How to by-pass Standard 1 compressor | Daikin VRV3 | ermergency setting.

Sdílet
Vložit
  • čas přidán 26. 08. 2024

Komentáře • 59

  • @BonMj
    @BonMj  Před 2 lety +2

    Please like and share + Subscribe.
    Please leave your comments.
    Thanks🙏🙏

  • @amirhvaccenter5967
    @amirhvaccenter5967 Před rokem +2

    Bon mj u didn’t tell about bypass standard compressor 2 and inverter compressor for single outdoor in this video.
    Please explain

  • @anilpradhan2263
    @anilpradhan2263 Před 2 lety +2

    Good Bon sir well-done

  • @tabresztabu562
    @tabresztabu562 Před 2 lety +2

    Tq அண்ணா ✌️

  • @phoekwar233
    @phoekwar233 Před 3 měsíci +1

    Thank you so much Sir

    • @BonMj
      @BonMj  Před 3 měsíci

      Most welcome

  • @aureliancioroiu8178
    @aureliancioroiu8178 Před rokem +2

    Mr Bon.Thank you for all your guide.You are the best instructor.
    Would you help me please.I have the VRV Classic Inverter and in my case I have that issue: the H2P and H8P is blinking and H5P is ON.The compressor and fan does not working.
    Thermostat display indoor units shows Error button Menu of three of them and for other 2 units: Clean filter.
    Can I make the same steps as you showed in this video to bypass the Standard Compressor 1 or is different in my case?
    Is there a problem or mean some error?I thing the compressor does not have refrigerant,can also run the compressor and fan for this VRV Classic without refrigerant?.In the compressor 2 does exist refrigerant?Thank you!

    • @BonMj
      @BonMj  Před rokem

      Hi.thanks watching my video.
      1)What is the outdoor unit model
      2)what is the error

    • @aureliancioroiu8178
      @aureliancioroiu8178 Před rokem +1

      ​​@@BonMj Hi Mr Bon,the model for this VRV is: RXYCQ12A7Y1B DAIKIN EUROPE N.V.
      MFG DATE 2014.01
      DAIKIN VRV CLASSIC INVERTER.
      1) External single DAIKIN unit. When I start the VRV the master PCB model SEB11050(D) has: H2P and H8P blinking
      The H5P is ON.The other lights is off.The PCB does not have display.The PCB it looks like a VRV III.
      It is single external unit.Also the fan and compressor not working(is there a problem as long the gas is insufficient or not at all?the compressor and fan can work only if the PCB detect pressure and/or refrigerant?)
      2) Internal units
      On the Thermostat(remote controllers display i mean) from indoor units shows:
      ERROR BUTTON MENU
      I didn't press the Menu button because I didn't know.Now I know what I have to do to show the error in this display.
      Maybe the next 2 weeks can I tell you what error show in display from indoor units.Thank you!

  • @serviceacbekasi4733
    @serviceacbekasi4733 Před 2 lety +1

    God job ,ijin Belajar 😊

  • @manjuviratuperavai3610
    @manjuviratuperavai3610 Před 2 lety +2

    Tq sir🙏

  • @amirhvaccenter5967
    @amirhvaccenter5967 Před rokem +2

    Please tell me vrv3 u4 alarm
    All whole building all units same

  • @karaors8970
    @karaors8970 Před 2 lety +1

    Good video bon 🧿🛠️🤳🇹🇷👍

  • @dominicaliviado2
    @dominicaliviado2 Před rokem +1

    How to by pass standard 2 compressor at set button press same 19 times or 20 times because I look for your video for standard 2 compressor by pass but none, Sir Bon Mj

  • @VinodKumar-ix7rt
    @VinodKumar-ix7rt Před rokem +1

    Nice👍👍👍

  • @govindarasugovindarasu7440

    Hi sir Daikin KRP928BBS Adaptor card how to install the change over panel please thanks

  • @shivaHVAC
    @shivaHVAC Před rokem +1

    Sir how we know if the std 1 or 2 compressor is already bypassed?

