      @PPG1967  Před 2 lety +1

      @@joshuacassino7297 yes

  • @MrTay675
    @MrTay675 Před rokem

    good starting point is to find out if your state is based on UPC or IPC

    • @PPG1967
      @PPG1967  Před rokem

      That's true...I appreciate your feedback.

  • @xl000
    @xl000 Před 10 měsíci

    This is why you install a decoy plumbing that's up to code but not actually used by anything, and hide the actual plumbing behind drywall and secret doors.
    If it can't be checked for violation, it's not a violation

    • @PPG1967
      @PPG1967  Před 10 měsíci

      You're a genius..

  • @adamrutledge4031
    @adamrutledge4031 Před 2 lety +1

    2018 UPC section 905.1 states that vent pipes can be level or graded. Also see figure 905.1

    • @PPG1967
      @PPG1967  Před 2 lety +1

      So, my videos... and I've stated this a million times, only reference the 2018 IPC (International Plumbing Code) not the UPC (Uniform Plumbing Code). I live in Georgia, the I.C.C. Code Books are the ones we've adopted.

    • @PPG1967
      @PPG1967  Před 2 lety

      You guys kill me.. you watch my videos to find something inaccurate, instead of taking this opportunity to learn something new...nice try sir 😅

  • @condor5635
    @condor5635 Před 5 měsíci

    PEX can’t be that close to water heater right? It wasn’t done in this case, but is a valve on the hot water side of a water heater against code?

    • @PPG1967
      @PPG1967  Před 5 měsíci

      These videos are based on the IPC, not the UPC.

  • @nobleroofinggeneralcontrac7961

    If in a cold climate water testing supply plastic piping cold cause freeze ups. How could that be done in a cold climate?

    • @PPG1967
      @PPG1967  Před rokem

      We allow air to be used.

  • @jwblount7802
    @jwblount7802 Před 2 lety

    What is the code violation on the fresh air intake on the tankless water heater in the utility room? According to the manufacturer's installation if you have enough cubic inch of fresh air space per btus fresh air can be use from the inside of the house. Now that being said that particular brand may require it to come from outside but you stated it was a code violation. Which one?

    • @PPG1967
      @PPG1967  Před 2 lety

      Yes, the intake and exhaust must terminate on the exterior..per manufacturer's installation instructions.

    • @PPG1967
      @PPG1967  Před 2 lety

      I appreciate your comment.

    • @AndrewP210
      @AndrewP210 Před rokem

      @@PPG1967 yes 🙌🏾. Manufacturers specifications trump the code in some instances

  • @tonyplumbob
    @tonyplumbob Před 6 měsíci

    How do you know the air hammer arrestor is not in tha wall far for washing machine and the kitchen

    • @PPG1967
      @PPG1967  Před 6 měsíci

      They are normally installed at the washing machine box at the shut-off valve....they're visible.

  • @sstjacques
    @sstjacques Před rokem +1

    I had my HVAC vent my furnace out side by side intake and exhaust 1 feet from each other, when it got below 0 it would freeze the intake causing snow/ice blockage shutting off furnace that i had to clear in order to re-start furnace. Had to extend 3 feet away and angle exhaust outward not downward toward ground solved problem. I can see why venting tank-less water heater the same way, would cause similar problem i had.

    • @PPG1967
      @PPG1967  Před rokem

      Thanks for sharing...I appreciate you watching!!

    • @gregkeeyako
      @gregkeeyako Před rokem

      Me too. Got fed up and routed them 10 feet apart.

  • @awjkjk7777
    @awjkjk7777 Před rokem

    The one about testing the dwv by having the water to the highest fixture confuses me. Since the shower pan and the tub have different flood rims, wouldn’t it be impossible to have them both filled completely?

    • @PPG1967
      @PPG1967  Před rokem +2

      So, you just plug the shower drains and fill the bathtubs up to the overflow outlet. It's about making sure the sanitary lines are full of water.

    • @PPG1967
      @PPG1967  Před rokem

      Thanks for watching!!

