Walk In Freezer Warm Since Yesterday!?

SdĂ­let
VloĆŸit
  • čas pƙidĂĄn 9. 07. 2024
  • Walk-in freezer had gone into an alarm yesterday and I was there to find out why. Let's look for what could have caused it and fix it!
    - Purchase your tools at www.trutechtools.com/?AffId=42 and use the offer code SURVIVAL to save 8% on your total purchase (exclusions apply) -
    - TOOLS I USE -
    kit.co/hvacrsurvival
    Magnetic solenoid tester. amzn.to/32TGXlH
    đŸ’„ Amazon Store: www.amazon.com/ref=as_li_ss_t...
    - CONTACT INFO -
    hvacrsurvival@gmail.com
    - FOLLOW ME -
    Instagram - / hvacrsurvival
    Facebook - / hvacrsurvival
    - SUPPORT THE CHANNEL -
    www.paypal.me/RickDirmeyer
    Warning Notice Disclaimer - Video content listed on the channel HVAC*R Survival is for entertainment purposes only and not meant to be a substitute for not contacting a competent HVAC/R PROFESSIONAL. Do not attempt anything said or seen on my videos, The tasks that are shown are dangerous and deadly without proper training.
    This page contains affiliate links, which means that if you click on the link and make a purchase, I’ll receive a small commission. HVAC/R Survival is a participant in the Trutechtools, Fenix-Store & Amazon Services LLC Associates Program.
    #hvacrsurvival #hvaclife #hvacservice #hvacr #refrigeration #troubleshooting
    00:00 Tru Tech Tools
    00:13 Todays Call is a warm freezer
    01:04 refrigerant leak search with the Inficon stratus
    01:36 Emerson e2 controller history
    02:33 first large refrigerant leak
    04:02 finding residual leaks up high
    04:51 still leaking after tightening the refrigerant cap
    05:20 changing the refrigerate Schrader core
    05:58 Knipex plyers wrench
    07:01 testo digital wireless refrigerant scale
    09:20 remove from defrost
    10:31 found another refrigerant leak
    12:42 navac NEF6LM automatic flare tool
    13:50 how to properly flare a fitting
    15:56 no valves to use a vacuum pump this is the only choice
    20:03 final leak checking
    21:23 looking high and low for additional refrigerant leaks
    21:34 change the refrigerant drier anyway
    23:48 final checks on the E2 controller
  • ZĂĄbava

Komentáƙe • 117

  • @jaymartin5095
    @jaymartin5095 Pƙed 3 měsĂ­ci +1

    Exemplary thoroughness. Thanks for your example and for the effort to educate.

  • @MattTrevett
    @MattTrevett Pƙed rokem +6

    When you removed the schrader cap I could hear hissing each time. Nice find.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +3

      You have better ears than me, wear your hearing protection if you want to keep it. (I have ringing all the time and testing shows I have lost a little hearing. )

  • @joshwf41
    @joshwf41 Pƙed rokem +2

    Should have pulled the charge, R404A is a zeotropic blend and may not perform as well as with a virgin charge of R404A. This means that the mixture of gases in the refrigerant will boil off at different rates so when a leak happens one or more of the blend will leak out before the other resulting in a system that does not perform well.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      That was a concern in the beginning but hasn't panned out from what I have experienced. I have had that happen with R410a, but not with any of the other blends.

  • @mainj54
    @mainj54 Pƙed rokem +5

    Top notch service. I hope you are paid well. Your attention to detail is exemplary.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +4

      I get paid better here than I have any place at work. Thanks for the support !đŸ€œđŸ€›đŸ‘đŸ‘

  • @briancarlisi2224
    @briancarlisi2224 Pƙed rokem +14

    Interesting video. Thank you. I’m impressed by the craftsmanship of the pipe work by the installer. Actually the whole facility looked top notch.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +4

      They work for the store but he sold his business to them. They do nice work.

    • @Ismael72110
      @Ismael72110 Pƙed rokem +1

      @@HVACRSurvival i wonder how is the battery life in this updated version of testos cause first gen eat batteries like there’s no tomorrow

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +1

      Don-I believe they are good so far, I don't leave them on all the time but I can get two or more months out of the batteries. I actually think I've gotten 4-6 months. But I use the 5 min was auto off.

  • @HEFTYLEFTY303
    @HEFTYLEFTY303 Pƙed 9 měsĂ­ci +1

    I love how you said you see how those are flat 😅

  • @refrigerationconfidential4376

    Awww that sweet E2

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      Yep, I like that better then the Danfoss I seen.

