Plumbing Base Inspection

Sdílet
Vložit
  • čas přidán 5. 09. 2024
  • Here's a crash course on plumbing base inspections in the Pikes Peak region. In this video we go over what our inspectors are looking for and the common mistakes they run into out in the field.

Komentáře • 111

  • @je-niseghana7377
    @je-niseghana7377 Před 6 měsíci +1

    This is by far one of the best plumbing inspection videos i have everwatched. thanks for making this

    • @PPRBD
      @PPRBD  Před 5 měsíci +2

      Thank you for the feedback. We hope the video was helpful.

    • @je-niseghana7377
      @je-niseghana7377 Před 5 měsíci

      @@PPRBD very helpful

    • @billbell5495
      @billbell5495 Před 21 dnem

      Great job, I'm a old LA City plumbing inspector for the city of L.A. Great

  • @johnpeters9903
    @johnpeters9903 Před rokem +3

    Nice video, very Informative for the audience. I am retired after 49 years in the trade and never had an inspection that complete. The homeowner is definitely getting their money's worth.

    • @PPRBD
      @PPRBD  Před rokem

      Thanks for the feedback John. Enjoy that retirement.

  • @medmuscle
    @medmuscle Před 2 lety +11

    Awesome video. It was very informative. I really appreciate people taking the time to put informative videos on CZcams to help other people learn.
    I'm the only code enforcement officer in a small town. While we do have a couple of building inspectors and a building official in our department, the city is encouraging me to get into building code to help out. I decided to start with plumbing.
    I loved your presentation in this video. It was easy to understand. Excellent work!

  • @rustycarpenter1219
    @rustycarpenter1219 Před rokem +4

    Nice one, around here we do 10' of water head for testing pressure

    • @farrlaterry1365
      @farrlaterry1365 Před 2 měsíci

      Is that an UPC requirement?
      Are they allowed to use air tests for plastic pipe or I'm seeing something else?

  • @mark_Hershey
    @mark_Hershey Před 2 lety +11

    Wow, ky plumbing contractor here. I am amazed at the lack of vents some states have. We are required to vent EVERY fixture. Zero wet venting allowed. Just thinking how easy it is to plumb there.

    • @ImYourHucklebery117
      @ImYourHucklebery117 Před 2 lety +3

      Yep, the way he had the combo close with the ptrap with no vent in-between was kind of worrying

    • @winterfar2814
      @winterfar2814 Před rokem +2

      Wet venting and combination waste and vent is used all the time and works. A lot of people just don’t understand how to design it properly so they just add vents everywhere wasting time and money.

  • @quickthailesson1113
    @quickthailesson1113 Před 3 lety +25

    Music does not add to video. It only makes it harder to hear the voice.

    • @maestrovso
      @maestrovso Před 3 lety +2

      It is so ingrained that people think they have to add some cheesy soundtrack on any video, even with professional productions. For me silence is golden, and bad sound is noise. If they pay for a "audio designer" he just want to hijack the video thinking people are here to listen to his poor taste in music. And he likes to constantly mess with the sound mixing board as he is strung up with coke.

  • @tomdavis3495
    @tomdavis3495 Před 2 lety +5

    On the wet venting of the bathroom group, the toilet flushes by the tub and cuts off the wet vent from the lav. Red Tag! The tub should be caught on the 2" wet vent before the toilet. Plumbing 101.

    • @Robertz37
      @Robertz37 Před rokem

      3” pipe on a wet vent system can carry a total of 12 dfu’s so it is oversized and will accommodate for the venting. Although I can’t picture how the system will be vented from the lav when it has exceeded 8’ with a 1/4 “ fall. I see the vent rising above the horizontal plane of the wet vent system and with the lav going at the same time as the toilet or tub there would not be a vent or it would create siphonage. What are your thoughts?

    • @tomdavis3495
      @tomdavis3495 Před rokem

      @@Robertz37
      Basically, a toilet can't flush by another fixture without that downstream fixture (the tub in this case) being vented first by the lav wet vent (3:44). So, John the inspector was either taught wrong or he has been breathing that thin air up in Pikes Peak too long. ;))) Actually, I see this situation as acceptable in many western US videos, but here in the southeast that is a no-go situation. The hydraulic gradient situation you are referring to would refer to the fixture arm that is being vented off of the wet vent. In this case, it would only refer to the toilet arm and the tub arm, not the wet vent pipe from the lav.

    • @Robertz37
      @Robertz37 Před rokem

      @@tomdavis3495 What plumbing code are you under where you’re located?

    • @tomdavis3495
      @tomdavis3495 Před rokem

      @@Robertz37 Hi Robert We use the Florida Building Code which is based on the International Building Code. Due to our area receiving higher winds (hurricanes) than many places across the country, the Florida Building codes are much stricter in the structural areas due to these wind issues.

