why 4 to 20 ma signal is used|| process instrumentation || industrial automation || plc
Vložit
- čas přidán 18. 12. 2021
- In this video, we will discuss why 4 to 20 ma signal is used in process instrumentation instead of 0 to 20 ma signal. Engineering study is a youtube channel to learn instrumentation engineering. this video is helpful for instrumentation interview questions and answers. the video is delivered in Hindi language. this video is helpful for instrument technicians and instrumentation and control engineers. video is helpful for field instrumentation and instrumentation training videos.
Facebook page
/ engineering.study.inst...
This is great channel for a detailed information to clear the basics of instrumentation and electronics
Thanks for your support and love 🙏
@@EngineeringStudy My pleasure
बेहतरीन होता ll दर्द सबके एक से हैं मगर हौसले सब के अलग-अलग है कोई हताश होकर बिखर जाता है तो कोई संघर्ष करके निखर जाता हैll""👇🏻💕💕💕💕❤️
Good
Excellent
Thanks
Very nice and informative video....keep it up
Thanks for your support and encouragement
thankyou sir
Thnk you brother for the video.
Welcome
excellent ❤️
Thanks
Thank you so much sir 🙏, kindly make a vedio for why use current signal used in the instrumentation,
czcams.com/video/XBERIJyb9Dk/video.html
Request provide video for complete SCADA with anolog & digital signals
Ok
👍👍👍
Thanks
👍👍👍👍
Thanks
Sir plz one question explain in Hindi
Control valve me class 4 and class 5 kiyaa hotaa h iska mtlb kiyaa plz immediately Just now video upload kre
Par 2to20mA bhi to use kar sakte hai, sir iska bhi answer bataiye
Nahi min3mA needed for transfer
Instrument resistance 250 ohm
Whe value is in °c how to slove it
1'5 use
Sir thermocouple ke milivolt ko voltage m kese convert karte h kon se formula se karte h
Aap hamare channel par rtd and thermocouple check video dekh lijiye
What Tc , Ti & Td in control valve .& How to set these values
Ok
Mannual me level transmiter ko adjust zero trim kaise karenge sir not used hart
Transmitter me zero & span krne ke liye screw hota he ush se kr de. So not use HART Communicator.
@@ravitechnicali.e7379 screw hota but usko open karne ke baad threee button hota ek button zero trim ke liyeee or dusra span karne ke liye usko adjust kaise karenge sir
For example tank me level hai 90% but transmitter me show kar raha hai 10% ye solution kaise hoga mannual calibration no use hart sir
6 to 24 kyun nahi lete sir answer bataye
Because plc dcs card is 1to 5 v working in 4to 20ma according so not use 2 to20ma jk
Thank you sir 🙏
@@jkbox299 wlcm.
4 to 20 ma ka jagah 10 to 50 ma bhi to rkha ja skata tha 4 to 20 ma kyun rakha gya ye batao
@@wakilraza1366 Using a standard multimeter we can detect failures or check the 4-20 mA loop easily. Besides there is no personal risk if we touch the wire because voltage is 24VDC and the dangerous current threshold for the heart is 30 mA.
@@vickygec87 yes bro i know just given the question 10 to 50 ma because 30ma up current to may be heart shock and another reason 4 t0 20 ma any transmitter electron start to need 3.5 ma so 4 ma given the stander value so 4 to 20 ma start