    In this video we are going to see about the mistakes in column what we are doing in site and also it enclosed about column shape ,size and rebar for that column
    Column is one of the back bone of building to ensure the durability of the building we should have to design column based on the loads
    so while constructing a building it is recommended consult a structural engineer or Engineer with quiet good knowledge in structural detailing
    #Column ல இவ்வளோ தவறு செய்யரோம்மா
    Distance between two column in tamil
    #Column கம்பி கணக்கிடு
    #Distance between two column in building
    #civil in tamil
    #different types of column in tamil
    #column bar calculation
    #column shape and size
    plz like share and subscribe
    thank you

Komentáře • 59

  • @ganesanmala8746
    @ganesanmala8746 Před 2 lety +7

    அருமை. அனைவருக்கும் எளிமையாக புரியும் படி தெளிவாக உள்ளது. உங்கள் முயற்சிக்கு வாழ்த்துக்கள்.

  • @jeenjk2505
    @jeenjk2505 Před 5 měsíci +1

    Very useful video bro...ithulam na therinjikka 5 yrs aachi bro...so very thankful

  • @pradeepstunner518
    @pradeepstunner518 Před 3 lety +6

    wowww👌🏻👌🏻 vera level brother... easy to understand😇

  • @hariarul585
    @hariarul585 Před 2 lety +1

    well explained . thanks. keep continuing

  • @nevergiveup5784
    @nevergiveup5784 Před 3 lety +4

    Superb bro..well explained..informative content..keep rocking..👍

  • @Sakthis007
    @Sakthis007 Před rokem +1

    Relly romba useful வீடியோ சகோ 👏👏👏💐

  • @kumarasamy4111
    @kumarasamy4111 Před 2 lety +1

    Superb

  • @iFindEvil
    @iFindEvil Před 22 dny

    Cool👌🏻

  • @arthichandrasegaran3071
    @arthichandrasegaran3071 Před 3 lety +2

    Keep going bro😌

  • @SivaKumar-ls3bj
    @SivaKumar-ls3bj Před rokem +1

    Super

  • @esjesus8943
    @esjesus8943 Před 3 lety +4

    Nice video bro👍

  • @mcm5937
    @mcm5937 Před 3 lety +3

    Super pa

  • @kiruthikakittu5799
    @kiruthikakittu5799 Před 3 lety +2

    Good 👏

  • @ramuramu-gj1nd
    @ramuramu-gj1nd Před 9 měsíci

    I liked your comment thank you

  • @sakthilingam643
    @sakthilingam643 Před rokem +1

    Super anna

  • @dharanidhamarai2545
    @dharanidhamarai2545 Před rokem +1

    🙏👏👏

  • @jeenjk2505
    @jeenjk2505 Před 5 měsíci +1

    Bro but vera oru video paarthen but avunga colum middle ahh avunga stirups spacing kammiya kudukka sonnanga but neenga middle than bending moment 0 so spacing athigama ahh kuduthukulanu solluringa

    • @civilcognitionintamil8634
      @civilcognitionintamil8634  Před 5 měsíci

      Yes bro, correct
      Column centre la bending moment zero so athanala athumari namba pannalam.
      Eg. Column Center la (L/4) distance 150mm c/c spacing use pannalam , top and bottom (L/4) la 125mm c/c spacing use pannalam (this spacing are just for assumption)

  • @thirumurugan5270
    @thirumurugan5270 Před rokem +1

    சூப்பர் மிக அருமை 1 1/4
    3\4 எத்தனை கம்பி இருக்க வேண்டும் தம்பி

    • @civilcognitionintamil8634
      @civilcognitionintamil8634  Před rokem

      தோராயமாக g+1 கட்டிடத்திற்கு 1'3"x9" - 16mm - 6nos அல்லது 16mm - 4nos & 12mm- 2nos போதுமானது.