  • @glenjones4404
    @glenjones4404 Pƙed 3 měsĂ­ci +1

    My favourite compressor is frascolds as they can take a lot of stick and are suction cooled not fan cooled like prescold and Copeland's
    Plus frascolds are a bit cheaper than the makes of semi hermetics but I've worked on all makes of compressors tbf in my lifetime

  • @scottdavis6717
    @scottdavis6717 Pƙed rokem +1

    Now we know why sight glass is yellow. There was no pressure on half inch line so guarantee air in system now. You pumped down using king valve, could have easily pulled vacuum using suction schrader.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      The moisture indicator was like that prior to me getting there and I didn't pump it into a negative prior to repairing it so I disagree. I changed the drier and purged the line after the repair, there's not much more you can do to dry up the system other than keep changing driers.

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC Pƙed rokem +2

    I love the Stratus. Thanks again for answering all my questions about it.
    Another great job at being precise, using the E2 to let you know the issue and implementing a proper repair

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      I'm glad you like it man! Thanks for the feedback!

  • @toddmaxwell9803
    @toddmaxwell9803 Pƙed rokem +8

    To get it out of defrost faster, you can select "clean" then "end manuel mode"..goes right back into refrigeration

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +4

      I've never tried using that? I'll see if that's an option on the ones we use. Thanks for the info! 👍👍

  • @coldfinger459sub0
    @coldfinger459sub0 Pƙed rokem +1

    Our old hands , wrist and tendons I really love all these new NAVAC swage and flare and the Milwaukee battery powered tubing cutter of course Purchased at True Tech Tools 👍

  • @punchpunchowned
    @punchpunchowned Pƙed rokem +2

    Can you explain a little bit more on how you didnt vacum that part of the system? I didnt completly understand. Thanks.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      Next time when you unhook your gauges watch for refrigerant to boil off from your hose. You'll see what I'm talking about, hold it up to a bright background and look through the distortion from the refrigerant.

  • @Samuel-xb8ti
    @Samuel-xb8ti Pƙed rokem +1

    End of the field piece of equipment I know you might prefer the stuff that you use but try it out and I bet you it will change everything

  • @juliochavez4028
    @juliochavez4028 Pƙed rokem +1

    That’s a good find, since it’s not a rack system I’d agree on the shrader valve being the leak in the system, if it was a rack I’d definitely suggest a more thorough leak search

  • @berylwhite2983
    @berylwhite2983 Pƙed rokem +1

    I totally agree with you a lot of little buckets can carry out more than one very large bucket.. you did a great job! You went far above and beyond going up that ladder. Be careful and remember you are a Craftsman everybody should be proud of you.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      You're too kind! Thank you for all your support!

  • @kpc5
    @kpc5 Pƙed rokem +1

    Really good videos, and i like the fact you do not replace parts that were not needed that were not in the quote.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      Thanks! I enjoy the hunt for the real problem👍👍

  • @sterlingarcher46
    @sterlingarcher46 Pƙed rokem +1

    by the way : no vac = Super Tech badge pulled Sir ! And I'd like to speak to the manager please ( I couldn't find a Karen emoji though...).

  • @xishxander8510
    @xishxander8510 Pƙed rokem +1

    Quality video. Making it look easy.

  • @MikeB9771
    @MikeB9771 Pƙed rokem +1

    You're the man Rick!

  • @Eddy63
    @Eddy63 Pƙed rokem +1

    Good job as usual and good vid Sir ... Thx for sharing ...

  • @thesilentonevictor
    @thesilentonevictor Pƙed rokem +1

    Great work finding the leak

  • @billmiller5075
    @billmiller5075 Pƙed rokem +1

    Nice work

  • @tcstom1243
    @tcstom1243 Pƙed rokem +4

    Great looking refrigeration install. Don`t see that to much any more. And they know how to use a bender to eliminate joints when possible. Today all ya see are line sets that generally look like crap. If you noticed your leaks except for the flair was in valves and schraders . Perhaps the manufacturers need to step it up a bit. Nothing like having valves to isolate system components. Great job on your patience to keep checking for those nasty leaks

  • @hvacrnortheastern2110
    @hvacrnortheastern2110 Pƙed rokem +1

    Your getting comfortable with refrigeration system from last year that flaring tool is awesome l wish l had tool when l was in a service van.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      I am getting better in the grocery stores, but I still don't have all the answers for stuff I haven't worked on yet.