  • @mrbig4532
    @mrbig4532 Před 2 lety +7

    This is what happens when you hire a builder who attempts to do all of the different trades by himself or believed his coke head brother in law when he told him he was a plumber years ago before he hurt his back on the job and is still waiting for his settlement even though he never filed a worker’s comp claim but still found a shady lawyer who is filing lawsuits against his former employer who was nothing more then a general contractor who hired this guy as a subcontractor and 1099ed his ass at the end of the year .

    • @PPG1967
      @PPG1967  Před 2 lety +1

      Ok, interesting comments.. thanks for watching !!

    • @mrbig4532
      @mrbig4532 Před 2 lety +2

      @@PPG1967 thanks I has just trolling a little bit but anyone who’s in the building trades knows someone who my original comment applies too. Whoever the Plumber was on this job wasn’t the target of my comment, I didn’t get to see enough of his work to criticize the final rough in part of the job.

    • @don2deliver
      @don2deliver Před 6 měsíci

      Oddly specific details.

  • @joshcowart2446
    @joshcowart2446 Před 2 lety +1

    He missed a couple. On the first heater they have pex tied directly to the heater. They also use pex for the pop off on both heaters. Even if they let you use pex, the first heater is crimp pex so the fittings reduce the size. You can’t have any pipe size reduction on a pop off.
    There’s several things he flagged that we’d be allowed to do. First is the vents, I know they need to be sloped but every inspector I’ve run into is usually fine with them being flat. The main thing is that there’s no belly’s that can hold water and cutoff the vent. Second is air test on pex. We air test everything unless we can do a live water test either one is fine.

    • @PPG1967
      @PPG1967  Před 2 lety

      So, what plumbing code book are you referencing sir???

    • @PPG1967
      @PPG1967  Před 2 lety

      That video is based on the 2018 International Plumbing Code (IPC).

    • @joshcowart2446
      @joshcowart2446 Před 2 lety +1

      I use both codes but I am more familiar with UPC. However the things I mentioned, I thought were in both codes. I stand corrected. They may be old codes that some plumbers/inspectors still follow. The only one I’ll still stand by is tank with crimp pex. It looked like 3/4. If so, it would be illegal because it has a smaller ID than the t&p valve does due to the fittings not being full port.
      As for the second paragraph, I didn’t mean to argue that that was codes but just what our local inspectors tend to allow whether or it’s legal per code.

    • @drewkoube
      @drewkoube Před 2 lety +1

      @@joshcowart2446 I thought they have to have at least 18” of hard pipe off the heaters too

    • @PPG1967
      @PPG1967  Před 2 lety

      No worries...thanks for watching!!

  • @williambrown7719
    @williambrown7719 Před 5 měsíci

    On the tankless, how come y’all don’t use I pex pipe?Secondary where is your copper 18 inches off the other water heater?And on the other tankless can you use the atmosphere air in the room? Vent can run flat besides the main vent by international code?you can’t trap sewer gas on a flat vent. most dishwashers have the loop built on the side of them look in the manufacturer book.

    • @PPG1967
      @PPG1967  Před 5 měsíci

      What code book are you referencing???....my videos are based on the IPC, not the UPC.

  • @chodge8366
    @chodge8366 Před rokem +2

    pex coming directly from a water heater is a fail in some areas. They want atleast 12” copper or metal braid around here

    • @PPG1967
      @PPG1967  Před rokem +1

      So, we use the IPC (International Plumbing Code) not the UPC.

    • @PPG1967
      @PPG1967  Před rokem +1

      I appreciate your feedback..thanks for watching!!

  • @vinnygoombatts1458
    @vinnygoombatts1458 Před 8 měsíci

    I can't believe a professional plumber did this. This is plumbing 101

    • @PPG1967
      @PPG1967  Před 8 měsíci +1

      Yes sir, he sure did.

  • @williamspencer6743
    @williamspencer6743 Před 2 lety

    On sump pumps you need to check with the manufacturer specifications first. Air admittance valves are allowed on many of these units. Read the installation manual. Personally I have not installed a unit that has allowed it. Zoeller or Little Giant.

    • @PPG1967
      @PPG1967  Před 2 lety

      So, you're saying they are not allowed ??