  • @Traveldiaries_hk5cw
    @Traveldiaries_hk5cw Před rokem

    Column cover should be 40mm which means 1.5” approx

  • @darshananbu4037
    @darshananbu4037 Před rokem +1

    Maximum percentage of steel 4% not 6% as per is456 code. Can't pour concrete properly if provide more steel.
    Darshan (Structural Engineer)

    • @civilcognitionintamil8634
      @civilcognitionintamil8634  Před rokem +1

      Yeah as per is 456 the area of longitudinal reinforcement in column must not be less than 0.8% and must not exceed 6% of column gross area but however in practice, maximum reinforcement of 4% is recommended

  • @dhanushkodi7861
    @dhanushkodi7861 Před 4 měsíci

    15 feet distance vandha column size epdi podanum bro...

  • @infantmanickaraj2330
    @infantmanickaraj2330 Před 2 lety +1

    Bro ithu maathiri beam ku video podunga bro

  • @sunithavenkat3897
    @sunithavenkat3897 Před rokem +1

    hello sir. one feetla paarai 4 feet pallam.irukra placela G+2 houseku endha size kambi pillar podavendum.

  • @jules8063
    @jules8063 Před 11 měsíci

    Hi bro
    Nanga kattura veetula first floor column, ground floor column size vida chinntha iruku. 1 or 2 inch reduce pannitanga. Is that recommended?

    • @mohanv4916
      @mohanv4916 Před 10 měsíci +1

      Its Not big problem....
      Load reduce panirupanga....
      Suppose 3rd floor build panina prblm varum.... Only 2 floor no prblm

  • @praveenkumar-xw8de
    @praveenkumar-xw8de Před rokem +1

    9*9 column g+1 ok vaa bro

  • @mithrannila2018
    @mithrannila2018 Před 2 lety +1

    sir en veedu 220squre feet
    6 Calume poatangha .
    1 Calum 12mm 4 numbers poatangha sariya?

  • @shanthimani8660
    @shanthimani8660 Před 6 měsíci

    600sqft 12 columns 4nos 12mm rods 2nos 10mm rods this correct or incorrect

  • @iam_mohans6794
    @iam_mohans6794 Před 2 lety +1

    Sir, outer to outer 11.5 ft ku 31 ft 1 bhk katrom athuku 9 " by 9 " post pothuma future la maximum 2 floor kattuvom athuku 9" by 9 " post pothuma sir please reply

    • @civilcognitionintamil8634
      @civilcognitionintamil8634  Před 2 lety +2

      Sir
      9"*9" column oru maadi (g+1) building ku pothum
      G+2(2 floor) building ku 1'*9" column 10ft distance la kudunga pothum
      Mukkiyamana vishiyam roof la beam kudunga

    • @iam_mohans6794
      @iam_mohans6794 Před 2 lety

      @@civilcognitionintamil8634 okay sir Thank you so much sir

    • @iam_mohans6794
      @iam_mohans6794 Před 2 lety +2

      @@civilcognitionintamil8634 sir g+2 floor ku 9" by 1' post ku enna size rode podanum

    • @raghuprasath7631
      @raghuprasath7631 Před 2 lety

      @@civilcognitionintamil8634 thank you sir

  • @mohanv4916
    @mohanv4916 Před 10 měsíci +1

    45*d
    45*16=2.5f
    2.5f எப்படி வந்தது....???
    புரியல

  • @ashokdavid108
    @ashokdavid108 Před 3 lety +2

    Column gap athigama vuta top load atgugama irutha danger dhana

    • @civilcognitionintamil8634
      @civilcognitionintamil8634  Před 3 lety +1

      G floor ku 15 ft varayu prblm varathu(9"*9") ok ......bt (g+1) ku 15ft ku (9"*9") set agathu...Gap athigama achina column and beam size increase agum bro and also depend on floor no's...vara load ah column beam handle paniku....

    • @ashokdavid108
      @ashokdavid108 Před 3 lety +1

      @@civilcognitionintamil8634 sila v2la pathuruken athan keten
      Avanga again center la beam poduvanga
      Load poruthu nama 1st le beam size maximum panikita nalathu

    • @civilcognitionintamil8634
      @civilcognitionintamil8634  Před 3 lety

      Ama bro main beam ah strong ah kudutha pothu ....naduvula beam theyvapadathu........

  • @kannanchinnaiyan4069
    @kannanchinnaiyan4069 Před rokem +1

    Super

  • @Gksen007
    @Gksen007 Před rokem

    Super