    • @Robertz37
      @Robertz37 Před rokem

      @@tomdavis3495 Right on. Makes sense. Where I am at in Colorado we go by the International plumbing code. It seems more strict then the UPC code but from what you’re saying not as strict as Florida code which makes sense from the information you’ve given me. Thank you for your comments and insights. May you have a safe and prosperous journey in your plumbing career. Thanks for your time.

  • @dialac1
    @dialac1 Před rokem +1

    Thanks so much for this video. Answered my questions about venting

    • @PPRBD
      @PPRBD  Před rokem

      Excellent. We're glad it was helpful.

  • @bp4170
    @bp4170 Před 3 lety +6

    Thank you for a clear explanation.

    • @PPRBD
      @PPRBD  Před 3 lety +3

      Hey Brian, thanks for the feedback. We hope the video was helpful

  • @TeslaBoy123
    @TeslaBoy123 Před 2 lety +2

    In state of Illinois all underground plumbing drains pipe size 4" minimum vents 2" are allowed

  • @Skateforlifelad
    @Skateforlifelad Před 6 měsíci

    First inspector I've ever seen place a level on any pipe.

  • @johne.meyerconstructionser7507

    you have read the code ref air vs when water available and dont need a 10head anymore but cities can require it. 5' head is minimum.
    they have way too much developed length between those pipes. the potable water had no air on it and was not above the sewer line enough. it was done the way we see all the time but not up to snuff. pvc doesnt have an issue with cement against it-by requiring a foam wrap on anything other then a toilet which isnt needed now either since you are allowed to use a 4x3 90 the flange will glue in and be tapconned down on second phase.you make a weep area for ground water and bugs your inspector did good except for foam and air on sanitary when water is better-code will allow air when water not possible. no air on main potable water main in. and it wasn't stepped above sanitary line. you get a like because he bent over and checked pitch and walked on main to see if it bowed anywhere-well done.

  • @lorenzohernandez4540
    @lorenzohernandez4540 Před rokem +1

    Thank you so much 😊

  • @rbspider
    @rbspider Před 2 lety +2

    I think they should have checked that the pipes were vertically plumb too . I bought a condo where the toilet flange was not even close to being plumb . Try putting in a tile floor and toilet , what a nightmare and you could clearly see that the lab at this site was way out , wonder how the other two pipes were?

    • @rustycarpenter1219
      @rustycarpenter1219 Před rokem

      They often aren't, usually end up tilted at 90 to the dvw stack which is on 1/8 bubble or 1/4 bubble

  • @df4480
    @df4480 Před 2 lety

    My brother just pass his master on plumbing. Better learn this stuff great video.

  • @stanalaka821
    @stanalaka821 Před 4 lety +1

    Respect for what you do

    • @PPRBD
      @PPRBD  Před 4 lety

      Thank you Stanley. Our plumbing team is awesome and they put a lot of hard work in. Our team normally does about 3,400 plumbing inspections each month.

    • @saltypipefitter4618
      @saltypipefitter4618 Před 3 lety

      How much does a plumbing inspection cost ? If you fail do you get a time frame to fix it ? Or pass fail then pay again ?

    • @PPRBD
      @PPRBD  Před 3 lety

      @@saltypipefitter4618 With the Pikes Peak Regional Building Department the cost of the inspection is factored into the permit. Once a permit is obtained you have 180 days to call in an inspection. If that inspection fails you have another 180 days to make corrections and request another inspection. If the project fails too many times and/or the inspector notes are being ignored, a triple fee could be applied and that must be paid before another inspection can be requested. Hope this helps.

  • @CarlosAntonio-im7uw
    @CarlosAntonio-im7uw Před 2 lety +2

    Lot of great information. Thank you. If I make one suggestion for your videos, either turn down the music and make it totally background or lose it. It is too loud in this video and it complete distraction and difficult for The Listener to follow along with the inspector

    • @PPRBD
      @PPRBD  Před 2 lety

      Hi Carlos. Glad the video was helpful. Thanks for the feedback on the music.

  • @TimBruce1
    @TimBruce1 Před 3 lety +1

    Great video. Very good presentation and descriptions.

    • @PPRBD
      @PPRBD  Před 3 lety

      Thanks Tim. We hope it was helpful.

  • @ImYourHucklebery117
    @ImYourHucklebery117 Před 2 lety

    1:45 you also want to check the schedule of the pipe, schedule 40 is better underground, you can see behing the orange glove the pipe marking in blue "Coex Cellular" this pipe is usually used aboveground

    • @PPRBD
      @PPRBD  Před 2 lety +1

      Hello Mr. Slayer. The code allows Coex cellular piping to be installed above or below ground. Hope this helps.

