  • It is very common for a stop tap or an outside tap to start leaking from the gland nut, this can easily be repaired using an adjustable spanner, and some PTFE tape or string and silicone grease.
  • Jak na to + styl

Komentáře • 223

  • @neil6477
    @neil6477 Před 2 lety +4

    Thank you SO much for this. As a non-plummer I had put up with our garden tap leaking out of the top for a couple of years. Today, I went and gave the nut a small twist and - bingo - no more leaking. Can't believe it. I actually laughed out load! Again, thank you!

    • @ultimatehandyman
      @ultimatehandyman  Před 2 lety

      Glad it helped! 👍

    • @MartynDews
      @MartynDews Před 2 lety

      Same here Neil. Leaky internal stop cock led me to this video which showed me how to fix. Then, I thought I'd have a go at the outside tap as that has been leaking from the gland for as long as I can remember. 10 minutes later, re-packed and no leaks!!

  • @r1273m
    @r1273m Před 3 lety +3

    Thank you for that, saved me clambering about under the sink to find the outside tap isolating valve. I didn't realise you could do the job with the water on! Great video.

  • @coxyofnewp
    @coxyofnewp Před rokem

    7 years ago. This video and your fast reply to a comment made on your "How to change a stop tap washer" video sorted my mothers tap.. And now I watched it again to do an old tap in my house - Perfect again !! Your vids have help me out so many times, for many things .. many thanks and keep up the great content !!

  • @DarrenGulliver
    @DarrenGulliver Před 8 lety +2

    A job that I have been putting of for some months now. Turned out the gland nut just needed tightening. Added to favorites for future. Thank You for this video. Ultimate Handyman has saved my day (and pockets) again :)

  • @emmbrook1
    @emmbrook1 Před 9 lety +2

    Excellent, thank you. What I thought would be an expensive plumbing job took 20 seconds to do! Clear and easy to understand.

  • @BeardyRebel
    @BeardyRebel Před 11 lety +9

    Excellent, excellent, excellent video!!!
    Most things are possible once you have the know-how but that's only possible when there are people like you who are prepared to take the time to share your knowledge. So much easier to follow than it would be from a book.
    Many thanks!

  • @mydiytutor
    @mydiytutor Před 3 lety +2

    Thank you so much for this quick DIY trick. You have saved me time and money from replacing the whole cartridge/valve or having to hire a plumber to change a new stopcock. It really works. Lucky for me, tightening it solved mine, didn't have to open it up and add PTFE.

  • @bowsermcdonald5165
    @bowsermcdonald5165 Před 3 lety +1

    I thought if I unscrew the top nut it would spray out so wouldn't have dare try it but after watching this I had it fixed in 5 mins, thanks mate great video 👍

  • @DJunclepaul2nd
    @DJunclepaul2nd Před 3 lety

    Mentioning about not having to isolate the tap, but to have it switched off, is valuable info not many mention. Thanks for this video

  • @timthorpe81
    @timthorpe81 Před 4 lety +3

    Very clear and easy to follow! Thank you so much for making this available. Probably saved me quite a bit of money getting a plumber out

  • @disconeil
    @disconeil Před 11 lety +3

    Thanks alot UH, I never even realised that my tap was leaking until I watched this video! Thanks for the comprehensive guide mate, another job done and more brownie points for yours truly.
    Cheers. N.

  • @Mirpuria
    @Mirpuria Před 8 lety +2

    Best DIY tutorial channel online! Thank you for your helpful videos.

  • @upendrapandya2107
    @upendrapandya2107 Před 10 lety +5

    Thank you very much, it was very useful to know that I could do this without isolating water supply.

  • @Feelthatbass
    @Feelthatbass Před rokem

    This video was exactly what I needed to stop my leaky tap! Always thought it was gonna be a horrible job. It took longer for me to find my spanner than to do the actual work!

