Power Plant Operation discussion

Sdílet
Vložit
  • čas přidán 20. 08. 2024
  • Power plant operation discussion

Komentáře • 17

  • @abhishekpandey8773
    @abhishekpandey8773 Před 4 měsíci +2

    Superb Superb 👌👌We all need more interview Q&A Videos..Plz Uploade more video on Q& A

  • @creativephysicsbymansibhar3003
    @creativephysicsbymansibhar3003 Před 4 měsíci +1

    nice sir ✌️✌️👏👏🙏

  • @swapnil1321
    @swapnil1321 Před 4 měsíci

    Your videos help us all

  • @aravindhkumar2380
    @aravindhkumar2380 Před 3 dny

    Dear sir,
    Please make one video on bottom ash controlling by adjusting of SADC dampers by using high GCV and LOW GCV coal and different combinations of mill.

  • @aravindhkumar2380
    @aravindhkumar2380 Před 3 dny

    Hi sir...i am working in 150MW plant operation my question is what is pressure and temperature of LP turbine.

  • @computercentre12345
    @computercentre12345 Před 4 měsíci +1

    During boiler purging if total air is less than 30 percent then unburnt fuel not removed completely.
    If total air more than 40 percent. It will extra cool the furnace.
    So 30 to 40 percent.
    Am I right sir?

  • @computercentre12345
    @computercentre12345 Před 4 měsíci +1

    Sir in ehtc position set point command EHC1 2 Constant.
    But feedback hunting and corresponding hp sec oil pr hunting load hunting.

    • @kpatelbla
      @kpatelbla  Před 4 měsíci

      Load hunting absolutely occurred if HP sec oil pressure hunting takes place.

  • @MuhammadIlyas-tq8ch
    @MuhammadIlyas-tq8ch Před měsícem +1

    Sir when Anand chtervedi enters in session, we can see smile on your face. Is he special person? 😅😂

  • @ramashankarvaishy
    @ramashankarvaishy Před 4 měsíci +1

    Sir Turbine hp rolling and ip rolling ke merit and demerits kya hai.

    • @kpatelbla
      @kpatelbla  Před 4 měsíci

      Only facilitate Turbine internal soaking no merit demerits are there.

  • @computercentre12345
    @computercentre12345 Před 4 měsíci +1

    Why in litup lpbp hrh pr maintained 6 to 8ksc. But not 12 or above

    • @kpatelbla
      @kpatelbla  Před 4 měsíci +1

      To avoid turbine valve throttling and provide better soaking of Turbine.

  • @jitubabusay2826
    @jitubabusay2826 Před 4 měsíci

    Drip pump kisliye hai plz bataiyega?

  • @The_commannazariya.
    @The_commannazariya. Před 4 měsíci +1

    Sir I got 5year of experience in boiler but every time while operation mai bohot kuchh bhool jata hu isko kaise improve kare?

    • @kpatelbla
      @kpatelbla  Před 4 měsíci

      Attend today live at 23:15 Hrs