Micro Hydro Startup 2023

Sdílet
Vložit
  • čas přidán 28. 05. 2024
  • After letting the hydro system sit dormant all winter its time to get it up and running. This micro hydro turbine uses 150 feet of head pressure down 1100 feet of 2" pipe. The pressure at the PMA is around 65psi. Depending on the amount of water going to the system there is 100w to 500w of power being made. This power feeds two grid tie limiter inverters at my house to reduce the power bill to the grid.
    Please check out Langstons Alternative Power:
    www.langstonsalternativepower...
    Ram Pumps available on AMAZON
    amzn.to/2EWrQHN
    Also available on Land To House Website:
    www.landtohouse.com/rampumpsales
    Help Support land To House by Paypal:
    paypal.me/landtohouse
    Send Mail to Land To House:
    Land To House llc
    P.O. Box 323
    Micaville, NC 28755
    See whats coming up before it hits CZcams on my Facebook Page:
    / landtohouse
    Land To House is a participant in the Amazon Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com

Komentáře • 115

  • @jonclement
    @jonclement Před 9 měsíci +3

    get a label maker & add some info to your electrical. great setup!

  • @kletusbobby7029
    @kletusbobby7029 Před 10 měsíci +7

    @3:39 As I have told others, you don't need to lose any head at the drum near the water intake. You need to fit an air stand. The air stand is a vertical pipe that goes straight up from the drum, it has an open top end. The top end needs to be as high as the water intake filter. Of course, you will need to seal up the overflow and all other fittings will need to be watertight. All the air from the turbulent water rises up out the top of the air stand.
    This will keep air out of the penstock while allowing you to utilize all of the head available at the site.

  • @jamess1787
    @jamess1787 Před 10 měsíci +5

    Seth,
    Maybe install a "winter bypass"? To help you startup in the spring snd to flush all the debris/snail shells out of the line?
    I can envision a Y or a T just above your shutoff, and a smaller shutoff to divert the sludge on your first startup of the season perhaps before your pressure gauge or just after.

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci +3

      I do have a 3/4" ball valve right before the pma. I could connect a short hose there to help flush debris. Perhaps a future video.

  • @450rhino1
    @450rhino1 Před 10 měsíci +1

    GOOD MORNING SETH. Good to see you. Have a great inventive summer.

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci +1

      Good morning. Thank you. It's a summer of studio/shop building!

  • @ratannaik4132
    @ratannaik4132 Před 10 měsíci +1

    Best think 😇 good job super 👍👏👏👏👏👏 keep it up 🎉🎊

  • @00powersmoke
    @00powersmoke Před 7 měsíci

    Compound high pressure rams to drive this would be wild 🧑‍🔬

  • @verygoodvibes
    @verygoodvibes Před 9 měsíci +1

    very nice. !

  • @mosesgoiho6240
    @mosesgoiho6240 Před 10 měsíci +1

    Woohoo! Happy to see micro hydro back and running. I get a sense of fulfilment in life when I think about and practice energy generation especially hydro.❤

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci +1

      Hydro is a special animal. I should be filming a new install soon. The homeowner is about ready to make the final connections.

  • @richardblanchard2743
    @richardblanchard2743 Před měsícem

    Thanks for sharing your system setup. I have been considering using a 2 inch poly pipe but all the other videos I have seen use 4 inch pipe. It is much easier to use poly pipe and 2 inch is the largest I van find. I don't know how much fall I will have but will try to use the GPS on my phone to find out. I would like to figure out a simpler electrical setup since all that gear you have must have cost a pretty penny.

  • @lilricky2515
    @lilricky2515 Před 9 měsíci +1

    Might want to clean and lube that rotor bearing, I believe that's why you have to give it a push to get it going. It's on the yearly maintenance schedule for that model. Looking good though!

  • @workbenchz
    @workbenchz Před 10 měsíci +3

    Happy to see your Micro-Hydro up and running again. Your Unistrut braces for the barb connectors would be an easy place to attach a rebar anchor to minimize how much the penstock slides downhill each year. You might also consider adding 10-20ft extra penstock at the top, and a flat 'S' curve on the ground near the barrel, that would take up the slack of winter contraction of the plastic pipe.

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci

      Great idea on the rebar. I will need to buy a couple sticks of that and install in the fall. Placing that on the wooden structure at the top would help too!

