Daikin | Error E9 | Malfunction of moving part of Electronic Expansion Valve

Sdílet
Vložit
  • čas přidán 28. 10. 2022
  • Brand : Daikin Super inverter
    model : RZR71KUV1
    error code : E9
    E9 : Outdoor Unit Malfunction of Moving Part of Electronic Expansion Valve
    Method of Malfunction detection:
    1)check disconnected of connector
    2)check continuity of Expansion Valve coil
    #bonmj #airconditioner #daikin

Komentáře • 118

  • @armanvallozo8722
    @armanvallozo8722 Před 2 měsíci +2

    sir bon swiching from phillipines thank you for shar your skill ..

  • @RP-mt6bp
    @RP-mt6bp Před rokem +2

    I enjoyed very much this clip. Short and to the point. Exactly what i need. Thank you.

  • @mahfuzalam7836
    @mahfuzalam7836 Před 6 dny

    Sir good you teaching ❤and your video very useful help teaction vrv good 💯 information

  • @hernanbensurto573
    @hernanbensurto573 Před rokem +1

    GOD bless Mr. Bon. From philippens thank you for sharing knowledge.

  • @salimagwan9672
    @salimagwan9672 Před rokem +1

    Bon sir we are eagerly waiting for your video the way you explain it is very good thank you very much

  • @footballguy4209
    @footballguy4209 Před rokem +1

    Thank you 🙏 for sharing AC knowledge Mr.Bon MJ

  • @sv6k0a39
    @sv6k0a39 Před 8 měsíci +1

    Very experienced technician.

  • @hamadahamed3655
    @hamadahamed3655 Před rokem +1

    الله بنور على يا هندسه على الفن الجميل يا ليت كل الفيديوهات مترجمه لغه العربيه

  • @janshaw5472
    @janshaw5472 Před rokem +1

    Good teaching 谢谢bon

  • @karimchiu7527
    @karimchiu7527 Před rokem +1

    thanks sir Bon

  • @muhammadali-uo7oi
    @muhammadali-uo7oi Před rokem +1

    Terbaik Boss.ku

    • @BonMj
      @BonMj  Před rokem

      Terima Kasih🙏

  • @GodofredoTalin
    @GodofredoTalin Před rokem +1

    Thank you sir for this informative video❤

    • @BonMj
      @BonMj  Před rokem +1

      Welcome 🙏

  • @AJITHKUMAR...
    @AJITHKUMAR... Před rokem +1

    Sir...your all videos easily learn Aircon

  • @rahatislam9583
    @rahatislam9583 Před rokem +1

    Thanks for useful video.

  • @manjuviratuperavai3610
    @manjuviratuperavai3610 Před rokem +1

    Thank you sir helpful your video 😍🙏

    • @BonMj
      @BonMj  Před rokem

      Welcome 🙏🙏

  • @juruteknik6436
    @juruteknik6436 Před rokem +1

    tq mr bon ,

  • @meshaw
    @meshaw Před rokem +1

    More videos master bon God bless 🙏

  • @ssajid2845
    @ssajid2845 Před rokem +1

    Bon sr thanks your are gem sr we know how useful your vedeos.. Sr if you visit india 🇮🇳pls meet us lot of my aircon friends and special me i want to meet you.. Lot's of love from 🇮🇳

    • @BonMj
      @BonMj  Před rokem

      Thanks bro🙏🙏

  • @jamestan7901
    @jamestan7901 Před rokem +1

    Thank you sir

  • @welcometomydreamworld6812

    Thnxx 👌💕

  • @mohammedmo4109
    @mohammedmo4109 Před rokem +1

    Thanks

  • @koksengcheong8862
    @koksengcheong8862 Před rokem +1

    Nice ❤

  • @pkaruppaiyapvenkat6437
    @pkaruppaiyapvenkat6437 Před rokem +1

    Thanks sir, I am from india

    • @BonMj
      @BonMj  Před rokem

      Welcome. Thanks 🙏

  • @yeman7563
    @yeman7563 Před 4 měsíci +1

    Thank for sharing your experience bon, i also want to join your team how to join

  • @radsamrout3389
    @radsamrout3389 Před rokem +1

    very good

  • @JDT738126
    @JDT738126 Před rokem +1

    So did you say the body needs to be replaced as well when there is an issue? I assume you can braze in a new one?

