Video není dostupné.
Omlouváme se.

How to replace Outdoor ECM Motor with a PSC Motor

Sdílet
Vložit
  • čas přidán 15. 08. 2024
  • Wanna Learn more about hvac? Check out my hvac tips for technicians playist.
    • HVAC Tips for Technicians
    Join this channel to get access to perks:
    / @taddydigest
    HVAC Transformers and Relay Basics Video
    • HVAC Transformer and R...
    HVAC Motor Basics for Beginners Video
    • HVAC Motor Basics for ...
    Fieldpiece SC440 True RMS Clamp Meter with Temperature, Inrush Current, Capacitance and Backlight
    amzn.to/3pCn4XP

Komentáře • 72

  • @USA-GreedyMenOfNoIntegrity

    You don't need any relays. Just wire it direct to defrost board and contactor like a standard hp. The difference between hi/lo rpm on that 4 pole motor is not going to be enough to affect anything and it will be much simpler. I've got several in the field working fine.

    • @TaddyDigest
      @TaddyDigest  Před rokem +8

      Bro you are too smart to not have a CZcams channel
      You need to put your knowledge out there
      I will support you

    • @dporrasxtremeLS3
      @dporrasxtremeLS3 Před rokem

      @@TaddyDigest Yes! Thanks for sharing your wealth of information!

    • @HVArctiC-Monkey
      @HVArctiC-Monkey Před rokem

      @@TaddyDigest I don't work on heat pumps much, would that defrost board for the black wire control when voltage is sent to the motor based on cooling demand? Making the relays and 24v control wire redundant?

    • @ronaldmcdonald999
      @ronaldmcdonald999 Před rokem +1

      Lol

    • @Balticblue93
      @Balticblue93 Před rokem

      If he wasn't a hack, he would have known he didn't need relays. I wonder where he learned that? If a guy that doesn't work on heat pumps often knows how to fix it better than the guy doing the work, that is scary that you are allowed to even do this type of work. Oh wait! You are not licensed and just have a CZcams page. You literally installed the wiring incorrectly so the fan ran the incorrect direction. Haha!! Such a hack!!

  • @Cam_V910
    @Cam_V910 Před 2 měsíci +4

    Thanks for this. All ECM motors are garbage & unreliable at best. Whatever money & energy you think you are saving by being efficient. You will be punished by the repair cost. Any & all ECM motors out of warranty quickly get a PSC upgrade & my customers are thrilled.

  • @NoahsTotallyAwesomeShow
    @NoahsTotallyAwesomeShow Před rokem +2

    I love seeing you hang out with your fans

    • @TaddyDigest
      @TaddyDigest  Před rokem

      I love seeing 👀 you in the comment section hehehe

  • @cashonlyj3469
    @cashonlyj3469 Před rokem +2

    Man that one part you were talking so fast you couldn't hear your self I'm thinking . Great video sir.

  • @Firefighterf28
    @Firefighterf28 Před 8 měsíci +4

    Why would you need the relays,,, A call for cooling or heating will energize the contactor which will bring this motor on... L1 or L2 Of the motor will be hooked to the defrost board. The other line will be at the contactor to control this motor on defrost mode.... You were not using the low speed on this condenser motor if you were then the relays would be needed because it was a two stage system (compressor)...
    But you were only using the high speed on the condenser motor.... Just wondering thanks for your video

  • @goodkao
    @goodkao Před 25 dny

    Hi, I'm confused with this fan motor replacement with relay.
    Can I replace it without a relay? The reason you use relays is because it's a heat pump, right? I love all your videos. Thanks for all your CZcams videos.

  • @brucemcgee2281
    @brucemcgee2281 Před rokem +2

    Cheap capacitors are no bargain. If you are inclined, you can replace the caps on that circuit board with new ones, clean it up, and it will probably work.

    • @TaddyDigest
      @TaddyDigest  Před rokem +1

      I may start doing that because of the quality of new parts
      I would rather repair Then replace

    • @emilionunez4566
      @emilionunez4566 Před rokem

      @@TaddyDigest if you do please show an example 😁 thx.

  • @danielzertuche9893
    @danielzertuche9893 Před rokem +2

    Great video ! On converting motors.

