Columns sizes for various floors | building design | civil engineering | youtube | column design |
Vložit
- čas přidán 20. 08. 2020
- #civil_engineering #youtube #column_size
Join this channel to get extra benfits :
Memberships link
/ @civilengineeringbyshr...
In this Video lecture you are able to learn about Columns sizes for various floors | building design | civil engineering | youtube | column design |
-----------------------------------------------------------------------------------------------------------
In this channel you can learn about online civil engineering softwares. So Please subscribe my channel for more interesting videos.
-----------------------------------------------------------------------------------------------------------
To subscribe my channel click on Red Button and also press the Bell icon.
----------------------------------------------------------------------------------------------------------
We are providing Civil engineering academic Mini/ Major projects for Diploma, B. Tech and M.Tech students along with paper publishing in Non-UGC, UGC, Scopus index journals interested people can reach me through my mail.
Plagarism check in Turnitin software
Note : Documentation, PPT will be provided as per students requirements.
Mail ID : civilengineeringbyshravan@gmail.com
The following links are some titles for B. Tech and M. Tech Academic projects
B.Tech Major project list : drive.google.com/open?id=1Jty...
M.Tech Project list : drive.google.com/open?id=1m1b...
Follow me on social Net works
---------------------------------------------------------------------------------------------------------------
1) Face book page: / civil-engine. .
2) Twitter page : / engineeringby
3) Instagram page : / civil_engin. .
-------------------------------------------------------------------------------------------------------------------
Subscribe to my channel by using below link
czcams.com/channels/PIu.html...
------------------------------------------------------------------------------------------------------------------
Hi Shravan. its an excellent information about column size for each floor. Can you also share your knowledge of size of iron rods for each of floor. For example for G+2+penthouse along with column size 12inches , 14inches what should be the mm of rods to be used
Intelligent boy, thanks for ur explanation
Good job Amigo!!! Muy bien trabajo!!! Saludos desde Las Terrenas RD.
Thank you
thank you for speaking english
Why?
Great content. Thanks
Can you explain about placement of column and orientation of columns with respect to major and minor axis of the beam .
Let's say you have a rectangular building, the major axis of the column will run parallel to the transverse or short side of the building.
This way the major axis of the column faces the direction of lateral loads like winds or seismic.
After this major arrangement, architectural considerations will make you change a few of them that's all.
Thankyou so much sir . Very helpful information 👍👌
Good explanation and very useful.
Thank you 😊
Bro could you explain about how many bars will provide for each size of column please explain
Can we change the column sizes while moving above stories considering economic design or it is preferable to keep column size constant and reducing the reinforcement percentage?
Yes brother I was explained example in video please watch completely
Thank you sir, It was really interesting and would you tell me please the difference between 3B+G+3 and 3G+B+3. I will be very thankful!
Also add required Bars needed for those column size.
thank you sir for the information
For residential building the coloumn sizes will obstruct movement so can we convert it to max width of 12"X as required.
Hi Shravan. its an excellent information about column size for each floor. Can u share how to design coloumn for G+1 RCC residential building
sir please make a video on PILE DESIGN as per the SUPER-STRUCTURE..
Sir what can you suggest regarding the column size and its distance to each other for a 40 storey hign rise building?
Dear Sir
Myself a senior civil engineer with over 35 yrs field diverse experience.Please differentiate between pro & coins of different design software in a TABULAR FORM and your personal experience in using various software and recommendations thereof.Thanks
Definitely Ravi sir I will make it 💪🏻
Thanks
its better to retire
Thankyou sir
Thanks brother, nice information
Sir, can i reduce column size after finishing 3rd floor or 4th floor?
