Commercial electrical fault finding

Sdílet
Vložit
  • čas přidán 17. 07. 2024
  • What's good guys, in todays video me and Callum have got some faults to find in this commercial electrical installation, and you also get the see the general day in the life of an electrician!
    T A D O F O R P R O F E S S I O N A L S
    www.tado.com/all-en/tado-for-...
    If you enjoy electrical content please subscribe to the channel and checkout my links below 👇
    M Y W E B S I T E ⚡
    residualcurrent.com/
    M Y L O A D O U T 🛠️
    residualcurrent.com/pages/loa...
    B I G B O O T S D I S C O U N T 🥾
    bigboots.co.uk/?ref=4s3760y77o - Use code RESIDUAL
    U N I L I T E D I S C O U N T 🔦
    unilite.co.uk/?ref=RESIDUAL - Use code RESIDUAL
    J O I N T H E C H A N N E L 🤝
    / @residualelectrical
    I N S T A G R A M 📷
    / residualcurrent
    T I K T O K ♪
    vm.tiktok.com/ZM86U2jjG/
    The works carried out in the video and the opinions shared are my own, and not representative of the associates and companies in the video.
    This content is purely for entertainment purposes and is in no way a "how to", tutorial or educational video.
    Please consult an electrician when dealing with any electrical installations.
    #electricianlife #electrical #electricalengineering
  • Věda a technologie

Komentáře • 85

  • @residualelectrical
    @residualelectrical  Před 6 měsíci +1

    Checkout Tado for professionals here: www.tado.com/all-en/tado-for-professionals? 🤝🏼

  • @carlgrooby9242
    @carlgrooby9242 Před 6 měsíci +21

    Tool is a bench grinder dressing tool(smooths down the face if been grinding in one place)

    • @eliotmansfield
      @eliotmansfield Před 6 měsíci +1

      yep

    • @tycobandit
      @tycobandit Před 6 měsíci

      It’s just your basic 4 1/2” grinder with a flap disc mounted. Looks like a Makita.

    • @Mark-mv2iu
      @Mark-mv2iu Před 5 měsíci

      I’ve looked at one at my work many a time and had no idea. Cheers

  • @x1BULLETfromABOVE1x
    @x1BULLETfromABOVE1x Před 6 měsíci +3

    Finally some good fault finding in an industrial setting, nice to see, really love these kinds of videos

  • @CommercialGasEngineerVideos
    @CommercialGasEngineerVideos Před 6 měsíci

    Glad that I stumbled onto this channel. It's what I've been looking for.

  • @neptunef5509
    @neptunef5509 Před 5 měsíci

    nice breakdown on finding the faults, well worth watching. continue on the uploads great content.

  • @benworthhington1518
    @benworthhington1518 Před 6 měsíci +2

    Always fun to watch fault finding videos. Got my qualification can't wait to work with someone who does this kind of stuff in the south west. Being an electrician feels like a fun job ⚡🔌

  • @MackLife87
    @MackLife87 Před 6 měsíci

    Hey, I enjoy this type of content, Im an industrial maintenance man, somewhat a rookie and love watching troubleshooting videos

  • @Spik3One
    @Spik3One Před 6 měsíci

    Good job. Thanks for video.

  • @ForTheBirbs
    @ForTheBirbs Před 5 měsíci

    An an aside I bought a Kewtech KT1780 yonks ago after seeing it on your channel. Best bang for buck ever in troubleshooting. Have used it to verify VDSL pairs in comms cabinets.

  • @itsKie.
    @itsKie. Před 6 měsíci

    Great video as usual mate.

  • @ForTheBirbs
    @ForTheBirbs Před 5 měsíci

    Saying of the day "why are you trying to look like you know what you're doing?".... lol. Go Callum! Love these fault finding videos.