    • @tannerwest6823
      @tannerwest6823 Před rokem

      Here in NC we use the hell out of some foam core underground. Works just fine

  • @saraalcala1621
    @saraalcala1621 Před rokem

    Loved it! Thank you.

    • @PPRBD
      @PPRBD  Před rokem

      Thanks for watching. We hope the video was helpful.

  • @backwoods7678
    @backwoods7678 Před 2 lety +1

    Since when can the water supply be in same ditch or level as your sewer main ..that has always been a cross contamination issue .. I've worked many states to .. The 10 state's I've been in require. A foot above sewer and a foot beside .. Also some states use vacuum test and not air now .. I see many other questionable things that in m9st states will not pass.. This state would be cake walk .. Just was wandering that's all

  • @jamiboothe
    @jamiboothe Před 3 lety

    This was very very good to see.

    • @PPRBD
      @PPRBD  Před 3 lety +1

      Hope it helps Jami. Have a great day.

    • @jamiboothe
      @jamiboothe Před 3 lety

      @@PPRBD It was certainly helpful. I am a first time owner builder, and am currently negotiating the build process.

  • @keithrichards4513
    @keithrichards4513 Před 3 lety +1

    Thanks ,Very informative!

    • @PPRBD
      @PPRBD  Před 3 lety +1

      Thanks Keith. We hope it helps

    • @byronluca9041
      @byronluca9041 Před 3 lety

      pro tip: you can watch movies at flixzone. Me and my gf have been using them for watching loads of movies recently.

    • @ericjesse3753
      @ericjesse3753 Před 3 lety

      @Byron Luca yup, I've been using Flixzone} for years myself :)

  • @mswvette
    @mswvette Před rokem +1

    What are the circle things on the pipes for the floor drains called?

    • @PPRBD
      @PPRBD  Před rokem

      If we're talking about the same circle thing, I believe those are called Quad drains. Hope that helps.

  • @buck-johnson
    @buck-johnson Před 2 lety

    Great video.

  • @vincentchato519
    @vincentchato519 Před 3 lety

    Nice job. From a New Mexico JP

    • @PPRBD
      @PPRBD  Před 3 lety

      Glad we could help our neighbors to the south. Have a great day.

  • @jorgerobles4820
    @jorgerobles4820 Před 3 lety +2

    Have much is slope en 3 inch pipe? Thanks

    • @PPRBD
      @PPRBD  Před 3 lety +3

      Hello Jorge, minimum slope for 3” drain pipe is 1/8” slope per 1 ft. Hope this helps.

  • @AHoney-xl9ux
    @AHoney-xl9ux Před rokem

    Nice video but tell us, how much pressure require for testing drain pipes as per plumbing code.
    I think 25 PSI ? Please correct if I am wrong.

  • @Innovative_Drafting.Design
    @Innovative_Drafting.Design Před 4 měsíci +1

    in 2024 is it 1/4" per foot drain for 3" pipe or still 1/8" ?

    • @PPRBD
      @PPRBD  Před 4 měsíci

      The current 2021 IRC has not changed that requirement. 1/8’’ per foot for 3’’ is still ok

  • @sodapuffs
    @sodapuffs Před 3 lety

    excellent job

    • @PPRBD
      @PPRBD  Před 3 lety

      Thanks Allie. We hope the video was helpful

  • @manueldiazcu
    @manueldiazcu Před rokem

    2:20 two floor drains are not vented. Developed length more that 8 feet on two inch is a red tag 100%

    • @PPRBD
      @PPRBD  Před rokem

      Hi Manuel, thanks for watching the video. Both drains are vented and our inspector explains that at about the 2:26 mark.

  • @phrepster
    @phrepster Před 3 lety +1

    Basement bathtub trap needs 2 pipe sizes of pipe between itself and the next fitting?

    • @PPRBD
      @PPRBD  Před 3 lety +2

      Hello Jake, the tub trap needs 2 pipe sizes from the vent. Not necessarily the next fitting. Feel free to contract our Chief Plumbing Inspector Joel if you have any more questions. His email is joel@pprbd.org. Hope this helps.

  • @marcelaabrach734
    @marcelaabrach734 Před 2 lety

    I love this video! For the pressure test, where should we place the test plug? Does it need to be after the drain has exited the building? Thank you!

    • @PPRBD
      @PPRBD  Před 2 lety

      The plug or cap can be placed at the end of the pipe outside of the building or a test tee is installed immediately inside the building which will allow the plug to be installed in the test tee.
      Hope this helps.

  • @achristianson4059
    @achristianson4059 Před 2 lety

    Hey thanks john

  • @Nyck461
    @Nyck461 Před rokem

    What I am wanting to know is how the plumber start and how he takes measurements to dig the trenches and and run all the pipes to the designed locations in a land where nothing is yet built.
    How everything (bath, kitchen, laundry, etc) matches to the precise location after the house is built?

