Allen Bradley Controllogix Compactlogix Ethernet Connection Studio 5000

Sdílet
Vložit
  • čas přidán 26. 07. 2024
  • How to configure both RsLinx's Ethernet/IP driver and Ethernet devices driver to connect to an Allen Bradley Controllogix or Compactlogix PLC to Studio 5000 or RsLogix 5000. Controllogix Ethernet connection and the Compactlogix ethernet connection is easy once you have your PC's IP address set to match your PLC's IP configuration.
    View our entire Studio 5000 Programming Lessons at twcontrols.com/controllogix-c...
    Items used in this video:
    All the rest of our Automation Supplies twcontrols.com/products
    The above links make these videos possible. Please use them!
    Support these videos while you advance your skills courses.twcontrols.com/
  • Věda a technologie

Komentáře • 66

  • @mussali_a
    @mussali_a Před rokem +3

    Hi, Tim. Thank you very much. I am new to PLC, and really struggled to find my device in Studio 5000 "Who Active". Didn't know about RSlinx before. You saved me a lot of time and effort

    • @TimWilborne
      @TimWilborne  Před rokem +2

      Yes it can trip you up. Glad I could help out.

  • @jackpast
    @jackpast Před 4 lety +4

    Hey Tim, nice video. I worked in manufacturing as an E&I tech for decades at one place. Our engineers must have done all the legwork to get the entire plants PLCs separated by department and machine. As a troubleshooter/programmer all I had to do was navigate to the correct icon on our shared drive and double click. RSLogix would open and as long as the running PLC program matched the file on the share drive, I could just click ‘go online’ and voila I was online and able to do on-the-run program changes/troubleshooting. And all of this was wireless also! Now I have been to other smaller facilities where IP addresses, Boot P, network adapter settings and everything you are going over is my new reality. Learning a lot in the last several years and keep these great videos coming! Thanks!

    • @TimWilborne
      @TimWilborne  Před 4 lety +3

      Yes you had the dream setup. I work with a few plants like that. They can spoil you. Unfortunately it is no the norm.

  • @bartnelissen3871
    @bartnelissen3871 Před 3 lety +2

    Tim... thanks for this video. This is coming from a guy who has dabbled with PLC5's and SLC's... then quite a few years of no PLC action... and I now find myself getting into dabbling with CompactLogix PLCs for some troubleshooting. Still early in the day here, but this was probably the best 10 minutes I'll spend today :)

  • @Nayshjin
    @Nayshjin Před 2 lety +1

    I love the way u say, 'hi this is tim'

    • @TimWilborne
      @TimWilborne  Před 2 lety +1

      Maybe one day I'll come up with a catchy intro :)

  • @usoroekwereessiet4397
    @usoroekwereessiet4397 Před 3 lety +3

    You are doing quite a great job Tim. Well-done!

  • @augustograton8958
    @augustograton8958 Před 4 lety +2

    Thanks from Brazil Tim !!!

    • @TimWilborne
      @TimWilborne  Před 4 lety +1

      You are welcome Augusto. Thanks for watching!

  • @sudhandiramanisundaram4909

    Awesome! Thanks for Sharing !

  • @robertgoldie6409
    @robertgoldie6409 Před rokem +1

    Thank you very much, worked like a charm.

  • @JJRD222
    @JJRD222 Před 3 lety +1

    Effing awesome! Thanks!

  • @jesusmartell6967
    @jesusmartell6967 Před rokem +1

    Great video!

  • @MuhammadSuleman-hd1ig
    @MuhammadSuleman-hd1ig Před 4 lety +1

    Nice, Thank you.

  • @davidpalmer963
    @davidpalmer963 Před 2 lety

    Morning Tim. my Pops says hello . He is from Beckley WVA., and his wife is from Blacksburg VA.

