  • @SC-bg8wf
    @SC-bg8wf Před měsícem +1

    I changed the whole pcb and it fixed my problem but I wish I'd watched this video sooner and I'd have tried changing just the capacitor.

    • @proexservis
      @proexservis  Před měsícem

      Glad to hear that it helped you, but sorry for that at the same time, if it was your case, that you had only faulty capacitor.
      That one video (which you find first) is older (almost half year later I was able to confirm this solution, turning off problem is caused by capacitor) and usually for ppl who dont have soldering gun or are unable to replace just the capacitor is better to replace whole board.
      How old is your UltraSilencer vacuum cleaner?

  • @fbjon
    @fbjon Před 7 měsíci +2

    I had exactly the same issue on a PD82-green Electrolux vacuum. Replacing the 334k x2 capacitor fixed it. The electrolytics were also somewhat out of spec, but replacing them (first) didn't seem to have any effect.

    • @proexservis
      @proexservis  Před 7 měsíci +1

      Yes, most of the time it helps to fix this issue, sometimes both capacitors are faulty.
      Do you have this vacuum cleaner always in-plug?

    • @fbjon
      @fbjon Před 7 měsíci +1

      @@proexservisIt's usually only plugged in when used, but occasionally it might stay plugged in and laying around. Would transients in the power grid or something like that cause failure of the filter cap?

    • @proexservis
      @proexservis  Před 7 měsíci +1

      @@fbjon i had few vacuum cleaners here (2-4y old and almost always in-plug) and all had this issue, so it can cause it, depends on grid.

  • @MiracleMiraculeux
    @MiracleMiraculeux Před 6 měsíci +2

    Comment on teste la carte électronique merci

    • @proexservis
      @proexservis  Před 6 měsíci +1

      Vous pouvez le mesurer pendant le fonctionnement, si l'aspirateur ne fonctionne pas du tout, vous pouvez mesurer le câble de l'enrouleur de cordon et du moteur sur les contacts du PCB. Généralement, si ce condensateur est défectueux, l'aspirateur s'éteint après un certain temps ou à une puissance plus élevée, le condensateur ne peut donc pas maintenir la tension.
      You can measure it during operation, if vacuum cleaner does not work at all you can measure cables from cord winder and motor on PCB contacts. Usually if this capacitor is faulty, vacuum cleaner is turning off after a while or on higher power, so capacitor cant hold voltage.

  • @vodussek
    @vodussek Před 7 měsíci +2

    Hello, I have the same problem as you decribed - its working, and sometimes works for 30seconds and when I move vacuum cleaner stops working or sometimes only after few seconds. Can you tell me, what is the part you changed, so I can find it on internet? Thank you for your help

    • @proexservis
      @proexservis  Před 7 měsíci +2

      Hello, if you are not able to repair your circuit board then you have to replace board 1181970391 (if you have UltraSilencer model without remote control handle).
      If you are able to repair it then you need capacitors 334(K) X2 and maybe 224(K) X2 too.

    • @vodussek
      @vodussek Před 7 měsíci +2

      @@proexservisThank you for your answer - first I will open it, and see what is wrong because the whole board is around 45€, for sure it would be cheaper just to change capacitor.
      Thank you for your help, I will contact you If I have some more questions :)

    • @proexservis
      @proexservis  Před 7 měsíci +1

      @@vodussek cheaper board is from UltraOne model (1181970094 - compatible with UltraSilencers), but then range of suction power will be only from half to max, because from half to minimum is still minimum.

    • @vodussek
      @vodussek Před 7 měsíci +2

      @@proexservis Good to know, most of the time I have full power suction, so I don't mind if suction starts from falf to max. Thank you for you answer, and all your help!

    • @JanNordqvistLinkoping
      @JanNordqvistLinkoping Před 7 měsíci +2

      Thank you for telling how to open the case! For me it was the very small tactile switch (6 x 6 mm) for on/off that where faulty. Power on worked sometimes and also the power could go off randomly.