  • @harrydickson4575
    @harrydickson4575 Pƙed rokem +3

    Excellent job 👍👍👍

  • @gregmiracle9560
    @gregmiracle9560 Pƙed rokem +1

    Just an idea ... Do like acservicetech take the brass caps drill a small hole in center put on shrader and you can apply the bubble solution to the tip of cap at hole and not fill shrader hole! Lol just sharing! Good work! Stay safe! 👍👍

  • @rookierefrigeration4357
    @rookierefrigeration4357 Pƙed rokem +1

    Good job bro. Good to see you’re still making videos.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      Thanks Rookie! I hope you're doing well my man!

  • @r1cky42
    @r1cky42 Pƙed rokem +1

    Nice video I been in refrigeration for a year now and I’m still learning

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      Awesome, it's a great career choice👍👍

  • @HVACGUY
    @HVACGUY Pƙed rokem +1

    Love that leak detector

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      I've been impressed, I did a lot of testing prior to switching to it.

  • @richvacrdyazhi5532
    @richvacrdyazhi5532 Pƙed rokem +1

    Great job man!

  • @EverythingHVACR
    @EverythingHVACR Pƙed rokem +2

    Nice job Rick!

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +1

      Thanks Steve, dang computer crashed and couldn't get it to reload my editing software until late yesterdayđŸ€ŠđŸ». It's still locking upđŸ˜©

  • @nickcampbell8096
    @nickcampbell8096 Pƙed rokem +1

    very thorough leak search, nice work đŸ€˜

  • @xelaju8
    @xelaju8 Pƙed rokem +1

    Awesome video again. Thanks for posting and I will definitely use your code for True Tech Tools next time.

  • @leonardolimon8371
    @leonardolimon8371 Pƙed rokem +1

    Nice

  • @Freezier134a
    @Freezier134a Pƙed rokem +1

    That flaring tool is awesome! I may have to look for one at some point! Great work as usual!

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +1

      It's not cheap but if you do a lot of mini splits or flare fittings it definitely can save you time.

    • @Freezier134a
      @Freezier134a Pƙed rokem

      @@HVACRSurvival I don’t to a ton of them, but I do love tools that make my job easier!

  • @shine-cg9uf
    @shine-cg9uf Pƙed rokem +1

    👍đŸ’Ș❄đŸ‡ș🇾 Nice work 🙏

  • @awyeh1234
    @awyeh1234 Pƙed rokem +1

    We have the navac at work best tool we own so much more efficient than hand flaring

  • @Syphonfllter
    @Syphonfllter Pƙed rokem +1

    Had a handful of Schraders go bad on me lately, and the stems were bent and would get caught on the access fitting, I had to install swivel tees in some cases where I couldn't get some out. Don't know why they'd become bent outta shape like that but it happens, oh and loose packing nuts ahd bad flares.. I started using these blue caps you put inside flares, seem to work pretty well still use nylog on the rim and threads though.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      Thanks for sharing👍👍

    • @Syphonfllter
      @Syphonfllter Pƙed rokem +1

      @@HVACRSurvival sure thing, I've only been on the field about a couple years now since I transitioned from ammonia, so your videos are super informative for me at this point. I recognize a lot of the equipment you work on so its much appreciated.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      Awesome to hear! Thanks!

  • @andrewedis9907
    @andrewedis9907 Pƙed rokem +1

    That's a fancy flaring 🔧 tool 🔧

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +1

      It's fast and almost error free. I don't do a lot of flares but I mainly wanted to show it to my company's install manager. Install has to many service calls for leaking flares.

  • @johnwalker890
    @johnwalker890 Pƙed rokem +1

    Good job Rick, I guess that flare tool is worth the money.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      If I was the business owner and had the call backs that I see happening, that tool is a wise investment to make the job as brain dead as possible to prevent callbacks.

    • @johnwalker890
      @johnwalker890 Pƙed rokem

      I hear you.

  • @Beko500ProGolover
    @Beko500ProGolover Pƙed rokem +2

    I ask what type of compressor is that. Is it a scroll compressor?

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      That's a Copeland semi hermetic compressor. I don't remember exactly how many horse but it's probably 5 or 7.5

  • @CallsignMayhem
    @CallsignMayhem Pƙed rokem +1

    Nice work. Purge > vacuum all day.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      I'll catch some crap about it I'm sure. But that's why I brought it up before they do and showed there wasn't a easy way to do it without adding a refer port.

