(YouTube First!) Fire Service Mode Phase 1 & 2 On a New Schindler 3300 | Elevator Fire Service Demo

Sdílet
Vložit
  • čas přidán 11. 09. 2024
  • I did forget to mention one thing and that was the fact that if you press call cancel as the elevator is moving, it will stop at the closest floor in its direction of travel. Still pretty good for a first time though. Hope you enjoyed this demo on a newer 3300 as I've searched far and wide and only found a phase 1 demo done at a hotel.
    NOTE: This was done in a private building with proper authority. DO NOT use or attempt to use elevator keys without permission from the building owner, management, or a licensed elevator technician.
    Huge thanks to Shawn (the building manager) for making this possible!

Komentáře • 24

  • @carwashslayer4235
    @carwashslayer4235 Před 5 měsíci +2

    This elevator is great and I love this demonstration.

  • @AlexElevatorFan
    @AlexElevatorFan Před 5 měsíci +3

    I am glad you got permission to do fire service.

    • @BusMaster99
      @BusMaster99  Před 5 měsíci +1

      I'm glad I finally got to do it. It's something I've always wanted to do.

    • @AlexElevatorFan
      @AlexElevatorFan Před 5 měsíci +2

      @@BusMaster99 That's awesome

  • @JordanLoweElevaToursCanada
    @JordanLoweElevaToursCanada Před 5 měsíci +4

    Proud to say I'm first to the comments even though no one else on the Internet cares! 😂

  • @Lsxtransam83
    @Lsxtransam83 Před 5 měsíci +1

    Hold function should be tested, While in the hold position. The doors should not close or accept any floor call. This is very important to test. If that does not function correctly someone could take the elevator, leaving the fireman behind.

    • @BusMaster99
      @BusMaster99  Před 5 měsíci

      I did put it in hold during the demo, but I will remember to make sure the buttons are disabled if I get a chance to do this again.

  • @CenTexElevators489
    @CenTexElevators489 Před 3 měsíci +1

    Now that is really interesting how the fan shuts off when the Phase-2 operation is turned on.

    • @BusMaster99
      @BusMaster99  Před 3 měsíci

      Yeah I agree, especially since there's no way to turn off the lights and fan since there aren't switches for them in a 3300.

    • @CenTexElevators489
      @CenTexElevators489 Před 2 měsíci +1

      @@BusMaster99 That's one thing I don't like about the newer Schindler fixtures. They're too sterile, prone to breakage (glass panels and very expensive parts), and the limited option for controls such as lights, fans, and independent service.

    • @BusMaster99
      @BusMaster99  Před 2 měsíci

      @@CenTexElevators489 Indeed. It's why I prefer Kone.

    • @CenTexElevators489
      @CenTexElevators489 Před měsícem +1

      @@BusMaster99 Along with Otis, ThyssenKrupp-TK, and the local independent companies.

  • @elevatorfan7568
    @elevatorfan7568 Před 5 měsíci +1

    Great demo! Always wanted to see this on a 3300.

    • @BusMaster99
      @BusMaster99  Před 5 měsíci

      Same here. Glad I could be the first to do it. Thanks for the kind words!

  • @carwashslayer4235
    @carwashslayer4235 Před 5 měsíci +2

    When its flashing it means a smoke detector in the hoistway has activated and a Shut trip would ensue. Rendering the elevator useless.

    • @BusMaster99
      @BusMaster99  Před 5 měsíci +1

      Correct, even in fire service. If this happens, you would switch the emergency stop switch from RUN to STOP and evacuate the elevator.

    • @carwashslayer4235
      @carwashslayer4235 Před 5 měsíci +2

      Good to know@@BusMaster99

    • @Lsxtransam83
      @Lsxtransam83 Před 5 měsíci +1

      Incorrect, when the fire hat flashes, it’s because a smoke detector in the hoistway, pit, machine room, or machinery space has activated. It also does not mean it will shunt trip. Yes it is possible, but shunt trip should only be possible if those areas are sprinkled.

    • @BusMaster99
      @BusMaster99  Před 5 měsíci

      @@Lsxtransam83 The Schindler 3300 has no machine room.

    • @Lsxtransam83
      @Lsxtransam83 Před 5 měsíci

      @@BusMaster99correct, I was referring to the elevator code. Not specific to that model. Also why I mentioned the shunt trip is only in sprinkled areas, not specific to that elevator. Because I don’t know if that shaft is sprinkled.

  • @elevatoralarmcoasterandarc1214

    6:52: If you do, the normal elevator restoration won't work!

  • @AlexElevatorFan
    @AlexElevatorFan Před 5 měsíci

    Also what kind of key does it take?