How to - remove the Vaillant F70 Fault Code after changing the PCB

Sdílet
Vložit
  • čas přidán 25. 08. 2024
  • Vaillant F70 Fault Code after changing the PCB. This video shows you how to change the DSN offset settings for the older vaillant ecotec boilers after having changed the PCB.
    If you would like to see the full Vaillant F70 Fault Code page and the DSN offset table , go to myboiler.com/f...

Komentáře • 75

  • @chucky8894
    @chucky8894 Před 3 lety +1

    Thanks, man!! All the technicians are on vacation. I have been showering with cold water for 2 weeks now. Finally fixed!

    • @MyBoiler
      @MyBoiler  Před 3 lety

      Glad to have helped, please feel free to let us know what else would be most useful to you in terms of your boiler and heating.

  • @user-qe6xd5yg8z
    @user-qe6xd5yg8z Před 6 měsíci

    Genius, thought I had purchased a duff PCB, but your video saved the day.

  • @valentinmirauta7059
    @valentinmirauta7059 Před 2 lety +2

    Your video is brilliant, I just done a PCB replacement and your guidance help me do it
    Thanks

    • @MyBoiler
      @MyBoiler  Před 2 lety

      Hi Valentin, glad it helped you. Feel free to subscribe to support us. Also this may help you myboiler.com/energy-saving/ , feel free to submit feedback for improvements. Section 2 (Boiler adjustments) is most useful for modern Vaillant combi boilers. JK

  • @guerillacity
    @guerillacity Před rokem

    Thank you, I just changed my PCB today and this really helped!!

  • @glongoid
    @glongoid Před 10 měsíci

    thank you - worked for me (Vaillant ecotec 428) - thanks for posting the video and data table 🙂

  • @NiaziAlsuleimani-zt1ur
    @NiaziAlsuleimani-zt1ur Před 4 měsíci

    Thank you 😊 , I have done self and I saved 150 pounds 😂.

  • @guerillacity
    @guerillacity Před rokem

    Thank You!!! This video was a life saver!!

    • @MyBoiler
      @MyBoiler  Před rokem +1

      Hi, really glad it saved you time and stress, and really glad to have helped. If you boiler is a combi boiler then for helpful energy saving information, please see myboiler.com/money-and-energy-saving/?source=ytc
      Section 2 boiler settings to help reduce your gas usage for condensing boilers and other tips. JK.

  • @Avdarmaly
    @Avdarmaly Před 5 měsíci

    great video. Thank you.
    My Ecotec 24 from 2013 doesn't turn on at all. Fuse on the wall is ok, I checked it with multimeter. After putting it back and turning the boiler on it worked for few seconds and then the screen went black again and no noise, nothing. Did this few times and still same. Don't know what the problem can be.

    • @MyBoiler
      @MyBoiler  Před 5 měsíci

      Faulty display and / or pcb possibly. JK

  • @joco9958
    @joco9958 Před rokem +1

    I have a Ecotec plus vcw 296 from 2014 and suddenly I have a F70 code. Does that mean my pcb is broken? How else does it not have the Device Specific Number (DSN) anymore? Thank you for helping everybody out here 👍

    • @MyBoiler
      @MyBoiler  Před rokem +1

      Hi, if it has suddenly done it, then yes, likely the board has an issue and is not able to read the dsn settings correctly, you can get an engineer to try unplugging and replugging the cables, just to make sure. JK

    • @joco9958
      @joco9958 Před rokem

      @@MyBoiler ok that makes sense, thanks for the speedy reply, I hope your business is doing well, enjoy your Sunday 🤘

  • @mikemcsweeney4753
    @mikemcsweeney4753 Před 2 lety

    Thanks for a great video.. 👍worked a treat

    • @MyBoiler
      @MyBoiler  Před 2 lety

      Glad it helped. Feel free to request any other videos that may be useful for you. JK

  • @The_Creative_Workshop
    @The_Creative_Workshop Před 2 lety

    Perfect! Thanks

    • @MyBoiler
      @MyBoiler  Před 2 lety

      Hi, so glad it helped you. If you have a combi boiler, you may also find useful our article on condensing boiler efficiency savings. myboiler.com/reducing-the-flow-temperature-for-a-condensing-combi-boiler-for-upto-8-percent-saving-on-your-gas-heating-bills/ , JK

  • @irishinlondongasengineer1687

    Lifesaver

    • @MyBoiler
      @MyBoiler  Před 2 lety

      Glad the video helped. Feel free to let us know if there are any other videos that you would like to see or improvements to the F70 webpage. JK

  • @normanpitkin8780
    @normanpitkin8780 Před 2 lety

    I have had a new pcb. I have followed all your instructions. Problem is not solved . I have hot water but heating will not work .