  • @DanO181919
    @DanO181919 Pƙed rokem +2

    Maybe I missed it but you were about to explain what the purpose of the fan on top of the compressor is for.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +2

      I butchered the wording so I cut it. Basically the compression ratio on a freezer compressor is a lot more than a cooler commodity, so the heads run hotter, the fan helps keep it cooler. Sometimes they will use direct liquid injection to help cool the head instead.

    • @DanO181919
      @DanO181919 Pƙed rokem +2

      @@HVACRSurvival Thank you.

  • @MichaelBartonMTS
    @MichaelBartonMTS Pƙed rokem +1

    Awsome Job, Just got the Testo 557s Kit, Ill have to grab that scale next!
    Any other good Testo tools I should grab?

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      That's the only new stuff I have from them. I like the Testo manifolds better but I like the Fieldpiece for my gas and static pressure gauges.

  • @edorofish
    @edorofish Pƙed rokem +3

    20:44 would a telescoping pole work? For a quick check?

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +2

      You know I never thought of it...yeah you could do that👍👍. I would n need to have something on the truck that I could do that with. Maybe one of those things they use for light bulbs. It's not often that I have to search like that but there are times.

  • @Samuel-xb8ti
    @Samuel-xb8ti Pƙed rokem +1

    Why don’t you use a fieldpiece scale

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      I tried working a deal out with Fieldpiece BUT there girl in marketing snubbed me so I'll try out the equipment Testo sends me. I have Fieldpiece stuff, some is great and some is junk, same with Testo. No-one make everything great...

  • @SombraLocs
    @SombraLocs Pƙed rokem +1

    That flaring tool is too bulky. No way I would buy something to take up more space than necessary in my van.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +1

      It's really more useful for people that are using it for a large multi head mini split install and installers that don't know how to make flares that end up leaking then casing a call back.

    • @smithno41
      @smithno41 Pƙed rokem

      But the time you save on a large job with a lot of flares is worth it, IMHO

  • @Irilia_neko
    @Irilia_neko Pƙed rokem +2

    I'm surprised the computer haven't start an alarm as soon as the graph was changing

    • @lathiat
      @lathiat Pƙed rokem +2

      Watching HVACR videos and being an IT guy we graph everything. Drives me crazy they don’t even have a basic graph like this one does. Let alone an alarm. The tech for the basics is not at all expensive. I think I saw one AC controller that worked like that only.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +2

      This Emerson controller is the industry standard for grocery stores, I'm not sure why they didn't tie this in next door to the main store network that is monitored.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +1

      I don't think it's on the network like the main store.

    • @Irilia_neko
      @Irilia_neko Pƙed rokem +1

      @@HVACRSurvival don't even need to be on the network a 3 light poles green orange red is enough. Orange you contact the technician, very simple

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +1

      This was a remote building to the grocery store, they only use it for cooking and no customers are in it. So no one would even see the lights in that building. Just run a CAT5 cable over to our other real racks and tie it in

  • @anthonyaldridge
    @anthonyaldridge Pƙed rokem +1

    Perhaps the gasket has just given up over time due to heating and cooling of the unit cycling or vibrations.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem +1

      That's about the only logical thing I can come up with.

  • @markcarpenter3600
    @markcarpenter3600 Pƙed rokem +1

    You can drill a small hole in the end of a cap to test schrader ports. With small amount of bubble leak detector applied to the cap with a finder the it won't go into the port at all. Also for larger leaks you can use Nylog as a test liquid.

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      That's a good idea on the hole in the capđŸ€œđŸ€›đŸ‘đŸ‘

  • @steveblake8766
    @steveblake8766 Pƙed rokem +1

    194 thumbs up

  • @joeshearer1247
    @joeshearer1247 Pƙed rokem +1

    I get on everything with my cobra’s and yea it leaves teeth marks but who cares to be honest?

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      I care đŸ€ŁđŸ€ŠđŸ», those weren't the cobra's, are you missing with me? 😳

  • @sterlingarcher46
    @sterlingarcher46 Pƙed rokem +1

    " insert tool company name here " : dumbing down the industry one electronic tool at a time ... Next step : Uber hvac coming to you !

  • @kentdaily7107
    @kentdaily7107 Pƙed rokem +1

    cut out those allways leaking flare fiiting pooooor skills

    • @HVACRSurvival
      @HVACRSurvival  Pƙed rokem

      Poor skills are why It was leaking. People just don't care anymore.