The DAIKIN R32 Ducted Air Conditioner no one can seem to fix! ⎮ U0 Error
In this video I attend a service call to fix a Daikin Ducted Air Conditioning system that two technicians before me had already tried to fix and couldn't work it out.
Even a third tech tried to work it out over the phone and was going in the wrong direction. Watch the video to see what the issue was.
zhlédnutí: 9 310

Video

Daikin Air Conditioner NOT HEATING!
zhlédnutí 2,5KPřed 14 dny
In this video I attend a service call where the customer's Daikin Ducted Air Conditioning system is no longer heating well.
How to test Daikin EEV Coil (6 Cables).
zhlédnutí 1,2KPřed 21 dnem
I hope this helps someone out there.
Replacing a 20 year old Mitsubishi Electric Air Conditioner.
zhlédnutí 3,2KPřed měsícem
HVAC⎪HVACR⎪REFRIGERATION VIDEOS In this video I replace an old Mitsubishi Air Conditioner that has a faulty PCB and gas leak. I replace It with a Daikin Air 8.5kW Conditioning unit.
Installing a Daikin Ductless Mini Split
zhlédnutí 4,2KPřed měsícem
HVAC⎪HVACR⎪REFRIGERATION VIDEOS In this video I replace a Mitsubishi Electric Air Conditioner with a Daikin. Enjoy the video.
How to test Daikin PCB for Communication Faults.
zhlédnutí 2,6KPřed měsícem
In this video I show you how to test if a Daikin PCB is communicating normally or abnormally.
Diagnosing Daikin E5 Error
zhlédnutí 6KPřed 2 měsíci
HVAC⎪HVACR⎪REFRIGERATION VIDEOS In this video I diagnose what's wrong with a Daikin Air Conditioner displaying an E5 fault code. Marac Services Pty Ltd Located in Sydney.
Actron Air Conditioner displaying E9 Fault
zhlédnutí 2,7KPřed 2 měsíci
Actron Air Conditioner displaying E9 Fault
Mitsubishi Electric Air Conditioner displaying P8 Fault
zhlédnutí 2,5KPřed 2 měsíci
Mitsubishi Electric Air Conditioner displaying P8 Fault
Re Installing Daikin Air Conditioners
zhlédnutí 2,5KPřed 2 měsíci
Re Installing Daikin Air Conditioners
I CAN'T BELIEVE that this has happened AGAIN!
zhlédnutí 4,4KPřed 3 měsíci
I CAN'T BELIEVE that this has happened AGAIN!
Fujitsu Air Conditioner not working
zhlédnutí 3,5KPřed 3 měsíci
Fujitsu Air Conditioner not working
Actron Air Conditioner | Fans running but not blowing cold air
zhlédnutí 1,7KPřed 4 měsíci
Actron Air Conditioner | Fans running but not blowing cold air
Replacing the compressor on a Temperzone Air Conditioner.
zhlédnutí 3,8KPřed 7 měsíci
Replacing the compressor on a Temperzone Air Conditioner.
Temperzone Air Conditioner tripping the circuit breaker.
zhlédnutí 2,1KPřed 7 měsíci
Temperzone Air Conditioner tripping the circuit breaker.
ACTRON AIR CONDITIONER NOT COOLING!!
zhlédnutí 4,1KPřed 8 měsíci
ACTRON AIR CONDITIONER NOT COOLING!!
ACTRON AIR CONDITIONER NOT BLOWING COLD AIR?
zhlédnutí 3,6KPřed 8 měsíci
ACTRON AIR CONDITIONER NOT BLOWING COLD AIR?
INSTALLING AN R32 DAIKIN DUCTED AIR CONDITIONER
zhlédnutí 3,5KPřed 8 měsíci
INSTALLING AN R32 DAIKIN DUCTED AIR CONDITIONER
How to clean a Ductless Mini Split.
zhlédnutí 2,4KPřed 9 měsíci
How to clean a Ductless Mini Split.
HVAC VAN BUILD⎟Episode 5
zhlédnutí 1,5KPřed 9 měsíci
HVAC VAN BUILD⎟Episode 5
INSTALLING A DAIKIN R32 DUCTED AIR CONDITIONER AND WHY I USE 'MyPlace' from ADVANTAGE AIR.
zhlédnutí 14KPřed 9 měsíci
INSTALLING A DAIKIN R32 DUCTED AIR CONDITIONER AND WHY I USE 'MyPlace' from ADVANTAGE AIR.
Repairing Daikin UF Error
zhlédnutí 2,6KPřed 9 měsíci
Repairing Daikin UF Error
INSTALLING AN R32 DAIKIN DUCTED INVERTER AIR CONDITIONER
zhlédnutí 8KPřed 10 měsíci
INSTALLING AN R32 DAIKIN DUCTED INVERTER AIR CONDITIONER
ALL THIS COULD HAVE BEEN AVOIDED!
zhlédnutí 1,6KPřed 10 měsíci
ALL THIS COULD HAVE BEEN AVOIDED!
Diagnosing Daikin U2 Error | # 2
zhlédnutí 10KPřed 10 měsíci
Diagnosing Daikin U2 Error | # 2
Diagnosing Daikin UF Error
zhlédnutí 4KPřed 10 měsíci
Diagnosing Daikin UF Error
Repairing Panasonic F91 Error
zhlédnutí 6KPřed 10 měsíci
Repairing Panasonic F91 Error
INSTALLING A DAIKIN R32 INVERTER MINI SPLIT AIR CONDITIONER
zhlédnutí 18KPřed 11 měsíci
INSTALLING A DAIKIN R32 INVERTER MINI SPLIT AIR CONDITIONER
HOW TO INSTALL AN R32 DAIKIN DUCTED AIR CONDITIONER?
zhlédnutí 12KPřed 11 měsíci
HOW TO INSTALL AN R32 DAIKIN DUCTED AIR CONDITIONER?
How to Cut 90 ⁇ Bends on Metal trunking
zhlédnutí 2,6KPřed 11 měsíci
How to Cut 90 ⁇ Bends on Metal trunking