    • @MyBoiler
      @MyBoiler  Před 2 lety

      Hi, make sure your flow temperature is increased from default, which may be off. Which model do you have? JK

  • @markrobertson5019
    @markrobertson5019 Před rokem

    Vaillant DSN offset table

    • @MyBoiler
      @MyBoiler  Před rokem

      Offset table can be found here; myboiler.com/fault-codes/vaillant-ecotec-f70-repair/ , let us know if your particular model is missing. JK

  • @luneammeraal2013
    @luneammeraal2013 Před 2 lety

    Thank you very much for your video. But where can I find/see/check which type of eco-tec boiler I have?

    • @MyBoiler
      @MyBoiler  Před 2 lety

      It’s written underneath the boiler on the databadge. JK

    • @luneammeraal2013
      @luneammeraal2013 Před 2 lety

      @@MyBoiler many thanks for your response, but underneath the boiler is written: hrSOLIDE VHR NL 24-28/C, it does not say which eco-tec boiler it is. So I don't know which type number I have to select in the tabel on your website?

    • @luneammeraal2013
      @luneammeraal2013 Před 2 lety

      @@MyBoiler Sorry, it says hrSOLIDE VHR NL 24-28/3 C. Do you know which Value I have to choose out of the table on your website?

    • @MyBoiler
      @MyBoiler  Před 2 lety

      10 as per PCB replacement manual for VHR NL 24-28/3 C. Please note, this PCB replacement should normally be carried out by a professional. JK

    • @luneammeraal2013
      @luneammeraal2013 Před 2 lety

      @@MyBoiler thank you so much! I got it up and running again thanks to your video and your assistance!

  • @162sam
    @162sam Před 2 lety

    I have a Valiant ecoTEC pro boiler that has suddenly got an error code F76 on display. Any advice please??? We are without hot water and heating now for the 3rd day. Would appreciate any help. Thankyou

    • @MyBoiler
      @MyBoiler  Před 2 lety +1

      Hi, most likely this is caused by the boiler having overheated. This will require an engineer visit. Perhaps ring Vaillant and get one of their engineers on fixed price repair. JK

  • @AzH1988UK
    @AzH1988UK Před 2 lety

    Hi I've got a eco plus 831 what is my boiler setting?? Is it the same as you've done here

    • @MyBoiler
      @MyBoiler  Před 2 lety +1

      Follow the article shown in the description, it will help you find your settings. JK

  • @anticonformisme164
    @anticonformisme164 Před rokem

    Hello, i have a f42 error code shared with a f70, is it possible to fix it by my own ?

    • @MyBoiler
      @MyBoiler  Před rokem

      Hi, not if there are multiple errors. Usually this requires a heating professional to diagnose further. If you have already solved this, then apologies for the late reply, your message was held for review. JK

  • @gamerjonny3089
    @gamerjonny3089 Před rokem

    Replaced PCB and display as the fuse kept blowing. Did this and same thing as soon as it goes to ignite it pops. Any ideas?

    • @MyBoiler
      @MyBoiler  Před rokem +1

      Hi, hard to diagnose remotely without seeing the boiler, however usually it’s more than likely that the symptoms point towards the pump or fan. You need to test them electrically to confirm. JK

    • @gamerjonny3089
      @gamerjonny3089 Před rokem

      @@MyBoiler new water pump. Works a treat thanks very much 👍

  • @alexdinu5935
    @alexdinu5935 Před rokem

    Vaillant model es 21/245/4-5 R3 i have a F70 error... pls help !! :(

    • @MyBoiler
      @MyBoiler  Před rokem

      Hi, follow the vaillant f70 article page. If your unable to follow, you will need a heating professional to attend. JK

  • @headydeluxe4977
    @headydeluxe4977 Před 2 lety

    Hey man! I come from germany and my Ecotec Exclusive VC 146/4-7 needed a new Mainboard. Now it says the F70 fault. I need the DSN for my machine. Can you help me??
    Thx a lot. Björn

