Plumbing Laundry Rough - in (move to different place)🧺🧼

Sdílet
Vložit
  • čas přidán 30. 09. 2020
  • • RU101 - AMERICAN STAND...
    Washing machine box
    2" pvc pipe
    1-1/2 pvc pipe for vent
    T- 3x2"
    1/2 cpvc water pipe
    • KOHLER 8304 - KS - NA ...

Komentáře • 77

  • @jorgenorman8715
    @jorgenorman8715 Před měsícem

    so I have a two story townhouse and I want to add the washing machine standpipe on the 1st floor to the 2nd floor bathroom’s 3 in stack, can I add a 1st floor washing machine standpipe to that same stack with a 3x3x2 tee. And should I also run a vent like you did?

  • @heemanchalmaharaj6709
    @heemanchalmaharaj6709 Před rokem +17

    This little czcams.com/users/postUgkxVoi3B4CB6Oygq1-vo4OTL1M_M5JkrXif tub works perfect in our 6 x 6 shower and is easy to get in and out. Also easy to drain.

  • @ncooty
    @ncooty Před 6 měsíci +2

    Can't put a tee horizontal. I know you probably think it's just for venting, but everything lower than 6" above the flood level of the vented fixture must be plumbed as a drain, even if it normally operates as a vent. That should be a wye.
    The connection to the main stack might be OK as a tee (vs. a wye) if you're using the main stack as a wet vent (but then you wouldn't have the other sideways tee upstream).

    • @omegaplumbing
      @omegaplumbing Před 5 měsíci

      You can put a tee on its back if it’s a dry vent. We tell apprentices not to do that in the beginning because they get confused. You can also install a sanitary tee vertically but on a 45 degree. But yes the practice is better with a wye for cleaning purposes. Yet that will never get a clean out.

    • @ncooty
      @ncooty Před 5 měsíci

      @omegaplumbing It's not a dry vent if it's lower than 6" above the flood level of the vented fixture.

    • @omegaplumbing
      @omegaplumbing Před 5 měsíci

      @@ncooty 908.0 Wet Venting.
      908.1 Vertical Wet Venting. Wet venting is limited to vertical drainage piping receiving the discharge from the trap arm of one and two fixture unit fixtures that also serves as a vent not exceeding four fixtures. Wet-vented fixtures shall be within the same story; provided, further, that fixtures with a continuous vent discharging into a wet vent shall be within the same story as the wet-vented fixtures. No wet vent shall exceed 6 feet (1829 mm) in developed length.

    • @jorgenorman8715
      @jorgenorman8715 Před měsícem

      @@omegaplumbing and I want to add the washing machine standpipe on the 1st floor to the 2nd floor bathroom’s 3 in stack, can I add a 1st floor washing machine standpipe to that same stack with a 3x3x2 tee. And should I also run a vent like you did?

  • @shanemattox6548
    @shanemattox6548 Před rokem +1

    Instead of attaching to existing vent could I use the same set up but use one of the venting caps?

  • @mattbgraves
    @mattbgraves Před 2 lety +1

    SICK BEATS BRO!

  • @dwaynejackson2470
    @dwaynejackson2470 Před měsícem

    He is living his best life 👉♥️

  • @paters18
    @paters18 Před 3 lety +14

    You just removed the main clean out drain for the house. Not to code.

    • @go-diy
      @go-diy  Před 3 lety +3

      has another in the back above !

  • @richricogranada9647
    @richricogranada9647 Před rokem

    Can only plumber transfer the laundry from inside the house to the garage, or another professional is needed?

  • @LetsdoIT-2024
    @LetsdoIT-2024 Před 3 měsíci

    Great video!
    Do you have a video for the relocation of the dryer vent/duct?

  • @cinepost
    @cinepost Před 3 lety +1

    With the use of an Oatey laundry box, If I were to lower the box so the top of the drain pipe is 28”, could I put the p-trap below the floor? I have a crawl space below the floor.

    • @go-diy
      @go-diy  Před 3 lety +2

      Of course you can, just respect the 28 ”and it will be fine

    • @ma7rix13
      @ma7rix13 Před 3 lety

      I don’t think that is “legal”. Call your local building inspector.

    • @mycats7321
      @mycats7321 Před 2 lety +8

      No. It is a code violation to put a standpipe P-trap below the finished floor. By code it must be a minimum of 6" and maximum of 18" above the finished floor.

  • @tryzydrate
    @tryzydrate Před 2 lety +4

    Sanitary tee shouldn't ever go on its back

  • @voliafouryou953
    @voliafouryou953 Před 3 lety +3

    Thank You for information!
    What is the minimum dimension from box to water trip???
    Thank You 🙏

    • @go-diy
      @go-diy  Před 3 lety +1

      for the drain ( p-trap) is 28 "minimum to 30"

  • @richardwhite6288
    @richardwhite6288 Před 2 lety +7

    CPVC isn't what you should put in walls... Copper,Pex or anything else...just saying...👍🏾

  • @tobyhall7704
    @tobyhall7704 Před 10 měsíci

    I WLD HAVE USED A PVC COUPLING FOR THE TOP! TO EACH HIS OWN. BOTH WLD WORK!