    • @Chuckysdad19
      @Chuckysdad19 Před rokem +1

      The plumber would have to use the architectural drawing and string line to lay out the relevant walls. The drawings should have measurements from the foundation to the walls. The exact location for fixtures is critical to avoid having to chip concrete and move the pipes later.

  • @Karim-lj5er
    @Karim-lj5er Před rokem

    Very useful

    • @PPRBD
      @PPRBD  Před rokem

      Thanks for the feedback. We hope the video helps.

  • @andrey162000
    @andrey162000 Před 11 měsíci

    That tub will syphon when flushing w.c

  • @MyFortressConstruction

    0:34 You could feel his soul getting sucked out as he explained what a failed 5 lbs test would would show, "There wouldn't be 5lbs on the gauge........sigh........."

  • @kevinhornbuckle
    @kevinhornbuckle Před rokem

    The music is distracting and too loud. Otherwise, vital info.

  • @a7med088
    @a7med088 Před 2 lety +1

    What is the benefit of the music in the background ???
    🤬😩🤯🤯🤯🤕

    • @vanmonroe4346
      @vanmonroe4346 Před 2 lety

      I thought the same thing ---- pointless ---- I want to learn something about plumbing, and cutesy upbeat generic music doesn't help.

  • @markbone5028
    @markbone5028 Před 3 lety

    Does an air test on PVC void the manufactures warranty? Air test on PVC are dangerous.

    • @TeslaBoy123
      @TeslaBoy123 Před 2 lety

      Water leak test or 5 pounds air are allowed

    • @dtm6215
      @dtm6215 Před 2 lety

      Been testing with air for decades . Who said it’s dangerous ?

    • @philweiand4564
      @philweiand4564 Před 2 lety

      3.5 psi max , you can explode pvc .

  • @brandong550
    @brandong550 Před 2 lety

    The background music is a bit much. Difficult to hear and focus.

  • @zonatimetraveler5019
    @zonatimetraveler5019 Před 2 lety +1

    Please, no background music. Or at least something very banal and low. Otherwise, informative!

  • @heyheyjaytube
    @heyheyjaytube Před 8 měsíci

    This guy sounds like me doing pretrip inspection in front of Dot tester

  • @henrythompsonIII
    @henrythompsonIII Před 2 lety

    Yes, the music is extremely distracting.

  • @HoosierGroyper
    @HoosierGroyper Před 2 lety

    Music is very irritating. Couldnt focus on what the inspector was saying.

  • @sakyiebenezer2941
    @sakyiebenezer2941 Před 2 lety

    Please am plumber in Ghana I need work in your place

  • @pauljohnson8154
    @pauljohnson8154 Před 3 lety +1

    Plumbing code requires 3" stack for a washer drain

    • @pauljohnson8154
      @pauljohnson8154 Před 2 lety

      @Supa Trending Daily only if the 2" branch runs to a 3" vertical stack. Has been code for a while read the code book.

    • @TeslaBoy123
      @TeslaBoy123 Před 2 lety +1

      3" toilet washer 2" vertical drain are approved in many states

  • @vivianvasquez6966
    @vivianvasquez6966 Před 2 lety

    good video but music I couldn't watch it

  • @tomverdi8030
    @tomverdi8030 Před 2 lety

    Your tub drain isn't vented

    • @PPRBD
      @PPRBD  Před 2 lety

      Hi Tom. As John explained in the video the tub is part of the wet vent system for the bathroom group. Hope this helps.

  • @landontucker6824
    @landontucker6824 Před rokem

    Wet vent fail

  • @martindekker8203
    @martindekker8203 Před 3 měsíci

    Why the music? get rid of it had to hear him.

  • @sssanitary8557
    @sssanitary8557 Před 2 lety

    Can you give me a pipe fitting job?

  • @buckfiden1228
    @buckfiden1228 Před 2 lety

    At 3:46 that bathroom group is not properly vented

  • @highway2run
    @highway2run Před 2 lety

    Turn the. Music off

  • @MarleneSargeant6846
    @MarleneSargeant6846 Před rokem

    Stop the music please!

  • @umbasa01
    @umbasa01 Před 3 lety +1

    Hard to hear over music. Weak hearing.

  • @GreenGrow-ck3pg
    @GreenGrow-ck3pg Před 2 měsíci

    I guess I'll make a video explaining everything unlike u

  • @EvgeniiIudin
    @EvgeniiIudin Před měsícem +1

    Thank you so much!

    • @PPRBD
      @PPRBD  Před měsícem

      No problem. We hope the video was helpful.