How To Install A Dual GFCI ARC Fault Breaker

Sdílet
Vložit
  • čas přidán 25. 06. 2022
  • #arcfaultbreakers #arcfaultbreakerinstallation #gfciarcfaultbreaker
    ARC/GFCI Klein tester amazon link: amzn.to/3wYv6P9
    GFCI Plug tester Amazon Link: amzn.to/3M4noay
    In this video series I will be discussing arc fault gfci breakers combo and how to install them and also showing you how they work. I will show you and explain wehre the wires go on the breaker and show you a demonstration with a klein dual gfci arc fault breaker tester RT 301.
    Tic Watch Link For You To Save 5% Off - bit.ly/3AilT4v
    Tube Buddy Account Referral LInk : www.tubebuddy.com/mountaineeroutdoors
    Epidemic Sound Referral link: www.epidemicsound.com/referra...
    Prolon link: bit.ly/MountaineerProlon
    use PROLON15 For another 15% off
    Fast bar link: bit.ly/MoutaineerFastBar
    Use Fast30 For another 30% off
    Here's the Nutrition for Longevity (N4L)link: bit.ly/MountaineerN4L
    Use READY60 For your first order
    ***Check out my Amazon Store Where you can help support my channel and learn about other great products that I highly recommend.
    www.amazon.com/shop/mountaine...
    My Facebook Group / mountaineeroutdoors
    Feel Free to join my other electrical only channel link is below:
    / @sparkythewindbag7074
    Cameras And Gear That I Am Using
    Canon m50 amzn.to/3h1EA1H
    Sigma 16mm f/1.4 amzn.to/344dzXL
    Go Pro Hero 7 Black amzn.to/343QWTq
    Rode Video Micro Pro amzn.to/3ay2K1E
    Comica XD Boom Wireless Microphone amzn.to/3gWHbtT
    Movo Wireless Micorphone amzn.to/2PTgeeO
    DISCOUNT CODES FOR ITEMS IN ALL OR PREVIOUS VIDEOS:
    Tryavax wallets Link For A Free Wallet With Any Purchase
    shareasale.com/r.cfm?b=179369...
    Industructible shoes for everyone
    www.indestructibleshoes.com use code MIKEG58 for 20% off
    Surviveware shower wipes
    www.surviveware.com use code MNTNRO10 for 10% off
    Ketogenic Discount codes
    www.truwild.com use code Mountain15 for 15% off everything in the store.
    Prolon link to save you money EXTRA money bit.ly/MountaineerProlon
    For an extra 15% off use PROLON15 at check out
    For the Fast Bars use bit.ly/MountaineerFastBar
    For an extra 30% off use FAST 30 at check out
    For the Longevity Meals use bit.ly/MountaineerN4L
    For 60 dollars off use READY60 at check out
    Mailing address
    P.O. Box 149
    Covington Va 24426
    Please Feel Free To Join Me On Patreon And Joining In On The Journey My Link Is As Follows. / mountaineeroutdoors1
    PayPal: paypal.me/mountaineeroutdoors
    Venmo @mountaineeroutdoors05
    Personal Email Account: comer7844@gmail.com
    Business Email Account: moutdoors540@gmail.com

Komentáře • 56

  • @seanmurnane6491
    @seanmurnane6491 Před 4 měsíci +1

    You explanation helped the most others I saw skipped showing the ground wire connection. Thank You

    • @MountaineerOutdoors
      @MountaineerOutdoors  Před 4 měsíci

      Thank you for your comment and watching. I try to be as thorough as possible. Have a great day

  • @MichaelGarcia-fe3ri
    @MichaelGarcia-fe3ri Před 7 měsíci +1

    ❤ your explanation of the gfci/gfci breaker is the best. Several other site's missed points and explanations in the amount of detail you did. Thank you

  • @richardphilpott9551
    @richardphilpott9551 Před rokem +2

    Great Video was very helpful

  • @McmM-cv9sb
    @McmM-cv9sb Před rokem

    thank for the info it was a good video I think you always have good information keep it Comin thanks.

  • @WiSeNhEiMeR-1369
    @WiSeNhEiMeR-1369 Před 4 měsíci +1

    Thanks
    COOP
    ...

  • @gregriley649
    @gregriley649 Před rokem

    Thanks for sharing 👍

  • @cesarorozco718
    @cesarorozco718 Před rokem +1

    Thankyou mi friend

  • @mikezimmerman2786
    @mikezimmerman2786 Před 2 měsíci +1

    I need them in my house

  • @blradcl
    @blradcl Před rokem +2

    Ground (bare copper), always on the opposite bar than the white? Is that what they mean by separating neutral and ground at first point of disconnect? Thanks!

    • @MountaineerOutdoors
      @MountaineerOutdoors  Před rokem

      They cannot be in contact with each other. So as long as they will not have continuity between them that is good

  • @rdrocks16
    @rdrocks16 Před rokem

    Have you installed a tandem AfCI breaker? I looked online and did not see 2 Neutral spaces on the tandem load. If you have any info on these as I have It use them? Thanks

    • @MountaineerOutdoors
      @MountaineerOutdoors  Před rokem +1

      I have not used them just single ones. Is this what you are talking about? amzn.to/3j6FjVm Seems like it would work,if you had to use it.