Komentáře

  • @daneattard8640
    @daneattard8640 Před 23 hodinami

    What you think of the whipcool cordless

    • @maracservices
      @maracservices Před 23 hodinami

      @@daneattard8640 so far I like it but give me a month and I’ll give you an honest update

  • @bradgoodale3249
    @bradgoodale3249 Před dnem

    Never had to change a daikin compressor in 30 years there you go,it was always board problems.

  • @leviv2870
    @leviv2870 Před dnem

    What is the tool he used with the molex plug?

    • @maracservices
      @maracservices Před 23 hodinami

      @@leviv2870 it’s a Daikin blue tooth tool that lets me read data from the unit.

  • @L8NiteCoffeeSips
    @L8NiteCoffeeSips Před 2 dny

    So answer me this, cousin. On the small solenoid, if readings being 45,46,46,46; What would be considered bad ohm readings it were bad?

  • @bradgoodale3249
    @bradgoodale3249 Před 2 dny

    Mitch i tried using that same bag set up couple years ago it was shit heavy bulky for high wall splits heaps lighter set ups on the market now.

    • @maracservices
      @maracservices Před 23 hodinami

      @@bradgoodale3249 I’m scared of the lighter types in case they break and leak but I’m sure they would be fine

    • @bradgoodale3249
      @bradgoodale3249 Před 23 hodinami

      Yeah have to be careful there's also alot of shit out there

  • @pat750
    @pat750 Před 2 dny

    Very nice install, Mitch! Those units are so quiet!

  • @Louisyongcool2328
    @Louisyongcool2328 Před 2 dny

    Hey Mitch, like to see if you can make a video on the inverter checker that will be a great help us thanks👍

  • @daneattard8640
    @daneattard8640 Před 3 dny

    Great video mate , I’ll definitely be using that advice for the recovery mode on the 32 units.

  • @robalexander7348
    @robalexander7348 Před 3 dny

    Well Mitch, your livin the High Life now ;)

  • @CapitalCoastHVAC
    @CapitalCoastHVAC Před 3 dny

    Looks great 👌.

  • @rottweiler9535
    @rottweiler9535 Před 3 dny

    OH BOOHOO 8.5C , that a nice moring, you are just so spoiled, talk to me when you are -35c

  • @santiagoyaguesegura5765

    Hola yo hace unos días cambié una condensadora la 125 por una 100 del mismo año y ok

  • @duotronic6451
    @duotronic6451 Před 4 dny

    27:30 evacuated the refrigerant, what escaped? Some was missed? I'm a curious non HVAC tech.

  • @charleslewis7007
    @charleslewis7007 Před 4 dny

    Please help me I'm having a hard time finding the outdoor dc fan motor part for my daikin RXN24KEVJU5 outdoor unit

  • @Dynamacrtm
    @Dynamacrtm Před 4 dny

    It sounds like the airhub can only cycle on/off based on the return air sensor and this can't be changed, is this correct? That's quite a limitation. Also the airhub can only set zones to +-2c of master. I assume myair doesn't have this limitation? Thanks.

  • @rons4778
    @rons4778 Před 5 dny

    In refrigeration cleanliness is the upmost priority

  • @SombraLocs
    @SombraLocs Před 5 dny

    Looks pretty bulky. A lot of times those residential units don’t have room for them.

