Vaccuum Pumps Compare 3 top brands 7,8,9 cfm field simulated test

Sdílet
Vložit

Komentáře • 43

  • @achdiagnostic7773
    @achdiagnostic7773 Před 6 lety +4

    I have the fieldpiece vacuum and I really like it. I used a yellow jacket 6 cfm for 25 years but never pulled a vacuum as fast as I have with the fieldpiece. I bought the vacuum rated hoses and core removal tool. 300 microns on a 2.5t system in about 4 minutes including the blue vac decay test. Love your shop set up. Never worked for anyone that provided me with gauges. Good vid.

  • @familywest1697
    @familywest1697 Před 6 lety +5

    Thanks for doing this Ted. I've been a bit starry eyed over the new Fieldpiece VP85. I think I'll go ahead and hang onto the ole JB a while longer.

  • @androslive
    @androslive Před 6 lety +3

    Nice comparison video.
    I personally went with the vp85 recently. It's worked very well. Im a fan of fieldpieces product support the few times I've needed them.

  • @justinlombard8676
    @justinlombard8676 Před 2 lety

    You take good care of your guys, giving them the best tools to get the job done!👍

  • @FrenchBeefCDN
    @FrenchBeefCDN Před 3 měsíci

    Love the fieldpiece but as a chiller mechanic with refrigerant monitoring in most rooms I work in, I NEED to be able to vent all gases out of the room into an exhaust and unfortunately the fieldpiece is not gas tight at the oil fill port and leaks fumes which almost set off the refrigerant alarm (which would have shut down the whole chiller plant at a pharma site.... VERY BAD.) Fantastic pump otherwise, love the oil change on the fly feature. Hope they revise this issue. My JB and YJ pumps are tight so long as you hook a garden hose to the exhaust port.

  • @aircooledtx
    @aircooledtx Před 6 lety +2

    Good quality test of vacuum pumps. I used JB pumps most of my career.

    • @jaydee2620
      @jaydee2620 Před 2 lety +1

      JB platinum is old reliable. Still have the eliminator from 15 years ago and my platinum from 12 years ago. Both work perfectly

  • @joestinson7195
    @joestinson7195 Před 6 lety

    good comparison video. back in the day i started with robinair,then jb, now i have a yj bullet

    • @cmuwarrior83
      @cmuwarrior83 Před 2 lety

      How good is the YJ Bullet working put for you? I'm thinking about purchasing one. Thanks

  • @mojoemurphy
    @mojoemurphy Před 5 lety +14

    Suprised you have all that equipment and still pull through a manifold

  • @bobo11112222
    @bobo11112222 Před 5 lety +1

    VR 85 how well did it held up months after this video???
    Do u recommend it?
    So far I leaning toward purchasing one for my self
    Found one vid who had some problems after 3 use

  • @erics9213
    @erics9213 Před 6 lety

    Nice demo. All of the pumps seem to be able to pull a final vacuum under 100. The YJ is a little cheaper than the other two.

  • @1hvacman113
    @1hvacman113 Před 6 lety +1

    Good job Ted. Noticed the hilmor gauges hanging there, I had a set of those a few years back and the supply house gave me a credit towards another brand due to a recall of the hilmor....might be worth asking about if those are bad. I loved the concept/design....just had issues with built in vac gauge.

    • @TedCookHVAC
      @TedCookHVAC  Před 6 lety +1

      1hvacman I had several sets and never once saw the microns display at all.

    • @1hvacman113
      @1hvacman113 Před 6 lety +1

      Anti DIY HVAC if those are the 4 port like mine were they have a built in micron gauge....they just had issues with them

  • @Eddy63
    @Eddy63 Před 6 lety

    Good Pump video Ted ... You can do a" Rig Rundown " on your Guitars , Amps , Pedals Etc ... Would be interesting ...

    • @TedCookHVAC
      @TedCookHVAC  Před 6 lety +1

      Lmao... Marshall... all knobs on 11.

    • @Eddy63
      @Eddy63 Před 6 lety

      Or higher with a set of Channel locks ... Lol

  • @trinito97
    @trinito97 Před 3 lety +1

    That bullet seems to be coming apart, I had only used jb’s I didn’t know how noisy other brands did.
    I like my jb’s compact and durable I have one that has lasted me 18 years

  • @Balticblue93
    @Balticblue93 Před rokem +1

    VP85 and VP87 with the Trublu hoses will walk all over those other pumps. It would have been below 500 microns in 3 minutes time single or double hose. one 1/2" hose and 3/8's work fast. Let the ballast stay open until it hits 2000 and then it will fly down to below 500. Pulling through the manifold is far too slow. I use the SM380V and use a CPS or Fieldpiece gauge on the liquid line with a 90 degree elbow to read micron level and run a decay test. The small hose and pulling through the manifold is what slowed the vacuum speed.

