Siemens S7-1200 series PLC Wiring. English

Sdílet
Vložit
  • čas přidán 14. 05. 2021
  • Siemens S7-1200 series PLC Wiring. For manual, related videos and part numbers please see below.
    Siemens S7-1200 product guide: assets.new.siemens.com/siemen...
    Siemens S7-1200 Systems manual: cache.industry.siemens.com/dl...
    SIMATIC S7-1200 Easy Book: euroec.by/assets/files/siemen...
    Siemens Industry Mall: mall.industry.siemens.com/goo...
    Patreon services: www.patreon.com/igselectronic...
    Website: igselectronics.co.uk/
    eBay store: www.ebay.co.uk/str/igselectro...
    Linked in: / ingus-sudints-1b2a2517a
  • Věda a technologie

Komentáře • 44

  • @kurlenkov
    @kurlenkov Před rokem

    Спасибо, мужик! Немногие на Ютуб рассказывают так подробно о подключении контроллеров

  • @thomaspayne4090
    @thomaspayne4090 Před 2 lety +2

    Pure gold man, thank You !

  • @acvn-hg9gy
    @acvn-hg9gy Před rokem

    my god, this is what i needed. i'm developing a automatic themperature controll unit, 17x AI 16x AO 18x DI and 2x DO. we have some s7-1200's already so thats what i was given to learn with. just found your video on the RTD cards, which helps a LOT. they'll go through a remote IO cabinet connected via profibus. i guess i'll need some AO units to give 4-20mA to the heaters. i'm way to exited to get this going haha

  • @draganmartinovic2734
    @draganmartinovic2734 Před 3 lety +2

    Great video,thank you !

  • @1mSharkster
    @1mSharkster Před 3 lety

    Great video - thanks!

  • @nightking9615
    @nightking9615 Před 2 lety +1

    Its an amazing explanation!
    It would be great if you make a detailed video about wiring the outputs, for the same 1212 PLC.
    As I find it a bit mysterious + there is a lack of this kind of videos about how to wire outputs in PLC 1212.
    Cheers!

    • @IGSElectronics
      @IGSElectronics  Před 2 lety +1

      Will look in to that in to future. Thank you for watching.

  • @real_altairaep249
    @real_altairaep249 Před 7 měsíci

    thank you

  • @Minute80
    @Minute80 Před rokem

    thanks .... 💙

  • @mujamilinchal1294
    @mujamilinchal1294 Před 3 lety

    Nice video

  • @8481393
    @8481393 Před 3 lety +2

    Nice vídeo ,well explained.

  • @juliocesardealmeida2167

    Great! Congratulations!!

    • @IGSElectronics
      @IGSElectronics  Před 3 lety +1

      Thank you!!

    • @juliocesardealmeida2167
      @juliocesardealmeida2167 Před 3 lety

      @@IGSElectronics good morning! I'd like to know about CB 1241 RS-485. I need to know! Thanks a Lot, sir!

    • @juliocesardealmeida2167
      @juliocesardealmeida2167 Před 3 lety

      @@IGSElectronics 6ES7 241-1CH30-1XB0 S C-J3MM1393 2017.

    • @IGSElectronics
      @IGSElectronics  Před 3 lety +1

      @@juliocesardealmeida2167 everything in due course my friend. Rs485 communication video is coming, it will be used to communicate with drives.

    • @juliocesardealmeida2167
      @juliocesardealmeida2167 Před 3 lety

      @@IGSElectronics fantastic, sir! Thank you!

  • @kilvo888
    @kilvo888 Před 2 lety

    Hi, great video. Can I ask why your run light is orange as I have this problem 🤔

  • @globe5877
    @globe5877 Před rokem

    Thanks for the video , I have a issue that there is a 911ohms resistance across DI signal in an SM1223 and 20.9 V DC voltage is coming back to PLC even if contact not closed . Is there a wire break resistance setting in the PLC or what for the resistance is used . Can you please guide me on other your experience. Thank you in advance .

  • @ansolisju
    @ansolisju Před 3 lety

    Thanks for the video! at 5:22 why did you use that for powering the output? is it for demostration only or that sort of installation comes from a regulation?