NB: the building is design for 8 floors.
yes u can
I have planned to construct two separate rooms like 20*10 ( ground floor with 10*14 room size at first floor) & 22.5*10 (only ground floor) . My engineer suggested RCC is as follows. Pls tell it correct or not. Basement level of 22.5*10 is 2 feet less than 20*10 room
1. For 20*10 - 6 columns of 12*4 with 8mm stirr up of 7 inch c/c - four at each corner and remaining two at spacing of 8 feet at one end and 11 ft at other end. Plinth beam with 1.5 feet height and 9*9 (l*b). Ceiling height is 10 feet. Planned tie beam at below windows (2.5 feet) and lintel (7 feet) of 6 inch rcc
2. For 22.5*10 - 6 columns of 12*4 with 8mm stirr up of 7 inch c/c - four at each corner and remaining two at spacing of 10 feet at one end and 10 ft at other end. Plinth beam with 1 feet height and 9*9 (l*b). Ceiling height is 12 feet. Planned tie beam at below windows (4 feet) and lintel ( 8 feet) with 6 inch rcc
And join the both room in ceiling and both room in 90 degree position to each other
Bro distanse between column to coloumn and no of bars and their size and stirupss c/c
Nice 👍
what about span length?
I used 6 piece 16 mm bar and column size 250 x 300. Can I build G+2 with this specification
try to use 8 bars 6 bars with 16mm is only enough for G+1
Sir, from what story level wind load and earthquake load should consideration.
is it the same for residential constructio in hilly areas?
I have G+2 home which has 9"*18" column and used 16mm-2 qty and 12 mm -2qty steel size. And distance between two column is 13 feet then it is stable for load?
Can we increase length of column instead of width like 600 x 600 to 300 x 900 mm
As I had worked as site engineer in a project of 21 floor but there I had not seen column width 700 x 700 instead the column length was big
And they had reduced the size of column as floor increased like from GL to 10th and from the 10 the 15 the floor different small size so on
THANKYOU SIR. IT IS HELPFUL.
Most welcome
Thank you Sir
i think the column size depend on span to / what is the minimum span for your personal experience explanation
Yes... It depends on various factors...
I think that sizes is sufficient for 10-12' span
Dear sir 6/12 inch piller how many floors load this piller
Pls replay
Sir, I did complete building in etabs , while run analysis IAM not getting displacement function in the bottom of scroll ball
can u send me screen shot to my mail
Best video dear vai
Good information sir
Thanks
Hi sir we are building g+2 using 9 inch column......this building have come more lifespan or not..... please tell me
Very helpful info. This channel is my favorite keep teaching pls engr.
I really appreciate
Thank you
I mean to say G4 you said on mm for G3 pls correct it
It totally depends on the loading also have to check the deflection
Sir kindly make VEDIOS in design of pile,Matt, eccentric footing....
Please sir I have asked this questions so many times
So kindly make sir
how can I cont. you regarding RCC construction like slab col. beams
Can you clarify If Iam building G+ 1 now and in future if I want to expand till 4 floors Can you let me know Column Sizes Thanks
Brother, for the 9x9 inches ground column, what is the maximum distance spacing between 2 columns? thank you
Alreay made a video on it please check in playlist yar
Maximum distance is 3 to 5 meters
@@drsteviejasengnsangma8739 thank you sir
Very nice bro
Thank you 😊
Sir, for G+2 residential building I consider 350*350 mm column, but bar area coming up to 2700 mm2. and unfortunately higher bar in upper floor. Please suggest, how to solve.
But I think in actual it depends upon load location and seismic zoon of building
Please tell is tata tiscon steel good for house construction??
Floor height is a critrria to be adopted for fixing column size.
I have designed g+3 with beam width 250 so what should be the dimensions of columns?
Thanks bro
Welcome
Add pictures and video footages when u talk regarding particular column sizes
ok
Sir...
Please explain by assuming 9" constant....
Like 9"×9", 9"×24", 9"×30"
Yes
What should be reinforcement for 18 by 18 column size?
Thanks you for sharing your experience and knowledge 🙏🙏🙏
Thank you 😊
Would u mind to engineering a building g plus 3
The size of column also depend upon the distance between either sides of the columns, what reference are you giving this speech upon?
What is quantitative estimate of footing of G+3 building ?
Hello sir , how to design eccentric footing foundation in staad pro..?
Dia & No. Of steel also mark in each story
what about the span ????
column size according to the spans ????????????????????