    • @MyBoiler
      @MyBoiler  Před 2 lety

      Hi, I am not able to read/speak german. However based on translation and prior knowledge I found the following manual for your boiler www.vaillant.be/telechargements/documents/notice-installation/chaudi-res-murales-gaz-1/notice-dinstallation-ecotec-exclusiv-146-206-276-319075.pdf , Page 38 contains the DSN offset (showing as DSN 6 for your boiler). If this is not the correct manual, you need to find the correct manual and locate the information this way otherwise you will need to get into contact with Vaillant technical. Please note, we cannot be held responsible for this information should problems arise, as it is provided in good faith. viel Glück . JK

  • @sa-lh8pw
    @sa-lh8pw Před 3 lety

    Hi i have vaillant pro 28 i have not got separate i button on there how do i
    Program that to the dsn

    • @MyBoiler
      @MyBoiler  Před 3 lety

      Following information is for competent persons and should be used with caution:
      Press top 2 buttons at same time ie i menu.
      Click the button shown under the spanner ie top right.
      Set code to 17.
      Navigate D code menu using plus minus buttons to D.093
      Change to correct DSN number
      Press Tick to confirm.

    • @LuisFreitas10
      @LuisFreitas10 Před 2 lety

      @@MyBoiler where do I find the dsn number??

    • @MyBoiler
      @MyBoiler  Před 2 lety

      @@LuisFreitas10 Click the link underneath the video, you may have to press "SHOW MORE"

  • @JanKowalski-bz1su
    @JanKowalski-bz1su Před 2 lety

    Dzieki

  • @subutay2011
    @subutay2011 Před 3 lety

    thanks for video. ı have protherm panther boiler. ı replaced pcb and screenboard. ı have f70 error. how do ı solve this problem. thanks again.

    • @MyBoiler
      @MyBoiler  Před 3 lety

      Hi, unfortunately this video only covers Vaillant boilers, although the protherm may use the same PCB, you will need to obtain protherm specific information and setup sequence. If we manage to find out, we will send you a reply. Jay (MyBoiler Ltd)

  • @youngen_1239
    @youngen_1239 Před 2 lety

    Which boiler type did you do this on?

    • @MyBoiler
      @MyBoiler  Před 2 lety +1

      This one is a system boiler. Older type model. Are you having issues on a particular model? JK

    • @youngen_1239
      @youngen_1239 Před 2 lety

      @@MyBoiler mine is a ecotec plus 831, i have just brought a pcb board and i am going to fit it tomorrow. Faults 61 and 62 but mostly 62. When starts up the temperature flickers from 61 to 75 on the last start up?

    • @youngen_1239
      @youngen_1239 Před 2 lety

      @@MyBoiler any advice on changing the board please? I am a refrigeration engineer by trade and have changed lots of boards on them

    • @MyBoiler
      @MyBoiler  Před 2 lety +1

      Hi, was going to say if you don't possess basic electrical skill levels then don't attempt it without caution otherwise you may break something essential. As your a professional, just remember to not force any of the components to come out or they may break, gentle prying and finding all the locking points. Make sure if you have older type vaillant, remove the display pcb. You may need to dislodge the the control knobs carefully too. Components within a boiler sometimes tend to get brittle, as they may also do in refrigeration equipment. Replacing the board is generally done in about 5 mins. The programmer takes a few minutes too. The article also contains the programming codes and method. All this information is provided in good faith, and we cannot accept responsibility as a consequence. JK

    • @youngen_1239
      @youngen_1239 Před 2 lety

      @@MyBoiler thanks for that, do i need to adjust all the settings. I thought because it was a board for the same model its just a straight swap. Only thing i have seen online is the f70 fault that you need to change? Which looks simple. When you heater knobs, do i have them on set to full heat when i detach and attach the new one.

  • @sviridov-a1586
    @sviridov-a1586 Před rokem

    Я с России братан большое СПОСИБО!

    • @MyBoiler
      @MyBoiler  Před rokem

      Добро пожаловать!

    • @MyBoiler
      @MyBoiler  Před rokem

      Also, if you have a combi boiler, you may also find useful our article on condensing boiler efficiency savings. myboiler.com/reducing-the-flow-temperature-for-a-condensing-combi-boiler-for-upto-8-percent-saving-on-your-gas-heating-bills/ , JK