F61 Vaillant ecoTEC Full Training Video

Sdílet
Vložit
  • čas přidán 12. 09. 2024
  • In this video you see me coaching a trainee about a Vaiilant ecoTEC Pro 28, giving diagnostic hints and tips using my 25-years’ knowledge and experience.
    click on this link: www.masterfule... to find out how you can download this knowledge into your brain.
    My programmes, will give you the discipline and focus you need to learn about boiler repairs, heating systems and controls. And it will give you the foundations to become a Masterful Engineer.
    That's if you're really serious about being one.
    For more detail about the wide ranging training I offer, I recommend you watch this webinar replay: event.webinarj...
    You will see two powerful ways to learn: Online Training and Hands-On Training. Together, they are the complete package for you to realistically achieve your goals in record time.
    You will need to set aside about an hour to watch his webinar.
    Share this with any colleagues or contacts in your Facebook or WhatsApp Groups.
    Coach Tony Morgan

Komentáře • 48

  • @cmavuso6068
    @cmavuso6068 Před 3 měsíci +1

    Brilliantly done.

  • @ImHowardMoonsir1
    @ImHowardMoonsir1 Před rokem +1

    I'm nearing the end of my ACS and this video is very hjelpful.

    • @ARBoilers
      @ARBoilers  Před rokem

      Hi Danny check this out.
      The Boiler Repair Library - a fantastic tool for you to increase your technical knowledge in gas and electric boiler repairs - is now only £5.00 one off payment for Lifetime Access!
      That’s Lifetime Access to hundreds of How-To and Overview videos, updated every month.
      If you are currently paying £10.00 per month you can cancel your membership and rejoin for the £5.00 Lifetime Access membership instead.
      Click here to view screenshots of the Boiler Repair Library before you join:
      arboilers.kartra.com/page/BoilerRepairLibrarySpecialOffer

  • @sevesham
    @sevesham Před 2 lety +2

    Excellent training film.

  • @ARBoilers
    @ARBoilers  Před 12 dny

    Thank you for your comments, and can you please subscribe to our channel

  • @jamesstibbs4404
    @jamesstibbs4404 Před 12 dny

    Really helpful. Thanks

  • @ozwellalford5015
    @ozwellalford5015 Před 10 měsíci +1

    Very Educational 😊

  • @ARBoilers
    @ARBoilers  Před 5 měsíci

    Thank you for your comments and can you please subscribe to our channel

  • @iftibashir
    @iftibashir Před rokem

    Does the new replacement PCB need setting up at all?
    I’ve read it could result in a F70 code which means it needs associating with the particular boiler model it’s installed into?

    • @ARBoilers
      @ARBoilers  Před rokem

      99% of the time you don't need to set anything up. Also could you subscribe to our channel

  • @ARBoilers
    @ARBoilers  Před 5 měsíci

    How long does the boiler fire for up for in heating mode ?

  • @HappyRareGrooveMan
    @HappyRareGrooveMan Před 5 měsíci

    Boiler radiators won't go hot I've tried everything it's a valient eco

  • @traleyton8057
    @traleyton8057 Před 8 měsíci

    For good part did not see the mains cable stuck underneath the mother board.

  • @thomashaslam9901
    @thomashaslam9901 Před 2 lety

    Hi I have a reading of 62 ohms? Does this mean the gas valve needs replacing? Or is it still a PCB issue?

  • @MrMarkT84
    @MrMarkT84 Před 2 lety

    Great video :) we have the same problem on our ecoTec pro 28, had f61 in the past but now seems to settle on f62, we can clear the code an resume normal operation but we also see temp fluctuations on the display (actual water temp is fine). Everything points to PCB as you video suggests, but as we don’t know the age of the boiler we are debating just getting a whole new unit (maybe different brand). Would your advice be to invest in a new boiler or just replace PCB? If PCB what’s would be a fair price for parts and instillation?
    Thanks for your video an time :)

    • @ARBoilers
      @ARBoilers  Před 2 lety

      We have replaced many pcbs on your type boiler and it should run for many years. We would charge 150 labour plus 187.00 for pcb plus vat. The pcb covered for 12 months. What area are you in?