    • @murkyturkey5238
      @murkyturkey5238 Před rokem +1

      I don’t understand why people still use their manifold to pull vacuums 😂

    • @Balticblue93
      @Balticblue93 Před rokem

      @@murkyturkey5238 I totally agree and I try and talk other technicians out of running the vacuum through the 4-port. Some listen after they see how fast I can do it, even with a single hose. But they are paid hourly. I look at the faster I can move the more work I can get done.

  • @hangngoaigiare
    @hangngoaigiare Před 4 lety +2

    fielspiece? I dont know about all these equipment but I have to change their multi meter every year so bad. I change to Fluke last forever.

  • @TheWoodman064
    @TheWoodman064 Před 5 lety +3

    Fieldpiece seems to be be what I am drawn to but who knows! B.l.t.n!

  • @eddiesellers8522
    @eddiesellers8522 Před 6 lety +2

    how do you like the new fieldpiece vacuum pump?

  • @jcarney1987
    @jcarney1987 Před 3 lety +1

    The video is somewhat of a way to compare pumps, but I don't think its a good representation. Most pumps I see, you tell the difference when you get below 1000 or 500 microns and the strength of vacuum pulled really starts to show; but hey, we all have our opinions ;)

  • @donalddaniels5848
    @donalddaniels5848 Před 5 lety +1

    I wasn't paying attention what one won?

  • @scrambler350
    @scrambler350 Před 6 lety

    So many choices out there nowadays when it comes to vacuum pumps;
    does anyone know of a pump that has a built-in solenoid valve that opens and closes as the pump is turned on/off...?
    I'm tired of sucking vac oil into my big Appion hose.

    • @Tokaisho1
      @Tokaisho1 Před 6 lety

      That would be nice but I've always just manually cut off the pump with a valve

    • @throttlebottle5906
      @throttlebottle5906 Před 6 lety

      I did that once, but didn't notice and stop it at the hose, went right through the gauges and into the vehicles system (R134A) and they're picky about oil charge volume :(
      bad move, kicked self in arse then proceeded to tear it down and remove all the oil, it only cost me $200 more and half a day fiddling

    • @garybeardsley1219
      @garybeardsley1219 Před 6 lety

      Navac vacuum pumps say that they have automatic solenoid valves in them.

  • @vacuumboy6.0
    @vacuumboy6.0 Před 6 lety

    is 0 microns possible?

  • @kodieivie
    @kodieivie Před 2 lety +1

    Too bad the fieldpiece pumps won't last more then a few years

  • @abhinavgaur13
    @abhinavgaur13 Před 3 lety +1

    why "Anti DIY" ? :(

    • @mikepict9011
      @mikepict9011 Před 3 lety

      Hvac??? di die , di cry , di call up 1/2 way through a job with a material list and a helpers attitude....... which is definitely insulting

  • @dhinton8127
    @dhinton8127 Před 6 lety

    I always use my sman for microns when I pull a vacuum

  • @240sxrb26gt28
    @240sxrb26gt28 Před 4 lety +1

    Lol this video is so wrong in some many ways. Plus how do you not know who Jim Bergmann is!!!

    • @TedCookHVAC
      @TedCookHVAC  Před 4 lety +1

      240sxrb26gt28 I know who he is very well yes. So exactly what is it that you see wrong ? Have you seen the other parts of this video series? Do you even know what the point of this video is?

    • @jamminwrenches860
      @jamminwrenches860 Před 3 lety

      Ford! Chevy! Brand X is junk! Your doing it WRONG!!!!!
      Personal experiences can vary. Just because someone does things a little different does not mean they are wrong. His setup is perfect for the purpose and I'm sure he is very competent with his equipment.
      Chill out.

    • @AG-tg9in
      @AG-tg9in Před 3 lety

      Comparing pumps might as well do it right & forget those charging hoses. Yet seeing this tends to give others the reason to do it this way yet why people might misunderstand the way to evacuate. But I do see what your doing though.

    • @user-jh1mq2ih2u
      @user-jh1mq2ih2u Před 3 lety

      How is it wrong state your facts on what’s wrong