  • @abrarcheema9105
    @abrarcheema9105 Před 8 měsíci

    Very good information ❤

  • @Oralie18Cara
    @Oralie18Cara Před 8 měsíci

    Great Job Seth! Nice to see the MH up and working!

  • @anderson.damasio
    @anderson.damasio Před 9 měsíci

    Very good! This theme is my favorite in your channel. Here in Brazil, there are many microturbines. Thank you for the content; it's always a learning experience.

  • @DanielKathungu-uf6ju
    @DanielKathungu-uf6ju Před 5 měsíci

    nice i would really like to build mine like that sometime

  • @ericprater4017
    @ericprater4017 Před 10 měsíci +1

    Great Job Seth! Nice to see the MH up and working! It's all coming together!

  • @AiMR
    @AiMR Před 9 měsíci +1

    There may be some bearings in that unit you can replace to make it run smoother.

  • @mzimmerman1988
    @mzimmerman1988 Před 10 měsíci +2

    nice video! I think you might want to do some maintenance on the turbine every year or two.

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci +1

      Very true! It was not locked up but did have some resistance at first.

    • @TerrorTubbie666
      @TerrorTubbie666 Před 10 měsíci +1

      Isn't there a greasenipple on this thing, to squeeze some grease into the bearing???

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci

      @TerrorTubbie666 I know the old one had a grease zert. I need to look closer on this one.

  • @Celeste300
    @Celeste300 Před 5 měsíci

    The wires coming out of the PVC LB should have a dripping loop which goes lower than the opening so that water doesn't enter the LB and fill the conduit underneath.

  • @paulkainer269
    @paulkainer269 Před 7 měsíci

    if you want to stop that shrink problem with pipe by using an abs expansion joint used in plumbing. its a telescopic fitting sealed with o rings

  • @sixholdens
    @sixholdens Před 9 měsíci +1

    If you don't wnat to break the handles on PVC ball valves, make a tool that turns BOTH handles from a piece of PVC that will fit over the top of the valve you want to turn. Make it about a foot or two long and cross drill it at the top so a piece of rebar or EMT conduit will fit making a handle that will give you better leverage than the PVC handles. Cheap as they are you can make one for every location you have a PVC ball valve. Also next time you clean out a a nozzle, be sure and flush the supply line!!! Otherwise it will just clog up again. Hopefully you took the other comments to heart and replaced the bearings in that turbine.
    As for your water exit problem, you need to open up the bottom of the box and let the water get away from the wheel. I haven't seen any other turbines that are set up to contain all the water and try to force it into a drain pipe right at the turbine wheel. Give it a foot or so and then try to pipe it off.

  • @JoeyGlover
    @JoeyGlover Před 10 měsíci +2

    Great video Seth, I'm over in North Wales (UK) living in the snowdonia nationial park, I've been a absorbing your content for a while, slowly specing out my own attempt. This was a great video that really showed what I could be looking at with the head pressure and flow rate we have available to us here.

    • @jonpatterson7211
      @jonpatterson7211 Před 9 měsíci

      Joey, I was in Corwynn back in the early 80's. Stayed at the Owain Gwyndlar hotel, which at the time was run by an absolute gentleman by the name of Corrie Williams. I'll guarantee I've misspelled all the names except Mr. Williams', so I hope you'll forgive me for that. A buddy and I had come up from the American air base in Suffolk to fish, but owing to some bad info from the base Rod and Gun Club, we missed the trout season by a week. We stayed for a couple of days in spite of that, and had a wonderful time. We hitchhiked up to Bala Lake and camped over night. What a beautiful place. Mr. Williams treated us like family when we returned. Here in my home state of North Carolina, you'll find a lot of Welsh names like Morgan , Davis, and Jones, mostly concentrated in the mountainous western end of the state where I am from. I often wonder if perhaps the immigrants from North Wales pushed inland, found our mountains reminded them of home, and just settled there. All speculation of course, but you never know. I'll never forget my trip to North Wales and the hospitality we were shown. All the best to you and yours, sir.

  • @royamberg9177
    @royamberg9177 Před 10 měsíci

    Ratchet straps to hold pipe from settling down hill. Tree handy

  • @chikambambam3492
    @chikambambam3492 Před 10 měsíci

    Great

  • @johndoe-hf6zn
    @johndoe-hf6zn Před 6 měsíci

    Seems like you should have more watts. Ive considered trying a semi truck alternator as they run at lower rpms than car alternators.

  • @GlenS123
    @GlenS123 Před 10 měsíci +2

    Sounds like bearing are getting dry, may be time for some new ones.

