Introduction to GPC in 30 minutes

Sdílet
Vložit
  • čas přidán 20. 07. 2024
  • Presented by GPC applications specialist Dr. Kyle Williams this 30 minute introduction offers a comprehensive educational insight into the technology and its applications.
    For further information and more resources please register at www.malvern.com/en/profile/reg...
  • Věda a technologie

Komentáře • 39

  • @aliyahdalier4011
    @aliyahdalier4011 Před 3 lety +2

    Such a great video, it covered every aspect I needed to know!

  • @josuecremonezzi
    @josuecremonezzi Před 4 lety +2

    Very, vey didactic and useful! Thank you so much!

  • @Bubblecoffee
    @Bubblecoffee Před 5 lety +2

    Great video!
    How do they control the pore sizes in the particles that are inside the column? Are the different pore sizes controlled through polymerization?

    • @MalvernPanalytical
      @MalvernPanalytical  Před 5 lety +1

      Thanks very much for the positive feedback. To answer your question, the particle sizes and pore sizes are controlled through polymerization. For example, polystyrene divinylbenzene (PS-DVB) the pore size is controlled by copolymerization process (addition of divinylbenzene). Moreover, a catalyst may be used to increase polymerization rate. Much like crystallization the particle size and “tightness” of the particle (i.e. pore size) can be controlled by the rate.
      The MW and volume is usually a range that approximates a Gaussian distribution. Thus, afterwards, we need to characterize and cut the high end and low end of the distribution. This is a physical process. Also, the column solvent may swell or shrink the particles and pores and we adjust the manufacturing technique to account for this. The reported particle and pore size is usually an average. “

  • @aniawo5119
    @aniawo5119 Před 4 lety +1

    Thank you, great video. Need to watch it few times to remember all the details. 🙂

    • @MalvernPanalytical
      @MalvernPanalytical  Před 4 lety +1

      Thank you for your positive feedback. Contact us if you need more information - www.malvernpanalytical.com/en/about-us/contact-us/

    • @aniawo5119
      @aniawo5119 Před 4 lety +1

      @@MalvernPanalytical thank you. I have read your replies to other questions and I found them very helpful. You are truly the experts (and very kind people too).
      Thank y o u again.

    • @MalvernPanalytical
      @MalvernPanalytical  Před 4 lety +1

      You're welcome. are you aware of our blog as well? www.materials-talks.com/

    • @aniawo5119
      @aniawo5119 Před 4 lety

      @@MalvernPanalytical I haven't been aware but will definitely have a look. Thank you.

  • @rodrigogavazzoni
    @rodrigogavazzoni Před 3 lety +1

    video bala, ajudou mt

  • @sawitreesue-eng9858
    @sawitreesue-eng9858 Před 5 lety +2

    thank you so much, It's really useful for me^^

  • @gavinirvine2725
    @gavinirvine2725 Před 5 lety +1

    Very useful, thank you.

  • @ankansarkar9417
    @ankansarkar9417 Před 4 lety

    It's really insightful. I have just started to operate the GPC instrument. Can you make a video about how to operate this instrument?

    • @severinemichel7964
      @severinemichel7964 Před 3 lety

      Hello, I'll ask our specialists about this video idea. Thanks

    • @MalvernPanalytical
      @MalvernPanalytical  Před 3 lety

      Here is the reply from our specialist
      Thanks for sharing the compliment. There is a lot of information on how to operate the instrument available on our GPC/SEC Expert Advice playlist:
      czcams.com/play/PL2wIBTZfZRjd7tyhnBRy2xLhToO3CCcY9.html

  • @RajeevKumar-bs6qo
    @RajeevKumar-bs6qo Před 5 lety +2

    In gpc chromatogram there is a solvent peak always, why ? How can we explain it ? Because in HPLC there is no solvent peak.
    Thanks for this informative video....

    • @MalvernPanalytical
      @MalvernPanalytical  Před 5 lety +1

      The chromatograms obtained from GPC/SEC typically have a solvent peak in the refractive index detector’s response. This is because it’s a differential refractive index detector, and a comparison is made between the blank solvent in the reference cell and the solvent, and anything else present at the end of the chromatogram. The RI detector is very sensitive to slight differences between solutions, and the difference between the solvent in the dissolution solvent and mobile phase is usually enough to produce a response. Solvent peaks aren’t as strong in other detectors. UV detectors only see molecules with a UV active chromophore, which most solvents do not possess. The light scattering detector responds to a sample’s molecular weight, and since solvent molecules are all small, discrete molecules the differences aren’t detected. And a viscometer observes changes in solution viscosity, which isn’t usually that different between the mobile phase and the dissolution solvent.