  • @Dillonmechanical
    @Dillonmechanical Před rokem +2

    Awesome vid taddy

  • @tairdudeusa7981
    @tairdudeusa7981 Před 23 dny +1

    This is how you change a 15 SEER to a 10 SEER.

  • @jamesbroomfield7799
    @jamesbroomfield7799 Před rokem +1

    I don't understand. Why is the low voltage needed still? I thought the whole purpose of eliminating the ecm motor was to get away from all those low voltage wiring. Couldn't you just run the psc motor black and white to the top of the contactor and the 2 Browns to the cap? Then once calling for cooling the contactor closes and turns on the compressor along with the fan. Or are you still trying to keep both hi and low speed on the unit? The unit I'm trying to figure out is a Gibson. First time ever working on this brand. The outdoor fan motor black and brown go directly to line 1 and 2 of contactor, the white and I believe yellow, go directly to the 24v side of the transformer. Then a blue wire goes to the board where I think it says fan 2. I accidentally erased the pics I had cuz they were blurry and forgot to retake pics before heading down. But the blue wire definitely goes to the board. I just can't fully remember what the point was, I believe it said fan 2. This is in Vegas so defrost probably not going to be used. Any advice on how to go direct to a psc motor would be greatly appreciated. I was hoping to directly wire it like any other regular condenser fan motor. The only wire I'm concerned about is the blue wire going to the board. If I leave that disconnected would it cause any issues? Any feedback is super helpful. Thanks in advance. Nvm. Lol. Smh. I realized this was a heat pump. Im pretty sure im working on a gas pack. I only looked at it for a hot sec because i was fixing the other unit next to it, which was just a badic Goodman gas pack. I was going back the next day to look at the Gibson but i just took quick glance at it and saw the outdoor fan wasn't running. I was wondering why you had two relays lol

  • @jrh86
    @jrh86 Před rokem +1

    Brilliant stuff 👍👍👍

  • @yodamanrulz176
    @yodamanrulz176 Před rokem +1

    TADDY: I like the way you say these two wires without reinforcing which wires these two wires are. Very lazy to not speak in complete sentences. Not having to read somebody else’s mind is a helpful thing. If you’re not academically acute, maybe you need to work on it with excellence in mind. I say this with the utmost respect for you, you are an exquisite human being.Why is it people don't budget for HVAC maint & upkeep from the git-go? That's all about neglect. Regular maintenance will solve problems B4 they become ultra problems. WORD...😢😢

    • @TaddyDigest
      @TaddyDigest  Před rokem

      I was born yesterday
      Just learning As I go
      I'm glad that someone obviously highly educated as yourself
      Is giving me the advice that I have always needed

    • @TaddyDigest
      @TaddyDigest  Před rokem

      thanks 👍

  • @jamesbroomfield7799
    @jamesbroomfield7799 Před rokem +3

    Instead of using relays couldn't you just attach it to the contactor when it calls for cooling and closes to turn on the compressor? Could you just wire it like any other fan to the contactor? And br br to the cap? This is on a gas pack not hp. Also. I just realized youre working on an hp

    • @michaelbroadbent4703
      @michaelbroadbent4703 Před měsícem +1

      the condensor fan has to go through the defrost control board on a heat pump. it has to be off when in defrost mode

  • @247VillainStatus
    @247VillainStatus Před rokem +1

    As a new member, I have a question. How much would you charge me, if I send my home plans to you, and have you size how many heads/ size that I would need? Thx Kris

  • @thecurious6721
    @thecurious6721 Před rokem +3

    Cool. Looking forward to it. Ted, do you have any tip of replacing furnace ecm (with dc signal) blower motor with psc motor (maybe with the universal control board), on single/two stage furnaces. I couldnt figure out, or find any info. All motors are furnace specific, expensive and not always in stock. Very frustrating.