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci +1

      It does sound that way! I Need to talk to Langstons and see about greasing those.

  • @David_Mash
    @David_Mash Před 10 měsíci +1

    I keep getting black beetles, larvae, and leeches in mine

  • @carterhobson310
    @carterhobson310 Před měsícem

    Nice setup! Will any mppt solar charge controller work for this application as long as the input voltage matches what its rated? I’m looking at Victron Energy systems

  • @liam3284
    @liam3284 Před 8 měsíci +1

    100 watts adds up when it's 24 hours a day.

  • @larrymercer4667
    @larrymercer4667 Před 10 měsíci

    Im concerned of the voltage drop to yr home.250 feet.u may need much heavier cable.Check voltage and current at each end of the cable.V good skills.Larry Mercer. Electrician. NEW ZEALAND.

  • @greenbimoon
    @greenbimoon Před 10 měsíci +2

    Try Neoprene as a water seal gasket!
    Is that all DC from the Hydro to your charge station?
    Or AC then rectifier?

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci +1

      That might make a good seal!
      This is 3 phase ac from the pma to the house. Then rectifier.

    • @greenbimoon
      @greenbimoon Před 10 měsíci +1

      @@LandtoHouse Perfekt, tack

  • @AHMEDGAIUSROME
    @AHMEDGAIUSROME Před 10 měsíci

    gg my dude !

  • @hussitewagoner6838
    @hussitewagoner6838 Před 24 dny

    Is fire hose viable to utilize instead of poly pipe ?

  • @Jkauppa
    @Jkauppa Před 10 měsíci +1

    one gnat it the eye in a day is healthy lol

    • @Jkauppa
      @Jkauppa Před 10 měsíci

      diy is meant to be super cheap, not high dollar

    • @Jkauppa
      @Jkauppa Před 10 měsíci

      diy life off-grid is very much free

    • @Jkauppa
      @Jkauppa Před 10 měsíci

      gravity plumping sewage power lol

    • @Jkauppa
      @Jkauppa Před 10 měsíci

      snail wins over economy hare always

    • @Jkauppa
      @Jkauppa Před 10 měsíci

      sewage system better not glogg with snails, have it work with wide diameter systems, less maintenance woes

  • @st.odinson
    @st.odinson Před 10 měsíci

    Okay, so now we take these and install them on all city water shut offs to homes and buildings and would that not generate power for the building?

  • @thomasthompson2084
    @thomasthompson2084 Před 2 měsíci

    What kind of temperature can those handle im looking for something that could deal with around 250 degrees

  • @jmackinjersey1
    @jmackinjersey1 Před 10 měsíci +1

    Are you thinking aboit adding either another line all together, or at least have another manifold and 55 gal drum set up at the top to feed the current line?

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci +2

      I could benefit from a larger pipe or a 4th 1-1/4" pipe but for now my water flow is so low this 3 pipe setup is working well.

    • @jmackinjersey1
      @jmackinjersey1 Před 10 měsíci +1

      @@LandtoHouse Gotcha. I guess like anything else, you have to weigh the cost of the entire project with the total output. You know, the cost/benefit analysis.
      I know the round about cost of everything up to the "turbine generator", and I also do not know how much each one of those produces. But we all know that every little amp helps.

  • @questionblechoices
    @questionblechoices Před 9 měsíci

    I have a question, since Tesla turbines produce the most torque at lower pressure could you used one for something like this and get a better output?

  • @davey2k12
    @davey2k12 Před 10 měsíci +1

    Self cleaning yeh clean it yourself 😜😁😁😁

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci +2

      HAHA I mean it went all fall without catching a leaf. Not bad. My old screen would be blocked in a day.

    • @davey2k12
      @davey2k12 Před 10 měsíci

      @@LandtoHouse wish I had a backyard with a stream I'd be doin the same ting 😄

  • @alltheboost5363
    @alltheboost5363 Před 10 měsíci +1

    You need to use some unscented Aqua Net Hairspray. Lol I realize how that sounds but I bet you'll have little to no problem with that pipe coming off. It doesn't take much just a little spray on the fitting let it sit for 30 seconds put the clamp pipe back together and it'll be glued. But it's still comes apart if you loosen the clamp.