    • @ultimatehandyman
      @ultimatehandyman  Před rokem

      I’m glad you found the video useful
      Thanks for the comment 👍

    • @thispersonrighthere9024
      @thispersonrighthere9024 Před 5 měsíci

      ​@@ultimatehandyman THANK YOU SO MUCH!
      for _years,_ i've been wondering if the gland was different from the bonnet, but thanks to your amazing video, i see now that the gland is just part of the bonnet!
      could you also please tell me why they sometimes call it "gland *bushing"* instead of just gland? like, what's the point of mentioning the word "bushing"?

  • @weekendwarriorpodcastsouth6179

    Brilliant, thanks for this you just saved me a plumbers callout and endless frustration 18pm on a Sunday evening.
    Cheers from South aafrica

  • @Taqqiyastar
    @Taqqiyastar Před 10 lety +1

    Thank you for sharing your experience and knowledge. You have helped me in my heating engineering course work.
    Thank you for being helpful in details professionally explained

  • @marstonpwilderx4356
    @marstonpwilderx4356 Před 6 lety

    I just wanted to say a big thanks, your excellent videos have been such life savers and saved me time and money.

  • @ColGrenfell
    @ColGrenfell Před 9 lety

    Many thanks, great video, great advice, saved me the cost of calling a plumber at 10pm when the old seal failed completely! Thankfully had some PTFE tape to hand. Thanks again

    • @ultimatehandyman
      @ultimatehandyman  Před 9 lety

      Colin Grenfell
      I'm glad the video helped ;-)
      Thanks for the comment

  • @graycleary
    @graycleary Před 8 lety

    Thank you for this. Mine is now sorted. Great job and keep up the good work.

  • @leftytottenhamboy
    @leftytottenhamboy Před 9 lety

    How clear and simple was that? You saved my bacon. I didn't know it was leaking till I tiled the kitchen floor, and thought I would have to wait for a plumber to fix it. Great work, thanks.

  • @ianb9729
    @ianb9729 Před 8 lety +1

    Thank you for the "first thing you should try to do..."! It's a horrible old tap and I re-packed it when we moved in a couple of years ago. I should have thought of just tightening the nut myself, but in the moment when I was saying things like "Oh bother, that tap is leaking again" I wasn't really thinking anything except technical terms of four letters!

  • @matthewgotts1
    @matthewgotts1 Před 9 lety +1

    Great vid thanks, was able to confirm my suspicions where my stop tap was leaking and fix, rather than waiting 24 hours for a repairman to come out. Had to turn the water off at the meter though, as tap handle screw was corroded so had to open stop tap fully to give enough spindle to slide gland nut up. 2 turns of PTFE tape and job done! Thanks for posting.

  • @petebanham3742
    @petebanham3742 Před 5 měsíci

    Old vid i know but still relevant and helpful. My main stopcock started leaking after I had to turn the water off to change a tap and nipping up the flange didn't help. Would never of thought that I could take it apart with the water still on. Took 4 lots of PTFE tape but leak currently stopped. Thanks again

  • @johnfharvey
    @johnfharvey Před 4 lety +4

    Brilliant, thank you, solved my leaking stop tap beautifully. Great advice and demo.👍

    • @ultimatehandyman
      @ultimatehandyman  Před 4 lety

      I'm glad the video helped
      Thanks for the comment 👍

    • @radishpea6615
      @radishpea6615 Před rokem

      Glad you posted as I did wonder if PTFE tape around the shaft would work

  • @S2GilesB
    @S2GilesB Před 7 lety

    Thanks, very useful, been leaking for ages, repacked with PTFE tape that I already had & its now nice and tight

  • @PBayee34
    @PBayee34 Před 4 lety

    Your videos are so useful & easy to understand, some other great plumbing videos out there but yours are always the best.

  • @jwong19
    @jwong19 Před 11 lety

    Another great and handy tip...thanks for sharing it. Well done!

  • @sbridgett0
    @sbridgett0 Před 10 lety

    Thank you, just tried this method on a leaking stop tap and it's stopped the leak. Thank you.

