Why we use 4-20mA Signal instead of 0-20mA or 1-5V DC in Industrial Instrumentation in Hindi
Vložit
- čas přidán 6. 09. 2018
- Why we use 4-20mA instead of 0-20mA or 1-5V DC in Industrial Instrumentation in Hindi -
1. Why we using 4 to 20mA Signal Hindi Tutorial.
2. Why using 4to 20mA Signal in industry.
3. The Fundamentals of 4-20 mA Current Loops in hindi.
Really good explanation....I had never understood this 4-20mA principal even though we have been using it for so many years... You explained it in such a simple manner. Thanks to you...hope many will benefit from excellent teachers like you!
4-20 mA 0 psi show ok good
Excellent supperb
Directly dimag me ghus gaya
Thank you very much
Sr pls continue the Instrument mechanic class ..... It's amazing and very helpful to us. Sr pls up daily vdo bana dete toh instrument k upor toh aachha hoga.😀🙏🙏🙏 Waiting for your kind reply 🙏🙏🙏
Nicely explaind sir. You are too good as a tutor, hats off to you.
Bahut saral m bahut important baat bata die thanks sir
Fully clear this confusion.. thank for explain 🥰
Sir agar mere paas plc me voltage module he aur pressure transmitter he 4-20ma he to me bich me 250ohm ka resistance used karke counts le sakta hu m-amps ke module me please suggest
You gave a fantastic lecture.thanks.
One of the best video on youtube.
Tq sir, I gained some knowledge from your video.
Thank you so much sir.. it's very helpful for us.. such a great way.. u are explaining.. after watched this all doubts ( has) cleared.. 😊
Thanks a lot for the explanation it helped me a lot sir🙌🏻
Thank you sir ap bahut ache se batye hai
Why current is not dropping in parallel and so voltage Does? Plzz make a separate video on this.... Thanks. Video was very helpfull❤️❤️❤️
Bahut achha samjaya sir 👍
sir your vidio is good knowledg of industrial instrumentetion
Thank you ...awesome explained
Very good presentation.....Thnaks
Very simply explained
Super sir . Excellent topic . 👏👏
Thank you sir
Very nice basic information.
thank you, sir, for explaining this concept
V.good working sir .
Please uplode a vedio on control loop . Feed 4rd 'feed backward' cascade and split range
Very nicely explained about pid controller system
You are great sir.....I want more larning from you....
Sir pressure measurement ke bare me v details dijiyega
Very nice way to teach us..
Sir muje a gaya smj me 👍
Sir aap kaha se padhe hain ..itna knowledge mujhe bhi chahiye sir... apka experience bahut a66i hai industry ko lekar... thank you so much sir
Well done, Great work thanks 😊 👍
What effect u had said in lecture at duration of time in video ( 7 minutes 21 seconds) ..
Excellent sirji
Nice information sir Thank you
Nice teaching sir
Undrstnd complete
Sir good explanation thanks
Sir, 3-15 ma kyo nahi use hota hai?
Very nice explanation sir...
Amazing explation ❤️
Very good experience sir ji
Very good sir,,👌👌👌👍👍👍👍👍
Sir, voltage drop ka standard & calculate kaise karte hain iss k uper ek video banaye...
So really nice
Knowledge video
How to use ABB HART with Siemens DPT
Thanks a lot for this information
In case of 0-20 ma, suppose if there is no flow through the pipe it indicates that 0ma,but when there is a open circuit it will also show 0 ma(here's the point where we will be confused) but when we use 4-20 ma when there is no flow through the pipe it indicates 4ma but when there is open circuit in the line it shows 0 ma...
So there is difference..
So which is better???
whenever signal indicates 0mA fault is consider
my question is why we use 4to20??
dusri koi range kyun nahi??kyun 5to25 nahi use kiyaa??why only 4to20???
Good sir.
Different between mv and ma
Wo samjaoo na sir
Or kab kb wo check krte he
Excellent sir
Sir esp ki panel to feild transformer tak charging process batyea plz
Thanks for information
Why to used 4 to 20 numbers Into instrument fields
Well explained ty 👍👍
Thank U sir explain krne keleye🙏🙏
Why we use 3 to 15 psi instrumentation
Why drive gives the 4-20 mA
💖 This is an inspiration for ME !! Even I make "INSTRUMENTATION VIDEOS".
I hope I can emulate your presentation skills.
All the best for your future videos ☺
Feild kya hota hai
Excellent
Very nice video !!!!!!
Very veryy good video
Sir pid se drive ka speed control ka video banaye
Sir 2-20 mA use Kyu ni krte
Lots of thanks sir
sir PLC s7 200 ke bare me vedio banaa kar samjhao
Very good explanation...thanks for your effort.
Thank you ji.
Thank you sir
Why only 4mA, why not 5mA or any other value
Best explane
why 4 why not 2 or 3 ?
Awesome sir
Nice video sir
Superb 👌👌
Lekin sir 4 to 20 mAmps hi kyu hm 8 to 24 mAmps bhi use kar sakte the pr 4 -20 mAmps hi kyu
Sir AP ki course attend kerna hai
Es ki fee and duration kya hai
Off line kab tak start kroge
Thank you bro
dear, we know about SSR.
Thanks ❤️
Nice video
24volt मे 4-20mA सिग्नल कैसे बनाए
Nice sir
Thank you
Sir its correct....but 2mA to 20 mA not used why sir
nice video
Sir,why used of transmittar in system please explain
Bro coz the field instrument will give you the signals in voltage.as u seen in the video voltage is not good for transmitting so a transmitter will convert it into current signals
Sir please microgrid ko detail me explain kijiye , iske types iske sare process full detail sr please sr please
thanks sir
Nice
why cannot we use 3 to 20 mA?
Thanks
Kiln ma 1200tam ko48ma manta hai Hume 25 sahu malting q karta hai 25 kasam nikal take hai
250ohm resistance ko kaise lagana hai plzz reply
khurram rehman series ma
Good
Sir plc ka kuch practically video bano 🙏
Thermocouple me mV use karte hai to uska voltage drop kyun nahi hota
Cold junction hot junction nikal chromium , nikal aluminum ki property agar pta hai to ye sawal nhi puchte
In industries we are using the 24volts power supply to the transmitter than how this theory will applicable? Because cards operates on 1v to 5v and the loop carrying mili amps to io cards is energised with 24volts....
I also have same question
Aapko koi nahi dega bhai reply, transmitter ki ps 24 hai lekin wo op 4 - 20 ma me dega
No register in transmitters
Great
4 MA hi kyon use karte hai
2 MA kyon nhi use karte
Please correct your explanation, at sensor & transmitter end voltage would never be 1-5V. It's the property of DCS/PLC I/O module to read/send all analog inputs/outputs at 1-5V at receiver end.
Open ckt detection
Long distance, no vol drop
Magnetisation effect