How to install an F and E cistern in a central heating system.

Sdílet
Vložit
  • čas přidán 26. 07. 2024
  • Derek looks at the dying art of the installation of an F and E central heating cistern.

Komentáře • 53

  • @markcliff9923
    @markcliff9923 Před 10 měsíci +3

    Well done Derek, lost count of the amount of Galvanised steel tanks I installed drilling the fitting holes with a brace and a tank cutter, then mauling them into position and piping them up 😄😄

  • @tirvplumbing
    @tirvplumbing Před 10 měsíci +2

    Well explained Derek. You're right it's a dying art, most jobs on these are just maintenance nowadays. Cylinders are making a comeback but all sealed systems now.

  • @pallsmortion4750
    @pallsmortion4750 Před 10 měsíci +1

    Great video, on a lot of early 2000s newbuilds we had to fit a combined vent and feed pipe on f & e systems, i never thought it was as good but it was what the spec allowed

    • @ef7480
      @ef7480 Před 10 měsíci

      Yep remembered that one - cold feed teed into the vent at the side of the cistern....usually off a 'Aerjec'.

  • @Skeletoncrew46and2
    @Skeletoncrew46and2 Před 8 měsíci

    Looking forward to this series

  • @michaeltrimmer8899
    @michaeltrimmer8899 Před 2 měsíci

    The chances of a vented cylinder coil springing a leak are extremely rare, i have only known of one in 55 years of plumbing, they are made of copper after all, good video mind

  • @bentzionroyde4786
    @bentzionroyde4786 Před 10 měsíci

    Thanks Derek great video 👍

  • @michaelmurphy8826
    @michaelmurphy8826 Před 10 měsíci

    Good info. knolage is power. Last time we fitted any tanks in a roof space At least 15 years ago

  • @farhanbutt5947
    @farhanbutt5947 Před 7 měsíci

    Derek 👍👍

  • @chohanchohan8208
    @chohanchohan8208 Před 10 měsíci

    Yes this is true…industry is being dumbed down….excellent video one again

  • @oneloveonelifeman
    @oneloveonelifeman Před 10 měsíci

    My father inlaw had a service valve on the f n E tank. Found it when he complained about not being able to bleed his radiators! Had to wet and dry the tank with all the crap that was in the bottom and remove it

  • @robertmailer4978
    @robertmailer4978 Před 10 měsíci

    Hi Derek very good, think you should do a follow up video, showing vent and feed pipe connections into central heating system, I always like the airater (4 pipe connection), still prefer open vent to a sealed system , heat only boiler are so much more reliable, the amount of call outs for low pressure is stupid 😢, also thermostat with battery!!, and smart thermostat, talk about going backwards!, keep it simple , as away great video,

    • @tomkatgastraining
      @tomkatgastraining  Před 10 měsíci

      That’s the next one mate 👍🏻

    • @robertmailer4978
      @robertmailer4978 Před 10 měsíci +1

      Hi Derek just a quick rant, when I started out there were no national repair company’s, you fitted a system with a old style heat only boiler that just worked( still have boilers I look after 30years old!, only had to change ,could not get replacement flue) in that time your probably go through 3 combe!, do loads of call outs for national repair company and I really question are most boiler fit for purposes , even the so call top brands are not that great, nearly every call out is a combe, pressure or over complicated control, think I better retire 🤣🤣🤣, ends up most customer have a service plan they really can’t afford or never us to have, we have gone backwards

  • @andrewmillwardwatford9410
    @andrewmillwardwatford9410 Před 10 měsíci

    Some manufactures allowed cold feed isolation valves and combined feed and vent as long as the boiler had an over heat sensor.

    • @tomkatgastraining
      @tomkatgastraining  Před 10 měsíci +2

      You are correct but why would you 👍🏻

    • @andrewmillwardwatford9410
      @andrewmillwardwatford9410 Před 10 měsíci

      @@tomkatgastraining because it makes cleaning a blocked cold feed easy by providing a compression join close to the point of blockage. Because it makes locking up easy with a 22mm speedfit stop end. Generally it just makes all the work needed more simple. Most of these systems have Mark and dirt in the expansion tank this needs to be cleared before we drained down so it doesn't end to the heating system. With an isolation valve we don't need to drain the tank or move the Mac into the system. Although some of it gets stirred up and moved into the system when we refill. In the 1990s I was doing callouts for Watford Council. We had 30 mins to fix any breakdown. An isolation valve in the cold feed make this very possible. So I think many reasons to fit an isolation valve in the cold feed when the boiler has an overheat stat. However your comments about the lack of skills in our industry are exactly correct and to encourage unskilled engineers not to fit these valves in case the boiler has no overheat stat. Properties with this type of system often still have old and out of date appliances. If we say safety first then this could be seen as poor practice. We really need some tighter controls on the quality and training what engineers in our industry. The work that you do here on CZcams is fantastic and contributes greatly towards engineers knowledge. I like to think that I contribute to this also with my own CZcams channel but there's such a big hole the review CZcamsrs can't fill.

    • @grimawormtongue2014
      @grimawormtongue2014 Před 5 měsíci

      ​@@tomkatgastraining to confirm, you can put isolations on the water tank that feeds the hot water cylinder below but not on the CH tank?