  • @MAhmd1460
    @MAhmd1460 Před 3 lety

    Thank you very much for this valuable video. We’ve been in trouble for so may days and the fix was only couple of minutes job. Much appreciated

  • @detoxzero01
    @detoxzero01 Před 10 lety

    Wow....Excellent tip, I have the same problem and thought that I had to replace the whole tap. Many thanks.

  • @edcurant
    @edcurant Před 11 lety

    great tip and very helpfull,looking forward to more of these

  • @AnnTickwitty
    @AnnTickwitty Před 6 lety

    I was prepared for a half day job but thanks to your video it took 5 minutes tops!

  • @suebance9625
    @suebance9625 Před 5 lety +1

    As a woman with not one ,but two ,leaky garden tap' s & absolutely no knowledge of pluming I can not wait to try out your helpful information , in the hope I will also be able to save money by not having to call a plumber !

    • @ultimatehandyman
      @ultimatehandyman  Před 5 lety

      I've done this plenty of times ;-)
      Good luck with both of them

    • @suebance9625
      @suebance9625 Před 5 lety

      Ultimate Handyman worked a treat , thank you. !!!

  • @johngriffiths9521
    @johngriffiths9521 Před 2 lety

    Again, very well explained and demonstrated. Thank you.

  • @squidmuttly
    @squidmuttly Před 3 lety

    Thank you, this was very clear and informative. Perfect teaching!

  • @EliteHydronics.
    @EliteHydronics. Před 6 lety

    i've always found a well siliconed greased o-ring works a treat :) great vid

  • @steverushaw8761
    @steverushaw8761 Před 5 lety

    worked a treat for me saved me buying a new Tap..Many thanks

  • @IndianHinduUK
    @IndianHinduUK Před rokem

    Great tip to stop leaking valve. Helped me fix leak rather left overnight

  • @gill834
    @gill834 Před 7 lety

    Thanks for the advice,i fixed my outdoor tap in the way you showed,regards Paul.

  • @FACTS_WORLD70
    @FACTS_WORLD70 Před rokem

    I like all the steps you covered.... Jazakalah.... May Allah reward u

  • @francodiroma
    @francodiroma Před 8 lety

    Brilliant. Saved me a trip to Screwfix. Thx Frank

  • @davewatkinson4484
    @davewatkinson4484 Před rokem

    Cool video. Tighten saved a load of messing, nice one.

  • @gmmooseblaster
    @gmmooseblaster Před 5 lety

    Another excellent, no nonsense instructional video.

  • @geniegenie2453
    @geniegenie2453 Před 2 lety

    Fabulous, 1/8th turn on the nut and leak gone! Thanks.

  • @MartynDews
    @MartynDews Před 2 lety

    Excellent video. Just what I needed to explain how to solve the leaking stop cock. Thanks for taking the time to upload. I thought I would have needed to turn off at the street stop cock to re-pack but your video explained that I would not end up flooded when removing the gland nut. Good job as I did look at the street stop cock and after removing all the debris to find the tap, there was no way in a million years that was turning! That's the next job. I guess that's a water board job.

    • @ultimatehandyman
      @ultimatehandyman  Před 2 lety +1

      I recently did a job at the brother-in-laws, when a plastic pipe fitting sheared. I repaired the pipe using a UTC czcams.com/video/_k5NS5Y-KHg/video.html
      He turned off the stop tap in the street, but it was passing. He phoned the utility company, and they just told him to use a pipe squeeze off tool, or freeze kit!
      I guess it is different if the stop tap is seized, as they have to provide a means of isolation, although they still might argue!
      Thanks for the comment 👍

    • @MartynDews
      @MartynDews Před 2 lety

      @@ultimatehandyman Just has this reply from UU. Seems external stop tap are no longer maintained or fitted to new properties I was told.
      I can advise as a company we do not maintain or install external stop taps anymore, as they don't serve the company a purpose. By Law all properties must have an internal stop tap fitted in case of emergencies, if yours has seized we would recommend contacting a WIAP's approved plumber to repair this for you.
      These plumbers can carry out any private work or repairs that need to be undertaken using alternative methods, like freeze or squeeze, to shut off a supply. This meaning there would be no need for use of an external stop tap. In cases where these alternative methods have been attempted but can't be used we can look into raising a turn off/on appointment for our engineers to attend to assist where we can.
      If you would prefer to have an external stop tap for your peace of mind then you can have one fitted within your boundary by an approved plumber.