  • @decentralizedplanet482
    @decentralizedplanet482 Před 2 lety +5

    Man awesome videos! The music is distracting tho.

  • @charleswilliams3823
    @charleswilliams3823 Před 3 lety +3

    What advice do you have for someone who doesn't have any connections for a washer?

    • @luketitan526
      @luketitan526 Před 2 lety

      You can simply tie in to your existing line and do exactly as this video shows run your new washer box where you want it and connect vent to the current vent.! If close if not just run a new vent up the roof or if allow by code do a dry vent. ? Idk I’m just an apprentice

    • @proverbs2life
      @proverbs2life Před rokem

      Hire a plumber

  • @imaginaryworldoftoys
    @imaginaryworldoftoys Před rokem +1

    how much do you charge for all that work?

  • @patrickfrost4338
    @patrickfrost4338 Před rokem +3

    That's great now but what did you do with the clean out

    • @WAmed83
      @WAmed83 Před rokem

      Lol is that really necessary 🤣🤣

  • @ILiTIHiUIM
    @ILiTIHiUIM Před rokem

    The primer lord himself lol

  • @unkoyairving1965
    @unkoyairving1965 Před 3 lety +1

    Music is cool 😎

  • @rosebrown6296
    @rosebrown6296 Před 2 lety +4

    I need to see this process from the very beginning, starting with tearing down the wall

    • @mt-nv4jd
      @mt-nv4jd Před rokem +4

      1. Pick up saw. 2. Cut sheet rock. 3. Put down saw.

  • @garycasper2929
    @garycasper2929 Před 2 lety

    I love this guy. Face mask ☑️ gloves ( to work on nasty sewage pipe) blank.. lol..

  • @tonpear5909
    @tonpear5909 Před 8 měsíci

    You magically added the shear ring after installing the elastomeric coupler. Huh. There's an easier way than to screw up and edit out the mistake.

  • @benjaminpessah2612
    @benjaminpessah2612 Před 3 lety +1

    What is the rubber piece u used on the top of the pipe?

    • @go-diy
      @go-diy  Před 3 lety

      Coupling

    • @jecarsepulveda8237
      @jecarsepulveda8237 Před 3 lety

      It’s called a mission coupling

    • @mycats7321
      @mycats7321 Před 2 lety +1

      Sometimes called Fernco fitting.

    • @dee2134
      @dee2134 Před rokem

      Called being cheap and taking short cuts

    • @dee2134
      @dee2134 Před rokem

      Know the codes and suppose to use pvc 4in. Coupling

  • @omegaplumbing
    @omegaplumbing Před 5 měsíci

    That stand pipe looks pretty long.

  • @williamp9158
    @williamp9158 Před rokem

    Where was that second connection on the sanitary T going?

  • @donaldfrazier5244
    @donaldfrazier5244 Před 3 lety +4

    No deburring?

    • @dee2134
      @dee2134 Před rokem

      No reeming and beburrrr

  • @mattalbrecht7471
    @mattalbrecht7471 Před 3 lety +17

    Dude.... informative video...but this music!

  • @totallyarea
    @totallyarea Před 2 lety +8

    Just want to make sure you know this isn't up to code. Cant have the sanitary tee on its back and are primarily used in venting and must use a wye fitting.

    • @totallyarea
      @totallyarea Před 2 lety

      A little more info as to why. If you have a clog, you cant get the snake down.