  • @sheldon8115
    @sheldon8115 Před 5 dny

    I can hear it too. It’s a considerably big leak 👍

  • @stevenmoomey2115
    @stevenmoomey2115 Před 5 dny

    The thing I like about Daiken is they use Copper Tube in their units, not the steel, that rust and gets pinholes in it. I’m in the USA, Retired. I have the same Fluke, Temperature Probes and Recovery Machine, you have.

  • @sheldon8115
    @sheldon8115 Před 5 dny

    How often do you get bad eev

  • @sheldon8115
    @sheldon8115 Před 5 dny

    Good job 👍

  • @ssikkema4222
    @ssikkema4222 Před 5 dny

    nice video.. but please the music, autotune hurts my ears. 😅

  • @AaronPowellvox
    @AaronPowellvox Před 6 dny

    Damn thing is way too close to the wall for sure.

  • @MohammadArshad-k1r
    @MohammadArshad-k1r Před 6 dny

    Hello sir my name is Mohammad Arsh I am working in Saudi Arabia since last 3 years I want to work in Australia also I want to get job

  • @genepierson1728
    @genepierson1728 Před 6 dny

    Thanks for sharing. I'm confused. You pulled a vacuum, but then when you removed the schrader valve, a small bit of oil sprayed out. (Right?) How is that possible if the system was under a vacuum?

    • @maracservices
      @maracservices Před 6 dny

      @@genepierson1728 no worries mate. So I hadn’t pulled a vacuum at that point, all I had done was reclaim the refrigerant. This means 99% of the refrigerant is in a bottle now but there is still a tiny bit of pressure in the system. That red pump with the big hose was the vacuum pump. Cheers

  • @ThomasMarchant-c1y
    @ThomasMarchant-c1y Před 6 dny

    Hey Mitch. Ive had in the past a UO on a daikin fault.had a bad eev. It would run fine in heating but every now and than would pump down into vacuume in cooling mode but not always. Would run a few weeks than fault out Replaced the valve and has been fine since.

  • @bradgoodale3249
    @bradgoodale3249 Před 7 dny

    Mitsubishi Electric

  • @bradgoodale3249
    @bradgoodale3249 Před 7 dny

    spit on ya finger keep the silicon off ya finger

  • @bradgoodale3249
    @bradgoodale3249 Před 7 dny

    the shit we have to buy back from china is embrassing dude fuk the shit we have to deal with on ya Mitch.

  • @bradgoodale3249
    @bradgoodale3249 Před 7 dny

    Mitch so many questions my ocd with ya hoses fuk does me head in haha was that house open completely just asking,condensing unit to close to wall.i see alot of issues as soon as you pulled up good thinking start from scratch.

  • @machaf
    @machaf Před 7 dny

    I've heard lots of issues with copper pipe in the US too. Some type of reaction causing pin hole leaks. One gent only has it happen on the white insulation, no issues with the black stuff.

  • @stevencarrillo3615
    @stevencarrillo3615 Před 7 dny

    Thanks I learnd something new thanks.

    • @maracservices
      @maracservices Před 7 dny

      @@stevencarrillo3615 no worries mate cheers

  • @pat750
    @pat750 Před 7 dny

    How did they convert from ductless to ducted on an existing house? Also, I'd be very interested in seeing more detail about the controller for this system.

  • @pat750
    @pat750 Před 7 dny

    Beautifully done! Let us hear the unit's running sound. I like to hear how quiet those units are!

  • @pat750
    @pat750 Před 7 dny

    Can you put more narration into your videos? I'd like to know more about what you're doing and why. The background music is nice, but I want to learn more about the whole process.

  • @pat750
    @pat750 Před 7 dny

    I use Klein Tools a lot.

  • @xtractify
    @xtractify Před 8 dny

    Did you purge the blue hose before charging? I saw you purge the yellow hose, maybe you purged blue hose off camera. Also, instead of removing the VCRT after pulling vacuum, you could just leave it on and connect hose from bottle of gas to VCRT and charge, then put core back in.

  • @rdenir
    @rdenir Před 8 dny

    I use Trace a Gas with the CPS electronic leak detector and it works very well, however it would go crazy with a leak this big and I, like you wouldn’t have bothered using it had I been able to hear it as loud as you could. I also would have done exactly as you did in advising the customer but true, that unit is on it’s last legs and I hate whenever I do a repair like that and it fails 3 months down the track and the client reminds me how much they paid 3 months back and it has already failed again.. That’s why the replacement option gets pushed onto customers..