    • @williamspencer6743
      @williamspencer6743 Před 2 lety +1

      @@PPG1967 Correct, in short state and local code will require that the manufacture installation requirements be met on their product.

    • @williamspencer6743
      @williamspencer6743 Před 2 lety +1

      Also check the IPC 2021 code book section 918.8 Air admittance valves / prohibited installation. Air admittance valves shall not be used to vent sumps or tanks without engineers design.

    • @erbewayne6868
      @erbewayne6868 Před rokem

      What if the unit is discharged to the exterior of the house and does not connect to a plumbing system?

    • @thomasbonse
      @thomasbonse Před 9 měsíci

      ​@@PPG1967I'm not sure, but I believe this is related to the code changes implemented to require pre-fitting for radon mitigation during new build construction.

  • @ncooty
    @ncooty Před 5 měsíci +2

    Thanks. Suggestion: Drop the music or turn it down. Also, no need for the intro footage of random houses. Your commentary stands on its own. Again, thanks for posting.

    • @PPG1967
      @PPG1967  Před 5 měsíci

      I appreciate you watching.

  • @LearnPlumbing
    @LearnPlumbing Před 5 měsíci +1

    I wish our UPC would adopt the high loop.

    • @PPG1967
      @PPG1967  Před 5 měsíci

      I appreciate you watching!!

  • @diep821
    @diep821 Před rokem

    When i use my washing machine, the water drained and then it came up to the toilet bowl. Why? The water literally filled up the toilet bowl side. How come?

    • @PPG1967
      @PPG1967  Před rokem +2

      You probably should check with a competent plumbing contractor in your area.

  • @AbouTto_
    @AbouTto_ Před rokem +5

    No music needed. CZcams violation.

    • @PPG1967
      @PPG1967  Před rokem +1

      I agree in most cases.

  • @RandallKelsey
    @RandallKelsey Před rokem +1

    I’m glad your not around my area. Most of those were wrong/b.s.

    • @PPG1967
      @PPG1967  Před rokem +1

      All code related issues. You don't use code books in your area?

  • @jonmarsh1438
    @jonmarsh1438 Před 6 měsíci

    Thank you so much for posting. To help me more I would turn the background music way down or delete it as I found that the music blocked and interfered with your voice.

    • @PPG1967
      @PPG1967  Před 6 měsíci

      Ok, I appreciate your feedback.

  • @alecdeese8925
    @alecdeese8925 Před rokem +2

    Can you do more plumbing inspection videos please?

    • @PPG1967
      @PPG1967  Před rokem +2

      I got you...thanks for watching!!

  • @johnbeckwith1361
    @johnbeckwith1361 Před rokem +2

    Lots of juicy violations. Great video. 3:45 this dishwasher drain also didn't have a loop on it. Is this all the same house? It would seem the plumber knows how to go through the motion but doesn't understand the reason for all of the codes. That is what frustrates me the most when dealing with young hot headed contractors, they might know they have to do something a certain way but don't understand why. These types are the first to cut corners and do it wrong if its too hard or they aren't making money on the job. They aren't "tradesmen", just handymen trying to make an easy buck.

    • @PPG1967
      @PPG1967  Před rokem

      So, those were two different houses.

    • @PPG1967
      @PPG1967  Před rokem

      I appreciate your comment.

  • @OutOfPockets
    @OutOfPockets Před 8 měsíci

    On that heater, pex cannot connect within 18" of the tank. Gotta put some copper risers.

    • @PPG1967
      @PPG1967  Před 8 měsíci

      I appreciate your commenting, however this video is based on the IRC or IPC...not UPC

  • @cspill99
    @cspill99 Před 3 měsíci

    Can you replace a cast iron house trap with a pvc house trap in michigan?

    • @PPG1967
      @PPG1967  Před 3 měsíci

      Consult with a competent plumber in your state.

  • @mnielsen005
    @mnielsen005 Před 2 lety +1

    Not sure if it's part of the national plumbing code, but we can't go directly onto the water heater with PEX. Needs to have a minimum of 18" of non combustible material.

