HOW TO TEST DAIKIN EEV COIL (5 Cables).

Sdílet
Vložit
  • čas přidán 26. 08. 2024
  • I hope this video helps!

Komentáře • 37

  • @yrwyreazureAjuhtrea7
    @yrwyreazureAjuhtrea7 Před měsícem

    These videos are godsend for a tech who’s new to troubleshooting this type of equipment, thank you.

  • @user-gk2ck4pr4g
    @user-gk2ck4pr4g Před 2 měsíci +2

    I see. Thank you.
    Just recently, the EEV coil did not work and the copper tube was frozen.
    Unfortunately, it was Daikin.

  • @jonathonwilliams6722
    @jonathonwilliams6722 Před rokem +4

    Love this sort of content. Gonna share with the lads at work to help them get a better understanding.
    Any chance of future vids of similar nature for other components? Your explanations are a lot better than fault finding from a book!

    • @maracservices
      @maracservices  Před rokem +1

      Thanks mate. Yeah that’s the plan, I’ve made a playlist called Daikin training where I plan to do a video for each component in an air conditioner. I’m no expert, I’m just making videos that I wish I had when I was learning. There will definitely be more videos of this nature. Cheers

  • @denimdimi
    @denimdimi Před 3 měsíci +3

    So I had a daikin 4MXM80 multisplit. After a month 1 room didnt work (valve didnt open). Placed a new motherboard, which blew up a month after installing. Daikin didnt want to send new motherboard under warranty. We decided to buy a new outdoor unit. (4000 euro). And after a month the new one had the same problem, just different room. Now all the sudden Daikin admid that it is a common problem on the MXM series, due to "too low voltage going to the magnets". They will send a new motherboard. Not sure if that is the problem, or if the pins just get stuck. Just FYI so you know :)

    • @the-real-things
      @the-real-things Před 8 dny

      We have exactly the same problem with the 4MXM68A. Been going on for 2 years now. They replaced the motherboard a month ago. We thought it was solved but this week one unit failed again. So changing the motherboard did not solve the issue. My guess is that the magnetic valves are just prone to get stuck over time.

  • @robalexander7348
    @robalexander7348 Před rokem +1

    Thanks Mitch, that will be helpful to the new A/C tech guys learning out in the field 👍

  • @terryh8421
    @terryh8421 Před měsícem

    Thank you, useful info.

  • @user-yl9zp8zs4e
    @user-yl9zp8zs4e Před měsícem

    Very good tnx info

  • @ricardofernandes1571
    @ricardofernandes1571 Před rokem +2

    Always great content.

  • @agiusproductions5092
    @agiusproductions5092 Před 7 měsíci +1

    My go to guy for all ac your the best bro

  • @musakavalci9470
    @musakavalci9470 Před měsícem

    Great stuff as always. Thanks 👍🏼

  • @vrvlearn8622
    @vrvlearn8622 Před 29 dny

    Thank you very much ❤

  • @lasim2635
    @lasim2635 Před 6 měsíci

    Thank you Mitch!

  • @ameenmakramey1274
    @ameenmakramey1274 Před 8 měsíci

    Professor, if you could please explain to us a video about the closed electric expansion valve, which carries the model EX7-121 from the working company Amrison, the method of connecting it to the driver, its maintenance, and its problems. I thank you for your cooperation. We greatly appreciate it.

  • @L8NiteCoffeeSips
    @L8NiteCoffeeSips Před 5 dny

    So answer me this, cousin. On the small solenoid, if readings being 45,46,46,46;
    What would be considered bad ohm readings it were bad?

  • @mtz5582
    @mtz5582 Před 4 měsíci

    I've subscribed as well as I have faith in you.

  • @declankearney9353
    @declankearney9353 Před měsícem +1

    Hi Mitch have you ever tried getting boards repaired I have always thought it crazy that we have to replace a complete board when I assume all they need is a component ie processor or something. I have tried but had no luck.

    • @maracservices
      @maracservices  Před měsícem

      @@declankearney9353 I’ve taken a board out that was no longer available and taken it to a repairer who did actually repair it but after it was reinstalled, a different fault came up.
      I personally think it’s too risky trying to repair because a component failure can take out another component and you won’t know until you turn it on. Also if it’s a Daikin processor that’s faulty, the repairer won’t carry those parts unfortunately. I just think manufacturers need to make more durable boards but I do know what you mean.

  • @alexibonnet2634
    @alexibonnet2634 Před 9 měsíci

    This was excellent content without the service facts manual you can use this as a rule of thumb

  • @MitchellSmyth-r8f
    @MitchellSmyth-r8f Před měsícem

    Hey mate, Do you know resistances & voltage outputs required on a Reversing Valve solenoid coil on a Daikin Ducted 14kw

  • @gang1798
    @gang1798 Před 14 dny

    So this tells you if the windings in the eev is good?

  • @sheldon8115
    @sheldon8115 Před 9 dny

    How often do you get bad eev

  • @alexibonnet2634
    @alexibonnet2634 Před 9 měsíci

    Can you put a video using the EEV tester magnet
    DAIKIN part # 99S0038

  • @mtz5582
    @mtz5582 Před 4 měsíci

    So what are the rest of rhe wires for!!

  • @mikaelahyakuya3485
    @mikaelahyakuya3485 Před rokem +1

    Just wonder, have you seen any rust problem on the EEV motor part (the whole black thing)

    • @maracservices
      @maracservices  Před rokem

      Can’t say I’ve ever seen rust issues with them mate. Have you? I’m curious!

    • @mikaelahyakuya3485
      @mikaelahyakuya3485 Před rokem

      @@maracservices (I'm homeoner myself, so I may not have a lot of information about this) However, I did see them in the R22 system (2012) and the new R32 system (2-3 years ago) and plus the outdoor board issues.
      there is a video link here: watch?v=Zk4Ku284cPU
      timestamp: 5:01 is the capacitor that failed in the inverter board (compressor cannot run/cutoff at high speed/ramping up)
      10:40 is the rusting EEV
      And there are lots of video showing how to change the capacitor on the inverter board by technician and homeowner, that speak the number of how many of them failed.

  • @Jim-yk9zw
    @Jim-yk9zw Před 11 měsíci +1

    Do you see these things failing much mate?

    • @maracservices
      @maracservices  Před 11 měsíci +1

      Very very rare in my opinion. But I always check them when I see a faulty board for piece of mind

    • @Jim-yk9zw
      @Jim-yk9zw Před 11 měsíci

      @@maracservices Good to know. Thanks for the reply Mitch.

  • @mtz5582
    @mtz5582 Před 4 měsíci

    Please watch Craig at Ac service tech...I have high hopes you can do better like him for our side of things ..a smile and well tailored contents will take you there or else....

  • @rosamondlucas8658
    @rosamondlucas8658 Před rokem

    Promo sm

  • @lukskywalker834
    @lukskywalker834 Před 6 měsíci

    What about Daikin PQM 10175 6 cabels, similar values?