    • @ultimatehandyman
      @ultimatehandyman  Před 2 lety

      @@MartynDews Looks like they have passed the buck to the householder 😱

    • @MartynDews
      @MartynDews Před 2 lety

      @@ultimatehandyman That's what I thought. I was told by the agent at UU that that stop taps were originally put in so that supply could be cut for non payment, (not sure how true that is) and that new builds don't have external stop taps, (again, I can't verify that). I did ask what would I do is in the unlikely situation there was an escape of water from or on the external side of my stop tap and they said they would respond to an urgent water escape call to come and turn it off in the street. Which doesn't make sense. Better to sort it now in my view.
      I best get a freeze kit handy just in case!

    • @ultimatehandyman
      @ultimatehandyman  Před 2 lety

      @@MartynDews A pipe squeeze off tool might be better (if there is exposed plastic pipe), as many freezing kits won't work on mains pressure water, even the ones that do work on mains pressure water will only work, if the water is static, so in the event of a burst pipe they will not work.
      czcams.com/video/AMlZecaSfTY/video.html&t

  • @user-ed5mh3hb4h
    @user-ed5mh3hb4h Před 11 měsíci

    Thanks so much, excellent video, so helpful

  • @mtozden
    @mtozden Před 11 lety

    thanks for useful and educative videos. great.. i liked your works..

  • @zanderman004
    @zanderman004 Před 5 lety

    Cheers, mate! "The first thing you should try..." (tightening the nut..) worked.. I've just been pissing about with putty and making a real mess to no avail.. saw this video, tightened that and bam.. stopped.. Thanks. 👍😅

  • @KingofDundee
    @KingofDundee Před 4 lety

    Very well explained, thank you Ultimate Handyman!

  • @paul1962uk
    @paul1962uk Před 11 lety

    Wow ty for speedy reply!!

  • @earthpotato5143
    @earthpotato5143 Před 3 lety

    Thank you, this video helped me fixed the leak in my home.

  • @corumuk67
    @corumuk67 Před 8 lety

    Thanks, very handy demonstration.

    • @ultimatehandyman
      @ultimatehandyman  Před 8 lety

      +Corum Jhaelen Irsei
      You are welcome ;-)
      Thanks for the comment

  • @markslade9722
    @markslade9722 Před 5 lety

    Nice one mate, had this same problem on the stop cock for the mains coming into my house, was going to buy a new stop cock for £3-50, then have to isolate the mains outside at my water meter to allow me to fit it, but saw your video, tightening did not work for me, so used p.t.f.e tape, job done, dry as a bone now saving me a few quid and time, thanks.

    • @ultimatehandyman
      @ultimatehandyman  Před 5 lety

      You are welcome, I'm glad the video helped ;-)
      Thanks for the comment

  • @calumscott.1442
    @calumscott.1442 Před 6 lety

    Thanks for a great video.

  • @radishpea6615
    @radishpea6615 Před rokem

    If this works a big thank you. Not a method I would have thought of using. I was thinking of trying to replace what ever the original seal is that leaks

  • @HughSykesFilm
    @HughSykesFilm Před 5 lety

    Brilliant. Thank you. Stopped mains stop-tap slow drip just by tightening. If it starts to drip again, then PTFE. But so far so......no drip.

  • @1NatashaLouise
    @1NatashaLouise Před 9 lety

    I've watched this 6 times, replaying the bit where you explain that you don't have to go mad tightening up the gland nut. I'm still laughing! I can do that now. Thank you, I thought you were great.

