How to "Top Off" Your Vehicle's A/C (With Self-Sealing Cans)

Sdílet
Vložit
  • čas přidán 10. 10. 2020
  • Today I recharged the air conditioning on my '95 Ford Ranger. In this video, I explain how to know if your A/C needs to be recharged. It's very important to understand that you can only "top off" your air conditioning IF your system has some charge in it. If you do not, you will have to vacuum THEN recharge your air conditioning. I also talk about the tools needed to complete the job. I explain the use of the new self-sealing cans that are needed, and why you need a proper set of gauges. The same steps should apply to any make and model with an R134 system.
    As an Amazon Associate I earn from qualifying purchases, at no extra cost to you. Thanks for supporting the channel.
    A/C Pro Self-Sealing Can Tap
    amzn.to/2MSsEWq
    A/C Pro Recharge Hose (For Self-Sealing Can)
    amzn.to/3sOw7Ve
    Yellow Jacket R22, 134A, 404A Gauges
    amzn.to/3e8Gfnx
    Taylor Instant Read Pocket Thermometer
    amzn.to/3sS8zyU
    Elitech Refrigerant Leak Detector
    amzn.to/3c78r7R
    A/C Pro Leak Detection Kit
    amzn.to/3e7JlIB
    FJC Oil and Dye Injector
    amzn.to/3e8GPSf
    Due to factors beyond the control of NutsAndBoltsAuto, it cannot guarantee against unauthorized modifications or improper use of this information. NutsAndBoltsAuto assumes no liability for property damage or injury incurred as a result of any of the information contained in this video. No information contained in this video shall create a guarantee, expressed or implied, of a particular result. Any injury, damage, or loss that may result from improper use of these tools, equipment, or the information contained in this video is the sole responsibility of the user and not NutsAndBoltsAuto
  • Auta a dopravní prostředky

Komentáře • 34

  • @NutsandBoltsAuto
    @NutsandBoltsAuto  Před 3 lety

    Here's some stuff you may need:
    A/C Pro Self-Sealing Can Tap
    amzn.to/2MSsEWq
    A/C Pro Recharge Hose (For Self-Sealing Can)
    amzn.to/3sOw7Ve
    Yellow Jacket R22, 134A, 404A Gauges
    amzn.to/3e8Gfnx
    Taylor Instant Read Pocket Thermometer
    amzn.to/3sS8zyU
    Elitech Refrigerant Leak Detector
    amzn.to/3c78r7R
    A/C Pro Leak Detection Kit
    amzn.to/3e7JlIB
    FJC Oil and Dye Injector
    amzn.to/3e8GPSf

  • @wbwright79
    @wbwright79 Před měsícem

    this is quite possibly the most thorough instructional (which covers most of the small details which others omit) that i have ever watched. for the average garage mechanic (who only has the short hose/gauge), pay attention to every bit of this video.

  • @trackerrrr
    @trackerrrr Před 20 dny

    Just did this today with 12 oz can and a hose. Got my A/C outlet temp down to 36 degrees F which is damn cold!

  • @Achilles3588
    @Achilles3588 Před rokem +1

    Really thorough mate. Good job!

  • @johnstone4020
    @johnstone4020 Před 3 lety +4

    Great video! You explained how the A/C system works in a simple and easy to understand way for the DIYer.

  • @dwhallon21
    @dwhallon21 Před rokem

    Great video, excellent details.

  • @garryrobinson364
    @garryrobinson364 Před 2 lety +1

    Thank you for a excellent diy video!! I am now a new subscriber

  • @IntheBlood67
    @IntheBlood67 Před rokem

    Most Excellent!

  • @voiceofreason891
    @voiceofreason891 Před 11 měsíci +3

    You can purge the line if you have the can connected (but not depressing self-sealing valve) and the low-side adapter connected to the car (if there is still any pressure in the system). Just unscrew the can a bit to use the car's pressure to purge the line.
    I would also not hold the can upside down very long because too much liquid with enter the system and slug the compressor. Best to rock it slowly, or if you have patience, just let it enter slowly with the can upright (enters as vapor, not liquid). As long as there is liquid in the can it will keep a constant pressure and should enter the system on the suction side.

    • @wbwright79
      @wbwright79 Před měsícem +1

      yep. purging the hose/gauge line is important. as you mention, all you need to do is unscrew the connected CAN from the hose a second to listen for the hiss, and the air will be gone.