  • @Daniellee-gs6ef
    @Daniellee-gs6ef Před 5 měsíci

    Great videos and content. I've been a domestic installer for 5 years now and it was the best decision I've ever made, work wise. I actually don't mind getting up to work but recently I've been getting a bit bored and want to challenge myself and take the next step. So seeing all the commercial work you do has made me really like to get involved. All the fault finding and installing content you do, I find so interesting. Keep it up

  • @ashvanbro9329
    @ashvanbro9329 Před 6 měsíci

    Another great video mate

  • @Ronny86_
    @Ronny86_ Před 6 měsíci

    Wish my days were as easy as yours lol. Just kidding mate I know our job swings in round about.
    Enjoyed the video and loved the little dinner date you two had ❤

  • @BT_____
    @BT_____ Před 6 měsíci +2

    Dorman smith are still kicking, 130 year strong. Pretty common in Scotland, good gear 👌🏻. Great vid as always mate 👊🏻

  •  Před 6 měsíci +2

    Ah yes Mikey welcome to the workshops 😂, that “torture tool” is for dressing the face of the bench grinding stone, different types of dressing tools for the different types of stone

  • @jamieo6642
    @jamieo6642 Před 6 měsíci +4

    Good find That 110v was dangerous,as one side of the split phase was connected to the earth. Any metal casing on equipment plugged in would have been 55v . Would have been interesting if you done a loop test on one of the 55v sides to earth, common problem with 110 distribution is the disconnection times are a lot lower than 230Uo. As a commercial & industrial electrician it amazes me the amount of non compliant 110v system I come across with zero testing and documentation

    • @gege12372
      @gege12372 Před 6 měsíci

      110v is normally wanged in by maintenance engineers, usually without electrical qualifications and always without experience...

  • @markvinter7522
    @markvinter7522 Před 6 měsíci

    Nice one, I also buz between phases, as burnouts and backfeeds can seem like 3 but only 2

  • @artmanning3565
    @artmanning3565 Před 6 měsíci

    Yes I had that before where one of the ballast have blown and took other lamppost out

  • @jasonmart1081
    @jasonmart1081 Před 6 měsíci

    Better lighting at last 😆👍 Make/buy yourself some industrial test sockets/adapters. Always check the reported fault before dismantling things, I've had a few where there hasn't been a fault. Why did that 119v socket have a screw terminal block? And it looked lke someone had linked the armours? (was each socket on it's own radial, or were they linked in to a bank)

  • @erikproductions9072
    @erikproductions9072 Před 6 měsíci +1

    As I've said before, your videos should be watched in a cinema.

  • @almerdiahmed3160
    @almerdiahmed3160 Před 6 měsíci

    Thank you 😊

  • @Josh__Stevens
    @Josh__Stevens Před 6 měsíci +1

    Everytime i hear that torque wrench in the the intro I can’t help but just think, Semtex 😂

  • @raynulife3569
    @raynulife3569 Před 6 měsíci +1

    The tool is for dressing grinding wheels. From and old sparky.

  • @dukeycarrow
    @dukeycarrow Před 6 měsíci +1

    Glad I got that bell on ⚡️

    • @residualelectrical
      @residualelectrical  Před 6 měsíci

      I appreciate that more than you'll ever know!

    • @shifty277
      @shifty277 Před 6 měsíci

      Likewise the productions and editing is different gravy as well as the subject of his work!

  • @GothGuy885
    @GothGuy885 Před 3 měsíci

    up until now I didn't know that 110 was used in England.
    as you might know, our wiring color code is different here in the US.
    Black is Hot , White Neutral, and green or bare copper for ground.
    and we run on 110 at 60 Hz with a 100/200 amp lead in for residential.
    we also have 230 but it is used mostly for electric stoves/ranges ,clothes
    dryers and Central Air Con. welders, and some air compressors.
    where your color code is brown for Hot, Blue Neutral and green with
    a yellow tracer for earthen ground. and you run on 230/50 Hz. Residential.
    LOL when you were working on the outdoor lighting, I flashed back to Mr Bean
    when he was waiting for a bus and a man at the stop has a heart attack, and
    Mr Bean runs and borrows a set of jumper cables, and opens up the lamp post
    and connects one end onto the power leads and uses the other and gives him
    a electric shock to start the mans heart again. 🤣

  • @pnxelectrical
    @pnxelectrical Před 6 měsíci

    Getting a very 'Brokeback Mountain" vibe, seriously should have an innuendo bingo card as part of the video 😂

  • @anthonybragg
    @anthonybragg Před 6 měsíci +2

    Something different Mike. I wouldn't put it down It's called experience and being a good sparks that's why you found it easy.