  • @swelihlenzama7303
    @swelihlenzama7303 Před rokem

    The video was si helpfull. I've tightened the tap and it stopped leaking

  • @EdBonds
    @EdBonds Před 7 lety

    Brilliant -worked for me!

  • @GALLEN-vf7uy
    @GALLEN-vf7uy Před 8 lety

    Very helpful...Thanks

  • @bsales3101
    @bsales3101 Před rokem

    Good clear video. 💪👌

  • @sarangapany3508
    @sarangapany3508 Před rokem

    Thank you very much for the information.

  • @josht8288
    @josht8288 Před 9 lety +9

    I always twist my ptfe into a rope to do this and I only have to do it once not 3 times.

  • @nigelcnash
    @nigelcnash Před 7 lety

    Brilliant! Many thanks.

  • @paul1962uk
    @paul1962uk Před 11 lety

    If i isolate the water to the bib tap can i put tha ptfe on in the open position as the screw on the tap handle has corroded an doesn't want to come off, it would give me a bit more room to put the ptfe on.

  • @bobbywhite350
    @bobbywhite350 Před 9 lety

    Really useful, thanks.

  • @davidworsley7969
    @davidworsley7969 Před 10 lety +3

    I served my time as a plumber in the 60s-we used to carry a hank of hemp and a tobacco tin of tallow- what you are doing is re-packing the stuffing box but no doubt some would find this (correct) term offensive nowadays.The same technique is of course applicable to most taps,I still think untwisted string and tallow/lard far superior to PTFE when fitting an outside tap as it allows more flexibility when adjusting the tap to the correct 90 degree angle.Try doing it in an unlit outside lav in the dark-happy days!.

  • @TheBanksHouse
    @TheBanksHouse Před 3 lety

    Thanks so much very helpful

  • @exwhyz33
    @exwhyz33 Před 10 lety

    Thank you. V helpful.

  • @NatFacker
    @NatFacker Před 3 lety

    Thank you. Clear instructions as always. Problem solved in a jiffy.

  • @koncsaj
    @koncsaj Před rokem

    Brilliant explanation

  • @davemarch1811
    @davemarch1811 Před 2 lety

    Great video thanks

  • @sammysatsangi7754
    @sammysatsangi7754 Před 5 lety

    very helpful video . thanks

  • @daywalkersales1174
    @daywalkersales1174 Před 2 lety

    this was amazing thank u

  • @mattbower4725
    @mattbower4725 Před 3 lety +2

    When fitting an outside union tap you have to rotate it backwards so that it ends pointing vertically down. Therefore, not just a watertight seal is required, but also to lock the tap in position, which PTFE doesn’t do. After research, it seems Loctite 577 is highly regarded. However, the cost is prohibitive to someone who would not use it a lot (approx £25 for 50ml), but also not available at Screwfix/|Toolstation.
    Can any plumbers recommend a cheaper alternative?

    • @ultimatehandyman
      @ultimatehandyman  Před 3 lety +1

      If the tap is not facing downwards, unscrew it and add a lot more PTFE tape, then use a long spanner to tighten it, so that it tightens up facing in the exact right position. You do not need anything fancy- just PTFE tape ;-)

  • @mohammedal-tameemi9881
    @mohammedal-tameemi9881 Před 11 lety

    very nice sir

  • @gordondaniels96
    @gordondaniels96 Před 3 lety

    thanks for the info

  • @ImJustAsBad
    @ImJustAsBad Před 11 lety

    wow, you make is look so easy to do. I know if I try I will royal screw it up or down, your choice ;)

  • @robertfay1150
    @robertfay1150 Před 4 lety

    It worked! Thanks

  • @ThinFreddysFlop
    @ThinFreddysFlop Před rokem

    Hi there, thanks for the video. I have a tap which is leaking out the top but doesn't have a packing gland. Wondering how I can fix that type of tap?