  • @vilsonraj983
    @vilsonraj983 Před rokem +2

    Boss how to check cu fan motor reading and fcu fan motor reading for Daikin type

  • @juruteknik6436
    @juruteknik6436 Před rokem +1

    good day mr bon ,if mr bon has free time, there is a video about troubleshooting floor standing 5 hp, you can share it, thanks mr bon

  • @peramaraj2763
    @peramaraj2763 Před rokem +1

    Hi sir
    How to check linear expansion valve resistance reading in Mitsubishi indoor FCU.

  • @karaors8970
    @karaors8970 Před rokem +2

    🧿

  • @asangajayalath1665
    @asangajayalath1665 Před rokem +1

    Good job.. today you had a hard job without your team...

    • @BonMj
      @BonMj  Před rokem

      Yes.Thanks 🙏🙏

  • @toufikmatib9855
    @toufikmatib9855 Před rokem +1

    Hello Thx for sharing ,please i got high pressure sensor on VRV2 R407 a ,faulty and cant find the part as it old ,is there any idea for retroffit or like puting something else instead.
    Many thx

  • @shaikhfaisal4367
    @shaikhfaisal4367 Před 7 měsíci +1

    hi bon i like ur videos very much... i want to know in daikin vrv-x how many eev are there ...is there 2 eev in vrv 1 in outdoor 2nd in indoor plz help...& plz gude me the suction pressure of vrv- r-410 what is the ideal suction pressure in full load thank u sir...

    • @BonMj
      @BonMj  Před 7 měsíci

      New VRV-X got 3 EEV(main,injection and auto charge)
      Every indoor got 1 EEV
      Pressure depending on the system

    • @shaikhfaisal4367
      @shaikhfaisal4367 Před 7 měsíci

      i highly appreciated u...sir thank you for replying@@BonMj

  • @peramaraj2763
    @peramaraj2763 Před rokem +1

    Hi sir
    Thanks for your update the video sir
    I have one doubt sir ,why could not check gas liquid side one to one system. May i know sir

    • @BonMj
      @BonMj  Před rokem

      I got check actually,but not in the video.

    • @peramaraj2763
      @peramaraj2763 Před rokem +1

      @@BonMj this one need to check or not sir

    • @BonMj
      @BonMj  Před rokem

      @@peramaraj2763 better check.
      High pressure service port is on top.

    • @peramaraj2763
      @peramaraj2763 Před rokem +1

      @@BonMj i check gas liquid side sir but gas lower than suction side

    • @BonMj
      @BonMj  Před rokem

      @@peramaraj2763 may insufficient gas

  • @karaors8970
    @karaors8970 Před rokem +1

    ✋👍🤳🛠️🇹🇷

  • @mymusic-tp1bh
    @mymusic-tp1bh Před rokem +1

    Good lecture! Sir, please advise how to test run with outdoor push button switch, as i find the BS4 is for pump down?

    • @BonMj
      @BonMj  Před rokem

      Vrv?

    • @mymusic-tp1bh
      @mymusic-tp1bh Před rokem +1

      @@BonMj Super inverter, your model RZR71

    • @BonMj
      @BonMj  Před rokem

      @@mymusic-tp1bh just long press test button.

    • @mymusic-tp1bh
      @mymusic-tp1bh Před rokem +1

      @@BonMj BS1-Mode, BS2-Set, BS3-Return, BS4-Pumpdown, find no test button on outdoor pcb

    • @BonMj
      @BonMj  Před rokem

      @@mymusic-tp1bh czcams.com/video/RleCvum-bEQ/video.html

  • @peramaraj2763
    @peramaraj2763 Před rokem +1

    Hi sir
    I have a doubt sir DAIKIN ducted unit drain pump open but incoming fcu power have not turn off pump still running rights that time water reverse back what is the cause of problem drain pump or drain pipe

