Power plant operation Q & A part 2

Sdílet
Vložit
  • čas přidán 20. 08. 2024
  • Power plant operation Question & Answer part 2

Komentáře • 30

  • @user-fr4rm2ih9n
    @user-fr4rm2ih9n Před 3 měsíci +1

    Nice explanation sir thank you

  • @sarottamcreation5180
    @sarottamcreation5180 Před 10 hodinami +1

    Sir kindly explain about DO and Ph @ stator water and cupric oxide also explains

  • @user-sc7xz4mg9j
    @user-sc7xz4mg9j Před 3 měsíci +2

    G.n sir

  • @shailendrasinghpatel1427
    @shailendrasinghpatel1427 Před 3 měsíci +1

    Sir make a live video class for governing system

  • @gauravkr067
    @gauravkr067 Před 3 měsíci +1

    Water chemistry k bare m bataiye sir kitna ph, iron, turbidity, TDS conductivity maintain karte hai dm water m. Lightup k time water chemistry kiya maitain karte hai, CPU kab line m lete hai, function of CPU, COC of cooling tower kitna maintain karte hai or kyu?

  • @user-fr4rm2ih9n
    @user-fr4rm2ih9n Před 3 měsíci +1

    Sir ek vedio interview questions list par banaiye please

    • @kpatelbla
      @kpatelbla  Před 3 měsíci

      Ok, next live will be about it.

  • @computercentre12345
    @computercentre12345 Před 3 měsíci +1

    For improving flame intensity what ahould command given in SADC.
    IS ryt approach to closed bofa

    • @kpatelbla
      @kpatelbla  Před 3 měsíci +1

      I have explained this topic in detail video watch this one and ask question in comment section czcams.com/video/UJXbBqc1bDg/video.htmlsi=OresJzHxiP2a9dmZ

  • @computercentre12345
    @computercentre12345 Před 3 měsíci +1

    Sir for C elev voted second condution
    Feeder c service and CD elevation oil gun in service and 110v ac power failure.
    Is feeder c service necessary for acting C voted.
    If feederC not in service and (Cd gun service and 110V AC fail) then also C should voted?

    • @kpatelbla
      @kpatelbla  Před 3 měsíci

      Feeder C should proven for more than 2 second to arm NO FLAME VOTING CONDITION

  • @Ranjitamaharana-xu6sg
    @Ranjitamaharana-xu6sg Před 3 měsíci +1

    Sir please make video for Boiler and Turbine Emergency Handling

    • @kpatelbla
      @kpatelbla  Před 3 měsíci +1

      Live stream already available on my channel

  • @computercentre12345
    @computercentre12345 Před 3 měsíci +1

    Sir why hotv lotv has 220v DC power not 110v AC power?

  • @0503manoj
    @0503manoj Před 3 měsíci +1

    Sir
    Hotv me kitna volt supply hota hai
    Aur
    Lonv m kitna volt supply hota hi

    • @kpatelbla
      @kpatelbla  Před 3 měsíci

      LOTV 220 v DC., LONV 110 Volt AC

    • @abhishekmishra-nv3lf
      @abhishekmishra-nv3lf Před 3 měsíci +1

      Why lovt hotv220 Dc and lonv and honv 110v ac sir

    • @kpatelbla
      @kpatelbla  Před 3 měsíci

      @abhishekmishra-nv3lf it is to initiate MFT in case of 110 Volt AC failuire

  • @Ranjitamaharana-xu6sg
    @Ranjitamaharana-xu6sg Před 3 měsíci +1

    Sir If One Vacuum pump in Permit and at that time other running Vacuum is Trip then what will be action taken at that time.

    • @kpatelbla
      @kpatelbla  Před 3 měsíci

      If there is only two vacuum pump then immediately reduce load to save unit corresponding to vacuum.

    • @abhishekmishra-nv3lf
      @abhishekmishra-nv3lf Před 3 měsíci +1

      Load reduced 40 percent

    • @vikaskumar-fq4uy
      @vikaskumar-fq4uy Před 3 měsíci +1

      ​@@kpatelbla
      Sir i think unit will be trip on high vaccum in case of vaccum pump tripped

    • @kpatelbla
      @kpatelbla  Před 3 měsíci

      @vikaskumar-fq4uy if this is for more than 15 minute.

    • @vikaskumar-fq4uy
      @vikaskumar-fq4uy Před 3 měsíci +1

      @@kpatelbla sir but vaccum will drop very fast, I don't think that it will take 15 minutes