  • @jamesdouglas8889
    @jamesdouglas8889 Před 4 lety

    great thank you. mine fixed

  • @davidmachin1710
    @davidmachin1710 Před 4 lety

    Great videos tutorials and advice..thank you Sir. I have a 3/4 brass stopcock under my sink which is the feed/supply for the house which has been in about 40 years and is now reluctant to turn either way...can I still buy a replacement head for this unit please which I think would be the easiest option. Thank you.

    • @ultimatehandyman
      @ultimatehandyman  Před 4 lety

      It's impossible to say, you would just have to get one and see if it fits, I'm afraid. The chances are that they are not quite the same 40 years down the line. Obviously you will have to isolate the water at the outside stop tap before attempting it ;-)
      Thanks for the comment 👍

  • @benny5825
    @benny5825 Před 11 lety

    can you do a video on arc welding setting up etc even if you cannot show the weld in progress cheers.

  • @dayahnadya4647
    @dayahnadya4647 Před 4 lety

    Thank you,my kids love it,my brother like it,my family happy with it..also my frends and hometown remember it..😀👍👍👍

  • @69kesh
    @69kesh Před 4 lety

    thank you

  • @davidmachin1710
    @davidmachin1710 Před 4 lety

    Thank you Sir

  • @Moultonist
    @Moultonist Před 5 lety

    I've been changing the washer on a basin tap but now I have a problem. I can't screw the gland nut back into the tap mechanism. The threads just will not 'bite'. I really push hard on the gland nut whilst trying to get the threads to bite but just can't do it. There's a small O ring and a thick hard rubber washer in the mechanism. The tap's not dripping any more from the spout but it leaks from the gland nut when I turn the tap on. Can you offer advice how to solve my problem? Thanks

    • @ultimatehandyman
      @ultimatehandyman  Před 5 lety

      Does this help-
      www.ultimatehandyman.co.uk/how-to/taps/tap-head-gear

  • @pppscooby
    @pppscooby Před 10 lety

    Hi how do i repair a garden tap which doesnt close shut but just goes slightly tight and if you try tightening it more it just spins open. Like the threads are slipping

    • @ultimatehandyman
      @ultimatehandyman  Před 10 lety

      It sounds like the head gear is damaged. Replacement of the tap might be the only option, although on some you can just replace the head gear. I'll make a video of this when I get chance ;-)

    • @anthony342
      @anthony342 Před 9 lety

      thread inside the tap has worn mate .. seen it many times with the crappy brass they use nowadays needs new tap

  • @factsnetworks6205
    @factsnetworks6205 Před 3 lety

    Work done

  • @TOOLMFR
    @TOOLMFR Před 9 lety

    Step one: Try tightening .... and voila my leak is gone... thanks for helping me not to over look the simplest answer

    • @ultimatehandyman
      @ultimatehandyman  Před 9 lety

      Terry Davis
      I'm glad the video helped ;-)
      Thanks for the comment

  • @terrycunnane5443
    @terrycunnane5443 Před 2 lety

    Great!

  • @cytodexcultispher4757
    @cytodexcultispher4757 Před 9 lety

    my shutoff valve doesn't seem to have the gland nut and water is leaking through the stem now. Any ideas?

    • @ultimatehandyman
      @ultimatehandyman  Před 9 lety

      Not sure, sorry.
      If you could post a picture of it here one of the plumbers might be able to advise-
      www.ultimatehandyman.co.uk/forum1/plumbing-forum-f8.html
      It's free to join BTW.

  • @LeeHouston
    @LeeHouston Před 8 lety

    Cheers pal.

  • @stroketheboat
    @stroketheboat Před rokem

    My problem is that I can’t turn the tap off. The only way I can stop water coming from the tap nozzle (not under the packing gland itself) is to use a wrench to over tighten.
    Any ideas?

