So Inputs ABC Can't Be Used To Be Controlling Inputs For Output 3 Or 4? Like You Couldn't Wire Up Temp Sensor And Have It Control Outputs 3 And 4 Thermostatically For A Trans Cooler, Oil Cooler Or Coolant Fans?
So The Green Wire Labeled Lambda Connectors To Your Widebands 5v Analog Output Signal? It Seems Obvious But Manual Doesn't Say Where It Connects And I Want To Make Sure.
So Inputs ABC Can't Be Used To Be Controlling Inputs For Output 3 Or 4? Like You Couldn't Wire Up Temp Sensor And Have It Control Outputs 3 And 4 Thermostatically For A Trans Cooler, Oil Cooler Or Coolant Fans?
Inputs A,B, and C are datalogging channels only. They will not have any effect on any outputs.
I have my maximizer 5 setup for time based but it still pulses. Please advise on this issue. What hertz does it recommend setting at?
Time based ramps still pulse the solenoids, the hz depends on what solenoids you are using.
So The Green Wire Labeled Lambda Connectors To Your Widebands 5v Analog Output Signal? It Seems Obvious But Manual Doesn't Say Where It Connects And I Want To Make Sure.
Yes, that is correct.
Is there a video on how to use the touch screen? mine keeps saying error no output enabled on mine.
You need to go into the max 5 and enable an output by clicking a check box.
Does the max 5 offer the same time delay as the max EZ?
Thanks!
You can adjust it in the same way, yes.
@@NitrousExpressVids thats a good unit
How do I wire it so it's not spraying on 2 step
Wire input #2 to see 12v+ when the two step is activated, then set input #2 in the software to "Disarm this Output"