    • @ImranKhan-hz8jy
      @ImranKhan-hz8jy Před 11 měsíci

      Do we not have to put any code into after replacment??

  • @ARBoilers
    @ARBoilers  Před 8 měsíci

    Thank you for your comments and can you please subscribe to our channel please

  • @nanjones6947
    @nanjones6947 Před rokem

    What about the pressure?

  • @waynehardiman5443
    @waynehardiman5443 Před rokem

    So you make sure the knobs hot water and heating are on full a on the pcb ?

    • @ARBoilers
      @ARBoilers  Před rokem

      Yeah 👍 Also can you subscribe to our channel 🙏

  • @pooroldpedro
    @pooroldpedro Před 5 měsíci

    careful when two wires the same colour - label with a bit of tape before you take a photo

  • @reghy2008
    @reghy2008 Před rokem

    How to measure inlet working pressure at appliance in this boiler? Is it by taking the side panel out???

    • @ARBoilers
      @ARBoilers  Před rokem

      No you need a small ratchet tool to get in gas valve inlet test point and you will need to remove the air pipe

    • @ARBoilers
      @ARBoilers  Před rokem

      Also check out this out
      www.onlineboilerrepairtraining.co.uk/

  • @infiniteloopslawson5301
    @infiniteloopslawson5301 Před 2 lety +1

    I just kept my finger on the reset button for few seconds and code went away and works fine now.???

    • @ARBoilers
      @ARBoilers  Před 2 lety +1

      Ok that's great 👍

    • @infiniteloopslawson5301
      @infiniteloopslawson5301 Před 2 lety

      @@ARBoilers it's done it before could it be a faulty sensor?

    • @ARBoilers
      @ARBoilers  Před 2 lety +1

      @@infiniteloopslawson5301 it's normally a gas valve or PCB fault

    • @okafka5446
      @okafka5446 Před 2 lety

      @@ARBoilers Got exactly the same problem (F61, with temperature jumping around when you reset) thanks for your clear video. Been told it's either the PCB OR a faulty gas valve, and that these boilers (we have the Vaillant ecoTEC plus 837 now 12 years old) have built in obsolescence, so we might as well replace the whole boiler. Not sure if this isn't upselling, but out of interest, once the pcb is replaced is the boiler good to go for a couple more years as long as regularly serviced?

    • @ARBoilers
      @ARBoilers  Před 2 lety

      @@okafka5446 100% yeah

  • @StuHNomadBiker
    @StuHNomadBiker Před rokem

    He said it was the gas valve cos that what it says in the book .. lol... see so many lads do it, can't always trust the book.... experienced lads know that there are other reasons many times that throw out the same fault... its all about learning and experience.

    • @ARBoilers
      @ARBoilers  Před rokem

      Thank you for your comments and can you please subscribe to our channel 😊

  • @sukisingh7268
    @sukisingh7268 Před rokem

    Mate i have same issue f.61 code but, its intermittent, i powered off and reignited boiler and it works fine but i may get this code again after couple of weeks so what is the issue?

    • @ARBoilers
      @ARBoilers  Před rokem +1

      It's normally the pcb or it could the gas value. Also could you subscribe to our channel 😊

    • @sukisingh7268
      @sukisingh7268 Před rokem

      Bur what if it continually works fine for months on end as it has so far by just pressing reset button?

    • @ARBoilers
      @ARBoilers  Před rokem

      @@sukisingh7268 just run with it and see how it goes

    • @sukisingh7268
      @sukisingh7268 Před rokem

      @@ARBoilers its getting worse esp. Night time it cuts out we keep resetting

    • @StuHNomadBiker
      @StuHNomadBiker Před rokem +1

      ​@@sukisingh7268 Get an engineer out to it !! Stop fishing for free advice so you can try and fix it yourself ... pay for somebody who knows what they're doing ..

  • @sukisingh7268
    @sukisingh7268 Před rokem

    Gr8

  • @sukisingh7268
    @sukisingh7268 Před rokem

    F61, constant cutting out

    • @ARBoilers
      @ARBoilers  Před rokem

      Possible gas valve or PCB

    • @ARBoilers
      @ARBoilers  Před rokem

      Also could you subscribe to our channel 😊