  • @colinspencer2205
    @colinspencer2205 Před 8 dny

    Had mine since new eight years now. Works exceptionally well. But that's just me comparing with the reverse cycle ducted systems I installed back in the 1970s. The E9 code is coming up often lately, and I'm becoming suspicious of the life expectancy of compressors in these systems running R412 refrigerant. I restart it by pressing the mode selection button and it then returns to run mode. No problem for anything from a few days to a few weeks, then it does it again.

  • @KINGDADDYBOB
    @KINGDADDYBOB Před 8 dny

    If you hold orange meter button while rotating center knob to on, the meter will not time off/out.

  • @davidhogg8274
    @davidhogg8274 Před 8 dny

    How did you get that in recovery mode from indoor controller ?

    • @johngaunt2734
      @johngaunt2734 Před 23 hodinami

      I wanna know the Same thing didn’t no this existed

    • @davidhogg8274
      @davidhogg8274 Před 17 hodinami

      @@johngaunt2734 neither did I thought it had to be done from condenser

  • @greywolf271
    @greywolf271 Před 10 dny

    Hey Mitch, a somewhat parallel issue with reactive chemicals in electrical engineering. In the 60's or 70's there was an electrical cable insulating material used worldwide that after a number of years caused a chemical reaction with the copper conductors. It's a greenish stain/goo. I only came across this with a house renovation. Fortunately it does'nt cause insulation breakdown, just a massive disgusting stain, especially in wall switches, light fittings, where you don't really want to see and deal with it. Funnily enough, in the era before cheap chinese products invaded the landscape.

  • @CodyHVAC
    @CodyHVAC Před 10 dny

    Man how would you go about maintenance or possible leaks/faults in the future. Appartment scare the shit out of me

    • @maracservices
      @maracservices Před 7 dny

      @@CodyHVAC so this has an access panel in the pantry where you can access the indoor boards, pipe and drain. Then there is another man hole right near the sliding door outside in the corner. That second man hole is useless but I put it in there so IF we get leaking pipe, I can get pipe across to the outdoor unit lol.

  • @gang1798
    @gang1798 Před 10 dny

    So this tells you if the windings in the eev is good?

  • @44whip
    @44whip Před 11 dny

    Did standing sst vs ambient temp match when you first put the gauges on?

    • @maracservices
      @maracservices Před 11 dny

      @@44whip hey mate, what did you mean by SST?

    • @44whip
      @44whip Před 11 dny

      @@maracservices did you notice what the gauges were at before the unit was running? Pressures to temperature vs what the ambient was

  • @ranchocommodorereef
    @ranchocommodorereef Před 11 dny

    This outdoor Mitsubishi AC is my childhood because my grandfather in Botswana, Africa used to have it for his living room.

  • @CodyHVAC
    @CodyHVAC Před 11 dny

    Just test the compressor windings? Then you will know if the compressor is stuffed?

  • @derekg9178
    @derekg9178 Před 11 dny

    Did you not have to pull a vacuum on the recovery tank? Or have too? In the US it’s best to always pull one.

    • @derekg9178
      @derekg9178 Před 11 dny

      I guess with the refrigerant being contaminated it’s not needed.

    • @maracservices
      @maracservices Před 11 dny

      @@derekg9178 so over here you can get a recovery tank that’s clean and it costs $150 to get it from the wholesaler. This is for when you will reuse the gas so you’ll absolutely vac it. This bottle was a reclaim bottle that’s not clean and $0 from the wholesaler. It’s used for refrigerant you are disposing of. You don’t need to vac this as it’s getting disposed of. When you take it back to the wholesaler, you get credited for every kg you return to incentivise doing the right thing. 👍🏻

  • @mazayamazayanadira6862

    Goodjob mate. Made indonesian😊

  • @nunya6081
    @nunya6081 Před 12 dny

    Good pickup! In future though the side port on the VC2G is meant for a service port as it still has a schrader core, you’re effectively just evacuating as if you hadn’t pulled the cores from the unit service valves (assuming you’ve left that schrader core in on the side of the VC2G). Remove the stem and the schrader core from the top of the tool and attach your vacuum hose to the top of the VC2G, then there were will be uninterrupted flow.

    • @maracservices
      @maracservices Před 12 dny

      @@nunya6081 thanks mate. Yeah I took the schreadar out on the side port so there was absolutely no restriction. Also I wanted the vac stat on the other side of the system but I know what you mean. Cheers

    • @nunya6081
      @nunya6081 Před 12 dny

      Can still keep the Vac stat on the otherside of the system, just easier so you don’t have to keep removing the schrader from VC2G. Out of curiosity how much were they, might update my Appion and Accutools ones? Love the videos very informative.

    • @maracservices
      @maracservices Před 12 dny

      @@nunya6081 makes sense mate thanks. It was $308. Not the cheapest thing but as soon as I unboxed it, it felt solid. I’m very happy with the purchase.