Motor Driven Boiler Feed Pump (MDBFP)

Sdílet
Vložit
  • čas přidán 18. 02. 2024
  • Motor Driven Boiler Feed Pump (MDBFP)
    MDBFP
    • How MDBFP rapid start ...
    • How MDBFP rapid start ...
    Boiler Feed Pump.
    • Boiler circulation wat...
    • Boiler light up proced...
    • Start permissives of M...
    • What is Working Princ...
    • How MDBFP scoop tube w...
    ‪@PPTK1506‬
    ‪@PowerPlantDiscussion‬
    ‪@PowerPlantGuide‬
    ‪@BhagwanSRathore‬
    ‪@rahulsirclasses1987‬
  • Věda a technologie

Komentáře • 19

  • @qolisfandrairawan2130
    @qolisfandrairawan2130 Před 2 měsíci +1

    Sir, why the pump speed is higher than motor speed ? By using hydraulic coupling, the output speed must lower than motor speed, isn't ?

    • @kpatelbla
      @kpatelbla  Před 2 měsíci

      Actually Motor input power must be higher than pump output, but RPM can be increased by hydraulic coupling, no issue. Suppose Motor input power 12 MWH so pump mechanical output cannot exceed 12 MWH.

  • @0503manoj
    @0503manoj Před měsícem +1

    Sir
    Before starting of MDBFP reheater Attempretion valve and super heater Attempretion valve always should have open or not...?

    • @kpatelbla
      @kpatelbla  Před měsícem

      It can be made open but block valve of both attemperator must be closed.

  • @user-wm5ti1od6r
    @user-wm5ti1od6r Před 4 měsíci +1

    Good explanation. Please explain Operation of hydraulic coupling. Scoop function and Remote trip solenoid

    • @kpatelbla
      @kpatelbla  Před 4 měsíci

      You can watch ' How scoop tube function' video czcams.com/video/WILqwqeLd9E/video.htmlsi=C8mw2HscAzPMFJdq

    • @kpatelbla
      @kpatelbla  Před 4 měsíci

      Remote trip solenoid & Rapid start, I will explain.........

  • @pankajkumarpatel5664
    @pankajkumarpatel5664 Před 4 měsíci +2

    Sir boostor pump suction me buket stainer or main pump me conical stainer hota hai or sir boostor pump ka suction pr 8 kg tak hota hai

    • @kpatelbla
      @kpatelbla  Před 4 měsíci

      Yes you are correct, but suction pressure varies according to Deaerator pr

  • @chandreshpatel6380
    @chandreshpatel6380 Před 4 měsíci +1

    Sir need video on bearing stiffness or shaft stiffness

  • @devivara1162
    @devivara1162 Před 4 měsíci

    Sir why balancing line is provided before pump in Condensate extraction pump??in power plant???

    • @kpatelbla
      @kpatelbla  Před 4 měsíci

      The only purpose of balancing line is to prevent the shifting of Rotor of the pump during operation.

  • @motive0507
    @motive0507 Před 4 měsíci +1

    ECW water is going to mechanical seal cooling and also to seal jacket. What is seal jacket. Please differentiate mechanical seal and seal jacket

    • @kpatelbla
      @kpatelbla  Před 4 měsíci

      Mechanical seal water goes to mechanical seal cooler instead of directly to mechanical seal. Jacket cooling provided at pump jacket.

    • @motive0507
      @motive0507 Před 4 měsíci +1

      @@kpatelbla could you please physically differentiate seal jacket and mechanical seal

    • @motive0507
      @motive0507 Před 4 měsíci

      Please give reply

  • @devivara1162
    @devivara1162 Před 4 měsíci +1

    Sir what is water hammer??? any 3 reasons why this water hammer forms??

    • @kpatelbla
      @kpatelbla  Před 4 měsíci

      When steam comes in contact of condensate water it moves with high velocity of steam and create hammering sound on pipe surface, before it get condense.