    • @PPG1967
      @PPG1967  Před 2 lety

      So, I've addressed this probably 5 or 6 times. My videos reference the International Code Books..IPC, IRC, IMC, IFGC..etc

    • @PPG1967
      @PPG1967  Před 2 lety +1

      That code that you're referring to is out of the Uniform or National Plumbing Code. I live in Georgia, we've adopted the IPC (International Plumbing Code)

    • @PPG1967
      @PPG1967  Před 2 lety

      Thanks for commenting.

  • @anthonyesparsen7776
    @anthonyesparsen7776 Před 2 lety

    good job inspector fine job

    • @PPG1967
      @PPG1967  Před 2 lety

      I'll appreciate you saying that!!!...thanks for watching!!

  • @neckofthewoods24
    @neckofthewoods24 Před 2 lety

    that first tankless i think you missed something. yes they are to close but the PVC piping has black letters. black letters should be foam core and not solid PVC like the red lettering is. if that pipes not solid PVC then its a violation and strictly against the manufacturers instructions. are black lettering and red lettering the same country wide??

    • @PPG1967
      @PPG1967  Před 2 lety

      Oh ok..I didn't know that. That's manufacturer's installation instructions?

    • @neckofthewoods24
      @neckofthewoods24 Před 2 lety

      @@PPG1967 I think everyone. It may be low heat but still to hot for foam core.

  • @condor5635
    @condor5635 Před 5 měsíci

    I have a 1960 home and it has no water hammer arresters anywhere. I’ve never had any issues….. no thermal expansion tank either… no issues wharsoever. That begs the question what’s the point?

    • @PPG1967
      @PPG1967  Před 5 měsíci

      Didn't era, didn't construction materials, didn't appliances sir.

  • @pondboggen
    @pondboggen Před 10 měsíci

    WOW WOW WOW!!! tankless hot water heater = the contractor actually painted the pvc sch 40 on the outside!! ya inlets/outlets are done wrong but watching 100 plus videos and it is so rare! to protect pvc sch 40 pipe that is not UV rated.

    • @PPG1967
      @PPG1967  Před 10 měsíci

      So, what code book are you referencing ??

    • @pondboggen
      @pondboggen Před 10 měsíci

      did manufactures change this recently for sch40 PVC pipe, including thin wall pipe?
      --electrical conduit is normally rated for UV (exposed to sun) but that is electrical conduit, not plumbing, for tankless water heaters that can and do use pvc pipe for inlet and outlet exhaust, PVC generally is not rated for UV or less special manufacture product for inlet/outlet that goes on outside of house (but not always rated for UV)
      --DWV (drain waste vent) is normally not rated for UV. sch80 PVC might be UV rated but doubtfull.
      --it should be in older codes 2015 maybe ealier?
      --DWV pipe only time it is normally installed is if it is burried or install in a wall, or floor, or ceiling were UV (sun light) does not come in direct contact with pipe. the rare times it does come in contact with sun is....
      ----sepetic tank field might have 2 to 4 pipe vents coming just to ground that might need some UV protection just above ground.(most folks will get a UV rated cap for like draining gutters into yard pop caps for septic tank vents *i do not remember specific name they are called*)
      ----the main DWV vent (residental) top of roof normally, but many times a proper roof flashing / vent is installed to keep water going back into home, and sch40 or thin wall pipe is not exposed to the UV (sun).
      ----then tankless water heaters is big trouble. not sure of latest manufacture install requirements, but they want inlet air and exhaust air to be out and away from home. THAT were issues come in. i do not know exact code but if it is a couple inches i think code begin requires the pvc to be protected. the couple inches just enough so when pvc pipe becomes yellish? brownish? vs new installed white and becomes brittle, the pvc pipe still **hopefully** a good solid connection to side of home so the brittleness is less of an issue. if it is longer than those couple inches from side of home then it requires protection. code states exact length / dimensions.
      --off top of head i don't remember spay can paint type (pickup pretty much any store that sales spray can paint) there is a heat rating though may need to check larger hardware store for higher heat for the exhaust vent for tankless hot water heater. (there is a heat rating going out the exhaust that needs to pay attention to, and you might end up in automotive spray can paint isle) some folks might scuff up outside of pipe some with sand paper to give a little extra catch for paint to hold onto.
      --other folks might use foam insulation (buy in a roll like tape), most hardware stores should have. that tape foam easier work with around fittings and pipe.
      ---the higher effencity furnaces that can use sch40 pvc pipe also has same issue of possibly needing to protect the pipe outside of home.
      --side note. CPVC (not pvc) generally is UV rated, it is used more times for pressure relief and heat relief pipe, and is rated for higher temps for portable water in home. and is more likely to be installed on (any given hot water heater) were there might be a window that lets sun in directly on the pipe. last thing you want is high heat water going bursting due to pipe becoming brittle due to UV rays of sun. but CPVC is water and made smaller diameter.