  • @tonyadcock7347
    @tonyadcock7347 Před 2 lety +1

    Very helpful

  • @TheOrly89
    @TheOrly89 Před 2 lety +1

    Thank you

  • @gfdfggghfg2965
    @gfdfggghfg2965 Před 3 lety +1

    Thanks

  • @doughknuts
    @doughknuts Před 2 lety +1

    Hello! I have a question. I am working on a project that has the PLC talking to a C# app. This is a pill bottle labeling system. There is a photoeye that detects the label passing out of the printer. But its only on for a second, the library used a call method. A call will not catch a second on photoeye. Is there a event send realtime that the app can see?

  • @NA-ce1kq
    @NA-ce1kq Před 3 lety +1

    Hi Tim, I'm planning to buy the IP address explorer tool but I want to know if I can I use this to discover the IP address of the controller thru the ethernet switch?

    • @TimWilborne
      @TimWilborne  Před 3 lety +1

      Hi Nilo, you sure can. See application example below.
      www.theautomationstore.com/how-to-discover-ethernet-devices-on-an-unknown-network-using-plc-tools-sim-ipe-ip-explorer/

  • @hermannelson489
    @hermannelson489 Před 3 měsíci +1

    Thanks . Please what to do if we local network (192.168.1.XX)used on the Ethernet card and we have a plant network (10.4.49.XX). Trying to connect but I can’t with rslinx

    • @TimWilborne
      @TimWilborne  Před 3 měsíci +2

      Here is a video to help you out.
      czcams.com/users/liveW7Q5ZgvEWiw?feature=share

  • @joebilby1007
    @joebilby1007 Před 2 lety +1

    Hey Tim,
    I do not have an Ethernet port on my laptop, only USB. Is there a USB to Ethernet cable that will allow me to connect to Studio 5000?

    • @TimWilborne
      @TimWilborne  Před 2 lety +1

      Hi Joe, this is the one I use. www.amazon.com/gp/product/B00MYT481C/ref=as_li_qf_asin_il_tl?ie=UTF8&tag=twcontrols-20&creative=9325&linkCode=as2&creativeASIN=B00MYT481C&linkId=5011467e1bb66c1750d72c0b0bfba08c

  • @nora_adora
    @nora_adora Před 3 lety +1

    Hey Tim,
    How can you assign the IP Address from a brand new CompactLogix out of the box without the little tool you used?
    Thank you

  • @craigquary4017
    @craigquary4017 Před rokem +1

    I recently got a new computer and when I transferred my Rockwell license from my old computer to new I had to go to Rockwell site and get latest versions of the tools I need to do my job. Needless to say Rockwell does net vend or support RSLogix 5000 anymore and makes you upgrade to Studio 5000. When I downloaded the studio 5000 and factory talk I was also expecting RSLinx classic but they have stopped this as well. Apperently you conect using studio 5000 now and it is slightly confusing for me mainly because the procsess has changed.

    • @TimWilborne
      @TimWilborne  Před rokem +2

      See if this helps Craig
      czcams.com/video/pkyATqf_bSg/video.html

  • @ivanblazhenko99
    @ivanblazhenko99 Před 3 lety +1

    Hi, Tim.
    I have a question that stuck in my head and I still didn't get answer yet)
    Is is possible to send data using MSG from ControlLogix Emulate to Micrologix1100 Emulate throught Channel 0 using COM-0-COM Emulator?
    What I did:
    1. Set up two drivers in RsLinx (for Virtual backplane and SLC)
    2. In each Emulate configured Channel 0 and assigned COM ports
    3. In Studio5000 built program using MSG
    4. Picked "SLC typed write", assigned tag for source element like INT or Dint (16 and 32 bits respectively)
    5. Assigned the destination element like N9:0 or L10:0 .
    My MSG instruction is executing and I see flashing Done bit ( i did MSG through TON) but nothing in Rslogix500 data file.

    • @TimWilborne
      @TimWilborne  Před 3 lety +1

      Hi Ivan, I haven't worked enough with Emulate to know. But hit the basics first, make sure the error bit isn't being set and there is no error value. These would clear the next time you enable your message.

  • @ajmalaja9888
    @ajmalaja9888 Před 11 měsíci +1

    Hello sir...how to communicate Allen brandly(compactlogix) to other plc like omran? Would you upload these related details?

