![Rookie Refrigeration](/img/default-banner.jpg)
- 119
- 1 485 091
Rookie Refrigeration
United States
Registrace 21. 05. 2018
Rookie in the refrigeration world. Have done residential and commercial HVAC but always wanted to do commercial refrigeration. June25th marked my complete first year doing Commercial Refrigeration. I have since moved on to doing Rack Refrigeration at a great company. I’ll post new videos as they come about. Thank you all for watching this channel and I’ll be uploading more often.
Video
Refrigeration Unit down, multiple offender!
zhlédnutí 9KPřed 2 lety
Refrigeration Unit down, multiple offender!
Refrigeration Service Call: The Video I Could NOT upload before. Bad Supermarket.
zhlédnutí 6KPřed 3 lety
Refrigeration Service Call: The Video I Could NOT upload before. Bad Supermarket.
HVAC Techs: Let's Talk 2 weeks notice and job loyalty!!
zhlédnutí 7KPřed 3 lety
HVAC Techs: Let's Talk 2 weeks notice and job loyalty!!
HVAC: Pre Summer Service calls, RTU down.
zhlédnutí 3,8KPřed 3 lety
HVAC: Pre Summer Service calls, RTU down.
Rack Refrigeration: Case too cold and Subcooler not Working.
zhlédnutí 13KPřed 3 lety
Rack Refrigeration: Case too cold and Subcooler not Working.
Refrigeration: RACK with Load Issues with Brett Wetzel
zhlédnutí 14KPřed 3 lety
Refrigeration: RACK with Load Issues with Brett Wetzel
Refrigeration: Electrical troubleshooting on a new WALK IN BOX. WIC.
zhlédnutí 13KPřed 3 lety
Refrigeration: Electrical troubleshooting on a new WALK IN BOX. WIC.
Refrigerator: Walk in Freezer with Defrost issues.
zhlédnutí 17KPřed 3 lety
Refrigerator: Walk in Freezer with Defrost issues.
Refrigeration Service Call on Christmas Eve. Walk in Freezer Warm
zhlédnutí 17KPřed 3 lety
Refrigeration Service Call on Christmas Eve. Walk in Freezer Warm
BACK In The Rack Refrigeration World!!! Solenoid valve piped backwards!!
zhlédnutí 10KPřed 3 lety
BACK In The Rack Refrigeration World!!! Solenoid valve piped backwards!!
REFRIGERATION: Failed attempt at an Aluminum Micro Channel repair. My FAULT, on a Walk In Freezer.
zhlédnutí 12KPřed 3 lety
REFRIGERATION: Failed attempt at an Aluminum Micro Channel repair. My FAULT, on a Walk In Freezer.
HVAC: LG MULTI V INVERTER S startup. My first time working on VRF systems.
zhlédnutí 46KPřed 3 lety
HVAC: LG MULTI V INVERTER S startup. My first time working on VRF systems.
HVAC REFRIGERATION: My last Supermarket Refrigeration ONCALL Weekend
zhlédnutí 16KPřed 3 lety
HVAC REFRIGERATION: My last Supermarket Refrigeration ONCALL Weekend
HVAC: Reheat coil replacement on Dehumidification RTU DHU
zhlédnutí 12KPřed 3 lety
HVAC: Reheat coil replacement on Dehumidification RTU DHU
HVAC Refrigeration: Meat Case Running warm, High head pressure trip
zhlédnutí 11KPřed 4 lety
HVAC Refrigeration: Meat Case Running warm, High head pressure trip
Rack Refrigeration: Refrigerant Leak Alarm Late Night Service Call
zhlédnutí 12KPřed 4 lety
Rack Refrigeration: Refrigerant Leak Alarm Late Night Service Call
Self Contained Produce Case running warm And Using the Appion PT Wireless Gauges
zhlédnutí 8KPřed 4 lety
Self Contained Produce Case running warm And Using the Appion PT Wireless Gauges
Refrigeration Olive Cart Running warm. Self contained Unit.
zhlédnutí 6KPřed 4 lety
Refrigeration Olive Cart Running warm. Self contained Unit.
Rack Refrigeration: Rack Down, MULTIPLE OFFENDER!!!
zhlédnutí 9KPřed 4 lety
Rack Refrigeration: Rack Down, MULTIPLE OFFENDER!!!