  • @KanaloKrawallo
    @KanaloKrawallo Před 12 dny

    I tried the same in Germany, but I didn‘t get a permission for water usage…are all the installations on your privat property? Because here, such installations in public areas need a permission which is very expensive and you wait for some months or years to get it…

  • @ShemBoothSpain
    @ShemBoothSpain Před 10 měsíci

    Based in japan and thinking of something like this in our area, we have a lot of tiny rivers that run down the mountain, any advice?

  • @mengiealcano1159
    @mengiealcano1159 Před 7 měsíci

    how much cost for the battery,inverter,ang midnite and other devices do you used it?thank you

  • @nielnielsen5284
    @nielnielsen5284 Před 10 měsíci +1

    Why doess the turbine gain speed significantly when its lid is closed? Thanks.

    • @johnstuart3851
      @johnstuart3851 Před 9 měsíci +1

      Because the alternator cooling fan airflow is unblocked with the lid open, adding load on the turbine.

  • @mygadgetzhaiqal7410
    @mygadgetzhaiqal7410 Před 8 měsíci

    May i know the RPM for that turbine? Is the Open Voltage produce about 180v? When MPPT start to work, its drop to 80v right ?

  • @danielson101
    @danielson101 Před 8 měsíci

    what rpm can it run at?

  • @climbnc
    @climbnc Před 5 měsíci

    Do you know what your real world voltage drop is with 50-100 VDC over 250 feet? Between the turbine and the house?

  • @robsim4692
    @robsim4692 Před 3 měsíci

    For only 25k you can get yourself one and it will pay for itself! In about 18 years! If it doesn't break before then!

    • @LandtoHouse
      @LandtoHouse  Před 3 měsíci

      Alternative power stuff is expensive. I have a cost breakdown video on this system. (shows the difference in real cost vs free youtube items too)

  • @celtshaun1427
    @celtshaun1427 Před 10 měsíci +1

    Why have you not incorporated an expansion loop to inhibit the issue of the poly pipe pulling out? Simple fix.

    • @andrewallason4530
      @andrewallason4530 Před 9 měsíci

      My thoughts exactly. A simple, coiled loop of the pipe, lying flat. Problem solved.

  • @tonywillingham8109
    @tonywillingham8109 Před 9 měsíci +1

    How large a ram pump would you need to run this is if the ram pump and the turbine where at the same level?

    • @LandtoHouse
      @LandtoHouse  Před 9 měsíci +1

      To supply 30gpm you would need a ram pump at least 2 feet wide. It's actually better to let the water flow into a turbine without a ram pump.

    • @tonywillingham8109
      @tonywillingham8109 Před 9 měsíci +1

      @@LandtoHouse I was just curious if you could make your own head if you didn't have any.

  • @TylerHVAC
    @TylerHVAC Před 10 měsíci

    Hey Seth, I'm thinking about purchasing a ram pump. Im going to run a siphon over my dam for my pond and have it fill a bucket that will have more pipe come out the bottom (just about 9 feet of drop) to feed the pump, I will run it back up the dam and feed a barrel like the kne in this video. Do you think it will work if not i would like some tips please and thank you.

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci

      Hello. If you are siphoning water out I would make sure there is plenty of water going into the pond from the source. Siphoning can pull lots of water out. Once you know the pond will stay full you should be good to go. It is wise to siphon to a bucket then use pipe from the bucket. This results in a stronger pressure wave.

    • @TylerHVAC
      @TylerHVAC Před 10 měsíci

      ​@@LandtoHousealso to help the pond out I will have and over flow pipe go into an overflow pipe, luckily it is only used when the main is clogged. Any idea how to conserve some of the water coming out the waste valve?

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci

      The waste valve is pretty much gonna use a consistent amount of water period you can tilt the valve so that the pump closes with less pressure and that will use less water. But not much can be done to reduce the waste water output.

  • @ahmadkholiksulistyo7364
    @ahmadkholiksulistyo7364 Před 10 měsíci +1

    did you do any mathematical calculations before system installation? if yes, can you show me?

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci +1

      I just did the basic calculation
      (Head in feet X Gallons per minute) / 10 = power

    • @st.odinson
      @st.odinson Před 10 měsíci

      Math?
      Pipe up more than 0° this way ^ then water goes down that way v + more up = more better power

    • @ahmadkholiksulistyo7364
      @ahmadkholiksulistyo7364 Před 10 měsíci +1

      @@st.odinson I mean how much exactly power made up from water so you can choose or design the turbine and generator with maximum efficiencies

  • @pedalandfly3568
    @pedalandfly3568 Před 5 měsíci

    what do you call that motor?