  • @nussyadler1099
    @nussyadler1099 Před rokem

    Hi I'm a plumber in Rockland county and I wanted to know how I can get a list or sheet of updated codes in my area

    • @PPG1967
      @PPG1967  Před rokem +1

      So, you should check with your local or city building department.

    • @PPG1967
      @PPG1967  Před rokem

      Thanks for watching!!

  • @BeeBombard
    @BeeBombard Před 9 měsíci

    Where I'm from, some of those would've passed. Also, most of those were not violations. You can air up pex pipe, you don't need vacuum breakers on outside faucets because you should be using frost free that have those already installed. Also, you don't need hammer arrestor unless the pressure is high and if it's high you should add a PRV valve. I would state in your videos that this where you are from not everybody else.

    • @PPG1967
      @PPG1967  Před 9 měsíci

      I always post what code book I'm referencing. International Code Books. If you use these books, my videos are applicable. My videos are based on the Code or manufacturer's installation instructions.

    • @PPG1967
      @PPG1967  Před 9 měsíci

      I appreciate your feedback, and thanks for watching

  • @swolneck8615
    @swolneck8615 Před rokem

    Can you tell me what page the expansion tank is on in the 2018 ipc

    • @PPG1967
      @PPG1967  Před rokem

      Section 607.3 2018 IPC

    • @PPG1967
      @PPG1967  Před rokem

      Section 308.10 2018 IPC

  • @flyer_andy2023
    @flyer_andy2023 Před 2 měsíci

    7:30 Are you sure the high loop isn’t correctly created on the dishwasher-side of the cabinet?

    • @PPG1967
      @PPG1967  Před 2 měsíci

      It's entering the kitchen cabinet very low. I'm pretty sure that the high loop is not on the dishwasher side.

  • @gladiatormechs5574
    @gladiatormechs5574 Před 2 lety

    can a permit inspection fail if your system is not vented, but still drains just fine without any smells ?

    • @PPG1967
      @PPG1967  Před 2 lety

      So, a sanitary system must be vented to drain effectively. How is it draining correctly and its not vented??

    • @PPG1967
      @PPG1967  Před 2 lety +2

      To answer your question, yes I would fail it.

    • @gladiatormechs5574
      @gladiatormechs5574 Před 2 lety +1

      @@PPG1967 i was told by a plumber that it is not vented, and i will need it to pass inspection for a permit.. But it drains just fine with no smells at all.. is their a code that if it is within a certain distance such as 6 feet that it does not need individual venting.. it has been working just fine for many years now... i heard about CHEATER VENTS..

    • @gladiatormechs5574
      @gladiatormechs5574 Před 2 lety

      @@PPG1967 watch this video on vented vrs non vented. czcams.com/video/4VkOsrHhjsI/video.html

    • @thomasbonse
      @thomasbonse Před 9 měsíci

      Not just vented, but all the vents tied together too.

  • @drchamp1902
    @drchamp1902 Před rokem

    Is installing a French drain in the basement requires a plumbing permit?

    • @PPG1967
      @PPG1967  Před rokem

      Check with your city or county building department.

  • @doombuggyc6628
    @doombuggyc6628 Před 6 měsíci

    From the looks of it, they probably hired a service plumber. New construction plumbing is a different animal.

    • @PPG1967
      @PPG1967  Před 6 měsíci

      Yes, it is...thanks for watching!!

  • @randomcamerajunk6977
    @randomcamerajunk6977 Před 2 lety

    Wow that's some rough plumbing

    • @PPG1967
      @PPG1967  Před 2 lety

      Thanks for your feedback!!

