Video není dostupné.
Omlouváme se.

Modal analysis using ANSYS Workbench

Sdílet
Vložit
  • čas přidán 15. 05. 2021
  • This video demonstrates how to perform modal analysis using ANSYS workbench 2020 R2 and obtain natural frequencies and mode shapes of the structure.
    Please leave a comment if you have any questions.
    #ANSYS #fem #modalanalysis
    You can download all the files from: github.com/Not...
    Email id: notrealengineering@gmail.com
    "Music: www.bensound.com"

Komentáře • 33

  • @sbd8397
    @sbd8397 Před 3 lety +1

    Thanks for teaching real example for better understand

  • @micahguffey7202
    @micahguffey7202 Před 2 lety +1

    What factors should be considered when choosing the "Max Modes to Find" value?

  • @cesarurra1642
    @cesarurra1642 Před 8 měsíci +1

    WOW

  • @abhishekkumbhar966
    @abhishekkumbhar966 Před měsícem

    Is modal analysis did in Ansys is acceptable? Any acceptance criteria? What is allowable deflection /stress criteria?

  • @huzaifamehmood2966
    @huzaifamehmood2966 Před 4 měsíci

    i have ansys 2024 R1 and ther is not option for beams only assign and you have to chose from a given number of beams which is extensive but it doesn't have options to edit the beams or to change materials

  • @scott337
    @scott337 Před 2 lety +3

    @6:48 After meshing it and clicking onto geometry, it goes back to thin lines and I'm not able to continue by fixing the base. I even restarted the whole thing to try again but it still does it. Any suggestions?

  • @dsaun777
    @dsaun777 Před rokem

    Nice tutorial, well done!

  • @AbdurRahman-sc7ky
    @AbdurRahman-sc7ky Před rokem

    Thanks sir for this project

  • @GANESHNINGWAL
    @GANESHNINGWAL Před 4 měsíci

    Nice this is helpful thanks 😊

  • @vss27
    @vss27 Před 2 lety

    Sir please make a video on rcc frame same as this model .. and can we also do cyclic loading to the frame ?

  • @hairocontreras3374
    @hairocontreras3374 Před rokem

    Excelente video my friend

  • @maxmshensky
    @maxmshensky Před 3 lety

    Thank you my brother 🙏 ❤

  • @kumaraguruvenkatachalam773

    Hello sir, could you please explain the reason behind S bending happening in structure ??

  • @jejeja9
    @jejeja9 Před rokem

    Thanks so much!

  • @JayPatel-09876
    @JayPatel-09876 Před 2 lety

    Which frequency is matching that leads to failure???

  • @danielsarpe8768
    @danielsarpe8768 Před 2 lety

    Can you please help me with the presentation or the video ? thank you in advance

  • @thoufiqthoufiq-rg5it
    @thoufiqthoufiq-rg5it Před 3 lety

    Hi
    I would like to know how load can be withstand

  • @AbdurRahman-sc7ky
    @AbdurRahman-sc7ky Před rokem

    You are rock siiiir

  • @omarch2315
    @omarch2315 Před rokem

    how to change frequency

  • @omkarrevdekar3040
    @omkarrevdekar3040 Před 3 lety

    what is invalid body with zero volume error?

  • @prayagvv3063
    @prayagvv3063 Před 3 lety

    Sir when I was doing Modal analysis on a hollow tower with varying diameter, when clicking solve, it is shown that " Your product license has numerical problem size limits, you have exceeded these problem size limits and the solver cannot proceed ". How do I solve this problem ?

  • @ameyvikramsudarshan7356

    sir Mai aapse ansys sikhna chahta hu kaise aapse contact karu

  • @deepak_nigwal
    @deepak_nigwal Před rokem

    ABSOLUTE BS... 😑 i feel sad for the beginners as they will never know why this is wrong 😓

    • @gayathriperam8124
      @gayathriperam8124 Před rokem

      Could you please mention the wrong things in the above video, thanks beforehand

    • @deepak_nigwal
      @deepak_nigwal Před rokem +1

      ​@@gayathriperam8124 as per this ansys model, the structure is assumed to be having a fully densed and homogeneous rectangular cross-section all the way. On the other hand, the real "civil" structure is much more complex and with non-homogeneous cross-section, containing reinforced concrete and reinforced bars which may also be highly preloaded, thus making it a somewhat composite structure. So the material modelling need to be added accordingly for concrete, bars and beam connections separately. Due to high self weight, the nonlinear regions materials may need to be added (by default the materials are linear), such assumptions are not made at small mechanical component levels.
      Modal analysis is fairly simple and done nicely here, but its also important to understand the underlying physics before solving the actual problem, instead of just learning how to solve the problem. The composite beams would behave differently, the stress paths would be different and preloaded sections would affect eigen vectors and values accordingly and the results would be different than those shown here.
      For civil structures like these, preliminary 2D analysis like this in the video are only useful to start the design in the pre-primary phases, but for complex and accurate modelling, the model needs to be divided into categories, such as, simulation of only metal beams and actual connections (is modelled accurately in IDEA statica) and other simulations like RCC in beams can be modelled in Ansys fairly accurately.
      Finally, its important to correlate the natural freq and its range with real life values. Very tall civil structures have low natural freq, usually lower than 1 hz.

    • @gayathriperam8124
      @gayathriperam8124 Před rokem

      ​@@deepak_nigwalalso could you please give some references to learn this😅, you can take my level as beginner