  • @julioanez2455
    @julioanez2455 Před rokem +2

    Congratulations for you video and share it.
    GOD bless you.

  • @chafachafita4444
    @chafachafita4444 Před rokem +1

    Where did you get does dual breaker with the purple tab

  • @Skashoon
    @Skashoon Před 11 měsíci +1

    As I understand the NEC 2020 requires these for kitchens, including dedicated circuits for the refrigerators and dishwashers, plus bathrooms. It’s odd that your local code just says bedrooms. They would be the least concerning to my way of thinking.

    • @MountaineerOutdoors
      @MountaineerOutdoors  Před 11 měsíci +1

      Well that's how we roll here. Alot of locals in Virginia are like that still. It will change though I feel certain

  • @Markdoubts
    @Markdoubts Před 6 měsíci +1

    Is that panel set up like a sub panel? In my panel the ground and neutral are on the same lug? Can I still install a dual function breaker? Thank you!

    • @MountaineerOutdoors
      @MountaineerOutdoors  Před 6 měsíci +1

      In my demonstration it is set up like a sub panel. I have definitely been to homes where I have installed them where the nuetrals and grounds were together and it did work. If you do it, let us all know if they do work for you

    • @Markdoubts
      @Markdoubts Před 6 měsíci

      @@MountaineerOutdoors Thank you ! I installed three 20 amp circuits for receptacles in my outbuilding. Also one 30amp 220. Used your videos to learn how to bend pipe. Had three 3 point saddles 😤. Wasted some pipe but got it done. Just passed my rough inspection. It will a be couple weeks before I can finish but I will let you know how it turns out. Take care.

  • @Backfire10
    @Backfire10 Před rokem +1

    Hi Sir. What is the best way to find the neutral for a 200 amp servies that is full of brakers? I have the hot, but the neutral is giving me a problem. thanks

  • @1mezion
    @1mezion Před rokem +1

    Siemens has a self testing dual function breaker

  • @maritimezhang
    @maritimezhang Před 11 měsíci +1

    So if I install this fuel. The outlets can just be a cheap one? I don’t need to buy a GFCI outlet?

    • @MountaineerOutdoors
      @MountaineerOutdoors  Před 8 měsíci

      If you do it that way, I would get the stickers that day gfci protected

  • @GloriaUribe-xn1qu
    @GloriaUribe-xn1qu Před měsícem +1

    How do you know if ones bad

  • @musiconroad203
    @musiconroad203 Před 7 měsíci +1

    I can not find Eaton 30 amp dual function GF/AF. I am confused, please advise.

  • @theoisaac9948
    @theoisaac9948 Před rokem

    👍👍

  • @Bestyslittlebro
    @Bestyslittlebro Před měsícem +2

    110 or 220?

  • @grantwhebell7730
    @grantwhebell7730 Před rokem +1

    The biggest problem with these AFCI breakers is they keep tripping , the home owner then replaces them with a standard breaker, which is bad enough, but they replace a 15 amp with a 20amp !!!!
    I have encountered this alot

  • @johnhcorwin
    @johnhcorwin Před 9 měsíci +1

    These things are so expensive. Are they really worth it? A regular breaker is like $7 and these things are >$50 and the tandem ones are close to $100.

    • @MountaineerOutdoors
      @MountaineerOutdoors  Před 9 měsíci +1

      Yes they sure are. You can't put a price on your life, plus they are code.

    • @dsantostv3711
      @dsantostv3711 Před 7 měsíci

      It would be more expensive to rebuild your house because of a fire

  • @tedlahm5740
    @tedlahm5740 Před rokem

    Sorry, did not learn anything. Trouble understanding why the digital meter was behaving in a confusing manner? thank you

    • @MountaineerOutdoors
      @MountaineerOutdoors  Před rokem +1

      I can always count on your honesty. Not sure about that meter either

  • @eddieo9424
    @eddieo9424 Před rokem +4

    Why didn't you explain what ark fault why we use them. About series parallel faults I really think you shouldn't do electrical work .

    • @MountaineerOutdoors
      @MountaineerOutdoors  Před rokem +5

      I really think you need to learn how to make a full sentence and learn how to spell 😂 😂

    • @jasonblaha6891
      @jasonblaha6891 Před rokem

      Eddie is a hater with a micro

    • @eddieo9424
      @eddieo9424 Před rokem +1

      Yes I was to busy throwing up after your video. Maybe
      You should go to apprentice school.

    • @spencerwyche2552
      @spencerwyche2552 Před 7 měsíci +1

      ​@@MountaineerOutdoorsMy guy,these guys are so fast to post a reply,that they neglect to check their sentences and such!

    • @jmtexx
      @jmtexx Před 7 měsíci

      Yeah he went into his affiliate plugs 😂