    • @tomkatgastraining
      @tomkatgastraining  Před 5 měsíci

      @@grimawormtongue2014 correct 👍🏻

    • @grimawormtongue2014
      @grimawormtongue2014 Před 5 měsíci

      ​@@tomkatgastraining
      thank you for the super quick reply. I'll be working on a f and e system today. All the hot water taps have severely restricted flow due to a blockage somewhere. I'll be cleaning out the tank and maybe I will need to cut out and replace some pipework on the hot water supply from the cylinder. Any tips please about how to drain and or clean the tank and cylinder and pipework?
      What checks do i need to do to trace the blockage/s? And anything i need ti look out for before cleaning and cutting pipework?

  • @allsearpw3829
    @allsearpw3829 Před 10 měsíci

    Hi , thanks for the info , how things are laid out now , so if a boiler is changed ? a new header tank and all the vent pipe work has to be changed ? 🤔Never liked combi boilers . But I was a sparks .

    • @tomkatgastraining
      @tomkatgastraining  Před 10 měsíci

      Nope only if they are installed incorrectly or in poor condition.

  • @garydulson9018
    @garydulson9018 Před 10 měsíci

    No its coming back as a thing for soid fuel installations. Spent all my time in the 90s taking em out, now we've started putting em back lol

  • @michaelsheriff231
    @michaelsheriff231 Před 10 měsíci

    👍👍👍👍

  • @SuperWayneyb
    @SuperWayneyb Před 10 měsíci

    🤘😎🤘

  • @thebeardedwunderer1503
    @thebeardedwunderer1503 Před 10 měsíci

    My understanding is that you can fit a valve on the out let provided the appliance has thermal cut out? Is this not the case?

    • @tomkatgastraining
      @tomkatgastraining  Před 10 měsíci

      Went to a job once where a baby had been killed by an f and e being installed wrong. The water boiled and melted the cistern and the water came through the ceiling and killed the baby and yes the boiler had an high limit stat.

  • @jockster5525
    @jockster5525 Před 10 měsíci +2

    Good choice for a video, see some disasters out there...rads higher than the f and e tank lol ...❤

    • @TheDickPuller
      @TheDickPuller Před 10 měsíci

      What about the ‘Plant Pot’ Servowarm F&E tank😂😂👍👍👍

    • @ef7480
      @ef7480 Před 10 měsíci

      Lol yeah, Also 'blocked cold feed' causing same symptom with fresh engineers not having a clue why..happy days

  • @markrainford1219
    @markrainford1219 Před 8 měsíci

    Hmm, now I always fitted the feed an inch above bottom BECAUSE of debris entering the system.

  • @accesszero4803
    @accesszero4803 Před 10 měsíci

    I often fit a gate valves for service reasons and remove the wheel so tgey cant turn them

    • @tomkatgastraining
      @tomkatgastraining  Před 10 měsíci

      You could fit a lock shield valve but no need for servicing 👍🏻

  • @mgbroadsterJ
    @mgbroadsterJ Před 10 měsíci +1

    I would never fit a F&E tank on a new instalation .It would be a presurised system .

  • @nickcannon5592
    @nickcannon5592 Před 10 měsíci

    The good old days mate, copper pipe and benders, stabbing into lead or wiping a joint, inverting the cold feed on system entry.
    Skill no longer seen

    • @ef7480
      @ef7480 Před 10 měsíci

      still use copper and still use pipe benders. Just the systems that are changing- more efficient with skills required elsewhere.
      Too many Luddites in the trades......

  • @mgbroadsterJ
    @mgbroadsterJ Před 10 měsíci

    Why not explain the cold feed and vent configuration ? Its basicly a close coupled tee . hydraulic seperation .

  • @peterreid4567
    @peterreid4567 Před 10 měsíci +2

    Can’t understand why you would ever want to fit an f and e in. Total waste of time so simple to instal but they can pump over draw in air and get really really sludged ….and I see loads of fitters who don’t understand the set up anyway. Basic plumbing.

  • @accesszero4803
    @accesszero4803 Před 10 měsíci

    I seal 99% of heat only boiler systems i fit

  • @colin4685
    @colin4685 Před 10 měsíci +2

    Old technology

  • @cathyoshea3844
    @cathyoshea3844 Před 10 měsíci

    You were talking complete and utter nonsense regarding the installation of a F and E tank, to suggest not to fit a full bore isolation valve on a central heating is ridiculous I thought you were a skilled plumber obviously not.

    • @tomkatgastraining
      @tomkatgastraining  Před 10 měsíci +3

      You have just proven you know absolutely nothing about heating and regulations. Think you need to read the water regs and then say I am talking nonsense. Also it’s a cistern you ignoramus not a tank.

    • @michaelmurphy8826
      @michaelmurphy8826 Před 10 měsíci

      You obviosly not HETAS registered

    • @mgbroadsterJ
      @mgbroadsterJ Před 10 měsíci

      I think you will find he is more skilled than all of us .

    • @ef7480
      @ef7480 Před 10 měsíci

      You are talking absolute 'utter' ball hooks my friend. You don't place a valve on an open vented heating system cold feed. This will create a hazard- now get back to college and look at the physics of water levels and how this system works..

    • @ef7480
      @ef7480 Před 10 měsíci

      @@mgbroadsterJ - replace 'all of us' with 'you'

  • @TheDickPuller
    @TheDickPuller Před 10 měsíci

    Great video Del, I think you covered everything well. But, you missed out the installations with combined F&V Pipes & their connection to the F&E tank.