    • @hvacmisadventures
      @hvacmisadventures Před rokem +4

      You talking about the ones with the 16 pin connectors? If so Qwik Products makes a board called qwikswap v3 and you plug the connectors into the board and then it's got spots on it for different speed taps for a PSC motor to replace the ecm

    • @TaddyDigest
      @TaddyDigest  Před rokem

      Yes Here is a video of a product you can use czcams.com/video/4HyDhHJ4Kms/video.html

    • @TaddyDigest
      @TaddyDigest  Před rokem

      Thanks @HVAC Misadventures

    • @hvacmisadventures
      @hvacmisadventures Před rokem

      @@TaddyDigest we on the same page 😁. Hope you're having a good start to the week man.
      It's not something I like to do but in desperate times I've also "hard wired" a PSC to run 24/7 so you don't have to worry about controlling it on / off - it's just always running. Not something I recommend or like to do but it was an old piece of equipment and the people were good friends in a bad place 🤷🏻‍♂️
      Qwikswap is nice but pretty expensive

    • @thecurious6721
      @thecurious6721 Před rokem

      @@hvacmisadventures unfortunately, no :( I am talking about ecm motors (constant cfm) with with serial communication 4 signal wires, with DC volt/amp signal. All proprietary and not interchangeable (between brands, probably not even between models of the same brand). Looks like all furnaces are using those type of motors now. I didnt see any new furnace with 24v signal ecm motor.

  • @mikestevenson1819
    @mikestevenson1819 Před 9 měsíci +1

    Was that a blower motor ?

  • @PumpkinKingXXIII
    @PumpkinKingXXIII Před 8 dny

    What is so aggravating is they don’t sell the module separately. New motor should be $200 at most and a new module a should be $200-$250z The inrush limiter or the capacitors go bad but manufacturers want all the cash so the pour silicon all over the components so servicing with a new 105c cap for 12 bucks or a 3 dollar inrush current limiter from Dudley can’t be easily replaced and only sells a complete assembly and want $700-$1100

  • @TomLawson05
    @TomLawson05 Před rokem +1

    Good video although reverse wires should be put underneath away from kids and public

    • @TaddyDigest
      @TaddyDigest  Před rokem

      Great point could have just used some water ties

  • @BeersHVAC
    @BeersHVAC Před rokem +1

    You are the bomb!

  • @ronaldmcdonald999
    @ronaldmcdonald999 Před rokem +1

    Your videos are funny lol

  • @abdullah_q8171
    @abdullah_q8171 Před rokem

    can you use a motor that is more powerful than the old one.
    I mean more HP

  • @CesarHernandez-mz4mb
    @CesarHernandez-mz4mb Před rokem +1

    ME ENCANTA , MUY BIEN

  • @jorgegomez973
    @jorgegomez973 Před rokem +2

    Hi. How are you? I’m a member

    • @TaddyDigest
      @TaddyDigest  Před rokem +1

      Awesome thank you for joining here is my email tadfuller1@gmail.com

    • @jorgegomez973
      @jorgegomez973 Před rokem +2

      @@TaddyDigest Thank you for your great information

  • @yodamanrulz176
    @yodamanrulz176 Před rokem +2

    Once again, knowing a technical thing, and knowing how to teach it, are two different things for most people. Most people think they’re smart enough not to engage acute perspective on what they’re doing. Think about what you’re doing while you’re teaching something. One lesson to learn, is to keep your fat fingers out of the picture while you’re showing something. Use a chopstick or pencil pointer of some sort. Have somebody with acute observational skills review your instructional videos, and learn from their perspective. Invariably most blue-collar, technical people eschew better educational perspectives. Being academically lazy I say, to be avoided…

  • @mikeg3529
    @mikeg3529 Před 9 měsíci +2

    "900 to 1100 rpm"
    Seriously, what is even the point of this over complicated non-sense. Sure, save $1.37 in electricity over the course of a few years for whenever the motor spins 900 rpm instead of 1100. And then pay out $1500 to replace it when it fails way before a psc motor would have 😂

  • @mr.18s73
    @mr.18s73 Před rokem +1

    Man that’s an easy one😂 , try taking the blades off when the shaft is embedded with rust 😂 it ain’t happening 😢
    Good stuff tho

  • @franciscocastellanos9157
    @franciscocastellanos9157 Před 11 měsíci +1

    Great! You have had defeated the purpose of an ECM blower motor which is a multi speed motor NOT a Fixed speed of PSC motors. NO bueno

    • @TaddyDigest
      @TaddyDigest  Před 11 měsíci +3

      I saved an old lady fifteen hundred dollars so I say success.

  • @fistinyourface78
    @fistinyourface78 Před rokem +1

    Why do you have 2 relays with jumpers? Is one for heat and other for cooling?