  • In this video, we will install a rainproof outlet on the outer wall of the house.
    As many of you may know, an electrician's diploma is legally required to work on switches and outlets.
    I think that many people who do DIY get this qualification. This qualification itself is not so difficult as the passing rate of the written test is 60% and the passing rate of the proficiency test is 70%.
    Even a person like me who doesn't know Ohm's law could pass, so I think people who like electricity will definitely pass.
    Even if you are not good at electricity, you can pass it by reading one reference book and asking about 10 past questions.
    As for the proficiency test, those who do his DIY think that his hands are dexterous by nature, so don't worry.
    The difficulty level has increased a little since the last garage outlet expansion work, and we will install rainproof outlets on the outer wall of the house.
    The reason why I want an external outlet here is that I took the power from the outlet of the external lighting when I installed the security camera, but if I do not switch on the lighting, the power of the security camera will not turn on, so I installed another power supply I want to say that.
    The method of construction is to make a hole in the outer wall from the position where the outlet of the room is located and pull out the power cable.
    The construction itself is not that difficult, but it is a rough job of making holes in the outer wall, so if you want to try it, please do it at your own risk.
    This time, we are also extending the cable with a VE pipe, so please watch it till the end.
    I passed the exam by watching CZcams below
    ――――――――――――――――――――――――――――――――――――――――
    --- HOZAN Electrician test tiger
    ――――――――――――――――――――――――――――――――――――――――
    / hozantool
    Electrical equipment materials used for garage outlet expansion work
    ・ VVF cable 1.6mm 2 cores
    ・ VE tube
    ・ VE tube piece saddle
    ・ VE tube connector
    ・ VE tube coupling
    ・ Embedded double outlet
    ・ Exposure switch box
    ・ External switch box
    ・ Concrete screws
    ・ Drill for concrete
    ・ Plug-in type 2-terminal connector
    ・ Waterproof caulking material
    The tool used this time
    ・ Makita Rechargeable Impact Driver TD110DZ 10.8V
    ・ E-Value Vibration Drill EID-650VA
    #DIY
    #GARAGE
    #Type2electrician
    #Additionaloutlets
    #Rainproofoutlet
  • Jak na to + styl

Komentáře • 8

  • @user-gv9dk4yr4v
    @user-gv9dk4yr4v Před rokem +1

    ボックスで中継してるのはコンセントつけたい場所の壁裏から電源がとりにくいからですか?
    なぜケーブルを中継してるんですか?
    一本でコンセントまで引いたほうがいいのではと。
    ほんとはアースつけたいですけどね。
    コンセント部のコーキングは完全ならいいけどもし浸水したらかえって水の逃げ場がなくなるからどうなのかなと思います。

    • @ZUBUGARAGE
      @ZUBUGARAGE  Před rokem

      こんにちは、コメントありがとうございます。
      このコンセントは防犯カメラ用に設置したのですが、ちょうどいい場所に屋内コンセントが無く、ボックスで中継して伸ばしました。(アース線も来てれば良かったんですけどね)
      屋外コンセントは防水に気を使いますよね、水が入らないことを願います。

    • @user-gv9dk4yr4v
      @user-gv9dk4yr4v Před rokem

      @@ZUBUGARAGE 屋外なら中継せず一本で配線したほうが安全だと思います。
      コーキングは壁からの引出し穴の部分がされてればそれでいいと思います。

    • @user-tv5iz3pf2o
      @user-tv5iz3pf2o Před rokem

      外壁にネジを打つ際には、ネジ穴にコーキングした方が良いかと😊

    • @ko-ji1441
      @ko-ji1441 Před 11 měsíci

      @@ZUBUGARAGE
      アース線って新設でコンセント裏に挿して接地しちゃいけないんですかね?

  • @possibility.of.miracles

    屋外のボックス内で差し込みコネクタは好ましくない気がします

    • @ZUBUGARAGE
      @ZUBUGARAGE  Před 2 lety

      コメントありがとうございます。
      屋外ではリングスリーブで圧着するべきなのですね?
      勉強になりました。

    • @user-gv9dk4yr4v
      @user-gv9dk4yr4v Před rokem

      なぜ?