    • @IGSElectronics
      @IGSElectronics  Před 3 lety +2

      Hi Nicolas. The wiring for PLC's, there is no regulations but more or less code of practice. Every designer will wire there panel differently as long as general electrical rules are fallowed. How you get to end goal is up to you. I separate my input power supply from output power supply as my personal preference and experience. I have seen thing been done many different ways, but the end goal usually is the same. Hope that answers your question.

    • @ansolisju
      @ansolisju Před 3 lety

      @@IGSElectronics thank you very much for your answer!!

    • @IGSElectronics
      @IGSElectronics  Před 3 lety

      @@ansolisju Your wary welcome.

  • @mortezaabasian1293
    @mortezaabasian1293 Před rokem

    Thank you, but please explain more slowly, I couldn't understand so much, because I'm a foreigner 😄

  • @contentilla8115
    @contentilla8115 Před rokem

    Why there's a switch in right side model it's selector or for any other operation

  • @yeh.samay.bhi.beet.jayega

    @IGSElectronics From the product manual, the technical data of digital input shows that logic 1 signal (min.) : 15 VDC at 2.5 mA and for
    logic 0 signal(max.) : 5 VDC at 1 mA. Does it mean that the CPU will consider input as bit '1' when voltage is higher than or equal to 15 VDC? How the CPU will consider the input as bit '0'? Any value ranging below 15 VDC until 5 VDC would consider as bit '0', is it right? Your answer would help me a lot.
    A signal generator produces 12 VAC square wave signal. Between the source and our PLC, there is a diode which converts it into a DC half wave signal. Certain resistor combinations creates the stepped voltages like 9 V, 6 V and 3 VDC to indicates the different states. This signal is of PWM type and carrying some information. If I step it up beyond 15 VDC to be considered it as logic'1' signal, the new voltage values on the path will give feedback at source side through detection circuit. The source side must detect +9/-12 V, +6/-12 V and +3/-12 V in AC form. As the source signal has the range of +12/-12 VAC and standard values as per IEC protocol must be programmed in controller of source side.
    Any hint or guidance would be highly appreciated.
    Thank you very much for the informative video!!😊

    • @IGSElectronics
      @IGSElectronics  Před rokem

      Hi There. I have not looked in to the manual my self regarding this matter, but for what you are saying, it is min 15v required for input to be considered as 1 and anything below will be considered as 0.

  • @niqolass4
    @niqolass4 Před 2 lety

    In this case of Outputs relay, could you use it with 24 VAC?

  • @aleckcons4983
    @aleckcons4983 Před 11 měsíci

    is that sourcing or sinking?

  • @MXb7R
    @MXb7R Před 2 lety

    Where I can buy those cables connected to inputs and relay outputs? Or how they are called?

    • @IGSElectronics
      @IGSElectronics  Před 2 lety +1

      The cable is called tri rated cable and crimps are called ferrules.

    • @MXb7R
      @MXb7R Před 2 lety

      @@IGSElectronics Which AWG are recommended? and those numbers indicating the addresses how cani search them? Are those cables alreade for sale instead of buying the tri rated cable and ferrules? Thank you so much beforehand

  • @aldotony3765
    @aldotony3765 Před 2 lety

    Doesn't Adding an external card to a CPU while powered ON damage the CPU? Cause I tried adding an RS-485 module while the CPU was powered ON and the CPU failed.

    • @IGSElectronics
      @IGSElectronics  Před 2 lety

      Hi There. What firmware version is you PLC? What module did you plug on to the plc wile it was still live?

    • @aldotony3765
      @aldotony3765 Před 2 lety

      @@IGSElectronics
      CPU 1214 DC/DC/Rly
      Firmware: V4.2
      Module: CB1241 RS485

  • @hammadarif3441
    @hammadarif3441 Před 2 lety

    what is the difference between dc or rly output from plc ?

    • @IGSElectronics
      @IGSElectronics  Před 2 lety

      Relay is classed as switch and different types of voltages and volt free signals can be used. Transistor is limited to only output 24 dc voltage, but it is much faster.

    • @Ramonchen-wn7xj
      @Ramonchen-wn7xj Před 3 měsíci

      @@IGSElectronicsbesides this in fact relay have longer working life

  • @user-eh6uo2rz7o
    @user-eh6uo2rz7o Před 2 měsíci

    дерьмо 👎