  • @peramaraj2763
    @peramaraj2763 Před rokem +1

    Hi sir

  • @donlynmasancay248
    @donlynmasancay248 Před měsícem +2

    sir the anothere indoor not cooling but athere indoor cooling good vrf mitsubishi what possible causes sir

    • @BonMj
      @BonMj  Před měsícem +1

      Check LEV

    • @donlynmasancay248
      @donlynmasancay248 Před měsícem

      sir thanks but if icheck i use computer or there are anyway to how unit to indentify where unit defective indoor

    • @donlynmasancay248
      @donlynmasancay248 Před měsícem

      i dont have computer or laptop to check the unit there are anyway to check LEV defective

  • @frengkyagungt1159
    @frengkyagungt1159 Před měsícem +1

    Sir, what is the cause of error E5 on the Daikin RZR140LVVM(4) floor standing AC? please explain how to handle it

    • @BonMj
      @BonMj  Před 24 dny

      Inverter compressor lock

  • @salimagwan9672
    @salimagwan9672 Před rokem +1

    Bon sir is an indoor which is master wired remote is not getting any error in it and its fan motor is not running and running without direct pcb then have ordered new pcb yet same problem is coming plz help sir

    • @BonMj
      @BonMj  Před rokem

      May be pcb

    • @salimagwan9672
      @salimagwan9672 Před rokem

      Sir, I have asked for a new one, still the problem is coming in the same mode number FXMQ50ARV16
      PCB model FXMQ-NVE6
      EB16046(c)

    • @salimagwan9672
      @salimagwan9672 Před rokem +1

      Even after installing a new PCB, the same problem is coming, if you run the fan motor without a PCB, then it is running fine and this problem is coming only in the master indoor, reset the outside door and has also done test mode

  • @leongem9796
    @leongem9796 Před rokem +1

    Hi Mr Bon may i know your digital multimeter brand and model, thank you in advance.

    • @BonMj
      @BonMj  Před rokem

      No more this type meter, i also thinking to change new once, cant find anymore, i use it more than 12yrs.very good brand.

  • @cantran5730
    @cantran5730 Před rokem +1

    Pls help me: when turning off the cb to clean the daikin vrv indoor unit, how can the system not report an error? Tks

    • @BonMj
      @BonMj  Před rokem

      VRV3?

    • @cantran5730
      @cantran5730 Před rokem +1

      Vrv 4

    • @cantran5730
      @cantran5730 Před rokem +1

      does it have to mode 2.90?

    • @BonMj
      @BonMj  Před rokem

      @@cantran5730 Normally VRV4 one of the indoor faulty or miss communication, you try to reset(push the return button more than 10 second)and wait untill the led off.

    • @BonMj
      @BonMj  Před rokem

      @@cantran5730 this is for emergency use, like say one of the indoor miss communication ,but this mode only for 24hrs

  • @user-yp7mq1bl1j
    @user-yp7mq1bl1j Před rokem +1

    Hello bong air con dailkin inverter compresor not working fan not work .out door not work .in door working normal. No show error cord

    • @BonMj
      @BonMj  Před rokem

      Check outdoor thermistor

    • @user-yp7mq1bl1j
      @user-yp7mq1bl1j Před rokem

      @@BonMj l checked oready bong .
      I change PCB out door and indoor also not working.

  • @vibe6473
    @vibe6473 Před rokem +1

    Sir daikin vrv 3 inverter compressor is dc or ac

  • @bhuvanraya
    @bhuvanraya Před 10 měsíci +1

    Hello bon

    • @BonMj
      @BonMj  Před 10 měsíci +1

      Hi

    • @bhuvanraya
      @bhuvanraya Před 10 měsíci

      @@BonMj on problem mitsubishi electric vrf .but run colling not properly only 5 Ampere teck

  • @edwinosuyostv85
    @edwinosuyostv85 Před rokem +1

    Eev problem

  • @johnwoo8263
    @johnwoo8263 Před rokem +1

    Hi master BON
    can help Daikin inverter error code H6 H8 and H9
    THANK

  • @golfanuphong7139
    @golfanuphong7139 Před 9 měsíci +1

    Daikin error e1

    • @BonMj
      @BonMj  Před 9 měsíci

      Check outdoor pcb