    • @Eddie-In-Las-Vegas
      @Eddie-In-Las-Vegas Před 2 lety +4

      What fixture is that santee fitting on its back picking up? I hope you werent trying to use that piping configuration as your laundry vent, cause that's improper. Typically when you trap arm over to pickup the washer stand pipe p-trap you don't cut a fitting in on the trap arm, especially to put a sanitary tee fitting on its back onto a dirty pipe trap arm.
      Look at the original plumbing, their is a reason why the 2 inch laundry pipe drain came through the foundation on its own off the underground mainline sewer lateral. That was a designated piping configuration for a suds producing fixture (your washer). Furthermore, by looking at the original piping it shows you how to properly use a sanitary tee fitting by having it piped upright (not on its back) and having the top half "run" of the fitting be used for venting. On a "branch vent" system you can use sanitary tees facing down horizontally but never on its back horizontally on any soil pipe. You were better off just long arm trapping to the new washer box, even though technically that configuration would have had you more than five feet exceeding the code limit on a trap arm length, not to mention you would have never been able to make that corner with your soil stack in the way but could have atleast pipe it externally from the wall if need be. But atleast it still would have been on its own system. Think about it, if your mainline sewer backs up, it's now gonna send that shit water mixed with mushy toilet paper debris all through your laundry drain piping and p-trap because the way you "cheated" that pipe configuration for your new laundry box location. The way it was originally piped with the santee upright being vented and connected to that designated 2inch laundry drain pipe coming up through the floor(the one you have now capped off), that atmospheric pressure coming down through the roof down that vent pipe would have prevented any sewer waste and debris from entering the laundry pipe system in the event of mainline sewer stoppage. P-traps don't work very well when they got shit paper and feces clogged in the weir of the trap. Now you have added an extra step you have to do when after you clear your mainline stoppage you now then have to run water down that laundry stand pipe and hope you can flush out the mess that has clogged your washer stand pipe trap. Good luck with that nightmare. Doing a laundry room remodel and moving critical plumbing drain plumbing systems doesn't make sense if the end result is gonna be something of less value and ruin the integrity of something you originally had that was correctly done. These are things you have to weigh out and use critical thinking skills before you just go tearing into things and making up your own rules that go against decades of finely tuned practical piping engineering. If everyone used your nonsensical approach we all would slowly but surely be reverted back into the "dark ages" where intelligence became nonexistent and common sense society took a back seat to the Neanderthal conduct way of living life. You mustn't forget how quickly a civilized world crumbled and was brought to its knees starting from average people just doing things out of order. Don't be an active participant of this doomsday event!

    • @philhugill8458
      @philhugill8458 Před rokem

      At least they knew their GENDER back in the day.

  • @valentinaperez9117
    @valentinaperez9117 Před rokem +1

    No glue 😳

  • @Rich4life69
    @Rich4life69 Před 2 lety +2

    Crooked cut

  • @anniewills9348
    @anniewills9348 Před rokem +1

    I’m having drainage issues with my new washer

  • @ssabavkou
    @ssabavkou Před rokem +2

    Noticeable error. When accessing the vertical stack a T connection is an error. A Y connection is appropriate and placed above sewer clean out.

  • @capn1600
    @capn1600 Před 3 lety +2

    Why would you connect PVC pipe with a no hub coupling when you can just use a PVC coupling and glue it permanently

    • @ferdinanflores
      @ferdinanflores Před 2 lety +2

      I think it is because the 3” pipe is fixed and has no movement, it would be very difficult to put in a pvc coupling

    • @MrDW-ei1fe
      @MrDW-ei1fe Před 2 lety +3

      Pain in the ass to glue in a coupling.

  • @go-diy
    @go-diy  Před 3 lety

    RU101 VALVE czcams.com/video/AXWwPsTQ7fM/video.html

  • @lachcik5084
    @lachcik5084 Před 2 lety +1

    why not use a coupling????

    • @dee2134
      @dee2134 Před rokem

      Only us bands when you’re transitioning from cast iron to pvc . Otherwise use a coupling

  • @franciscotrujillo9471
    @franciscotrujillo9471 Před 3 lety +1

    The music is not good

  • @mixtecop
    @mixtecop Před 3 lety +4

    *I will never trust 1/2 inch PVC to run the water for the washer* 🙄

    • @go-diy
      @go-diy  Před 3 lety

      it is 2 ”pvc ! 🤷🏻‍♂️

    • @alexanderjamieson7971
      @alexanderjamieson7971 Před 3 lety +3

      @@go-diy I believe he is talking about the cpvc water lines. They become brittle and burst more easily than PEX or copper.

    • @jimh2061
      @jimh2061 Před 3 lety +1

      They run that cpvc in brand new homes. If it wasn't any good they wouldn't be using it. There would be a class action lawsuits like the poly butyl pipes.

    • @jamesmchugo9422
      @jamesmchugo9422 Před 2 lety

      Why? My Dad’s has CPVC water supplies. The house is 45 years old and has never had a problem. As for the lime and mineral issue, he is on a well with some of the hardest and highest iron water I’ve ever dealt with and still not a problem. The water softener fixes the hard water issues. PEX and copper are still better products. PEX probably the better because of its freeze resistance. And yes, CPVC will get brittle over time, especially if exposed to sunlight, but keeping out of UV light, mainly sun light will prevent most of that problem. PEX should also be stored and used where sun light can not touch it. PEX will deteriorate under prolonged UV exposure. If I were building new or replacing the plumbing I’d use PEX, cost is about the same as copper, but it’s so much easier to run and work with, the big savings is labor costs. But for a job like this, since the house is plumbed with CPVC, it’s best to stick with CPVC.

  • @JennaLeeEquals3
    @JennaLeeEquals3 Před 3 lety +1

    Would appreciate walk thru instead of music but... ok. Lol

  • @edreeves121
    @edreeves121 Před rokem

    Irritating music

  • @adv-fabiod4505
    @adv-fabiod4505 Před 3 lety +6

    Horrible music