  • @u.s.a.198
    @u.s.a.198 Před 2 lety

    Ty... great video..

  • @MarkSchuster-ym3iy
    @MarkSchuster-ym3iy Před 10 měsíci

    Good video thanks

  • @soldiersvejk2053
    @soldiersvejk2053 Před 2 lety

    Thanks!

  • @mcamodell
    @mcamodell Před 2 lety +4

    It's also important to note that all the cheap Self-Sealing Chinesium taps that are the right threading to fit Chinese hoses are old spike types that have had the spike ground off... making them now too short to actually open the Self-Sealing cans, buyer beware

  • @peteraustin767
    @peteraustin767 Před 2 měsíci

    Thanks

  • @arturomejia629
    @arturomejia629 Před 9 měsíci

    Great

  • @bbmd2200
    @bbmd2200 Před 2 lety

    Hello. Does the valve need to be all the way out for the refrigerant to flow or all the way in? Thank you.

  • @andyrosco
    @andyrosco Před rokem

    An additional note... the Can taps have either a 1/2" Acme thread or a 1/4" flare male outlet. The manifold gage tube either has a 1/2" Acme thread or a 1/4" flare female fitting. But the 1/4" flare will not connect to the 1/2" Acme thread without a special brass fitting adapter. Usually the adapter is a separate purchase.

  • @mistersecret88
    @mistersecret88 Před rokem +1

    I don't know why you would pierce the csn without connecting it to low side first

  • @mr_mnky
    @mr_mnky Před rokem

    Does that A/C Pro tap have a check valve? The cheap 'surebilt' brand tap I got at autozone doesn't have a check valve. When you need to swap cans, you end up having to open up the 'yellow' charging hose to the atmosphere, so you lose all of the refrigerant & get air in the line, forcing you to have to purge it again, which sucks.
    There's a ChrisFix vid on how to charge A/C, where he uses a tap with a check valve (for traditional puncture cans) that keeps the yellow hose+tap sealed off while he swaps cans. How would you do this with the self-sealing cans? All of the taps I've seen appear to use the same cheap 'faucet' design & don't have a check valve (I don't believe)

  • @trentvoc4229
    @trentvoc4229 Před 10 měsíci

    I used the single gauge short hose to test my static pressure and it came in what I beleive is low for 85 degrees, at 65 lbs. When I removed the hose from the port it was minor-leak wafing bubbles in the valve. Does this mean I have water in my system?

  • @tribesascendvideos3186
    @tribesascendvideos3186 Před rokem +1

    $5.99 for those cans? Wow. The good ole days

  • @mcamodell
    @mcamodell Před 3 lety +1

    EPA made the sealing cans mandatory nationwide, you need a Self-Sealing Can Tap to use any new cans

    • @mcamodell
      @mcamodell Před 2 lety +2

      It's also important to note that all the cheap Chinesium taps are old spike types that have had the spike ground off... they are now too short to actually open the sealing cans, buyer beware

  • @Msleelee9487
    @Msleelee9487 Před 3 lety +2

    i wished i would have watched this before i used that stuff my a/c got cold for about 3 wks and it stop blowing cold and the fan i don't here it kicking in i know if i take it to the shop they will charge 3000 dollars one shop cleared my codes and charged 380 dollars and i took it back when the light came on and the guy said give it time it will go off so i took it out of town and they kept my jeep 2wks and charged me 1800 dollars that's why i started working on my car i do my own oil changes got to do one tomorrow but gotta figure out this a/c thing but not so much it's getting cooler but don't no it i have heat hmmm

    • @jonathandavid3632
      @jonathandavid3632 Před rokem +1

      Sometimes a trick to deal with those lights is to remove BOTH battery poles off over night..

  • @thelockpickinglebowski633

    I don't think the can is supposed to be turned upside down. That sends the contents out as a liquid.

  • @randallmontejano7787
    @randallmontejano7787 Před 3 lety +1

    F for the compressor

  • @josephnovak5808
    @josephnovak5808 Před rokem +1

    Find the leaks should not have to add

  • @beast_0012
    @beast_0012 Před 3 lety +3

    Belt go VROOOOOOOOM

  • @davidsolloway9349
    @davidsolloway9349 Před 10 měsíci

    like # 555.