Station Blackout handling |Blackout Emergency | Boiler & Turbine Emergency| Boiler Turbine tripped

Sdílet
Vložit
  • čas přidán 20. 08. 2024
  • Station Blackout handling |Blackout Emergency | Boiler & Turbine Emergency| Boiler Turbine tripped |
    • Turbine Operation rela...
    / @kpatelbla
    • Boiler MFT on Reheater...
    • Stalling of Primary ai...
  • Věda a technologie

Komentáře • 45

  • @hiranyakishorbarik8305
    @hiranyakishorbarik8305 Před 2 měsíci +1

    Thank you sir

  • @subhlabh9351
    @subhlabh9351 Před 6 měsíci +1

    Very nice sir ji

  • @pjosephkumar
    @pjosephkumar Před 8 měsíci +1

    Well explained sir.. Thank u very much.🙏

  • @Lev-Heart
    @Lev-Heart Před 6 měsíci +1

    Very well explained, thank you Sir

  • @govindsingh-ve2fx
    @govindsingh-ve2fx Před rokem +1

    Crystal clear concepts👌

  • @SantoshKumar-gw2tm
    @SantoshKumar-gw2tm Před rokem +1

    sir Your way of explaining is very simple and easy thnk u so much sir🙏🙏

  • @er.ajeetsahu3046
    @er.ajeetsahu3046 Před rokem +1

    Nice videos sir

  • @SantoshKumar-gw2tm
    @SantoshKumar-gw2tm Před 10 měsíci +1

    Thnk u sir 🙏

  • @arvindshah9748
    @arvindshah9748 Před rokem

    Nice 👍👍 video Sir

  • @pardeeppsiingh7068
    @pardeeppsiingh7068 Před 11 měsíci +1

    Very nice sir 👌

  • @ADILKHAN-tf1bi
    @ADILKHAN-tf1bi Před rokem +1

    thank you sir, for making it so easy to understand.

  • @jitubabusay2826
    @jitubabusay2826 Před 9 měsíci +1

    600 ya 800 ya 500 me ka ek liteup vdo banayiye plz

  • @hanuman5800
    @hanuman5800 Před 8 měsíci +1

    Sir Electrical ka kuchh vedio banae

  • @MahipalGangoliya-xy9hv

    Nicely explained sir... Thanks..

  • @chandrashekhargajbande438
    @chandrashekhargajbande438 Před 10 měsíci +1

    In blackout condition, how will start CO2 evaporator for H2 purge from generator

    • @kpatelbla
      @kpatelbla  Před 10 měsíci

      Good question,
      DG set is provided to charge Emergency MCC and power supply of CO2 evaporator is provided from EMERGENCY MCC.

  • @motive0507
    @motive0507 Před 9 měsíci +1

    emergency drives(Like DC SOP,EOP etc) will run by what .........via Battery?

    • @kpatelbla
      @kpatelbla  Před 9 měsíci

      Emergency drives means DC drives we can run all these by DCDB battery storage power till the start of Diesel generator or normalisation of AC power.

    • @kpatelbla
      @kpatelbla  Před 9 měsíci

      Yes

  • @abhishekmishra-nv3lf
    @abhishekmishra-nv3lf Před 5 hodinami +1

    Sir station blackout me main turbine DC jop ni chalana h?

    • @kpatelbla
      @kpatelbla  Před 5 hodinami

      DC JOP chalana hai, But 600 MW BHEL me both JOP AC Hai I think you get it.

    • @abhishekmishra-nv3lf
      @abhishekmishra-nv3lf Před 5 hodinami +1

      @@kpatelbla sir yha pe one ac or one dc jop h . 600mw BHEL

    • @kpatelbla
      @kpatelbla  Před 4 hodinami

      @abhishekmishra-nv3lf if DC JOP available you have to start it.

  • @ulhaslanke8585
    @ulhaslanke8585 Před 11 měsíci +1

    Sir,
    On which protection generator will trip on occurrence of total ac power supply failure ?

    • @kpatelbla
      @kpatelbla  Před 11 měsíci

      It is the case of Black out mostly this is occured due to Class D protection of Generator.

    • @computercentre12345
      @computercentre12345 Před 11 měsíci

      Class C

    • @ulhaslanke8585
      @ulhaslanke8585 Před 11 měsíci

      @@kpatelbla Sir,
      Could you please pinpoint the name of the generator protection ?

  • @sajidshaikh4503
    @sajidshaikh4503 Před 2 měsíci +1

    Hello sir mai aapke sath Indiabulls power plant Amravati me kam kiya hu

    • @kpatelbla
      @kpatelbla  Před 2 měsíci +1

      Han Sajid, kaise ho ? kanha ho aajkal,?

    • @sajidshaikh4503
      @sajidshaikh4503 Před 2 měsíci +1

      Sir mai theek hu, abhi telangana me 2x600 MW Singareni power plant me

    • @sajidshaikh4503
      @sajidshaikh4503 Před 2 měsíci +1

      Abhi recent BOE exam pass hua hu Karnataka se

    • @sajidshaikh4503
      @sajidshaikh4503 Před 2 měsíci

      Bahut important topic hai sir video ka😊😊😊

    • @kpatelbla
      @kpatelbla  Před 2 měsíci

      @@sajidshaikh4503 congratulations 👍

  • @NareshKumar-wv3te
    @NareshKumar-wv3te Před 9 měsíci +1

    Sir how to handle fire in lube oil in turbine emergency

    • @NareshKumar-wv3te
      @NareshKumar-wv3te Před 9 měsíci +1

      If we stop lube oil pump does bearing damage in coasting time what's the action to be taken

    • @kpatelbla
      @kpatelbla  Před 9 měsíci

      Depends upon the severity of fire in most worst case manually trip the unit take help of fire & safety department for extinguish for and transfer the lube oil in drain oil station.

    • @kpatelbla
      @kpatelbla  Před 9 měsíci +1

      @@NareshKumar-wv3te normally we have to avoid it but in worst case of fire in lube oil we can take this step to avoid other major damage due to fire.

    • @NareshKumar-wv3te
      @NareshKumar-wv3te Před 9 měsíci +1

      If lube oil is stopped only babit damage in coasting time or it may damage bearing and lead to fire due to friction

    • @kpatelbla
      @kpatelbla  Před 9 měsíci

      @@NareshKumar-wv3te it can damage babbit metal.

  • @kamaldeshmukh3052
    @kamaldeshmukh3052 Před rokem +1

    Thank you sir