  • @vans_universe
    @vans_universe Před rokem

    It would be nice to cut to a propper picture of it done right and tools used

    • @PPG1967
      @PPG1967  Před rokem

      Sorry, you probably need to tune in to another channel for that. I appreciate you watching.

  • @itsraheem
    @itsraheem Před rokem

    Can you use pex A inside of property inside of chicago?

    • @PPG1967
      @PPG1967  Před rokem +1

      I don't understand your question.

    • @itsraheem
      @itsraheem Před rokem

      @@PPG1967 sorry for the confusion, I was wondering if pex is code in chicago and it isn’t.

    • @PPG1967
      @PPG1967  Před rokem

      Ok, I going to suggest checking with your local building department.

    • @PPG1967
      @PPG1967  Před rokem

      Thanks for watching!!!

  • @sku32956
    @sku32956 Před rokem +1

    That dishwasher code issue is real I have had a dishwasher blow out water from the sink because of the code issue he mentions .

    • @PPG1967
      @PPG1967  Před rokem

      I appreciate your comment...thanks for watching!!

    • @johnbeckwith1361
      @johnbeckwith1361 Před rokem +2

      If you don't loop the DW drain line then all that dirty water flows back into the DW and is mixed with your final fresh water rinse cycle.

  • @pipebykonrad-kayplumbingse5865

    I am not sure if someone already pointed this out, washing machine box where you talk about air vs water test, vent piping is not installed correctly. It is before p-trap, it should be after. I admire inspectors who try to actually now codes... Keep it up with good work.

    • @PPG1967
      @PPG1967  Před 2 lety +1

      Oh ok.. thanks for catching that.

    • @PPG1967
      @PPG1967  Před 2 lety +1

      Thanks for watching!!

    • @Faruk651
      @Faruk651 Před rokem +1

      Lol, that is not a vent you goose. The pvc pipe goes thru the 2x4 wall stud and there is a sanitary tee. Vent is going up behind the stud. At 6:43 mark you can see very small part of the white pvc vent going up along the wall stud by the bathtub. Who made you plumber? I am not even a plumber, haven't even glued two pieces of pipe in my life but i can figure it out.

    • @dmills13F
      @dmills13F Před rokem

      That was a 2nd standpipe, probably for AC condensate. Totally acceptable.

  • @larrytheplumber9851
    @larrytheplumber9851 Před 2 lety +1

    Water heater expansion tank and the fact the hot side straight pex....I thought u had to come off the tank with at lest 18 inches of copper before u can transition to other material ?

    • @PPG1967
      @PPG1967  Před 2 lety +1

      So, I live in Georgia. We use the IPC (International Plumbing Code). What you are referring to is in the UPC (Uniform Plumbing Code). I don't know or use the UPC.

    • @PPG1967
      @PPG1967  Před 2 lety

      Thanks for watching!!!

    • @larrytheplumber9851
      @larrytheplumber9851 Před 2 lety +1

      @@PPG1967 thxz

  • @michaelolson
    @michaelolson Před rokem

    How much Square feet for a room to have that intake , in the room and not lead outside ?

    • @PPG1967
      @PPG1967  Před rokem

      I'm sorry, I don't understand your question.

    • @thomasbonse
      @thomasbonse Před 9 měsíci

      That would depend on not only the the manufacturer's instructions for the instant hot water heater, but also the code and any amendments applicable in your jurisdiction. Generally, allowing for indoor intake is considered an exception rather than a permitted practice and the rules pertaining to allowing that exception may not be available in every situation. This can be due to other building requirements, such as those pertaining to insulation and building envelope tightness, in effect for the jurisdiction. IE a tight house may not produce enough make-up air to also supply the instant water heater intake requirements regardless of the room volume, resulting in a negative indoor pressure and back drafting. There can be other environmental, legal, or precautionary considerations otherwise incorporated into any local code amendments.
      If you plan to fight an inspector's red flag, you better be prepared with the relevant code including any amendments to back up your assertions. And be there with the inspector during the inspection as minor issues can potentially be resolved during the same inspection, saving time, money and an additional trip for the inspector (a win-win in my book).