    • @BonMj
      @BonMj  Před rokem

      Check emergency settings

  • @brandonle4930
    @brandonle4930 Před 2 lety +1

    Good video Bon! If I have VRV4 master and slave 1, can I bypass CU slave 1 and have master CU run? Thanks

  • @hidayaturrokhman3538
    @hidayaturrokhman3538 Před 2 lety +1

    Hy mr. Bon, I want to ask, how about multi outdoor emergency settings for the compressor?

    • @BonMj
      @BonMj  Před 2 lety

      Multi outdoor unit only can by pass the cu for vrv3(main,or slave 1 or 2)

    • @hidayaturrokhman3538
      @hidayaturrokhman3538 Před 2 lety +3

      @@BonMj that's right.. then if there is a problem with CU Slave 1, it means that vrv 3 multi outdoor unit can only by pass. which can be turned on CU main and slave 2. for CU slave 1 off (by pass) like that kah?

    • @BonMj
      @BonMj  Před 2 lety

      @@hidayaturrokhman3538 yes

    • @hidayaturrokhman3538
      @hidayaturrokhman3538 Před 2 lety +1

      @@BonMj thank you ..

    • @BonMj
      @BonMj  Před 2 lety

      @@hidayaturrokhman3538 welcome

  • @desmondteo6223
    @desmondteo6223 Před 2 lety +1

    Hi mr don ,how to contact u?

  • @kashibaba521
    @kashibaba521 Před rokem +2

    Bon Sir If the standard Compressor 1 is Defective we press the Set button 19 times for the by-pass setting But sir if the standard Compressor 2 is Defective then how many times press the set button??

    • @kashibaba521
      @kashibaba521 Před rokem +1

      In an other case if the Inverter compressor is Defective then What should we do?

    • @BonMj
      @BonMj  Před rokem +1

      If both compressor down,mean the system cant work .

    • @BonMj
      @BonMj  Před rokem +1

      This is single module?

    • @BonMj
      @BonMj  Před rokem +1

      Later i check.
      Standard compressor 2 a bit different

    • @kashibaba521
      @kashibaba521 Před rokem +1

      @@BonMj yes its Single module system

  • @wenjietea6212
    @wenjietea6212 Před 2 lety +1

    Hi bon
    After change new standard Compressor still high amp 9++
    What is the reason??

    • @BonMj
      @BonMj  Před 2 lety

      Check cu EEV

    • @wenjietea6212
      @wenjietea6212 Před 2 lety

      @@BonMj 👍

    • @amirhvaccenter5967
      @amirhvaccenter5967 Před rokem +1

      Please tell me u4 alarm for vrv3
      All building all units

    • @BonMj
      @BonMj  Před rokem

      @@amirhvaccenter5967 check communication wire, CU main pcb or indoor pcb

  • @mohammedrezaulkarim1702
    @mohammedrezaulkarim1702 Před 17 dny +1

    Sir i need inverter comp
    Model JT1GCVDKYR@B
    once nos. In Bangladesh
    Chittagong
    Please...

    • @BonMj
      @BonMj  Před 15 dny

      Sorry dun have

    • @mohammedrezaulkarim1702
      @mohammedrezaulkarim1702 Před 9 dny

      @@BonMj
      Sir,Thank you
      For your suggestions.
      I change Compressor and fill gas with vacuum. Now VRV run smoothly. So many thanks again

  • @mohdmaqsoodshaikh5234
    @mohdmaqsoodshaikh5234 Před rokem +1

    Sir Multy unit Daikin vrv3 18hp inverter compressor bay paas codes pls help

    • @BonMj
      @BonMj  Před rokem

      Multo outdoor unit cant by pass compressor.
      Only can by pass the cu

  • @rahulramesh9735
    @rahulramesh9735 Před 2 lety +1

    Hi, master
    Daikin vrv 3 error L5
    what was the problem, boss

    • @BonMj
      @BonMj  Před 2 lety

      Check inverter pcb and inverter compressor

    • @BonMj
      @BonMj  Před 2 lety

      @@rahulramesh9735 you replace inverter pcb?
      Do you check compressor terminal?

  • @bvrajuchinni6340
    @bvrajuchinni6340 Před rokem +1

    CU meaning

    • @BonMj
      @BonMj  Před rokem

      Condensing unit