    • @TimWilborne
      @TimWilborne  Před 11 měsíci +1

      I am not that familiar with Omron but I would look to see if it supports Modbus TCP or Ethernet /IP, those would be the easiest ways.

    • @ajmalaja9888
      @ajmalaja9888 Před 11 měsíci +1

      @@TimWilborne ok thank you sir. But one more thing did you uploaded about the communicate between allen brandly and any other PLC through Modbus TCP or Ethernet /IP,

    • @TimWilborne
      @TimWilborne  Před 11 měsíci +1

      Yes, this playlist has Modbus communications for the Controllogix/Compactlogix PLC in Studio 5000 and the Micro800 PLC in Connected Components Workbench.
      czcams.com/play/PLUi5cdVq3wTCNyXp_W496Z-td2RPm3nES.html

    • @ajmalaja9888
      @ajmalaja9888 Před 11 měsíci +1

      okay thank you sir@@TimWilborne

  • @adriansilaghi6058
    @adriansilaghi6058 Před 4 lety +1

    Can a micrologix1100 controller be connected through wireless internet?

    • @TimWilborne
      @TimWilborne  Před 4 lety +2

      Sure, but it depends on what you want to do with it over the internet as to whether it will work. There are lots of different options out there for this.

  • @mrugeshmistry9224
    @mrugeshmistry9224 Před 4 lety +1

    Can you upload Videos for Pulse Output Video in Delta PLC?

    • @TimWilborne
      @TimWilborne  Před 4 lety +2

      Hi Mrugesh. I don't have much experience with Delta PLCs but we do have some PWM videos coming on AB.

    • @mrugeshmistry9224
      @mrugeshmistry9224 Před 4 lety +1

      @@TimWilborne
      Thanks for Reply.

  • @suriyat8773
    @suriyat8773 Před 10 měsíci +1

    Plc model?

    • @TimWilborne
      @TimWilborne  Před 10 měsíci +1

      This video works with all Allen Bradley Controllogix and Compactlogix PLCs.

  • @Maintenance_Mark
    @Maintenance_Mark Před 2 lety

    I did everything in your video and it all worked except once I'm done I still cannot connect to my PLC it does not show up in RS who

    • @TimWilborne
      @TimWilborne  Před 2 lety

      Make sure you are pinging the PLC and getting replies.

    • @Maintenance_Mark
      @Maintenance_Mark Před 2 lety

      @@TimWilborne I'm not. I've watched multiple of your videos and done what you show but for whatever reason it's not letting me set the IP address of the plc. When I set the PLC address in boot p it allows me to do it but when I ping that address I don't get a response. I've tried using a USB cable but it says it's not compatible or can't find drivers.
      I went into my laptops network settings and manually set the IP like you said. Then I assign a IP with the first two sets of numbers the same to the plc then I try pinging it but it just isn't working. I'm starting to think I have a incompatibility issue with my laptop or something.

    • @Maintenance_Mark
      @Maintenance_Mark Před 2 lety

      @@TimWilborne is it possible that the PLC already has an IP address but I'm just not able to see it or find it? Would that stop me from being able to set the IP in bootp?

  • @davidpalmer963
    @davidpalmer963 Před 2 lety

    Tim ..PLC Automation Technician
    David Palmer here. How are you?
    Can I dowload Rslogix 5.?

    • @TimWilborne
      @TimWilborne  Před 2 lety

      You have to purchase a license or it is an option in some of the Studio 5000 bundles. Do you just "want" RsLogix 5 or do you have an actual NEED for it?

    • @davidpalmer963
      @davidpalmer963 Před 2 lety

      @@TimWilborne
      No I need... we have 4 automated de- palletizers. All with 1771/A1-B PLC.

    • @TimWilborne
      @TimWilborne  Před 2 lety

      @@davidpalmer963 I would reach out to your local Rockwell distributor. It won't be cheap so they can help you find the most economical option.
      locator.rockwellautomation.com/

    • @davidpalmer963
      @davidpalmer963 Před 2 lety

      O.k. cool. We have license for 500 and. 5k. We mostly use 7 slot SLC 500.