      I think most HPLC systems use a UV detector, which is why there is usually not a solvent peak.

      There is a little more info on what creates solvent peaks near the end of this post.

      www.materials-talks.com/blog/2018/08/22/what-is-a-dndc-value-and-why-is-it-important-for-gpcsec/

  • @millikengpc6420
    @millikengpc6420 Před 2 lety

    I know you no longer make high temperature systems for polyolefins - can you recommend a good high temp gpc system?

    • @MalvernPanalytical
      @MalvernPanalytical  Před 2 lety

      Hello, and thanks for the question. You are correct that Malvern Panalytical no longer manufactures HT-GPC systems. While we can't make a recommendation due to lack of experience with non-Malvern Panalytical systems, Agilent offers a multi-detector HT-GPC system and Tosoh offers a RI-only HT-GPC system. I hope this helps!

  • @ravenpham83
    @ravenpham83 Před 6 lety +2

    It's really useful for me, Can I get powerpoint form for your?

    • @MalvernPanalytical
      @MalvernPanalytical  Před 6 lety +1

      Thank you for your interest,
      We thought that you'll be interested in the document below:
      White papers:
      "Static Light Scattering technologies for GPC - SEC explained"
      www.malvernpanalytical.com/en/learn/knowledge-center/whitepapers/WP130627SLSTechnologiesGPCSECExplained.html
      "Principles of Triple Detection GPC/SEC"
      www.malvernpanalytical.com/en/learn/knowledge-center/whitepapers/WP151119PrinciplesTripleDetectionGPC.html
      "Size Exclusion Chromatography / Gel Permeation Chromatography: An Introduction in 30 Minutes"
      www.malvernpanalytical.com/en/learn/knowledge-center/whitepapers/WP150625IntroToSECGPC.html
      Kyle also did a blog - www.materials-talks.com/blog/2016/08/30/an-introduction-to-gel-permeation-chromatography-in-30-minutes/
      . You can search for various blogs that will list relevant content that can help you understand better our technologies
      Happy learning!

    • @ravenpham83
      @ravenpham83 Před 6 lety +2

      Thank you so much! I hope you alway full healthy!

  • @babithabittu2137
    @babithabittu2137 Před 6 lety +2

    This really helped me a lot! thank yu soo much

  • @on-off6172
    @on-off6172 Před 7 lety +1

    Hello ! i don't understand why you're saying that it's based on hydrodynamic size , not in molecular weight ? because i thought it was all a weight matter ....thanks to your answer

    • @MalvernPanalytical
      @MalvernPanalytical  Před 7 lety +1

      Hello,
      GPC separates based on the hydrodynamic size of the molecules, small molecules will spend longer in the micro-pores of the GPC column than larger molecules, which are more physically restricted from entering. Thus GPC separates based on the size of the molecules, there is (or shouldn’t be any) chemical or physical interaction of the sample with the column.
      GPC is used to determine molecular weight, traditionally by the elution time/volume of your sample compared to that of a set of standards of known molecular weight. This method assumes that your sample has the same molecular confirmation/density as your standards and therefore an increase or decrease in size relates to a corresponding increase or decrease in molecular weight. This type of conventional calibration is therefore error prone as you sample may not have the same confirmation or density as that of your standards. Hence why Malvern advocate the use of static light scattering detectors to measure the absolute molecular weight of the sample, free of the size - molecular weight assumptions that conventional GPC relies upon.
      I hope that the above answers your question. However, if there is anything else that we can assist you with, feel free to contact us directly at your convenience. www.malvern.com/en/about-us/contact-us.

    • @on-off6172
      @on-off6172 Před 7 lety +2

      Malvern Instruments thank you very much , i'm now working on some concerning project , i'll contact you thank you 👍

    • @mohdfauzyabdulrazak9202
      @mohdfauzyabdulrazak9202 Před 3 lety

      @@MalvernPanalytical tak paham.

  • @shuhuiwu7637
    @shuhuiwu7637 Před 3 lety +1

    Thanks

  • @dineshmule6986
    @dineshmule6986 Před rokem +1

    Thank you :)

  • @user-ev5rx1cx8f
    @user-ev5rx1cx8f Před 2 lety

    😘🌞🛀🚀😭❤️🙏😀🤣