  • @clivequinn8978
    @clivequinn8978 Před 6 měsíci

    A Huntington type grinding wheel dresser. Cheaper than a diamond dresser.

  • @fromthetoon1602
    @fromthetoon1602 Před 6 měsíci

    For turbines its GWO courses you get them in a package roughly £1250 for all then you need a medical and chester step test

  • @jessieb1852
    @jessieb1852 Před 6 měsíci

    Get this man to 100K

  • @samfish6938
    @samfish6938 Před měsícem

    take off isolatator first ,uk electricians seem to take off outlets first go for easy 110 socket test it first before removig socket

  • @pnxelectrical
    @pnxelectrical Před 6 měsíci

    Windmills; first thing I think is GWO certification at minimum as thier working at height stuff is off the chain.

  • @hackwoodelectrical
    @hackwoodelectrical Před 6 měsíci

    Hmm cranes and faults… faulty towers? Ok I’ll see myself out 😂

  • @goose4342
    @goose4342 Před 6 měsíci

    What meter was he using?

  • @ColinDH12345
    @ColinDH12345 Před 6 měsíci

    Strange that where the lamps failed there were 2 LED units that had both failed in two instances?

  • @pnxelectrical
    @pnxelectrical Před 6 měsíci

    "This is rough content man, hooing the outside is more interesting, we're scraping the bottom of the barrel man"
    I didn't see any ISITEE being done 😂

  • @cliveramsbotty6077
    @cliveramsbotty6077 Před 6 měsíci

    how do they run the 60hz american stuff on the air base? just it do just fine at 50hz? cheers

  • @HarryTheSparks
    @HarryTheSparks Před 6 měsíci +2

    mike aren't you meant to cook them garlic mushrooms 😂😂😂

    • @residualelectrical
      @residualelectrical  Před 6 měsíci +1

      Now you mention it, you probably are 😂

    • @HarryTheSparks
      @HarryTheSparks Před 6 měsíci

      😂😂😂@@residualelectrical

    • @davidnull5590
      @davidnull5590 Před 6 měsíci

      Garlic mushrooms are usually crispy on the outside, those weren't.

  • @JC-jv5xw
    @JC-jv5xw Před 6 měsíci

    Now all the appliances with specially mis-wired 110V plugs will not work in that socket any more..........

  • @gege12372
    @gege12372 Před 6 měsíci

    Maintenance is hard to film, employers at the factory level want you working not filming! Lots of headache with H&S/Site policies regarding use of phones etc.

  • @user-un1oz6tc5q
    @user-un1oz6tc5q Před 5 měsíci

    iT'S A DRESSER FOR THE OFF-HAND GRINDER BELOW YOU.

  • @charliechan22
    @charliechan22 Před 6 měsíci +2

    GWO training, every 2 years for the wind turbines.

    • @residualelectrical
      @residualelectrical  Před 6 měsíci +2

      Thanks! 🤓

    • @charliechan22
      @charliechan22 Před 6 měsíci +1

      That's my plan once I get qualified. I was a rope access technician for 10 years. Get my gold card, and get my GWO and go have fun at height with electricity.

    • @residualelectrical
      @residualelectrical  Před 6 měsíci +2

      Keep me posted, sounds like a lot of fun!

  • @gino2465
    @gino2465 Před 6 měsíci

    Did you lock off that 110 circuit

    • @residualelectrical
      @residualelectrical  Před 6 měsíci

      Nope, but me and Callum where the only people in the building except our escort, and the board was in clear sight from where we was working.
      If I had even the slightest worry of any potential re-energisation it would be locked off 👍🏼

    • @gino2465
      @gino2465 Před 6 měsíci

      @residualcurrent you can tell I am a newbie just finished my nvq and am2.

    • @residualelectrical
      @residualelectrical  Před 6 měsíci

      Not at all buddy that’s the only attitude to have, I should have locked it off, and I normally always do, I’m just justifying my complacency 🤦🏼‍♂️

    • @gino2465
      @gino2465 Před 6 měsíci +1

      @@residualelectrical lol real world I know

  • @klarnorbert
    @klarnorbert Před 6 měsíci

    You didn't even need to unscrew at the first and second one. Could've just used your meter and check if there's voltage present. And at the lamp posts, you really just put in new fuses, instead of finding the fault?