Hi sire i have column size 35×35 for G and G+1 FOR G+2 i have reduced the size to 30×30 can i added a G+3 ???
for G + 9 all floors' columns should be of the same size?
yes but you have to consider design considerations
👏👏
Superb
Thanks 🤗
Kindly give any calculation of thumb rule to arrive preliminary size of rcc column for any storey building. Load= plinth area of slab area x no. of storey x thumb rule for load/m^2. After that using formula given in IS456-2000
Pu=0.40fck Ac+ 0.67 fy Asc. By assuming percentage of steel from 1 to 2% and assuming grade of concrete and steel grade , Ag gross area of column area will be arrived. By assuming square or rectangular column dimension of column wi be arrived. As a thumb re we may assume 10 to 20 kn/m^2 may be consider as thumb rule Normall we adopt 15 Kn/m^2 is consider for design. Like that kindly give some guidance to arrive size of rcc column from your field experience.
V.M.Rajan.
What footing size for different columns
Great
Could you please do a flow chart for general loadings as well as loading combinations " Live load. Dead load & wind load" on building structures using STADD Pro. The principles to enter data into STAAD pro are very similar regardless if it is G+1 .... G+10 etc. General load distribution "Slab+wall to beam to column to foundation to soil". Thank for all your hard work and appreciated!
Sir please provide soft copy for design steps of multi story buildings...
G+2 residential building ke Liye ground floor beam ke liye kitna mm ka rod use kare.
Beam size 250× 400 mm please reply
Sir I have 5000 sqft area how many floor I can build with a unground and ground floor
Hi, brother i am working now in site supervision field, iam interested to change in designing carrier , is there any online courses you can suggest to lern designing using e tabs or any other
I will start online course by May or June I will update that soon in our channel stay tune
Similarly explain sizes of beams???
Definitely I will
@@civilengineeringbyshravan9596 dont forfet to consider span
What is size of beams of the various story buildings
hi brother can tell me G+10 building special shaped column size?c/c distance?
The column size of two storey house is 300x300mm with 8pc 12mm bars. Can I add 1 more storey to make it three?
Yes u can fir these 300X300
I want to join as a member but can u first answer my query.is 10x14 good for g+4 residential 3bhk 1600sqft building
Supppeerrrr
Thanks 🤗
Sir. Please do design with excel
You didn't told about 9"x18" size that is mostly used
I said it’s only my personal experience not exact values u can use that 9x18 also 💪🏻
Sir Mere building mai column span maximum 11 ft hai...all colum size 10 inch * 10 inch hai...steel 16 mm 4 nos & 12 mm 2 nos hai...kya mai 3 storey buildings bana sakta hun....now it's G+1.Soil is very good
Square pipe box square columns and raound column s for circle box in size by size supposed hight growth about tree floor box thikness 3 mm ,9 floor for 4 mm ,15 floor for 6 mm such can do it ?
Hi bro plz reply my question my house span between two columns 19 feetlength, wedth 14 feet . Column size is 9/15 with 6 bars of 16mm rectangler shape.and we make all walls before slab with size of 9”. And we put 12mm bars concealed beams . Total slab area is 45*36 feet total colums 9.
Middle columns lean wall 14 “
It is safe or not plz reply bro
Only single story G+0
Sir mera house 3 rd floor....g+2.....550 sft a...calom 9ta ....10/10...r 16 mm 4 pic kora ....khuch prblm hoga sir ...plz anrs??
How about the distance of column to column?
What about distance between one calumn to other?
Generally we will take it as 10 to 15feet
Minimum 5m
sir plz reply karna humble request.
mera 1100sqft ka ghar hai. bina engineer recommendation se banaya gya hai.
1.total 9 pillers.
2.3 storeys.
3. all 8 pillers 12x10 ,only middle piller 12x16.
Sir is it ok? ya strength kam ho gya hai?
Nice
Thanks
Interesting
Thank you
Where do u put 9x18 " ??
Sir how can i contact you
Bhai jaise jaise building bante jaye column ka size km kr skte hai???
sir ek video staad rcdc pr bhi bnao .....
Definitely I will in update as soon as possible
@@civilengineeringbyshravan9596 ok....sir
Sir what will be the span?
Language 👍👍
Ty
If G+1 column Size is then Plinth Beam Size will be ??
please discribe about using steel as per piller.
Please watch videos in our channel i was already uploaded that videos
Please can you explain how to install the columns
Sir please tell us the minimum distance between two column?