HVAC : 4 RTUs Down. Newly Installed “York” systems
zhlédnutí 13KPřed 4 lety
HVAC : 4 RTUs Down. Newly Installed “York” systems
HVAC REFRIGERATION: Freezer is warm. Multiple offender system
zhlédnutí 13KPřed 4 lety
HVAC REFRIGERATION: Freezer is warm. Multiple offender system
HVAC Refrigeration: Walk In Freezer warm and I get kicked out of the store
zhlédnutí 28KPřed 4 lety
HVAC Refrigeration: Walk In Freezer warm and I get kicked out of the store
Rack Refrigeration: Dual Temp a Cases Running Warm, EPR Failure
zhlédnutí 7KPřed 4 lety
Rack Refrigeration: Dual Temp a Cases Running Warm, EPR Failure
HVAC REFRIGERATION: Why I Love the Bacharach H10Pro for refrigerant leaks
zhlédnutí 3,4KPřed 4 lety
HVAC REFRIGERATION: Why I Love the Bacharach H10Pro for refrigerant leaks
HVAC REFRIGERATION: Walk In Cooler at 46
zhlédnutí 15KPřed 4 lety
HVAC REFRIGERATION: Walk In Cooler at 46
HVAC Refrigeration: Do Leak Stop Additives Work???
zhlédnutí 44KPřed 4 lety
HVAC Refrigeration: Do Leak Stop Additives Work???
That shit is how I got electrocuted fuckin people putting wire nuts after the contactor
So how does one learn to the level brent is at, thats a smart mf.
2652 is the correct constant they teach us in school
Wow ,,,nice❤
Nice be video
You are dead to the right, when it comes to that loyalty crap. We have to better ourselves, that should be our first priority. These companies will ride you like a horse and hand out chicken feed.
Nice job trouble shooting. I've been enjoying your videos, thank you.
great stuff. you're a real pro
So if a compressor goes out, then that case goes out,or will the other compressors pick up the load?Thanks
What did he hold against the solenoid? 3:24
Looks like a murphy oil gas station 😅
Guys, some employee decided to re play a tick tok on an employee and waited for them to walk into the cooler. Then they threw the seasoning into the back of the evap. And........It blew everywhere.
I don’t know why people say it ruins compressors they don’t have proof must people don’t even know how compressors work
God bless you bro
I own two each yellow Fieldpiece bricks, a SC440 & a SC640. Not doing that again. Do you have any recommendations?
God bless you
Cuídate mucho de el calor y el alto voltage soldado
God bless you
God bless you all
God bless you bro
God bless you
Obviously, if you can't detect leak post repair, it must've been effective to stop the leak.
it is called false positive. h10pro in small setting is reacting to the slightest fart.
The units work with R-22 too?
Frankly, I hate that thing. 1. In the small mode it is making a lot of false positive signals, it was beeping at a candy wrap 2. It has 4 feet long tube from the sensor. Maybe I am the rookie, but I never could pinpoint the leak with h10pro, either one has to move it very slowly or give up 3 One has to constantly adjust those knobs. 4. It is huge. That is why I am happy that I have Testo 316-3. Easy, fast and reliable. I still cant understand why I keep h10pro :)
God bless you bro
God bless you bro
God bless you all
God bless you bro
I appreciate your approach. I can't tell you how many times I've butted heads with my boss who's a "veteran" refrigeration guy. No joke, he insists on going to the condensing unit first, will not enter the cooler. My approach is that I must first verify the fans are running, no ice on coil, thermostat calling, and solenoid is energized before going up top.
Wow your amazing ❤
So i have a issue, 8 can't find a leak on an ac unit 2.5 ton. I did a pump down and them pump niteogen into the systems 225 pounds of nitrogen it came down to 223 in an hr, used bubbles to check for leaks didn't see anything or hear anything it stopped at 223 psi. I also checked my gauge for leaks also and didn't see anything. I never used this, so my question is should i use it?
Damn bro, thanks for all your content! Went to HVACR trade school and honestly I didn’t learn shit there! I got transferred into refrigeration at the market and I’m struggling! These videos helping for sure! Keep them coming. More self contained troubleshooting please 🙏✝️
OMG. My Keens changed my life.
I like your videos brother
Where your been bro , miss the videos 👨🏽🔧
headmaster is only for cold weather, where are the units located?
Nice set up. My company doesn’t allow us to have a lot of parts.
Do I need heat trace on my walk in drain? It’s only about 1’ of piping before it goes outside. It has 3/4” insulation on it now.
What is that orange cord that is run near the drain? Is that heat trace?
I'd to thank you for the well explained procedures, for people that understand refrigeration is a great source of help when in doubt
Stopped watching the video when you started pointing fingers,I know how you feel but just leave that part out
Very informative sir..thank you
Probably because not using hearers
Thanks for the breaker break down super cool
Don't you have to thaw coil before you get pressures,cause pressures won't be right?
I generally let people go after a week even if they give 2 weeks notice, just because its been my experience that the employees dont give much care or quality on the last week of work. also, I like to catch them off guard just to help clean out the van and make sure they only take their tools and not my parts or tools
what are the steel cables on the top of the condensers
How did you know it was the fan delay and not the fan motors. Great video
Im a electrician (not a HVAC tech) am i having issues understanding how to hook up a couple new trenton condensor units. Is there a way i can contact you or you could contact me?