  • @tinkrizmanic2747
    @tinkrizmanic2747 Před 6 měsíci

    that kewtech tester behaving a bit sus

  • @michealplater9007
    @michealplater9007 Před 6 měsíci

    No power or grinder don't work, get your voltage meter out.

  • @malcolmcroll7556
    @malcolmcroll7556 Před 6 měsíci

    how could a electrician wire this up -or was it a worker in the workshop ;?????

    • @residualelectrical
      @residualelectrical  Před 6 měsíci

      I don’t know 😂 it was proper installation, a lot of these are historic faults they waited for them to stack up before calling us in I think 👍🏼

  • @NickP1707
    @NickP1707 Před 6 měsíci +1

    With the 110v socket there’s no neutral. It’s two 55v lines.

    • @residualelectrical
      @residualelectrical  Před 6 měsíci +1

      Sure, I corrected myself half way through 👍🏼

    • @NickP1707
      @NickP1707 Před 6 měsíci

      @@residualelectrical I’ve just seen that as I’ve carried on watching 👍🏻 like the content mate

    • @davidnull5590
      @davidnull5590 Před 6 měsíci +1

      "It’s two 55v lines." What? I've never seen anything like that.
      I'm in the U.S., here the national standard for residential,
      120v/240v Split-phase - most people mistakenly call it single-phase (there's no single-phase in US residential).
      Almost everyone in the US calls it single-phase instead of split-phase - even sparks - otherwise no one knows what you're talking about. Commercial is too complicated to quickly explain here, commercial has split-phase, single-phase and three phase.
      At the incoming panel L1-N-L2 from the electric company. Local earth/ground provided ground rod(s), water pipe bond, etc.. Earth and neutral are connected at the incoming panel, only there.
      L1 to N 120v
      L2 to N 120v
      L1 to L2 240v
      US outlets any L to N, and usually an earth on outlets in the last 50 years.
      Plugs for US style 2 blades, some are polarized,, many aren't polarized. 15amp or 20 amp
      Plugs for US style 2 blades plus a ground pin at bottom. polarized. 15 amp or 20 amp.
      Imported Chinese crap often doesn't connect the earth to anything.
      240v sockets/plugs vary. electric range, clothes dryer, big-ass AC units.
      240v outlets other than those are very uncommon in a residence. You're not going to find them.
      In the US you can buy any variety of plugs.sockets you want, no one cares, I'm very surprised anyone in the UK had to ask permission to buy North American sockets (BTW: Canada also uses 120v.240v for residential).
      The asking permission part generally isn't part of life in the US in most areas of life.
      Any questions?
      Oh, in the US in urban areas often sparks are native Spanish speakers, it's common to find one who only speaks Spanish and a dozen English words - this isn't a problem here, just different.

    • @NickP1707
      @NickP1707 Před 6 měsíci +1

      @@davidnull5590
      Interesting read. So here in the Uk. Our standard supply is single phase to a domestic property
      L1-N 240v
      Or
      3 phase
      L1-L2 400v
      L1-L4 400v
      L2-L3 400v
      Some places it’s still on the old 415v like on the site I work.
      when it comes to 110v we use a transformer within the property/building which usually then feeds its own 110v board and the outlets are yellow
      If you test between
      L1-E 55v
      L2-E 55v
      L1-L2 110v
      I’m not the best at explaining things well but that’s the gist of it, it’s quite different between our counties.

  • @nunoochoa2475
    @nunoochoa2475 Před měsícem

    You will need GWO training to be able to work on wind turbine but if you would like to climb one i think its possible to go like a guest with supervision of a training technician. czcams.com/video/x6-WDNLXrvo/video.htmlsi=4GXvJkzpP-KEu-CJ

  • @danielmihai5
    @danielmihai5 Před 6 měsíci

    OMG! Working with metal hand-watch inside a live panel. Really!
    Is not a good ideea even you have good skills. Soon or later something wrong could be happend.

  • @fuckjewtube69
    @fuckjewtube69 Před 5 měsíci

    They must have though green was on and red was off on the breaker

  • @davoc5140
    @davoc5140 Před 4 měsíci

    great vid!
    Im a new electrician . .. can you comment on uc and ul? I did my first rcd test and my tester said uc greater than ul! cant see how to fix ..any suggestions?