    • @ultimatehandyman
      @ultimatehandyman  Před rokem

      It sounds like the washer might be damaged. If you can isolate the water supply elsewhere, they are normally easy to replace- czcams.com/video/XAPnepUbWvE/video.html&pp

  • @markcumbriauk
    @markcumbriauk Před 8 lety

    Great vid mate, You sound like you have a Bolton accent : )

  • @kaiser9100
    @kaiser9100 Před 11 lety

    I find loctite-55 works great on jobs like this.

  • @AaronBrown8219
    @AaronBrown8219 Před 4 lety

    What if it leaks from the outlet and no matter how hard I try to close the tap it still drips out? Packing gland not leaking just the outlet

    • @ultimatehandyman
      @ultimatehandyman  Před 4 lety

      You need to replace the washer, but you will have to isolate the water first. I have done a video on a stop tap, which is the same process- czcams.com/video/XAPnepUbWvE/video.html
      Thanks for the comment 👍

  • @AJ_Lucas
    @AJ_Lucas Před rokem

    What do you do if the screw holding the tap on is corroded and rounded off?

    • @ultimatehandyman
      @ultimatehandyman  Před rokem

      You can re-pack the gland with the handle on, but it is more difficult 👍
      It is possible to drill the head off the screw, but it’s not easy to do.
      Some techniques here might help- czcams.com/video/_mTFQbaT3Zc/video.html&t

    • @AJ_Lucas
      @AJ_Lucas Před rokem

      @@ultimatehandyman I was able to just wrap the PTFE tape below the packing nut. Really good of you to reply -- appreciate that, sir.

  • @Keeping_IT_Simple
    @Keeping_IT_Simple Před 3 lety

    Strangely enough this video just came up on my recommendation feed ...
    I just fixed a leaky stop tap earlier today using this method ....
    What is your view on eventually replacing my stop taps with Lever ball valves as I've been told they are less likely to leak over time . The stop Taps in my home seem to need fixing every few years or so ....

    • @ultimatehandyman
      @ultimatehandyman  Před 3 lety +1

      I'm not sure about the lever stop valves. If they go wrong you need to remove the whole valve to service it, whereas a stopcock can be serviced without removing the whole valve ( you can change the washer or replace the packing gland). I'm sure many people have fitted them as well as the stopcock though.

    • @Keeping_IT_Simple
      @Keeping_IT_Simple Před 3 lety

      @@ultimatehandymanReally appreciate you taking the time to answer me.
      Guess i'll just keep on with the running repairs for the foreseeable future?

    • @ultimatehandyman
      @ultimatehandyman  Před 3 lety +1

      @@Keeping_IT_Simple What you can do, is isolate the water in the street, drain down the system. Buy a new stop tap and just swap the head gear over (large nut in the middle of the stop tap), this replaces the washer, packing gland, spindle, handle etc. Most stop taps are made to the same standard, so many of the parts are interchangeable (not all). Or before trying that, you could try repacking the gland using some string and silicone grease that is suitable for use on potable water.
      I think the packing gland is normally made from graphite (the ones I have seen have been), In fact, I have just found these- www.bathroomspareparts.co.uk/15mm--12-stuffing-box-gland-for-stopcock--tap-price-each--eb10023-15578-p.asp

    • @Keeping_IT_Simple
      @Keeping_IT_Simple Před 3 lety

      @@ultimatehandyman Wow amazingly helpful & supportive of You Sir!! And on a video that you published 7 years ago too!!
      if this is the sort of level of service You give, it's a shame You are not nearer to me or I would just get You in to sort out my plumbing in person!
      I think the next time it starts dripping ( usually 2 - 3 years ) I shall just replace it. Luckily as its on the feed to my header tank I can isolate it internally to the flat so should not be too difficult ( famous last words anyone?)
      Thanks Again
      Take Care

  • @telosfd
    @telosfd Před 7 lety

    Nice job. Why don't use a spherical type of tap?

    • @ultimatehandyman
      @ultimatehandyman  Před 7 lety +1

      Do you mean a ball valve?
      If so they are not often used in the UK for water isolation purposes, the Utility companies etc. all seem to use a traditional type of stop tap like the one in this video.