  • @edmundogonzalez1124
    @edmundogonzalez1124 Před měsícem

    Muy práctico pero todo lo q dice no entiendo , me gustaría q hablará español. Gracias

  • @TheITSNOTGOOD
    @TheITSNOTGOOD Před 10 měsíci +1

    How much does a complete system as yours cost to set up. Ish

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci +1

      I made a cost breakdown on the system both my cost and a non youtuber cost
      czcams.com/video/L16s6aUJ0ns/video.html

  • @ericprater4017
    @ericprater4017 Před 10 měsíci

    I was talking with my pump guy and I was considering using a generator to power the well when whenever we had a black out, I asked about 120v pumps, he said all he would have to was to run heavier wire to the pump to make it work.

  • @user-dy9zy5kr5p
    @user-dy9zy5kr5p Před 10 měsíci

    5:32 wetland filter

  • @nathanieljames7462
    @nathanieljames7462 Před 9 měsíci +1

    Total $ in materials for half a kw must be insane

    • @shawnd567
      @shawnd567 Před 9 měsíci

      400watts x 24 hours ~ 10kwh per day

    • @andrewallason4530
      @andrewallason4530 Před 9 měsíci +2

      Way cheaper than connecting to grid in semi remote areas, let alone no-grid areas.
      Friend of mine was quoted $60K to connect to grid in 1982. They went off grid for about $5K then (mixed solar and mini-hydro, with a marine wind turbine (one of the ones you see on 30-50” yachts).
      They have been saving a couple of grand every year since then, let alone the $55 THOUSAND dollars (or so) they saved up front.
      The only upgrades have been new batteries and inverter in the early 90s and new batteries again about 5years ago.

    • @nathanieljames7462
      @nathanieljames7462 Před 9 měsíci

      @@shawnd567 Do you have a degree in mathematics? That is an incredible bit of estimation you did there, Professor!

  • @benoitmorin7008
    @benoitmorin7008 Před 10 měsíci +1

    Any project to make sure you collect all the water possible at the intake like a dam? :)

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci +2

      On this hydro unit the water is all making it into the coanda.

  • @errolfoster1101
    @errolfoster1101 Před 8 měsíci

    Why don't you use agricultural compression fittings they will handle all of your pressure plus the do not pull apart I used those type that you use and never had much success with them like yours they usually pull of or split

  • @thormeyer6198
    @thormeyer6198 Před 10 měsíci +1

    That bearing sounds bad…

  • @insert1coin436
    @insert1coin436 Před 10 měsíci +1

    Parts list?

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci +1

      I installed this around 3 years ago. I have a video that walks through each component but no list of each part.

    • @insert1coin436
      @insert1coin436 Před 10 měsíci

      @@LandtoHouse thank you I appreciate it

  • @ItsTOUGHtobeFascinating
    @ItsTOUGHtobeFascinating Před 10 měsíci +1

    My dad has found snakes in his

    • @soyews
      @soyews Před 10 měsíci

      They will seek the cool water when it gets hot.

  • @james10739
    @james10739 Před 10 měsíci +1

    It seems like if it wants to sit down 6 inches youd be better off just adding more pipe because it will want to pull back down

    • @LandtoHouse
      @LandtoHouse  Před 10 měsíci +1

      Last year it sank down 3 feet! I am much happier with only 6 inches this year.

  • @ultrastoat3298
    @ultrastoat3298 Před měsícem

    This seems like a pretty fragile system.

  • @user-ml3yf7pg7g
    @user-ml3yf7pg7g Před 4 měsíci

    Land to House Wow, it seems that you are mechanically challenged. It is amazing how amateurish your set up is. I thing you are going to have lots of reliability issues.
    Hope you can learn fast.

  • @ralphday4842
    @ralphday4842 Před 10 měsíci

    Awful lotta effort for something so stupid.
    Simply pay your monthly light bill . Problem solved ! 😎

  • @simeontoboly-tb7xo
    @simeontoboly-tb7xo Před 8 měsíci

    Hi Seth, would it be possible for you to send me your email address so I can directly communicate with you. I'm very interested in such a project.
    Thank you.

  • @colinhamer6506
    @colinhamer6506 Před 10 měsíci

    We have a river running under our property and a old wheel pit the river drop's around 8m on our property it enters from a tunnel is open for around 100m and then enters a tunnel around 100m long under our buildings and then opens up again into the wheel pit if you put this into Google maps and satellite images you can see what I mean 53.694212,-2.206509